Boeing 767-34AF
Service difficulty reports · 6,321
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA0661945Floor Panel · damagedINSPECTION TYPE:C, MCD STA 540 TO 654+22 RBL 55" TO RBL 77" FLOOR PANEL FOUND 2 DAMAGED AND 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10661904Floor Panel · damagedINSPECTION TYPE:C, STA 654+22 TO 676 LBL 11 TO RBL 11 FLOOR PANEL FOUND 2 DAMAGE AND 13 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10661472Connector · damagedINSPECTION TYPE: E, TOP AIR TURN BACK AT 10:13Z FOR FWD EQPT OVHT, PASSING 10,000" DURING CLIMB, FWD EQPT OVHT EICAS MESSAGE ALONE WITH ASSOCIATE OVERHEAD OVHT WARNING LIGHT ILLUMINATED, AFTER COMPLETING FWD EQUIPMENT OVERHEAT CHECK LIST ON FINAL, FWD EQUIPMENSDR IPXA10661447Floor Panel · damagedPOS 11L, FLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10661455Control Panel · inoperativeINSPECTION TYPE:E, TOP ENG ANTI ICE SELECTED AND SWITCH WOULD NOT STAY DEPRESSED. R & R KERRY SWITCH FOR RT ENG A/I, NO HELP. R & R ANTI ICE CONTROL PANEL, ROBBED PANEL REF MM 30 11 01, 4 MFG SWPM 20 84 18.SDR IPXA0661405Guard · brokenEMERGENCY LIGHT ARMED SWITCH GUARD IS BROKEN. R & R EMERGENCY LIGHT ARMED SWITCH GUARD WITH SERVICABLE UNIT IAW IPC 33-51-08, ITEM 15. OPS CHECK OK.SDR IPXA10661275Eadi · intermittentCAPT EADI AND EHSI BLANKED OUT, BOTH NORM AND ALT. R & R EADI AND EHSI SYS OPS NORMAL.SDR IPXA10661155Floor Panel · damagedMAIN DECK FLOOR PANEL POS 4L HAS A .5" HOLE. IDENTIFIED AS MAJOR REPAIR. INSTALLED FLOOR PANEL, SEALANT & TAPE REF MM 53-01-06-4, THIS CLEARS D411572.SDR IPXA10661152Indicator · contaminatedON TAXI OUT LOST CAPT'S EADI, BTB TO RAMP AND EADI CAME BACK ON, PULLED INTO CHOCKS AND EHSI WENT OFF AND ON A COUPLE OF TIMES AND HEARD SOME ELECTRICAL ARCING BEHIND INSTRUMENT PANEL, SAW AND SMELLED ACRID SMOKE REMOVED CAPT'S EADI AND EHSI, VISUALLY CKD SDR IPXA10661148Sensor · inoperativeINSPECTION TYPE:E, TOP ATB - FWD EQUIPMENT OVERHEAT ECIAS DISPLAY IN STANDBY. IN OVERRIDE ALSO HAD FWD EQUIPMENT OVERHEAT DISPLAYED. T/S IAW FIM 21-58-00 FIG 115, 116. R & R FWD LOW FLOW DUCT SENSOR IAW AMM 21-58-17-2. ALSO FOUND FWD SUPPLY CK VALVE AND FWDSDR IPXA10661192Frame · crackedINSPECTION TYPE:C, NR 1 PYLON INTERNAL LT SIDE BS 285.45 VERTICAL FRAME CRACK NR1 PYLON INTERNAL LT SIDE BS285.45 VERTICAL FRAME REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02.SDR IPXA10661211Floor Panel · damagedINSPECTION TYPE:C, MCD STA 540 TO 654+22 LBL 33 TO LBL 55, FLOOR PANEL FOUND 1EA DAMAGED AND 4 DENTS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10661210Floor Panel · damagedINSPECTION TYPE:C, MCD STA540 TO 654+22 LBL 55 TO LBL 77 FLOOR PANEL FOUND 1 DAMAGED & 6 DENTS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10661209Floor Panel · damagedINSPECTION TYPE:C, MCD STA 540 TO 654+22, LBL 11 TO RBL 11 FLOOR PANEL FOUND 4 DAMAGED & 10 DENT FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10661208Floor Panel · crackedINSPECTION TYPE:C, MCD STA 930 TO 977, RBL11 TO RBL33, FLOOR PANEL FOUND CRACK FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10661207Floor Panel · damagedINSPECTION TYPE:C, MCD STA 540 TO 654+22, LBL 11 TO LBL 33, FLOOR PANEL, FOUND 1 DAMAGED & 9 DENT. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10661193Fairing · delaminatedINSPECTION TYPE:C, LT WING INBD MAIN FLAP L/E FOUND DELAMINATION COMPOSITE HOT BOND REPAIR CARRIED OUT IAW SRM 51-70-05, PAR 5A (1) FIG 5.SDR IPXA10661261Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQUENCE NR 330-F1-02 THE EXISTING REPAIR DOES NOT CORRLATE TO A SRM JUST AT BS 328 TO BS 345 BETWEEN S35R AND S37R SURVEY SEQ NR 330-F1-02, FX SKIN REPAIRED IAW R53-31-36782 & EO B767-5330-38845 JUST AT BS328 TO BS345 BTN STR35R SDR IPXA10661260Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQUENCE NR 330-F1-01 THE EXISTING REPAIR DOES NOT CORRELATE TO A SRM JUST AT BS 143 TO BS 164 BETWEEN S21R AND S27R SURVEY SEQ 330-F1-01 FX SKIN REPAIRED IAW R53-11-36792 & EO B767-5330-38856 JUST AT BS143 TO BS164 BTN STR21R & SSDR IPXA10661194Wedge · chafedINSPECTION TYPE:C, RT WING NR 7 SLAT T/E WEDGE FOUND CHAFED. METAL HOT BOND REPAIR CARRIED OUT IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, SHEET 8.SDR IPXA10661172Stiffener · crackedINSPECTION TYPE:C, MEC COMPT STA 246 FLOORBEAM ATT STIFFENER FOUND CRACK AT LBL40" MEC COMPT BS 246 LBL40" FLOORBEAM ATT STIFFENER REPAIRED IAW SRM 53-10-51-2R4, FIG 201, ORG MATL IS BAC1490-2793-7075T62, CRK LENGTH IS 1", THIS REPAIR IS CLASSIFIED AS A MAJOSDR IPXA10661190Skin · crackedINSPECTION TYPE:C, DMI D423950 - E/E BAY ACCESS DOOR CRACK - INTERIM REPAIR E/E BAY ACCESS DOOR PREVIOUS CRACK AREA BLENDED DEPTH 0.20" AND LENGTH IS 1" IS ACCEPTACBLE IAW HX RS R52-00-36779 AND EO B767-5240-38816.SDR IPXA10661049Lamp · inoperativeLT EXTERIOR EMERGENCY LIGHT FOUND INOP DURING MX INSP PS1 CHECK ITEM. CORRECTED BY REPLACING THE LAMP; OPS CHECKS NORMAL.SDR IPXA10661048Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL POSITION 2 RT HAS DAMAGE. REMOVED DAMAGE AND REPAIRED IAW SRM 53-00-50-2R.SDR IPXA10660907Floor Panel · damagedMAIN CARGO DECK POSITION 6L, LBL 64 AND LBL 58 TEMP REPAIRED. MFG AND INSTALLED NEW PANEL IAW EO B767-5320-9693 G.SDR IPXA10660986Skin · damagedINSPECTION TYPE:C, FUSELAGE (1 EA) HOLE DEEP COUNTERSUNK WAS FOUND DURING EO B767-5350-17922 ACCOMPLISHED AT LT SIDE STA 955 AFT AREA LOWEST ROW THE THRU FASTENER COUNTED FROM FWD. OPEN HOLE HFEC INSPECTED, NO CRACK FOUND. NEW BACB30NY14K26X FASTENER INSTALLSDR IPXA10660831Switch · looseEMERGENCY DECLARED - EICAS MSG "LE SLAT ASYM" L/E LIGHT ILLUM WITH FLAP LEVER IN 1. BOTH FLAP POINTERS WERE CORRECT. T/S IAW FIM 27-81-00 BLOCKS 1-3 SUB 9, FOUND NR11 SLAT 301 SWITCH TARGET LOOSE IN MT. SECURED TARGET AND BITE CHECK PSEU WITH NO FAULTS. CYSDR IPXA10661013Floor Panel · damagedINSPECTION TYPE:C, STA 1480 TO 1605 LBL 33 TO LBL 55 FLOOR PANEL FOUND 1 DAMAGED AND 13 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660977Floor Panel · damagedINSPECTION TYPE:C, STA 1112 TO 1197+22 LBL 11 TO RBL 11, FLOOR PANEL FOUND 2 DAMAGED AND 14 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660975Floor Panel · damagedINSPECTION TYPE:C, STA 977 TO 1043 RBL 33 TO RBL 55 FLOOR PANEL FOUND 1 DAMAGED AND 13 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660974Floor Panel · damagedINSPECTION TYPE:C, STA 876 TO 933 RBL 77 TO RBL 89 FLOOR PANEL FOUND 1 DAMAGED AND 8 DENT MARKS AND DEEP SCRATCH MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10660973Floor Panel · dentedINSPECTION TYPE:C, STA 933 TO 977, LBL 11 TO LBL 33, FLOOR PANEL FOUND 11 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660972Floor Panel · damagedINSPECTION TYPE:C, STA 740 TO 830, LBL 55 TO LBL 77, FLOOR PANEL, FND 3 DAMAGED AND 13 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660971Floor Panel · damagedINSPECTION TYPE:C, MCD STA 1480 TO 1605, LBL 11 TO RBL 11, FLOOR PANEL FOUND 2 DAMAGED AND 12 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR IPXA10660955Floor Panel · damagedINSPECTION TYPE:C, MCD STA 985 TO 1087, LBL 77 TO LBL 88, FLOOR PANEL FND 1 DAMAGED & 7 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660937Floor Panel · damagedINSPECTION TYPE:C, MCD STA 654+22 TO 686 LBL 11 TO RBL 11 FLOOR PANEL FOUND 2 DAMAGED & 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660936Floor Panel · damagedINSPECTION TYPE:C, MCD STA 764 TO 876, LBL 77 TO LBL 89, FLOOR PANEL FOUND 4 DAMAGED & 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660935Floor Panel · damagedINSPECTION TYPE:C, MCD STA 533 TO STA 654+22 LBL 11, RBL 11, FLOOR PANEL FOUND 1 DAMAGED & 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660934Floor Panel · damagedINSPECTION TYPE:C, MCD STA1197+110 TO 1263 RBL 77" TO RBL 89" FLOOR PANEL FOUND 1 DAMAGED & 4 DEEP SCRATCH MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10660754Floor Panel · damagedMCD POS 4 CTR FWD FLOOR PANEL REPAIR, STA 610 BL0 WL200. REPLACED FLOOR PANEL IAW EO B767-5320-09793-G.SDR IPXA10660753Lamp · inoperativeINSPECTION TYPE:PS, EMERGENCY LIGHT BELOW CREW ENTRANCE OUT. RELAMPED IAW AMM33-51-16-2.SDR IPXA10660741Floor Panel · damagedREF D 427434, P2 LT AFT HAS INTERIM REPAIR TO HOLE 1.75 DIA. (STA 390, LBL 62) REPLACED FLOOR PANEL IAW EO B767-5320-09793-G.SDR IPXA10660740Floor Panel · damagedREF D412069 MCD FLOOR PANEL 4L AFT AREA SECOND PANEL FROM OTBD (STA 654+ 110, LBL 65) HAS 3/4" HOLE. REPLACED FLOOR PANEL IAW EO B767-5320-09793-G.SDR IPXA10661040Skin · misrepairedINSPECTION TYPE:C, RT WING INBD AILERON EXISTING REPAIR PATCH NOT IAW SRM 57-60-01-2R1, TABLE 3, NOTE G. COMPOSITE WET LAY UP REPAIR CARRIED OUT AT EXISTING REPAIR PATCH AREA IAW EO B767-5750-38681 AND RS R57-60-36772.SDR IPXA10661039Skin · misrepairedINSPECTION TYPE:C, RT WING INBD AILERON EXISTING REPAIR PATCH NOT IAW SRM 57-60-01-2R1, TABLE 3, NOTE G. COMPOSITE WET LAY UP REPAIR CARRIED OUT AT EXISTING REPAIR PATCH AREA IAW EO B767-5750-38681 AND RS R57-60-36772.SDR IPXA10661038Skin · misrepairedINSPECTION TYPE:C, RT WING INBD AILERON EXISTING REPAIR PATCH NOT IAW SRM 57-60-01-2R1, TABLE 3, NOTE G. COMPOSITE WET LAY UP REPAIR CARRIED OUT AT EXISTING REPAIR PATCH AREA IAW EO B767-5750-38681 AND RS R57-60-36772.SDR IPXA10661037Skin · misrepairedRT WING INBD AILERON EXISTING REPAIR PATCH NOT IAW SRM 57-60-01-2R1, TABLE 3 NOTE G. COMPOSITE WET LAY UP REPAIR CARRIED OUT AT EXISTING REPAIR PATCH AREA EO B767-5750-38681 AND RS R57-60-36772.SDR IPXA10661036Skin · misrepairedRT WING INBD AILERON EXISTING REPAIR PATCH NOT IAW SRM 57-60-01-2R1, TABLE 3 NOTE G. COMPOSITE WET LAY UP REPAIR CARRIED OUT AT EXISTING REPAIR PATCH AREA IAW EO B767-5750-38681 AND RS R57-60-36772.SDR IPXA10660956Seat Track · corrodedINSPECTION TYPE:C, M/DECK STA 764 RBL 33" SEAT TRACK FLANGE CORROSION. M/D STA665.5 - STA782.5 RBL33 SEAT TRACK REPAIRED IAW SRM 53-00-52- 2R9 FIG 201, ORG MATL IS BAC1520-2772-7150-T77511, CORROSION CRACK AT STA 761.25 AREA, CUT OFF LENGTH IS 117" THIS REPAISDR IPXA10660719Arm · inoperativeRT SLIDING WINDOW WILL NOT CLOSE PROPERLY. REPLACED AND ADJUSTED LOWER LINK ARM (REF FIG 501, AMM 56-11-02-5 ITEM 7) PERFORMED SATISFACTORY OPS CHECK OF WINDOW REF AMM 56-11-02-6.
Back to Boeing 767-34AF