Boeing 767-34AF
Service difficulty reports · 6,321
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76734AF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10662653Floor Panel · damagedD424529 MAIN CARGO POS 5 L FLOOR PANEL 2ND FROM OTBD HAS .5" HOLE. REMOVED AND MFG NEW FLOOR PANEL IAW B767-5320-9693G.SDR IPXA10662475Eadi · inoperativeBOTH CAPT AND F/O EADI BLANKED AFTER T/O. EADI S/G CB RESET, E/E COOLING TEST, EFIS TEST AND CHECKED DISPLAY UNIT COOLING SCREEN, ALL COND NORMAL.SDR IPXA10662573Panel · crackedINSPECTION TYPE:C, RT WING NR7 SLAT CLOSURE PANEL EXISTING REPAIR PATCH CRACKED. COMPOSITE REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5H, FIG 15, REV 47.SDR IPXA10662538Floor Panel · damagedINSPECTION TYPE:C, MCD STA 930 TO 975 LBL 11" TO RBL 11" FLOOR PANEL, FOUND 1 DAMAGED, 1 GOUGE & 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662637Skin · misrepairedINSPECTION TYPE:C, SURVEY SEQUENCE NR331-F1-02 THE EXISTING REPAIR PATCH DOES NOT CORRELATE TO A SRM JUST AT BS 446 TO 461 BETWEEN STR -23R AND STR 25R. FX SKIN REPAIRED IAW HX RS R53-31-36824 REV A & EO B767-5330-39678-A. JUST AT BS446-461 BTN STR 23R & 25RSDR IPXA10662599Floor Panel · damagedINSPECTION TYPE:C, MCD STA 1480 TO 1599 RBL 33" TO RBL 55" FLOOR PANEL FOUND 1 DAMAGE & 8 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662598Floor Panel · damagedINSPECTION TYPE:C, MCD STA 1331 TO 1480 LBL 77" TO LBL 89" FLOOR PANL FOUND 1 DAMAGE & 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662597Floor Panel · damagedINSPECTION TYPE:C, MCD STA 412 TO 540 RBL 33" TO RBL 55" FLOOR PANEL FOUND 1 DAMAGES & 7 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662596Floor Panel · damagedINSPECTION TYPE:C, MCD STA 412 TO 550 LBL 77" TO LBL 89" FLOOR PANEL FOUND 3 DAMAGES & 15 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662595Floor Panel · damagedINSPECTION TYPE:C, MCD STA 412 TO 540 LBL 11" TO RBL 11" FLOOR PANEL FOUND 1 DAMAGE & 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662594Floor Panel · damagedINSPECTION TYPE:C, MCD STA 540 TO 654+22 RBL 55" TO RBL 77" FLOOR PANEL FOUND 1 DAMAGE & 10 DENT MARKS, FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662579Floor Panel · damagedINSPECTION TYPE:C, MCD STA 540 TO 654+22, LBL 11" TO LBL 33" FLOOR PANEL FOUND 1 DAMAGE AND 8 DENT MARKS. FLOOR PNL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662578Floor Panel · damagedINSPECTION TYPE:C, MCD STA 281 TO 412 RBL 77" TO RBL 89" FLOOR PANEL FOUND 1 DAMAGED & 8 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662577Floor Panel · damagedINSPECTION TYPE:C MCD STA 685 TO 730 LBL 11" TO RBL 11" FLOOR PANEL FOUND 1 DAMAGE, 1 GOUGE & 5 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662576Floor Panel · damagedINSPECTION TYPE:C, MCD STA 654+22 TO 685 LBL 11" TO RBL 11" FLOOR PANEL FOUND 3 DAMAGES, 1 GOUGED AND 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662575Floor Panel · damagedINSPECTION TYPE:C, MCD STA 1087 TO 1197+22 LBL 77" TO LBL 89" FLOOR PANEL FOUND 1 DAMAGE AND 6 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662574Floor Panel · damagedINSPECTION TYPE:C, MCD STA 1114 TO 1197+22 LBL 11" TO RBL 11" FLOOR PANEL FOUND 2 DAMAGES AND 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & INSTALLED IAW AMM 53-01-01.SDR IPXA10662571Floor Panel · damagedINSPECTION TYPE:C, MCD STA 685 TO 764, RBL 77" TO RBL 89" FLOOR PANEL FOUND 1 DAMAGE & 6 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662541Floor Panel · damagedINSPECTION TYPE:C, MCD STA 830 TO 933 LBL 11" TO RBL 11" FLOOR PANEL FOUND 1 DAMAGED & 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662540Floor Panel · damagedINSPECTION TYPE:C, MCD STA 984 TO 1087 LBL 77" TO LBL 89" FLOOR PANEL FOUND 1 DAMAGED & 8 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662539Floor Panel · damagedINSPECTION TYPE:C, MCD STA 977 TO 1114 LBL 11" TO RBL 11" FLOOR PANEL FOUND 1 DAMAGE AND 11 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662386Detector · inoperativeINSPECTION TYPE:E, TOP ATB - RT DUCT LEAK LIGHT ILLUM AND ASSOCIATED EICAS MSG R BLD DUCT LEAK DISPLAYED. IAW FIM 26-18-00, FIG 104. R & R M691 CONDITION RECURS AFTER 5 MINUTES RT ENG OPERATION. R & R TS218 DUE TO BEING OUT OF LIMITS CORE TO CORE MAX RES CHSDR IPXA10662570Stiffener · crackedINSPECTION TYPE:C, FWD CARGO COMPT WING CTR TANK FRONT SPAR UPPER VERTICAL STIFFENER FOUND CRACK AT STA 785.9, LBL 32.94 AREA. FWD CARGO BAY WING CTR TANK FRONT SPAR UPPER VERTICAL STIFFENER REPAIRED IAW R57-10-36821 & EO B767-5710-39644 JUST AT STA 785.9 LBLSDR IPXA10662335Pump · inoperativeCTR HYD SYS FLUID LOSS IN FLIGHT. CTR PUMP OUTPUT C1 3270 PSI OVER PRESS. NOT IN LIMITS. R & R C1 CTR HYD PUMP IAW AMM 29-11-02-4. OPS GOOD. NO LEAKS NOTED.SDR IPXA10662347Rib · crackedINSPECTION TYPE:C, RT WING NR 9 SLAT INBD NOSE SKIN SUPPORT RIB FOUND CRACKED JUST AT OSS 572.5, .0652" APPROX IN LENGTH. RT WING NR 9 SLAT INBD NOSE SKIN SUPT RIB REPAIRED WITH FREEZE PLUG & REPAIR STRAP INSTALL IAW RS R57-40-36815 & EO B767-5750-39486-A JUSSDR IPXA10662349Panel · misrepairedINSPECTION TYPE:C, LT WING NR 4 SLAT CLOSURE PANEL NON-STANDARD REPAIR HOT BOND REPAIR PERFORMED IAW SRM 51-70-17, PAR 4K, FIG 16, REV 47.SDR IPXA10662348Flap · misrepairedINSPECTION TYPE:C, RT WING INBD AFT FLAP INBD FWD CORNER NON-STANDARD REPAIR DOUBLER. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R. REPAIR 4, FIG 202, SHEET 1, REV 47.SDR IPXA10662346Fairing · delaminatedINSPECTION TYPE:C, RT WING OTBD T/E FLAP L/E FAIRING FOUND DELAMINATION. HOT BOND REPAIR PERFORMED IAW SRM 51-70-05 PAR 5A (1) FIG 5, REV 47.SDR IPXA10662140Skin · gougedRT SIDE FUSELAGE SKIN GOUGED AFT OF FWD LOWER CARGO DOOR AT STA 610R AND BETWEEN STRINGERS S30 & S29 RT. ACCOMPLISHED PERMANENT REPAIR OF SKIN DAMAGE AT STA 612 RT AND BETWEEN STRINGERS S30 AND S29 RT IAW SRM 53-00-15-1A-1, FIG 101, DETAIL II.SDR IPXA10662288Skin · crackedINSPECTION TYPE:C, RT WING NR9 SLAT INBD NOSE SKIN RIVET HOLE FOUND CRACKED. RT WING NR9 SLAT INBD NOSE SKIN REPAIRED IAW SRM 57-43-01-2R2, FIG 201, JUST AT OSS572.5 ORG MATL 7075T6-0063" CRACK LENGTH 0.164" DAMAGE CUTOUT 8.75" X 7.125" THIS IS CLASSIFIED AS SDR IPXA10662258Hinge Fitting · crackedINSPECTION TYPE:C, LT WING - INBD MAIN FLAP INBD HINGE FTG FOUND CRACK. LT WING INBD MAIN FLAP INBD HINGE FITTING, REPAIRED IAW SRM 57-53-02-2R1, FIG 201, ORG MATL 7075-T73 FORGING, CRK LENGTH AT INBD FLANGE IS 1.5" AND OTBD FLANGE IS 0.875" DAMAGE CUTOUT IS SDR IPXA10662327Stiffener · crackedINSPECTION TYPE:C, FWD CARGO COMPT WING CTR TANK FRONT SPAR UPPER VERTICAL STIFFENER CRACKED AT RBL 32.94, STA 782.9. FWD CGO COMPT WING CTR TANK FRONT SPAR UPPER VERT STIFFENER REPAIRED IAW RS R57-00-36812 & EO B767-5710-39487 JUST AT STA 785.9, RBL 32.94, OSDR IPXA10662324Floor Panel · damagedINSPECTION TYPE:C, MCD STA 830 TO 930 LBL 11 TO LBL 33, FLOOR PANEL FOUND 1 DAMAGED & 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662323Floor Panel · damagedINSPECTION TYPE:C, MCD STA 287 TO 412, LBL 33 TO LBL 55, FLOOR PANEL FOUND 2 DAMAGE & 6 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662314Floor Panel · damagedINSPECTION TYPE:C, MCD STA 720 TO 830 LBL 11 TO RBL 11 FLOOR PANEL FOUND 2 DAMAGED & 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662313Floor Panel · damagedINSPECTION TYPE:C, MCD STA 830 TO 930 LBL 11 TO RBL 11 FLOOR PANEL FOUND 1 DAMAGE & 10 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662312Floor Panel · dentedINSPECTION TYPE:C, MCD STA 930 TO 977, LBL 11 TO RBL 11 FLOOR PANEL FOUND 1 CRACK (5" LONG) & 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662311Floor Panel · damagedINSPECTION TYPE:C, MCD STA 874 TO 933, LBL 77 TO LBL 89, FLOOR PANEL FOUND 1 DAMAGE & 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662310Floor Panel · damagedINSPECTION TYPE:C, MCD STA 977 TO 1119 LBL 11 TO RBL 11, FLOOR PANEL FOUND 1 DAMAGE & DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662309Floor Panel · damagedINSPECTION TYPE:C, MCD STA 1480 TO 1604, LBL 11 TO RBL 11, FLOOR PANEL FOUND 1 DAMAGE & 8 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G & REINSTALLED IAW AMM 53-01-01.SDR IPXA10662084Skin · dentedFOUND ON WALKAROUND, RT OTBD FLAP BOTTOM HAS A DENT 7.5" X 4.5" IN DEEP AND A 3 IN DIAMETER BUBBLE. TEMPORARY REPAIR C/O IAW EO B767-5750-39284. REPETITIVE INSP REQUIRED AT (7) DAY INTERVALS UNTIL PERMANENT REPAIR OR PART REPLACEMENT IS ACCOMPLISHED WITHIN 60SDR IPXA10661875Sign · damagedINSPECTION TYPE:PS1, EMERGENCY EXIT LIGHT ASSY TABS TO HOLD LIGHT COVER ON WORN. R & R EMERGENCY LIGHT ASSY IAW MM 33-51-01-2.SDR IPXA10661854Element · inoperativeINSP TYPE:E TOP DIVERSION - RT DUCT LIGHT ILLUMINATED EICAS MSG RT BLD DUCT LEAK DISPLAYED LIGHT EXTINGUISHED AFTER ENG BLEED AIR SUPPLY AND ISOLATION VALVES CLOSED. FIM 26-18-00, FIG 104, FOLLOWED NO FAULTS PRECAUTIONARY REPLACEMENT OF FOLLOWING ITEMS IAW ASDR IPXA0661954Wedge · misrepairedINSPECTION TYPE:C, NON-STANDARD REPAIR ON LT WING NR1 SLAT UPPER SURFACE INBD T/E WEDGE AREA. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R REPAIR 4, FIG 202, SHEET 1, REV 47.SDR IPXA0661953Skin · delaminatedINSPECTION TYPE:C, LT WING NR1 SPOILER PANEL UPPER SURFACE DELAMINATED. GRAPHITE FABRIC WET LAY UP REPAIR CARRIED OUT IAW SRM 51-70-17, PAR 4A (1) FIG 10, REV 47.SDR IPXA0661952Fairing · delaminatedINSPECTION TYPE:C, LT WING INBD MAIN FLAP OTBD L/E FAIRING DELAMINATED FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PAR 5A (1) FIG 5, REV 47.SDR IPXA10661903Floor Panel · dentedINSPECTION TYPE:C, MCD STA 283 TO 412, RBL 77 TO RBL 89 FLOOR PANEL FOUND 1 GROOVE MARK AND 4 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10661540Pressure Switch · intermittentINSPECTION TYPE:E, TOP CTR HYD LOW SYS PRESSURE LIGHT ILLUMINATED ATB. REPLACED CTR HYDR SYS LOW PRESSURE SWITCH.SDR IPXA0661947Floor Panel · damagedINSPECTION TYPE:C, MCD STA 933 TO 985 RBL 77" TO RBL 89" FLOOR PANEL FOUND 1 DAMAGED & 6 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA0661946Floor Panel · damagedINSPECTION TYPE:C, MCD STA 985 TO 1087 RBL 77" TO RBL 89" FLOOR PANEL FOUND 1 DAMAGED & 7 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.
Back to Boeing 767-34AF