Boeing 767-3S1
Service difficulty reports · 974
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673S1' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673S1' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020062971414Apu · malfunctionedAPU STARTED ON THIRD ATTEMPT, UNABLE TO START APU INFLIGHT. PERFORMED BITE ON APU ECU, NO FAULTS NOTED. APU START AND OPS NORMAL IAW AMM 49-61-05-201.SDR UIEA2020062601402Bpcu · malfunctionedAPU GEN FAIL. REMOVED REPLACED BPCU, APU GEN OPS CHECK OK ON ENG RUN, NO FAILT NOTED IAW AMM 24-41-03, 71-00-00, AND 24-21-00. THIS CLEARS DMI 130294. PLACARD REMOVED. MCC NOTIFIED, T/I DL 0717.SDR UIEA2020062201328Shutoff Valve · malfunctionedSTATUS MSG L ENG HPSOV. REMOVED AND REPLACED LT ENG HPSOV IAW AMM 36-11-07-024/424, LEAK TEST IAW AMM 71-00-00/201, BITE CHK AIR SUPPLY MODULE GOOD IAW AMM 36-23-00/501.SDR UIEA2020062201335Lens · damagedL1 DOOR EMERGENCY LIGHT LENS DAMAGED (NON-ESSENTIAL EQUIPMENT & FURNISHINGS(NEF) (120 DAYS)(NEW NEF 2ND QTR 2020). REMOVED AND REPLACED MISSING LIGHT LENS PER AMM 33-51-03. THIS CLEARS MDDR 130024. PLACARD REMOVED.SDR UIEA2020062301343Idg · underservicedLEFT GENERATOR DRIVE EICAS MESSAGE. ACCOMPLISHED NNC, SERVICED THE LT IDG IAW AMM 12-13-03/301. PERFORMED AN OPS TEST IAW AMM 71-00-00-301. OPS TESTED GOOD IAW AMM 24-11-00-715.SDR UIEA2020062201327Warning System · false activationSTATUS MESSAGE LEFT ENGINE HPSOV PERFORMED FIM 36-10 FT833, PERFORMED AIR SUPPLY BITE PROCEDURE 36-20-00 /106. NO FAULTS NOTED, PREFORMED ENG RUN LT IAW AMM 71-00-06. NO FAULTS NOTED.SDR UIEA2020061871298Actuator · malfunctionedRIGHT OVERWING SLIDE DOOR OPENED INADVERTENTLY. REMOVED AND REPLACED THE LT AND RT ACTUATOR SPOILER OVERRIDE IAW AMM 25-65-20. REMOVED AND REPLACED RT SLIDE COMPARTMENT DOOR LATCH OPENING ACTUATOR. AMM 25-65-11.SDR UIEA2020061871304Battery · inoperativeR1 DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE R1 DOOR EMERGENCY POWER BATTERY PACK IAW AMM 33-51-07. FOUND WIRES CHAFING IN HARNESS LOCATED IN CEILING, REPAIRED IAW SWPM. OPERATIONAL CHECKED NORMAL.SDR UIEA2020061701303Valve · malfunctionedAPU DUCT PRESSURE LOW. REMOVED AND REPLACED AIR SUPPLY BITE MODULE, NO HELP, APU DUCT PRESS STILL LOW. LOCKED OUT VALVE. IAW AMM 36-11-00 REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW AMM 49-53-01. OPS CHECKED GOOD.SDR UIEA2020061101278Transceiver · inoperativeWX FAIL MESSAGE ON EHSI AFTER TAKE OFF WITH RIGHT RADAR SELECTED ON. REMOVED AND REPLACED WX RADAR ANTENNA M269, OPS CHECK WX RADAR SYS, OK. AMM 34-43-05, REMOVED AND REPLACED RIGHT WXR TRANSCEIVER IAW AMM 34-43-01-004/404. OPS TESTED GOOD IAW AMM 34-43-01-5SDR UIEA202006151273Radar · malfunctionedWXR SYS STATUS MESSAGE, BOTH LT & RT WXR FAIL AFTER TAKE OFF. CAPTAIN`S SWITCH ON/OFF BOTH CAME BACK UP. PERFORMED GROUND TEST. NO DEFECTS NOTED. IAW AMM 34-43-00.SDR UIEA2020060109256Radar · malfunctionedWXR SYS STATUS MSG R WXR FAIL AFTER TAKE OFF, SWITCHED TO LT THEN BACK TO RIGHT AND WXR RIGHT WORKED NORMAL. PERFORMED OPS CHECK ON GROUND IAW AMM 34-43-00. RT SYS OPS CHECKED NORMAL.SDR UIEA2020060601218Ecu · malfunctionedAPU WILL NOT START. TRANSFERRED TO MDDR 129335, MEL 49-11-01B, CAT "B", DD: 09JUN20, PLACARD INSTALLED. ETOPS 120 ONLY. RESET ECU. OPS CKS GOOD. CLOSED MDDR 129335.SDR UIEA2020060801238Controller · malfunctionedREPEAT WRITE-UP RT PACK TEMP EICAS. REMOVED AND REPLACED RT PACK TEMP CONTROLLER PER AMM 21-51-14, OPS CHECKS OK.SDR UIEA2020060101171Starter · inoperativeAPU FAULT ON TAXI-IN. REMOVED AND REPLACED APU BATTERY IAW AMM 24-31-04. APU BATTERY VOLTAGE CHECKS GOOD. ALSO REPLACED APU STARTER IAW AMM 49-41-01 OPS CHECK OK. APU BATTERY OFF PART: PN 018550-000, SN 121356. THIS CLEARS MDDR 129070.SDR UIEA2020060101170Warning System · false activationEICAS MESSAGE LT PACK TEMP. ACCOMPLISHED BITE OF LT PACK TEMP CONTROLLER IAW AMM 21-51-14 AND FAULTED RAM INLET ACT. RESET AND PERFORMED OPERATIONAL CHECK OF LT PACK AND OPERATIONAL CHECK OK IAW 21-51-00.SDR UIEA2020060101174Warning System · false activationRIGHT PACK TEMP EICAS WITH RT PACK INOPERATIVE LIGHT. ACCOMPLISHED BITE OF RT PACK TEMP CONTROLLER AND CONTROLLER FAULTED RESET AND BITE CHECK OK IAW AMM 21-51-14. ACCOMPLISHED RT PACK TEST IAW AMM 21-51-00 OK FOR SERVICE.SDR UIEA2020060201166Ecu · faultyATTEMPTED APU START 2X FAILED, EICAS MESSAGE "APU FAULT". PERFORMED BITE TEST ON APU ECU - FAULTED ECU. REMOVED AND REPLACED APU CONTROL UNIT. OPS CHECK OK PER AMM 49-61-05.SDR UIEA2020052631117Actuator · failedAPU FAULT. REMOVED AND REPLACED APU IGV ACTUATOR PER AMM 49-52-62. LEAK AND OPS CHECK OK. THIS CLEARS DMI 128740.</P>)SDR UIEA2020052601132Start Valve · failedFLT CREW REPORTED LT START VALVE EICAS MSG IN CRUISE FLT. REMOVED AND REPLACED LH ENG START VALVE IAW B767 AMM 80-11-02-004/404. OPS TEST GOOD IAW AMM 71-00-00-995. LEAK CHECK GOOD.SDR UIEA2020052201098Warning System · false activationAFTER ENGINE START DURING TAXI RECEIVED LEFT AC BUS EICAS MESSAGE - QRH COMPLETED(<P>PERFORMED BPCU BITE PROCEDURE IAW B767 FIM 24-20 FT 801 SHEET 1 1, 2 ,12. NO FAULTS NOTED, SYS RESET, FAULT MESSAGE CLEARED.</P>)SDR UIEA2020052101093Ecu · malfunctionedAPU FAULT(<P>PERFORMED APU BITE PROCEDURES IAW B767 FIM 49-11 FT 956. NO FAULTS NOTED. APU START SUCCESSFUL ON THIRD ATTEMPT AFTER RESET ECU.</P>)SDR UIEA2020052001091Connector · dirtyAPU FAULT, NO START(<P>TRANSFERRED TO MDDR 128562 IAW MEL 49-11-01B, CAT 'B'.</P><P>LOG PAGE 1199838: PERFORMED APU BITE PROCEDURES IAW FIM 49-11 FT 958, SH1, BLK1, SH2, BLK2,3, SH3, BLK4,25. NO FAULTS NOTED. REMOVED APU ECU, CLEANED AND INSPECTED CONNECTORS. SDR UIEA2020051401036Oil System · lowAPU FAULT/ OIL Q "ADD"(<P>SERVICED APU OIL, 1 QT AT 2791.1 HRS IAW B767 AMM 12-13-04</P>)SDR UIEA2020051401037Status Message · false activationSTATUS MESSAGE: WRX SYS(<P>PERFORMED B767 FIM 34-43 FT 801, RESET C/B'S F2, F23. PERFORMED AMM 31-41-00-912, MAINT MSG ERASED, PROCEDURE MESSAGE CLEARED.</P>)SDR UIEA2020042200811Fire Detector · inoperativeRIGHT ENGINE FIRE LOOP 2 STATUS MESSAGE. REMOVED AND REPLACED THE RT ENG UPPER AFT FIRE DETECTOR ASSY. OPS TESTED GOOD IAW AMM 26-11-02-024/424.SDR UIEA2020032700555Connector · looseEMERGENCY LIGHTS AT L4 DOOR TURN ON AND OFF IN FLIGHT.(<P>AFTER INSPECTED FOUND LOOSE CONNECTOR, ADJUSTED AND TESTED OK IAW AMM 33-51-02.</P>)SDR UIEA2020031300440Gcu · malfunctionedAPU GENERATOR DROPPED OFF LINE, APU RUNS OK (ELECTRIC INOP), BPCU FAULTS GEN TRIP AND GEN.(<P>DEFERRED APU GENERATOR INOP AS PER MEL 24-00-02B, CAT 'B': MDDR 125698.</P><P>LP <SPAN>1045963: </SPAN><SPAN>REMOVED AND REPLACED APU GENERATOR IAW B767 AMM REF 24-21SDR UIEA2020022620304Oven · smokeAFT GALLEY A114 OVEN SMOKING (SMOKE TRIPPED AFT LAV SMOKE DETECTORS). LP 1068450: AFT GALLEY A118 OVEN HAS ELECTRICAL ODOR WHEN HEATING.(<P>SMOKE CAUSED BY DIRTY OVEN. TRANSFERRED TO MDDR 124962, NEF 25-20-01, GALLEY, ITEM 3, CAT C, DUE 03 MAR 20. C/B PULLED ASDR UIEA2020022600328Shutoff Valve · malfunctionedEICAS MSG "R ENG HPSOV" INTERMITTENT THROUGHOUT FLIGHT.(<P>REMOVED AND REPLACED RH HPSOV IAW B767 AMM 36-11-07-024/424. PERFORMED AIR SUPPLY MODULE BITE PROCEDURE IAW B767 AMM 36-23-00/501. NO FAULTS NOTED. PERFORMED LEAK CHK DURING DRY RUN. NO LEAKS NOTSDR UIEA2020022400321Warning Message · false activationR ENG HPSOV STATUS MSG.(<P>PERFORMED AIR SUPPLY MODULE BITE PROCEDURE IAW B767 FIM 36-20 FT 804 SH3 BLK 1, 2, SH4 BLK 3, NO FAULT SH5 BLK 4, VERIFIED NO FAULT. BLK 5 RESET, SYS OK.<BR /></P>)SDR UIEA2020021760258Warning Message · false activationRIGHT PACK TEMP EICAS MESSAGE. MOVED SWITCH TO STBY PER QRH.(<P>PERFORMED BITE TEST ON #2 PACK PER AMM 21-51-00. NO PROBLEM NOTED. OPS CHECKED GOOD.</P>)SDR UIEA2020021740255Actuator · faulted2 HR 11 MIN INTO FLIGHT AT FL 360, GOT THE EICAS MESSAGE RIGHT PACK TEMP. MOVED RIGHT PACK CONTROL SELECTOR TO STBY AS PER CHECKLIST AND THE INOP LIGHT WENT OUT.(<P ><SPAN>PERFORMED RIGHT PACK TEMP / CONTROLLER BITE AS PER AMM 21-51-14. THE TEST FAULTED RT PSDR UIEA2020021210231Radar · malfunctionedWEATHER RADAR TILT NOT WORKING PROPERLY. PAINTING RED AT ALL ANGLES WITHIN 10 MILES OF AIRCRAFT.(<P>ACCOMPLISHED L/R WEATHER RADAR OPERATIONAL TEST AS PER AMM 34-43-00-715-001-001 AND TILT/GAIN WORKS NORMAL ON BOTH SIDES. OK FOR SERVICE.</P>)SDR UIEA2020021320243Controller · faultedDURING RT PACK TEMP INSP. IN AUTO AFTER COMPLETION OF REPAIRS TO WIRING, FOUND R PACK CONTROLLER WITH INTERNAL FAULTS.(<P>REMOVED AND REPLACED PACK TEMP CONTROLLER AS PER 21-51-14 AND BITE CHECKS OK. ALSO PERFORMED OPS TEST OF BOTH A/C PACKS AS PER AMM 21-51-0SDR UIEA2020021100230Wire · shortedDURING TRANSIT CHECK AT STATION ADW, FOUND C/B C38B (VACUUM BOWER LAV SYSTEM 2) CB POPPED. UPON RESET CIRCUIT SHORTED, FOUND WIRES W0580-154-10, 153-10, 13-24, 9-24, 99-14, 31-20, 95-12, 94-12, 93-12, DAMAGED DUE TO SHORTING AGAINST CLAMP.(<P>PERFORMED OPS CHESDR UIEA2020021100233Circuit Card · not seatedRIGHT PACK TEMP ILLUMINATED IN FLIGHT.(<P>PERFORMED BITE OF RT PACK TEMP CONTROLLER, FAULTED RT RAM AIR INLET ACTUATOR, RE-SEATED RT TEMP CONTROL PC M864. PERFORMED RESET PROCEDURE, FAULT CLEARED IAW AMM 21-51-00-705-001.</P>)SDR UIEA2020021100234Knob · brokenRADAR GAIN CONTROL KNOB BROKEN.(<P>REPAIRED RADAR GAIN CONTROL KNOB. INSTALLED. OPS CHECK NORMAL IAW B767 AMM 34-43-00.</P>)SDR UIEA2020020760200Controller · inoperativeRIGHT PACK TEMP CONTROLLER INOP.(<P>ACCOMPLISHED BITE OF RT PACK TEMP CONTROLLER AND FAULTED (AT RAM AIR INLET ACTUATOR). ACCOMPLISHED RESET PROCEDURE AND FAULT ERASED AS PER AMM 21-51-00-705-001. ALSO CLEANED CONNECTOR AS A PRECAUTIONARY. OK FOR SERVICE PER ASDR UIEA2020020700208Radar · malfunctionedINTERMITTENT RADAR SPIKING.(<P><SPAN>RESET C/B'S ON BOTH L/R RADAR R/T'S AND WAVE BRIDE S/W UNIT AND PERFORMED L/R RADAR TEST AS PER AMM 34-43-00 AND TESTED OK FOR SERVICE.</SPAN><BR /></P>)SDR UIEA2020020520165Warning Message · false activation"RH PACK TEMP" EICAS MESSAGE.(<P>PERFORMED RIGHT PACK SYSTEM OPS CHECK IAW AMM 21-51-14. OPS CHECK GOOD AT THIS TIME.</P>)SDR UIEA2020020320166Controller · malfunctionedRIGHT PACK AUTO MODE INOP.(<P>RH PACK AUTO MODE INOP TRANSFERRED TO MDDR 124201, IAW DDG 21-51-03-01, CAT 'C', DUE DATE 12FEB20.</P><P>LP 1225953: REMOVED AND REPLACED RT PACK TEMP CONTROL ASSY IAW AMM 21-51-14. OPS CHECKS NORMAL, BITE TEST PASSED IAW AMM 21-5SDR UIEA2020020410164Warning Message · false activationRH PACK TEMP MESSAGE DURING CRZ. SWITCHED PACK TO "N" POSITION, AND MSG CLEARED.(<P>ACCOMPLISHED RT PACK TEMP CONTROLLER BITE AS PER AMM 21-51-14 AND RT PACK RESET AND OPS CHECKS GOOD.</P>)SDR UIEA2020020300175Lamp · inoperativeCARGO SMOKE DET 2 (FWD) STATUS MESSAGE.(<P>RELAMPED FWD CARGO SMOKE DETECTOR #2 AND PERFORMED RESET AND OPERATIONAL CHECK AS PER AMM 26-16-01. OK FOR SERVICE.</P>)SDR UIEA2020011700088Iru · out of alignmentWEATHER SYSTEM STATUS MESSAGE. ALIGNED 3 IRU'S, WHILE TESTING BOTH LEFT AND RIGHT WEATHER RADAR, MESSAGE EXTINGUISHED. OPS CHECK OK PER AMM 34-43-00.SDR UIEA2020010900039Ignition Sys · malfunctionedNO LIGHT OFF RIGHT ENGINE.(<P>RESET C/B FOR RIGHT ENGINE IGNITION AND PERFORMED RIGHT ENGINE IDLE RUN UP IAW AMM 71-00-00. OPS CHECK NORMAL.</P>)SDR UIEA2020010800035Gcu · malfunctionedREPEATS OF RT GENERATOR DISCONNECT ON RT ENGINE START.(<P>REMOVED AND REPLACED RIGHT GENERATOR CONTROL UNIT IAW B767 AMM 24-22-02. OPS CHECK OK.</P>)SDR UIEA2019123086154Gcu · failedNR 2 GENERATOR DRIVE LIGHT INOPERATIVE. REMOVED AND REPLACED THE NR 2 GCU IAW MM 24-22-02. RUN OK, LIGHT OK.SDR UIEA2019121806098Sensor · failedDURING RH PRSOV REPLACEMENT FOUND FATS 1X SOLENOID WIRE DAMAGED. REMOVED AND REPLACED THE RT FAN AIR MODULATOR VALVE TEMP SENSOR IAW AMM 36-11-17-001. LEAK CHECKED GOOD, BITE CHECKED GOOD, FAN AIR VALVE UNLOCKED FROM INTERMEDIATE POSITION.SDR UIEA2019120986025Switch · failedWHEN STARTING RIGHT ENGINE, SPAR VALVE LIGHT DIDN'T COME ON. SPAR VALVE LIGHT ILLUMINATED NORMALLY ON SECOND ENGINE START. REMOVED AND REPLACED THE RT ENGINE SPAR VALVE LIGHT ASSEMBLY IAW AMM CH 33-16-02. INDICATION NORMAL DURING TEST PER AMM CH 33-16-02. THI
Back to Boeing 767-3S1