Boeing 767-3S1

Service difficulty reports · 974

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '7673S1'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UIEA2014071900333Filter · faultyRIGHT ENG FUEL FILTER STATUS MSG. REPLACED RT ENG FUEL FILTER IAW AMM 73-11-02, NO LEAKS NOTED.Jul 19, 2014 · N640GT · Boeing 7673S1 · Engine Fuel DistributionSDR UIEA2014070100351Idg · lowSTATUS MESSAGE RT IDG VLV. INSPECTED RT ENG IDG COOLING VLV & PNEU FILTER IAW AMM 24-11-07. SERVICED IDG IAW AMM 12-13-03, INSPECTED CONNECTOR TO VLV, NOTED NO DEFECT. ENG RUN NO FAULT PRESENT IAW AMM 71-00-00.Jul 1, 2014 · N640GT · Boeing 7673S1 · AC Generator-AlternatorSDR UIEA2014070100289Warning System · false activationSTATUS MSG RT IDG VLV. CLEARED MSG & RAN ENGS IAW MM 71-00-00, NO FAULTS NOTED.Jul 1, 2014 · N640GT · Boeing 7673S1 · Central WarningSDR UIEA2014062800306Cover · missingFORWARD LT LAVATORY WASTE CONTAINER TOP COVER IS MISSING FROM ACFT. FABRICATED LT LAVATORY WASTE CONTAINER TOP COVER FROM 2024 T3. 032 & INSTALLED. ALL WORK ACCOMPLISHED IAW SRM 51-20-02, 51-30-01 & AMM 26-24-01.Jun 30, 2014 · N640GT · Boeing 7673S1 · LavatoriesSDR UIEA2014062800305Fastener · missingMID CTR LAVATORY, MID RT LAVATORY & AFT RT LAVATORY EACH MISSING ONE FASTENER FROM WASTE CONTAINER TOP COVER. INSTALLED NEW FASTENERS IN MID CTR LAVATORY, MID RT LAVATORY & AFT RT LAVATORY WASTE CONTAINER TOP COVER IAW AMM 20-11-00.Jun 30, 2014 · N640GT · Boeing 7673S1 · LavatoriesSDR UIEA2014073000308Sign · unsecureRIGHT FWD OVERWING HATCH, EXIT SIGN IS UNSECURE. SECURED RT FWD OVERWING HATCH EXIT SIGN IAW AMM 33-51-01.Jun 30, 2014 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2014062200247Connector · dirtyAPU DID NOT START ON GND. OIL LEVEL WITHIN LIMITS, BITE IAW FIM 49-11, FT 958, IGN UNIT LIGHTED. CLEANED CONNECTOR D40245 & CONNECTOR ON M1 IGNITER UNIT, FAULT CLEARED. STARTED NORMAL, OPERATIONS CHECKED NORMAL AT THIS TIME. CONNECTOR CLEANED IAW SWPM 20-00Jun 22, 2014 · N640GT · Boeing 7673S1 · APU System WiringSDR UIEA2014061900238Light · inoperativeAFT RT OVERWING EMER ESCAPE LIGHT INOPERATIVE. EXTERIOR RELAMPED IAW AMM 33-51-06.Jun 19, 2014 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2014060500224Connector · dirtyBTB DUE LT PACK FAIL. PACK BEGIN WORKING ON TAXI IN, PERFORMED FIM 21-51 FT 803, NO FAULTS FOUND. REMOVED, CLEANED & REINSTALLED CONNECTOR FOR FLOW CONTROL VLV, LT PACK OPERATIONS CHECKED GOOD AT THIS TIME.Jun 5, 2014 · N640GT · Boeing 7673S1 · Air Conditioning System WiringSDR UIEA2014052800219Warning System · false activationLEFT EICAS STATUS MSG, LT ENG CONTROL. REMOVED CONNECTORS FROM EEC & RESEATED CONNECTIONS PERFORMED FIM PROCEDURES IAW FIM 73-21 & FIM 73-21-805 THE SYS.May 28, 2014 · N640GT · Boeing 7673S1 · Engine Fuel System WiringSDR UIEA2014051200174Light · missingMDDR 48004 RT AFT DOOR R4, DOOR ARMED INDICATOR MISSING MAINT LIGHT. INFORM FLIGHT CREW DOOR IS ARMED BEFORE EACH DEPARTURE, DMI 48004 L4 DOOR INDICATOR. R & R RT AFT SERVICE DOOR VISUAL ARMING INDICATOR. PERFORMED SATISFACTORY PSEU DOOR VERIFICATION TEST SMay 12, 2014 · N640GT · Boeing 7673S1 · Service DoorsSDR UIEA2014051300183Screw · brokenBROKEN SCREWS ON RT AFT OVERWING EMERGENCY LIGHT L390. R & R SCREWS IAW SRM 51-40-02.May 12, 2014 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2014051300182Cam Lock · brokenRIGHT FWD EMERGENCY EXIT TOP ACCESS PANEL FWD CAM LOCK IS BROKEN. R & R CAM LOCK IAW SRM 51-40-02.May 12, 2014 · N640GT · Boeing 7673S1 · Emergency ExitsSDR UIEA2014051300181Circuit Card · faultyAFTER POWER SHUTDOWN, AURA 1 WARNING SOUNDS UNTIL STANDBY POWER SWITCH SHUTOFF. TROUBLE SHOT IAW WDM 24-33-11, 34-34-34 & 31-51-41 REPLACED M620 TAKEOFF WARNING CARD IN P51 PANEL IAW 31-51-04. OPERATIONS CHECK PERFORMED SATISFACTORY IAW 31-51-00.May 12, 2014 · N640GT · Boeing 7673S1 · Central WarningSDR UIEA2014051300180Spring · missingAPU SURGE VLV FILTER ELEMENT SPRING IS MISSING FROM BETWEEN THE FILTER ELEMENT & THE REDUCER. INSTALLED SPRING PN 663466 FOR APU SURGE VLV FILTER ELEMENT & THE REDUCER IAW AMM 49-53-06. LEAK CHECK ACCOMPLISHED WITH NO LEAKS NOTED.May 12, 2014 · N640GT · Boeing 7673S1 · APU Bleed Air SystemSDR UIEA2014051300179Igniter · wornAPU IGNITER PLUG REQUIRED REPLACEMENT DUE TO WEAR. R & R APU IGNITER PLUG IAW AMM 49-41-02.May 12, 2014 · N640GT · Boeing 7673S1 · APU Start/Ignition SystemSDR UIEA2014051300178Blade · erodedENG 2 FAN BLADES LE TOWARD TIP HAVE EROSION. BLENDED SMALL NICKS AT VARIOUS FAN ROTOR BLADES ON ENG 2 IAW 72-31-02, NO FURTHER DEFECTS NOTED.May 12, 2014 · N640GT · Boeing 7673S1 · Turbine Engine Compressor SectionSDR UIEA2014051300177Guide Vane · delaminatedENG 2 OUTLET GUIDE VANE, AFT OF FAN, AT 0900 POSITION, NEEDS LE TAPE. INSPECTION FINDS DELAMINATION WITHIN ALLOWED LIMITS IAW AMM 72-33-00. APPLIED REPAIR WITH APPROVED TAPE IAW AMM 72-33-00-228-046-H00.May 12, 2014 · N640GT · Boeing 7673S1 · Turbine Engine Compressor SectionSDR UIEA2014051200172Light · intermittentRIGHT AFT OVERWING EGRESS LIGHT L390 FWD LAMP IS INTERMITTENT. REPLACED LAMPS IAW AMM 33-51-06. REPLACED GND TERMINAL LUG IAW SWMP 20-20-10, CLEARED LIGHT ASSEMBLY IAW AMM 20-60-02. OPERATIONS CHECKED GOOD IAW AMM 33-51-06.May 12, 2014 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2014042900159Warning System · false indicationAPU FUEL VLV EICAS MSG, NO MSG AT THIS TIME, CREW REPORT 2ND ATTEMPT NORMAL. PERFORMED BITE IAW FIM 49-11 958 IAW FIM 28-25 805, APU START NORMAL IAW AMM 49-11-00, NO FAULT FOUND ON BITE CHECK.Apr 29, 2014 · N640GT · Boeing 7673S1 · APU Indicating SystemSDR UIEA2014041200146Relay · failedAPU AUTO SHUTDOWN ON GROUND. ECU FAULTED & DOOR SYSTEM EICAS MESSAGE, APU FAULT. R & R DOOR CONTROL RELAY SYS. OPS CHECKED GOOD IAW AMM 49-30-00.Apr 12, 2014 · N640GT · Boeing 7673S1 · APU ControlsSDR UIEA2014041100143Actuator · malfunctionedLT PACK TEMP EICAS MSG. TROUBLE SHOT IAW FIM 21-51T803. RESET FAULT PACK RAM AIR OUTLET ACT, CHECKED GOOD. REPLACED EXHAUST ACTUATOR AS PRECAUTIONARY.Apr 11, 2014 · N640GT · Boeing 7673S1 · Cabin Cooling SystemSDR UIEA2014041000142Smoke Detector · defectiveDURING DAILY CHECK FOUND EICAS MSG FWD CARGO SMOKE DETECTOR 2. REPLACED SMOKE DETECTOR.Apr 10, 2014 · N640GT · Boeing 7673S1 · Smoke DetectionSDR UIEA2014040600138Actuator · faultyLT PACK OFF LIGHT WILL NOT EXTINGUISH. REPLACED LT PACK RAM AIR EXHAUST ACTUATOR IAW AMM 21-53-02. THIS CLEARS DMI 47403 & MEL 21-51-01-01.Apr 6, 2014 · N640GT · Boeing 7673S1 · Cabin Cooling SystemSDR UIEA2014032600128Radar · malfunctionedWEATHER RADAR INOPERATIVE. PERFORMED FAULT ISOLATION PROCEDURE IAW FIM 34-43 FAULT TREE BK 1 & 2, SYS OK.Mar 26, 2014 · N640GT · Boeing 7673S1 · Weather Radar SystemSDR UIEA2014032700129Antenna · malfunctionedWX RADAR CHECK DURING TAXI OF THE TILT KNOB FROM 0 TO FULL DOWN, UNABLE TO PAINT GROUND RETURNS IN LT & RT SYS IN WX & WX T AT ALL LEVELS OF GAINS WITH & ELT'S SPRS OFF. REPLACED ANTENNA IAW AMM 34-43-05, OPS CHECKED NORMAL,Mar 26, 2014 · N640GT · Boeing 7673S1 · Weather Radar SystemSDR UIEA2014031200102Actuator · failedLEFT PACK BITE STATUS MESSAGE ON EICAS. PERFORMED BITE CHECK, FOUND LT INLET ACTUATOR FAIL. REPLACED LT PACK INLET ACTUATOR IAW AMM 21-53-03, OPERATIONS CHECKED OK.Mar 11, 2014 · N640GT · Boeing 7673S1 · Cabin Cooling SystemSDR UIEA2014031100101Thermocouple · faultyEICAS MX MSG, APU BITE, LRU FAULTED NR 2 EGT CIRCUIT. PERFORMED APU BITE IAW 49-11 FAULT TREE 958 MINI FLAG 12, FAULTED LRU NR 2 EGT CIRCUIT. R & R RT SIDE THERMOCOUPLES POSITION TS7 UPPER & TS7 LOWER IAW AMM 49-71-01-401. SN OFF UPPER 1115027701662, SN ON Mar 10, 2014 · N640GT · Boeing 7673S1 · APU Indicating SystemSDR UIEA2014030900097Unknown · malfunctionedEICAS MX MSG FUEL QTY BITE. PERFORMED FUEL QTY BITE CHECK IAW MM 28-41-00-715-032-001. PN S345T002-60 INSTALLED, NO FAULTS NOTED ON CHANNEL 1 OR CHANNEL 2, SYS NORMAL.Mar 9, 2014 · N640GT · Boeing 7673S1 · Fuel Quantity IndicatorSDR UIEA2014030300093Pressure Switch · inoperativeLEFT AFT PRESS LIGHT FOR LT AFT BOOST PUMP INOPERATIVE. NOTE WITH BOTH LT PUMP INOPERATIVE WITH BOTH LT PUMP OFF ASSOCIATED LT SYS PRESS ON EICAS NOT PRESENT. REPLACED LT AFT FUEL BOOST PUMP PRESS SWITCH IAW AMM 28-42-01, OPERATIONS CHECKED NORMAL.Mar 3, 2014 · N640GT · Boeing 7673S1 · Aircraft Fuel Distribution SystemSDR UIEA2014030300092Indication Sys · malfunctionedSTATUS MESSAGE CABIN ALT AUTO 2. PERFORMED FIM BITE PROCEDURE IAW FIM 21-31. FAULT TREE 807 CLEARED FAULT. PERFORMED VERIFY ALL CHECK PASSED, SYS CHECKED OK.Mar 3, 2014 · N640GT · Boeing 7673S1 · Cabin Pressure Control SystemSDR UIEA2014030200091Indication Sys · malfunctionedLEFT CTR FUEL PUMP PRESS LIGHT & CTR LT FUEL PUMP EICAS ON TAKEOFF & CLIMB OUT. COMPLETED QRH, PERFORMED FIM PROCEDURE IAW FIM 28-22 FAULT TREE 805 FUEL PUMP & PRESS SWITCH. PRESS NORMAL NO FAULT NOTED ON GROUND.Mar 2, 2014 · N640GT · Boeing 7673S1 · Fuel Indicating SystemSDR UIEA2014022100077Shutoff Valve · stickingNUMBER 1 ENG PRSOV INTERMITTENTLY STICKS IN INTERMEDIATE POSITION. REPLACED LT ENG NR 1 PRSOV IAW AMM 36-11-09, OPERATIONS CHECKED NORMAL & LEAK CHECKED NORMAL.Feb 20, 2014 · N640GT · Boeing 7673S1 · Pneumatic Distribution SystemSDR UIEA2014020200043Controller · faultyIN CRUISE LT & RT DUCT PRESS SPLIT, LT 25 & RT 35. REPLACED LT ENG PRV CONTROLLER IAW AMM 36-11-19, LEAK CHECKED & OPERATIONS CHECKED GOOD, NO LEAKS NOTED.Feb 2, 2014 · N640GT · Boeing 7673S1 · Pneumatic Distribution SystemSDR UIEA2014012700036Light · inoperativeEMERGENCY EXIT LIGHT BY R2 DOOR FLOOR LINE HAS SOME BULBS INOPERATIVE. R & R ALL EMERGENCY EXIT LIGHT BULBS IAW AMM 33-51-01.Jan 25, 2014 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2014012700037Socket · dirtyEMERGENCY LIGHT LT SIDE OF FUSELAGE AFT OF FLAPS INOPERATIVE. DURING TEST PERFORMED LAMP SOCKET CLEANING, SLIDE & OVERWING ESCAPE LIGHTS. OPERATIONS CHECKED NORMAL IAW AMM 33-51-06 201.Jan 25, 2014 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2014011400010Controller · malfunctionedLEFT PACK INOPERATIVE LIGHT ON IN AUTO POSITION. R & R LT PACK TEMP CONTROLLER IAW AMM 21-51-14, OPERATIONS OK.Jan 14, 2014 · N640GT · Boeing 7673S1 · Cabin Cooling SystemSDR UIEA2014011300009Hose · damagedHOSE & ELBOW ASSEMBLY DAMAGED ON PRESS REGULATING VLV & NBSP. R & R HOSE & ELBOW ASSEMBLY, LEAK CHECKED GOOD.Jan 13, 2014 · N640GT · Boeing 7673S1 · Pneumatic Distribution SystemSDR UIEA2014011000006Shutoff Valve · malfunctionedON DECENT LT BLEED VLV DUCT PRESS DROPPED MORE THAN 10 PSI & HAD FLUCTUATION OF 5 PSI DIFFERENCE. REPLACED PRSOV IAW 767 AMM 36-11-09, OPERATIONS CHECKED NORMAL.Jan 10, 2014 · N640GT · Boeing 7673S1 · Pneumatic Distribution SystemSDR UIEA2013112000565Light · inoperativeCOCKPIT OVER DOOR EMERENCY EXIT SIGN DOES NOT ILLUMINATE. REPLACED COCKPIT, OVER DOOR EMERGENCY LIGHTED EXIT SIGN IAW AMM 33-51-01, TESTED LAMPS IAW 33-51-01; TESTED EMERG LIGHTING IAW AMM 33-51-00 ALL TEST PASS.Nov 18, 2013 · N640GT · Boeing 7673S1 · Emergency LightingSDR UIEA2013102500537Skin · delaminatedLEFT ENGINE INLET COWL DELAMINATION AT 06:00 POSITION, AT AFT EDGE. (PERFORMED TIME LIMITED REPAIR ON LT ENGINE INLET COWL IAW EO 6771A004.)Oct 25, 2013 · N640GT · Boeing 7673S1 · Nacelle/Pylon, Plate/SkinSDR UIEA2013102400533Wire · damagedFORWARD CARGO HANDLING CIRCUIT BREAKER C173 TRIPPED LT POWER DRIVE UNIT. FOUND DAMAGED WIRES 6 INCHES FROM CONNECTOR D11092. REPLACED CONNECTOR, D11092 AND WIRES FROM CONNECTOR TO GROUND GD4762 AND SPLICED; REMAINING WIRES IAW BWDM 25-53-14, PAGE 8, SHEET 4 Oct 24, 2013 · N640GT · Boeing 7673S1 · Electrical Power System WiringSDR UIEA2013102400536Module · leakingBLEED AIR LEAK ON FLOW SENSING MODULE (APU)(CLEANED AND INSTALLED GASKET BETWEEN FLOW SENSING MODULE AND MOUNT HOUSING, IAW AMM 49-53-08. NO LEAKS NOTED AT THIS TIME AND APU FLOW SENSING MODULE.)Oct 24, 2013 · N640GT · Boeing 7673S1 · APU Bleed Air SystemSDR UIEA2013102100532Module · looseAPU BLEED AIR LOW PRESSURE IN ALL MODES (DUCT PRESSURE) ON GROUND. PRESSURE LOW WITH APU AS THE AIR SOURCE. TIGHTEN BOLTS ON FLOW SENSING MODULE IAW AMM 49-53-05, DUCT PRESSURE. OPS CK NORMAL, REF FIM 49-11, TREE 980, BLK 51.Oct 21, 2013 · N640GT · Boeing 7673S1 · APU Bleed Air SystemSDR UIEA2013102000531Exciter · failedAPU DID NOT START AFTER 3 ATTEMPTS ON GROUND. (PERFORMED APU BITE ON ECU; FAULTED "IGN UNIT", IAW FIM 49-11, R & R IGN EXCITER UNIT IAW AMM 49-41-03; R & R IGNITOR IAW AMM 49-41-02, OPS CKD NORMAL).Oct 19, 2013 · N640GT · Boeing 7673S1 · APU Core EngineSDR UIEA2013101800528Controller · inoperativeRT FWD WINDOW HEAT INOPERATIVE. REPLACED RT FWD F/O'S NR 1 WINDOW HEAT CONTROLLER IAW AMM 30-41-01, OPS CHECKED NORMAL.Oct 18, 2013 · N640GT · Boeing 7673S1 · Windshield/Door Rain/Ice RemovalSDR UIEA2013101700526Pressure Switch · failedLEFT FWD BOOST PUMP PRESSURE LIGHT DOES NOT ILLUMINATE WHEN DESELECTED IN FLIGHT APU OFF. R & R LT FWD FUEL BOOST PUMP PRESSURE SWITCH IAW AMM 28-41-01. OPS CHECKED GOOD.Oct 17, 2013 · N640GT · Boeing 7673S1 · Fuel Boost PumpSDR UIEA2013091700502Pressure Switch · failedAFTER ENGINE SHUTDOWN, LT SYS DEMAND PUMP DID NOT WORK IN AUTO. TROUBLESHOT IAW WPM 29-11-12, PG 1,2,3. FOUND S26 EDP PRESSURE SWITCH FAULTY. R & R PRESSURE SWITCH, OPS CHECKED NORMAL IAW AMM 29-11-18-401, LEAK CHECKED OK.Sep 17, 2013 · N640GT · Boeing 7673S1 · Hydraulic Pump (Electric/Engine), MainSDR UIEA2013091000500Warning Light · illuminated"LT ENG EEC C2 " ; LT PIMU MX MESSAGE. PERFORMED BITE OF PIMU IAW FIM 71-01 FT 810, NO FAULTS , RAN ENGINE, ALL INDICATIONS NORMAL, LT EEC C2; PIMU MSG CLEARED.Sep 8, 2013 · N640GT · Boeing 7673S1 · Fuel Control/Turbine EnginesSDR UIEA2013090500497Ground Wire · looseMAIN BATTERY CHARGER STATUS MESSAGE. ACCOMPLISHED FIM 24-31 FAULT TREE 803 THRU BLOCK 23, TERMINATED GROUNDS GD4588 AND GD4590 IAW SWPM 20-30-11 REF WDM 24-34-11, PG 7 SHEET 2, OPS CHECK NORMAL.Sep 5, 2013 · N640GT · Boeing 7673S1 · Battery/Charger System
Back to Boeing 767-3S1