Service difficulty report · Filter · Boeing 7673JHF

Difficulty date
September 16, 2019
Submitted
September 18, 2019
Operation
Air carrier
Aircraft
N644GT
Make and model
Boeing 7673JHF
Aircraft serial
37810
Aircraft time
16,247 hours, 3,920 cycles
Part
Filter
Part number
215T14182
Condition
Clogged
Location
Cockpit Temp
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, FLIGHT DECK AUTO TEMP CONTROLLER WENT FULL COLD. AS PER AMM 21-61-03, ZONE TEMPERATURE CONTROL BITE TEST VERIFIED NO FAULTS. CLEARED FLIGHT DECK TEMPERATURE SENSOR AND BULB PER AMM 21-61-00. FOUND FLIGHT DECK TEMP SENSOR/BULB, FORM FILTER CLOGGED. REMOVED AND REPLACED FILTER AS PER AMM 21-61-09. OPERATIONAL CHECK OF FLIGHT DECK TEMP CONTROL, TEMP CONTROL NORMAL AS PER AMM 21-61-00.