Boeing 767-3JHF
Service difficulty reports · 709
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673JHF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673JHF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR P5CA2020032700135Starter · inoperativeAPU INOP (AUXILIARY POWER UNIT (APU), ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60)(<P>TRANSFER TO MDDR 126307 IAW MEL 49-11-01A, CAT 'C'.</P><P>LP 1205568: T/S TO STARTER MOTOR. REMOVED AND REPLACED STARTER MOTOR ASSY IAW AMM 49-41-01. OPS CHK GOOD. THIS CSDR P5CA2020032500132Fire Warning · false activationL ENG FIRE LP 1 STATUS MESSAGE INTERMITTENT.(<P>CYCLED C/B'S AND THEN ENG FIRE DETECTION SYS OPERATIONAL TEST OK PER AMM 26-11-00. NO MSG NOTED.</P>)SDR P5CA2020030200059Oxygen Mask · inoperativeCENTER JUMPSEAT, OXYGEN MASK INOP.(<P>TRANSFERRED TO MDDR 125212 PER MEL 35-11-02-03A, CAT 'C', DUE DATE: 10MAR20. DISPATCH MZ@ 18:55Z.</P><P>LP 1102974: REMOVED AND REPLACED MASK ASSY, AND OXYGEN MASK/REGULATOR TEST NORMAL IAW AMM 35-11-15 AND 35-11-00. MDDR SDR P5CA2020022650057Diode · unknownAFT CARGO FIRE ARM LIGHT INOP.(<P>DEFERRED PER MEL 26-23-01, CAT C, MDDR 125081. </P><P>LP 1218496: REINSTALLED LWR AFT CARGO FIRE EXTINGUISHING ARM SWITCH FUSE/DIODE IAW AMM 33-13-00 AND LIGHT TESTS SATISFACTORY IAW AMM AMM 26-23-01. PERFORMED LOWER AFT CARGOSDR P5CA2020022500056Hook And Loop · missingVELCRO STRIPS ON GLARESHIELD ARE MISSING ON BOTH CAPTAIN AND FO SIDE. STRIPS ARE REQUIRED PER TA767-19-2.(<P>TRANSFERRED TO DMI 124942 IAW MEL 25-63-06, CAT D.</P>)SDR P5CA202002198046Skin · corrodedCORROSION - SKIN, L/H WING INBD AFT FLAP T/E UPPER SURFACE WBL 278.(<P>REMOVE THE DAMAGED MATERIAL AND CLEAN AND MEASURE THE DAMAGED AREA (L = 2.4", W = 0.75", D = 0.012", 8.25" FROM OUTBD EDGE, AT PNL T/E) BOND REPAIR DOUBLER (L = 6.9", W = 2.25", D = 0.025")SDR P5CA202002198047Rub Strip · corrodedCORROSION - WEAR STRIP, NO. 1 ENG R/H CORE COWL L/E OUTER SIDE, NEAR 2:00.(<P>REMOVE DAMAGED PARTS IAW SRM 51-40-02 REV. 76. INSTALL NEW PARTS IAW SRM 51-40-02 REV. 76 AND GOODRICH CMM 71-13-24 FIG 1 SH 1 OF 22 REV. 44. JOB COMPLETED AND CONDITION CHECK SATISFSDR P5CA202002198048Rub Strip · corrodedCORROSION - INNER SURFACE, NO. 2 ENG R/H T/R INTERIOR REAR UPPER WEAR STRIP. TOTAL = 4EA.(<P>REMOVE DAMAGED PARTS IAW SRM 51-40-02 REV. 76. INSTALL NEW PARTS IAW SRM 51-40-02 REV. 76 AND MRAS IPC 78-32-22 FIG. 7 SH6 REV. 83. JOB COMPLETED AND CONDITION CHECK SSDR P5CA202002198049Rub Strip · corrodedCORROSION - SURFACE, NO. 2 ENG R/H CORE COWL EXTERIOR FWD L/E WEAR STRIP. TOTAL 4EA.(<P>REMOVE DAMAGED PARTS IAW SRM 51-40-02 REV. 76 (OFF PARTS: PN 224-2301-71 & 224-2301-146). INSTALL NEW PARTS IAW SRM 51-40-02 REV. 76 AND GOODRICH CMM 71-13-24 REV. 44. JOB SDR P5CA202002198050Retainer · corrodedCORROSION - RETAINER, R/H MLG DOOR INBD SIDE SEAL RETAINER.(<P>DRILLED SCREW HOLES ON NEW RETAINER IAW SRM 51-40-02 AND SRM 51-40-05 REV. 76 AND DWG NO. 149T6906 SH01 REV. E SH02 REV. H SH03 REV. A. JOB COMPLETED AND CONDITION CHECK NORMAL. REMOVE/INSTALL REF SDR P5CA2020021900051Compressor · failedFUNCTION FAIL - HPC, FOUND NO. 2 ENG HPC BIT 18 CAN'T CHANGE FROM 1 TO 0 WHEN SUPPLY PRESSURE IS 10-18 PSI.(<P>IAW AMM 36-11-08-004-006-007 REV. 129 & AMM 36-11-08-404-014-007 REV. 129. REPLACED NO. 2 ENG HPC WITH SERVICEABLE PARTS. IAW AMM 36-11-08-404-014-0SDR P5CA2020021900052Valve · malfunctionedFUNCTION FAIL - PRVC, FOUND NO. 2 ENG PRVC REFERENCE PRESSURE LESS THAN 12 PSI WHEN SUPPLY PRESSURE IS 20 PSI. (<P>IAW AMM 36-11-19-004-001-002 REV. 129 & AMM 36-11-19-404-014-002 REV. 129 REPLACED NO. 2 ENG PRVC WITH SERVICEABLE PARTS. IAW AMM 36-11-19-404-01SDR P5CA2020021900053Start Valve · failedFOUND NO. 1 ENG START VALVE FUNCTION FAIL.(<P>IAW AMM 80-11-02-004-001 REV. 129 AND AMM 80-11-02-404-017 REV. 129 REPLACED NO. 1 ENG START VALVE WITH NEW PARTS. IAW AMM 80-11-02-404-017 REV. 129 STEP H PERFORMED START VALVE INSTALLATION TEST. TEST RESULT SATISSDR P5CA2020021900054Module · not reportedREMOVE AND REPLACE FAULTY AIR SUPPLY BITE MODULE.(<P>IAW AMM 36-23-01-004-001, 36-23-01-404-005 REV. 129 REPLACED THE AIR SUPPLY BITE MODULE. IAW AMM 36-23-00-715-001 REV. 129 PERFORMED THE AIR SUPPLY CONTROL SYSTEM BITE TEST. THE RESULT WAS SATISFACTORY.</P>)SDR P5CA2020021900055Packing · leakingLEAK - FWD NO. 2 ENG PRVC SENSING TUBE JOINT LEAKAGE.(<P>IAW AMM 36-11-19-004-001 REV. 129 AND AMM 36-11-19-404-014 REV. 129 REPLACED THE PACKING WITH SERVICEABLE PARTS AT NO. 2 ENG PRVC SENSING TUBE, IAW AMM 36-11-19-404-012 REV. 129 PERFORMED INSTALLATION TESDR P5CA2020021100024Heater · inoperativeEICAS "FO PITOT", ACCOMPLISHED QRH. NO SPEED DEVIATIONS NOTED.(<P>FOUND FO PITOT HEATER INOP. REMOVED AND REPLACED FO PITOT PROBE, THEN OPS CHECKED NORMAL PER AMM 34-11-01. NO MESSAGE FOUND. RII PROCEDURES C/W.</P>)SDR P5CA202001310023Control Valve · malfunctionedAPU SHUT DOWN DURING ENG START, UNABLE TO RESTART.(<P>TRANSFERRED TO MDDR 124080, APPLIED DDG 49-11-01B, CAT 'B'.</P><P><SPAN>LP 952758: REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW AMM 49-53-01. PERFORMED APU STARTING AND OPS CHECK OK, NO LEAKS. THIS CLEASDR P5CA2020013000022Start Valve · failedDURING ENG START, EICAS "R ENG STARTER" MESSAGE DISPLAYED. IAW AMM 80-11-02 REPLACED THE RT ENG START VALVE AND OPERATION TEST NORMAL.SDR P5CA2020012200016Skin · crackedRIGHT WING LOWER SKIN AT STRINGER 9.5 OUTBOARD OF WS 996.2 HAD TWO FASTENER HOLES CRACKED. REPAIRED IAW EO 6757A088 PART 4.SDR P5CA2020012200013Stringer · crackedBS 1702-1725 STRINGER 29L CRACKED. STRINGER REPAIRED IAW RI-53-80-13880 REV. ASDR P5CA2020012200014Skin · puncturedBS 1702-1725 BELOW STRINGER 26L TO STRINGER 30L SKIN PUNCTURED. SKIN REPAIRED IAW RI-53-80-13880 REV. A.SDR P5CA2020012200015Skin · crackedLHW LOWER SKIN AT STRINGER L9.5 OUTBOARD OF WSTA 996.2 TWO EACH FASTENER HOLES FOUND CRACKED. REPAIRED AS PER ATLAS AIR EO 6757A088 PART 3.SDR P5CA2020010980006Tru · failedAPU FAULTED AFTER THREE ATTEMPTS. IAW FIM 49-11 FT 987, 988, PERFORMED APU BITE TEST. FOUND BATTERY START APU OK, BUT APU TRU INOPERATIVE. APU START TRU REPLACED AND TESTED SERVICEABLE IAW AMM 24-32-04.SDR P5CA2020010800005Packing · damagedFUEL MINOR SEEPING FROM ENG 2 FUEL FILTER DIFF PRESSURE SWITCH JAM NUT.(<P>REMOVED AND REPLACED JAM NUT PACKING. OPS TEST GOOD AND NO LEAK FOUND IAW AMM 73-34-01.</P>)SDR P5CA2019123090238Controller · malfunctionedLEFT PACK RAM AIR INLET DOOR SECURED OPEN. L PACK TEMP, L PACK RESET SW INOP.(<P>TRANSFER TO MDDR 122670 IAW DDG 21-53-01A, CAT 'C', REMOVED AND REPLACED LEFT PACK INLET DOOR ACTUATOR PER AMM 21-53-03 AND PACK TEMP CONTROLLER PER AMM 21-51-14 LEFT PACK OPS CSDR P5CA2019122650235Controller · failedLEFT PACK TEMP APPEARED. FOUND LT PACK TEMP CONTROLLER DEFECTIVE BY SWAP CHECK, REMOVED AND REPLACED PACK TEMP CONTROLLER IAW AMM 21-51-14 AND OPS CHECKED NORMAL. NO MESSAGES.SDR P5CA2019121190226Packing · leakingFOUND FUEL SEEPING FROM ENG #2 FUEL FILTER DIFFERENTIAL SWITCH JAM NUT.(<P>REPLACED PACKING OF THE FUEL FILTER DIFFERENTIAL PX SW ON ENG 2, AND CHECKED NO LEAK FOUND IAW AMM 73-34-01.</P>)SDR P5CA2019120290223Pitot Tube · warning messageF/O PITOT EICAS UPON RIGHT ENGINE START.(<P>SERVICEABLE R/H UPPER PITOT/STATIC PROBE FITTED IAW AMM 34-11-01-409-017 REV 128. SUBSEQUENT PITOT/STATIC LEAK TEST C/W ON FO'S SYSTEM IAW AMM 34-11-00-862-045 REV 128, ALL OPS NOW NORMAL.<BR /></P>)SDR P5CA2019120280221Inlet · crackedFOUND ENG 1 INNER INLET COWL RIVET AREA CRACK (0.5" X 0.5") AT SIX O'CLOCK POSITION;REMOVED AND REPLACED L ENG INLET COWL IAW AMM 71-11-01. TAI DUCT LEAK CHECK SATISFACTORY.SDR P5CA2019112200218Connector · dirtyFOUND MAINT PAGE "IDG OUT TEMP".(<P>PER FIM TASK 24-20 FAULT TREE 807 FIG 103, BIT BPCU. FOUND LEFT IDG HIGH RISE TEMP, PERFORMED L/H IDG RECEPTACLE (010964) PIN/SOCKET CLEAN. CONDITION NORMAL AND MSG GONE.<BR /></P>)SDR P5CA2019102300212Skin · crackedCRACK - PFM SB AP 767-57-010 R12, FOUND RH WING LOWER SKIN HAD CRACK, NEAR WS 995, STR L - 9.5.(<P>ACCOMPLISHED J/C NO. 6757A088 PART 1-2, AND PART 4 REV.1. JOB COMPLETED AND CONDITION CHECKS NORMAL. </P><P><BR DATA-MCE-BOGUS="1" /></P><P>NOTE: CRACK LENGTH: 1SDR P5CA2019102300213Sensor · malfunctionedFOUND L/H ENG T25 SENSOR, CHANNEL A BLANK DURING ENGINE RUN.(<P>REMOVED AND REPLACED SENSOR IAW AMM 73-21-02-024-010 AND AMM 73-21-02-424-009 REV. 128. PERFORMED TEST NO.11 (EEC) STATIC TEST AND RESULT WAS SATISFACTORY IAW AMM 71-00-00-725-268 REV. 128. </P>)SDR P5CA2019101850209Warning Message · false activationIDLE DISAGREE MSG RECEIVED SEVERAL TIMES DURING DESCENT. RIGHT ENGINE AT APPROACH IDLE, LEFT ENGINE MINIMUM IDLE. MSG CLEARED AFTER ADVANCING LEFT ENGINE.(<P>RESET LEFT IDLE CONT. C/B AND CONFIRMED THERMAL ANTI-ICE HIGH LEFT SYSTEM NORMAL. IDLE DISAGREE MSG DISDR P5CA2019100750205Wire Harness · damagedENG #1 IS INDICATING INTERMITTENT VIBRATION READING FROM THE CORE MOUNTED ACCELEROMETER PER W/O 57411.(<P>REMOVED & REPLACED VIBRATION WIRE HARNESS FROM D4208P TO D10986. ENG RUN, NO FAULT DETECTED, AND AVM BITE TEST CHECKED OK PER WDM 77-31-11, AMM 71-00-00-2SDR P5CA2019091001203Controller · malfunctionedLEFT PACK OFF LIGHT OCCURRED DURING T/O ROLL UNTIL 80 KNOTS AND DURING DESCENT BELOW 8000 FEET. REMOVED AND REPLACED LEFT PACK TEMP CONTROLLER AND BITE TEST OK PER AMM 21-51-14/401. LEFT PACK OPERATION NORMAL. REMOVED AND REPLACED LEFT PACK FLOW CONTROL AND SDR P5CA2019092600201Warning System · false activationL PACK TRIPPED WITH L PACK OFF EICAS MSG. PACK RESET ITSELF BEFORE QRH PROCEDURES WAS ADDRESSED.(<P>ACCOMPLISHED OPS CHECK AND FOUND L PACK WORKS NORMAL IAW AMM 21-00-00.</P>)SDR P5CA2019092600200Warning System · false activationL PACK TRIP AND EICAS MSG. RESET PACK AND IT TRIPPED AGAIN, OPS OK IN STBY.(<P>L AND R PACK TEMP CONTROLLERS INTERROGATED, NO FAULTS EVIDENT, TESTED OK PER AMM 21-62-00. NO FAULTS EVIDENT WITH ZONE TEMP CONTROLLER, TESTED OK PER AMM 21-61-00.</P>)SDR P5CA2019091700184Filter · cloggedAFTER TAKEOFF, FLIGHT DECK AUTO TEMP CONTROLLER WENT FULL COLD. AS PER AMM 21-61-03, ZONE TEMPERATURE CONTROL BITE TEST VERIFIED NO FAULTS. CLEARED FLIGHT DECK TEMPERATURE SENSOR AND BULB PER AMM 21-61-00. FOUND FLIGHT DECK TEMP SENSOR/BULB, FORM FILTER CLOGGESDR P5CA2019090300177Smoke Detector · faulty"AFT CARGO DET 2" STATUS MESSAGE. TRANSFER TO MDDR #117243 IAW DDG 26-16-01-01, CAT C. LP 1115146 - ITEM 1: C/W FIM 26-16 FT 816, REMOVED AND REPLACED AFT CARGO SMOKE DETECTOR # 2. PERFORMED OPERATIONAL TEST, CONDITION CHECKS NORMAL IAW AMM 26-16-01. THIS CLOSDR P5CA2019083100176Smoke Detector · dirtyAFT CARGO DET 2 INOP. ITEM DEFERRED PER MEL 26-16-01-01-01, CAT C, MDDR 117149. PLACARD INSTALLED AND MCC NOTIFIED. LP 1115135 - M9: CLEANED AFT CARGO SMOKE DETECTOR NR 2 AND PERFORMED LWR CARGO COMPT SMOKE DETECTION SYSTEM OPERATIONAL TEST IAW AMM 26-16-00. OSDR P5CA2019083000175Smoke Detector · dirtySTATUS MESSAGE FOR AFT CARGO DET 2. CHECKED AND CLEANED SMOKE DETECTOR HOLES. PERFORMED OPERATIONAL TEST, CONDITION CHECKS NORMAL IAW AMM 26-16-00.SDR P5CA2019082760174Tru · failedFOUND P32 APU START TRU CIRCUIT BREAKER TRIPPED. REMOVED AND REPLACED APU START TRU AND OPERATIONAL CHECKED GOOD IAW AMM 24-32-04.SDR P5CA2019082200173Seal · leakingNR 1 ENG DRAIN LINE CHECK IAW AMM 71-00-00, STARTER DRAINED 30 CC, IDG DRAINED 60 CC. HYD PUMP, FUEL PUMP, AND HMU DRAINED 0 CC. ITEM M6: LEFT ENGINE IDG AND STARTER DRAIN LINES CAPPED FOR SEAL REPLACEMENT WITHIN 10 FLIGHT CYCLES PER ECM 2019-342. REMOVED ANDSDR P5CA2019082090172Boot · leakingDUCT BOOTS HAS AIR LEAK FROM APU SURGE BLEED VLV EXH SIDE.(<P>REMOVED AND REPLACED DUCT BOOTS AT APU SURGE BLEED VLV EXH SIDE AND LEAK CK OK IAW AMM 49-11-00-201.</P>)SDR P5CA2019081640169Warning Message · false activationENROUTE: L & R UTIL BUS EICAS MESSAGE. CLEARED AFTER QRH PROCEDURE. ACCOMPLISHED BPCU BITE TEST PER AMM 24-21-00-501. FOUND NO FAULTS.SDR P5CA2019080860165Transmitter · malfunctionedAPU OIL QTY STS MSG. INSPECTED APU OIL LEVEL SIGHT GLASS, CONFIRMED OIL IS AT FULL LEVEL POSITION. REMOVED AND REPLACED APU OIL QTY TRANSMITTER IAW AMM 49-94-04. C/W SERVICING FOR THE APU OIL RESERVOIR IAW AMM 49-27-00. PERFORMED APU OPERATIONAL CHECK IAW AMSDR P5CA2019072600158Controller · malfunctionedDURING CLIMB, "R ENG HPSOV" CAUTION MESSAGE INDICATED, COMPLIED WITH QRH. (<P>ITEM DEFERRED TO MEL 36-11-02-02. MAINT PROCEDURE COMPLIED WITH. NOTIFIED MCC, PLACARDS INSTALLED, MDDR 115328.</P><P>LP 924200 - M4: PERFORMED AIR SUPPLY BITE TEST. REMOVED AND REPSDR P5CA2019071100146Warning System · false activationR ENG FIRE LP 1 STATUS MSG. (<P>PLACED OM MDDR 114591 PER MEL 26-11-01-01.</P><P>LP 924163 - M11: PFM ENG FIRE DETECTION SYSTEM OPERATIONAL TEST AND FOUND CONDITION SATISFACTORY IAW AMM 26-11-00-715-001 REV. 127. CLOSED MDDR 114591 AND MCC NOTIFIED.</P>)SDR P5CA2019071200148Warning System · false activation"AFT CARGO DET-2 INOP ( LOWER CARGO COMPARTMENT FIRE DETECTION SYSTEMS / (FWD AND AFT), DETECTORS, -200/-300 )"(<P>ITEM DEFERRED PER MEL 26-16-01-01-01, CAT 'C', DUE 20-JUL-19. MDDR #114492. MCC NOTIFIED AND PLACARD INSTALLED. <BR /></P><P>LP 954646 - NO STATUSDR P5CA2019070400143Seal · unknownREPLACE ENGINE 1 STARTER CARBON SEAL. REMOVED ENGINE 1 STARTER IAW AMM 80-11-01. REPLACED ENGINE 1 STARTER CARBON SEAL IAW AMM 72-64-02. REPLENISHED STARTER OIL IAW AMM 12-13-02. PERFORMED ENGINE IDLE LEAK TEST #3 N2 80% SATISFACTORY.
Back to Boeing 767-3JHF