Boeing 767-3S1
Service difficulty reports · 974
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673S1' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673S1' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019120976016Controller · failedRIGHT ENG PRV EICAS MESSAGE ON TAKEOFF ROLL, PERFORMED QRH PROCEDURE AIRBORNE. REMOVED AND REPLACED PRESSURE REGULATOR CONTROLLER ASSY PER AMM 36-11-14 AND UNLOCKED. PRSOV LEAK CHK OK.SDR UIEA2019120976015Valve · failedSTATUS MESSAGE: R ENG PRV.(<P>REMOVED AND REPLACED RT ENG PRV AS PER AMM 36-11-18. LEAK CHECK OF COUPLINGS, LINES CHECK OK, AND ACCOMPLISHED PNEUMATIC CONTROL BITE AS PER AMM 36-23-00 AND NO FAULTS NOTED. OK FOR SERVICE. IDLE ENG RUN TEST 4 PER AMM 71-00-00 OKSDR UIEA2019120606008Status Message · false activationSTATUS MESSAGE FOR RT ENG PRV. ACCOMPLISHED EICAS ERASE PROCEDURE AND MESSAGE ERASED. ACCOMPLISHED AIR SUPPLY BITE IAW FIM 36-20 TREE 804 AND MESSAGE AT PRV FAULTED AND ERASED. NO HARD FAULT. NO BLEED FLUCTUATION REPORTED. SENSE LINES OK. NO LEAKS IAW AMM 36SDR UIEA2019120506001Sign · malfunctionedCOCKPIT "EXIT" EMERGENCY LIGHT FLASHING DURING TAKEOFF ROLL AND LANDING.(<P>RE-SECURED COCKPIT EXIT EMERGENCY LIGHT ASSEMBLY AS PER AMM 33-51-01 AND OPS CHECK OK.</P>)SDR UIEA2019112765959Starter · failedLEFT ENGINE STARTER MESSAGE ON START, NO N2 ROTATION.(<P>REMOVED AND REPLACED LEFT ENGINE STARTER IAW AMM 80-11-01/401, OPS TEST GOOD.</P>)SDR UIEA2019111985923Warning Message · false activationSTATUS MESSAGE "CABIN ALT AUTO 2".(<P>PERFORMED CABIN PRESSURE CONTROLLER BITE IAW B767 AMM 21-31-00, "AC MOTOR" FAULT. CONTROLLER RESET, STATUS MESSAGE CLEARED AND CONTROLLER BITE TEST GOOD. <BR /></P>)SDR UIEA2019111105881Status Message · false activationCABIN ALT 2 STATUS.(<P>ACCOMPLISHED FIM 21-31 FAULT TREE 803 AND AC MOTOR FAULTED. VERIFIED OK FOR SERVICE, FAULT RESET, AND NO OTHER FAULTS NOTED AT THIS TIME. OKAY FOR SERVICE, MESSAGE ERASED.</P>)SDR UIEA2019110505858Transceiver · malfunctionedWXR FAIL DISPLAYED ON ND, SWITCHED SYS FROM L TO R, ND DISPLAY STATUS MSG "WXR SYS" REMAINED AT SHUTDOWN.(<P>RE-RACKED L WX RADAR T/R. PERFORMED LEFT AND RIGHT WX RADAR OPS TEST PER AMM 34-43-00, BOTH SYSTEMS OK FOR SERVICE.<BR /></P>)SDR UIEA2019110105834Warning System · false activationRIGHT WEATHER RADAR SYSTEM FAIL. (<P>PERFORMED OPERATIONAL TEST OF BOTH LEFT AND RIGHT WEATHER RADAR SYSTEM IAW B767 AMM 34-43-00, OPS CHECK GOOD. NO EICAS MESSAGE SHOWN, ALL SYSTEMS OK.</P>)SDR UIEA2019103195809O-Ring · leakingEVIDENCE OF OIL LEAK COMING FROM #2 IDG.(<P>FOUND IDG NIPPLE AND O-RING LEAKING. REMOVED AND REPLACED NIPPLE AND O-RING. PERFORMED FUNCTIONAL CHECK OF IDG, OPS CHECK OK, REF AMM 24-11-01 AND 24-11-00. SERVICED IDG AS PER AMM 12-13-03. </P>)SDR UIEA2019102805803Fire Detector · false activation"R ENG FIRE LP 2" STATUS MSG. (<P>TRANSFERRED TO MDDR #119676 IAW MEL 26-11-01-01, CAT 'C', DUE DATE: 04-NOV-19. AIRCRAFT DOWNGRADED TO 120. PLACARDS INSTALLED AND MCC NOTIFIED. </P><P>REF LOG PAGE 1101574- ITEM 10: REMOVED AND REPLACED #2 ENGINE HOT SECTION BSDR UIEA2019102435784Status Message · false activationR ENGINE FIRE LP2 STATUS MSG(<P>PERFORMED OPS CHECK OF RT ENG FIRE LOOP, OPS CHECKED GOOD AT THIS TIME PER ATLAS AMM 767 26-11-01</P>)SDR UIEA2019102205780Engine · vibrationINFO ONLY: RIGHT ENGINE VIBRATION READS 2.9 ON INITIAL CLIMB TO CRUISE POWER SETTING. NO OTHER ABNORMAL INDICATIONS NOTED. (<P>NOTED BY MAINTENANCE, WITHIN LIMITS IAW AMM 71-00-00-862-020. </P>)SDR UIEA2019101425705Oxygen Mask · unwanted deployOXYGEN MASKS AT SEAT 29 AC FELL DOWN. INSPECTED AND REPACKED O2 MASKS AT SEAT 29AC AS PER AMM 35-21-10, AND OK FOR SERVICE.</P>)SDR UIEA2019100985677Plenum · not reportedL/H PACK PLENUM REQUIRES REPLACEMENT. L/H PACK PLENUM REMOVED AND REPLACED IAW B767 AMM 21-51-02. LEAK CHECK OK AT THIS TIME.SDR UIEA2019100325628Relay · malfunctionedLEFT PACK TEMP EICAS MESSAGE. REMOVED AND REPLACED L/H RAM AIR EXHAUST DOOR ACTUATOR IAW AMM 21-53-02, NO HELP. FURTHER T/S REQ. REMOVED AND REPLACED R27, LT PACK AUTO/MANS RELAY IAW SWPM 20-81-18. OPS CHECKED GOOD.SDR UIEA2019100205626Warning Light · false activationLEFT PACK TEMP EICAS DURING FLIGHT. ACCOMPLISHED FIM 21-51 FT 803 AND FAULTED LEFT RAM AIR EXHAUST ACTUATOR. RESET CONTROLLER AND ACCOMPLISHED LT PACK COOLING TEST, OPS CHECKED OK IAW AMM 21-51-00.SDR UIEA2019100215621Fire Warning · false activationRIGHT ENGINE FIRE LOOP 2 STATUS MESSAGE AFTER BLOCK IN. PERFORMED FIM TASK 26-11 FT 804. ALL LOOP 2 RESISTANCES FOUND WITHIN LIMITS (4.5K OHMS). PERFORMED MEGGER TEST, FOUND ALL RESISTANCES TO BE 110 MEGA OHMS. PERFORMED OPS TEST OF SYSTEM PER AMM 26-11-00 SDR UIEA2019092805596Controller · malfunctioned"LEFT PACK TEMP" EICAS MESSAGE. PERFORMED ABNORMAL QRH AND LEFT PACK TO STBY.(<P>PERFORMED BITE ON LH PACK CONTROLLER, FAULTED "INLET TEMP SENSOR". RESET CONTROLLER AND PERFORMED LH PACK OPS TEST, OPS CHECK GOOD IAW B767 AMM 21-51-00.</P>)SDR UIEA2019092605584Controller · malfunctionedLT PACK TEMP EICAS MSG. QRH DIRECTED TO SELECT STBY N.(<P>ACCOMPLISHED BITE OF LH PACK CONTROLLER, FAULTED RAM AIR OUTLET ACTUATOR. RESET CONTROLLER. ACCOMPLISHED LH PACK COOLING TEST, OPS CK GOOD IAW AMM 21-51-00.</P>)SDR UIEA2019091205490Lever · brokenITEM 1 - CA'S OXYGEN TEST SLIDE LEVER IS BROKEN. ITEM 2 - REF ITEM #1, SECOND OBSERVERS O2 BOX SLIDE TEST LEVER BROKEN. FOUND TEST SLIDE LEVER BROKEN, NEEDS REPLACEMENT. SWAPPED O2 BOX FROM SECOND OBSERVERS SEAT AND INSTALLED IN CAPTAIN'S O2 POSITION PER AMM 3SDR UIEA2019091205491Valve · malfunctionedSPAR VALVE, RIGHT ENGINE, FAILED OPERATIONAL CHECK. PERFORMED SPAR VALVE OPS CHECK, RT ENG, IAW AMM 28-22-11-714-014. OPS TEST GOOD.SDR UIEA2019091305492Controller · malfunctionedLT PACK TEMP EICAS, FOLLOWED QRH. ACCOMPLISHED BITE OF LEFT PACK CONTROLLER AND FAULTED RAM AIR OUTLET ACTUATOR. RESET CONTROLLER AND ACCOMPLISHED LT PACK COOLING TEST. OPS CHECK OK AS PER AMM 21-51-06.SDR UIEA2019090305441Relief Valve · leakingEVIDENCE OF OIL LEAK, RIGHT IDG PRESSURE RELIEF VALVE/TUBE. REMOVED AND REPLACED RELIEF VALVE AND LINES IAW AMM 24-11-18. OPS CHECK GOOD IAW AMM 20-10-09.SDR UIEA2019083105414Acm · noisyRT PACK ACM MAKES LOUD NOISE WHEN OPERATED. DEFERRED RT PACK INOP AS PER MEL 21-51-01-01 CAT C MDDR# 117144. ASSIGNED (M) ACTIONS COMPLIED WITH PACK FLOW CNTR S/O VALVE MANUALLY CLOSED OFF. SL @ 17:00Z. LP 1073633 - M15; REMOVED AND REPLACED RIGHT PACK ACM REFSDR UIEA2019082905320Warning Message · false activationLEFT PACK TEMP EICAS MESSAGE AFTER SELECTING PACKS TO AUTO AFTER ENGINE START. ACCOMPLISHED BITE OF LH PACK CONTROLLER AND FAULTED RAM AIR OUTLET ACTUATOR. RESET CONTROLLER AND ACCOMPLISHED LH PACK COOLING TEST. OPS OK, NO FAULTS NOTED. OK FOR SERVICE AS PER SDR UIEA2019082805316Line · looseON WALK AROUND FOUND RT IDG LEAKING. FOUND RT IDG OIL RETURN LINE LOOSE. TIGHTENED AS PER AMM 24-11-01 AND SERVICED RT IDG PER AMM 12-13-03. LEAK CHECKED RT IDG PER AMM 71-00-00/501 CONFIG 3 AND OK FOR SERVICE, NO LEAKS NOTED.</P>)SDR UIEA2019081645155Controller · malfunctionedPRV STATUS MESSAGE. REMOVED AND REPLACED THE PRESSURE REGULATING CONTROLLER IAW AMM 36-11-19. PERFORMED RUN UP IAW AMM 71-00-00. OPS CHECK NORMAL, NO FAULTS NOTED.SDR UIEA2019081205001Fire Detector · warning messageDURING PRE-FLIGHT, STATUS MESSAGE RT ENGINE FIRE LOOP 2. REMOVED AND REPLACED LWR FWD FIRE DETECTOR ASSY IAW AMM 26-11-02. STATUS MESSAGE REMOVED, OPS CHECK NORMAL.SDR UIEA2019081325016Warning Message · false indicationR ENG PRV STATUS MESSAGE.(<P>ACCOMPLISHED BITE OF AIR SUPPLY CONTROL SYSTEM AND FAULTED RT PRV. RESET, AND FAULT ERASED ON CONTROLLER STATUS MESSAGE. ACCOMPLISHED RT ENG IDLE RUN-UP IAW AMM 71-00-00 AND RT ENG RUN-UP OK, NO FAULTS NOTED.SDR UIEA2019081205002Overheat Loop · malfunctionedDURING PRE-FLIGHT, FOUND STATUS MESSAGE RT ENGINE OVER HEAT LOOP 1. REMOVED AND REPLACED TS 684 UPPER FWD LOOP IAW AMM 26-11-02. OPS CHECK NORMAL.</P>)SDR UIEA2019081405168Battery · inoperativeON WALK AROUND FOUND O/H EMERG EXIT AISLE LIGHTS INOP ROW 18H-31H(<P>REMOVED AND REPLACED BATTERY EMERGENCY POWER SUPPLY FOR EXIT AISLE LIGHT AT ROW 18H-31H. OPS CHK NML IAW B767 AMM 33-51-00.<BR /></P>)SDR UIEA2019080104905Warning Message · false activationEICAS MSG "R PACK TEMP. PERFORMED FIM B767 21-51 FT 803, PACK TEMP CONTROL BITE FAULTED RAM INLET ACTR, RESET CONTROLLER, PERFORMED BITE TEST, NO FAULTS NOTED. RT PACK OPS CHECK GOOD IAW AMM 21-51-00.SDR UIEA2019072504849Controller · malfunctionedINTERMITTENT DISPLAY OF R PACK TEMP EICAS IN CRUISE AND APCH/DESCENT. NO ACTIVATION OF MASTER CAUTION. (<P>PERFORMED FIM 21-51 FT 803, PACK TEMP CONT BITE FAULTED "RAM INLET ACTR". RESET CONTROLLER, PERFORMED BITE, FAULT CLEARED. RT PACK OPS CK GOOD IAW AMM 21SDR UIEA2019071704768Circuit Card · defectiveL PACK TEMP WHILE IN AUTO. QRH LED TO POSITION IN STBY MODE, LT PACK TEMP CAUTION EXTINGUISHED. (<P>ITEM TRANSFERRED TO MEL 21-51-03-01, CAT C, DUE DATE 26-JUL-19, MDDR 114876. </P><P>LP 1081077 - M3: REMOVED AND REPLACSDR UIEA2019071104736Warning System · false activationL PACK TEMP EICAS MSG IN AUTO POSITION.(<P>PERFORMED FIM 21-51 FT 803, PACK TEMP CONT BITE, NO FAULTS NOTED, RESET OK. OPS CK LT PACK ON GROUND IAW AMM 21-51-00. OPS CK GOOD.</P>)SDR UIEA2019071704778Warning System · false activationAPPROXIMATELY 6:30 INTO FLIGHT AT FL360, RT PACK TEMP EICAS MSG. (<P>ACCOMPLISHED FIM 21-51 TREE 803, (PACK TEMP CNTRAL BITE) FAULTED TEMP CONTROL VALVE. RESET OK, FAULT ERASED. OPS CK OF RT PACK ON GROUND OK PER AMM 21-51-00.<BR /></P>)SDR UIEA2019070904716Warning System · false activationLEFT PACK TEMP EICAS MSG C/W QRH (<P>ACCOMPLISHED FIM 21-51 FT 803 PACK TEMP CONTROL BITE AND FAULTED LEFT PACK RAM OUTLET ACT RESET FAULT AND CLEARED MESSAGE OK FOR SERVICES </P>)SDR UIEA2019070404674Unknown · malfunctionedRIGHT ENG FAILED SPAR VALVE OPERATIONAL CHECK. (<P>ACCOMPLISHED RT ENG SPAR VALVE ACTUATOR TEST AS PER AMM 28-22-11 AND OPS CHECK OK FOR SERVICE. ALSO RAN UP RT ENGINE TEST # 4, GROUND IDLE TEST PER AMM 71-00-00 AND RT SPAR VALVE LT OPS OK.</P>)SDR UIEA2019062904614Actuator · faultyDUE TO RIGHT RECIRCULATING PERFORMANCE REQUEST CHANGE OF RIGHT ACTUATOR ASSY DOOR (<P>REMOVED AND REPLACED RIGHT RAM AIR EXHAUST DOOR ACTUATOR IAW AMM 21-53-04. OPS CHECK NORMAL. </P>)SDR UIEA2019062654572Warning Message · false activationAMBER CAS, L PACK TEMP. QRH COMPLIED WITH, MSG OUT. PERFORMED B767 FIM 21-51 FT 812, PACK CONTROL UNIT BITE. NO FAULTS NOTED, PACK CONTROL UNIT RESET. LEFT PACK OPS NORMAL.SDR UIEA2019062604595Warning Light · false activationAMBER CAS - L PACK TEMP. QRH COMPLIED WITH. MSG OUT.(<P>PERFORMED B767 FIM 21-51 FT 812, PACK CONTROL UNIT BITE, NO FAULTS NOTED. PACK CONTROL UNIT RESET, LH PACK OPS NORMAL.</P>)SDR UIEA201906214536Module · malfunctionedAPU REVERSE FLOW FAULT. REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-53-08. OPS CHECK GOOD.</P>)SDR UIEA2019061404490Valve · malfunctionedRETURNED TO BLOCKS AFTER APU SHUTDOWN. REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW AMM 49-53-01 OPS CHECK PER AMM 49-11-01 GOOD.SDR UIEA2019060704428Radar · failedRIGHT WX RADAR FAIL.(<P>ACCOMPLISHED FIM 34-43 TASK 801 AND WX RADAR FAULT ERASED PER AMM 31-41-00-912-009 AND ACCOMPLISHED RT WX RADAR TEST PER AMM 34-43-00. A/C OK FOR SERVICE.</P>)SDR UIEA2019060704410Window · malfunctionedL2 WINDOW, SWAPPED SENSOR WIRING AT TB 324 PER FIM 30-41 FT 804. (REF NON-MEL 110386). (<P>R/R L2 WINDOW PANE IAW CMM 56-11-12. INSTALLED L2 WINDOW IAW AMM 56-11-02. RECONNECTED WINDOW SENSOR AT TB 234 IAW AMM 30-41-00. BACK TO PRIMARY SENSOR, OPS NORMAL. </P>SDR UIEA2019060704412Ecu · malfunctionedAPU AUTO SHUTDOWN. REMOVED AND REPLACED APU SURGE BLEED VALVE IAW AMM 49-53-01, NO HELP, APU SURGES INTERMITTENTLY. PERFORMED FIM 49-11 FT 958, FOUND ECU FAULTING DELTA SENSOR FLOW SENSING MODULE AND IGV ACTUATOR. REMOVED AND REPLACED APU ECU. OPERATIONALSDR UIEA2019060704415Lamp · inoperativeR4 EXTERIOR EMERGENCY LIGHT INOP. RELAMPED R4 EXTERIOR EMERGENCY LIGHT. OPS CHECK NORMAL IAW AMM 33-51-01.</P>)SDR UIEA2019060704416Light · unsecureMID LAV EMERGENCY LIGHT STRIP DISBONDED FROM FLOOR.(<P>RESECURED MID LAV EMERGENCY LIGHT STRIP IAW AMM 33-51-00.</P>)SDR UIEA2019060314362Controller · malfunctionedLEFT PACK TEMP EICAS MESSAGE THROUGH 10,000 FT. ACCOMPLISHED FIM 21-51 TREE 803 AND PACK TEMP CONTROLLER BITE FAULTED. RAM AIR EXHAUST ACTUATOR; RESET CONTROLLER AND RE-BIT. OPS CHECKS OK.
Back to Boeing 767-3S1