Boeing 767-424ER
Service difficulty reports · 1,159
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767424ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767424ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017070802111Oven · malfunctionedOVEN 107 WAS HOT EVEN THOUGH NOT IN USE ELECTRICAL ODOR COMING FROM AREA. PULLED THE CIRCUIT BREAKER AND RESET AND PERFORMED OPS CHECK NO ELECTRICAL ODOR AND OPS NORMAL.SDR CALA2017070702109Line · leakingLEFT ENGINE OIL QUANTITY LOW. AIRCRAFT DIVERTED TO KSFO WHEN READING 5 QTS. DURING ENGINE MOTORING, FOUND OIL TUBING LEAKING AT LOWER CASE. BORESCOPE FOUND EXCESSIVE OIL LEAKAGE UPPER QUADRANT WITH DAMAGE TO OIL LINE. ENGINE CHANGE UNDER WAY.SDR CALA2017070702108Circuit Card · unserviceableENGINE FUEL FEED SYSTEM CTR L (R) FUEL PUMP EICAS MSG SHOWS AND LEFT (RIGHT) C PUMPS PRESS LIGHT IS ON 02 RIGHT FUEL CENTER PUMP LIGHT CAME ON W/ASSOC EICAS WITH 7.0 IN CENTER TANK DUE TO AIR RETURN PER CREW DEBRIEF, BOTH CTR RT FUEL PUMP OFF AND RT BLEED OFF SDR CALA2017063002006Chiller · odorAFT GALLEY CHILLERS OVERHEATED. BURNING SMELL NOTED. R&R RIGHT AFT GALLEY CHILLER IAW AMM 25-33-02-01. OPS CHECK GOOD . NO DEFECTS NOTED.SDR CALA2017062601991Altimeter · out of limitsSTBY ALTIMETER STICKY IN CLIMB AND DESCENT JUMPS 500 FEET AT A TIME REMOVED AND REPLACED STBY ALTIMETER IAW AMM 34-13-06.SDR CALA2017062501976Unknown · odorINBOUND CREW REPORTED ELECTRICAL ODOR IN LAVATORY F IN AREA OF CEILING DOME LIGHT, GASPER AIR OUTLET, NO ELECTRICAL ODOR FOUND. OK TO CONTINUE.SDR CALA2017060901770Socket · dirtyEXT EMER SLIDE LIGHT DOOR R3 INOP, RELAMP NO HELP. CLEANED SOCKET AND RELAMPED R3 DOOR SLIDE LIGHT IAW AMM 33-51-06 . OPS CHK GOOD.SDR CALA2017060901769Socket · dirtyEXT EMER SLIDE LIGHT DOOR L3 INOP, RELAMP NO HELP. CLEANED SOCKET AND RELAMPED L3 DOOR SLIDE LIGHT IAW AMM 33-51-06 . OPS CHK GOOD.SDR CALA2017060501699Lens · brokenDURING WALKAROUND FOUND EMERGENCY EXIT LIGHT LENS AT LEFT EMERGENCY EXIT BROKEN. REPLACED EMERGENCY EXIT LIGHT LENS IAW AMM 33-51-06. OK TO CONTINUE.SDR CALA2017060201663Connector · damagedLOST NR 1 ENGINE OIL PRESSURE INDICATION, DIGITAL READ OUT AND POINTER. PERFORMED TROUBLESHOOTING IAW SSM 79-00-01, FOUND NO VOLTAGE IN CONNECTOR D10982. FURTHER TROUBLESHOOTING CARRIED OUT IAW WDM 79-32-11. FOUND PIN NOT CORRECTLY SET IN CONNECTOR D4198P.SDR CALA2017052601589Power Supply · faultedEMERGENCY LIGHTS DIM AT SEATS 40, 41, 42, 43, & 44DF. REPLACED THE POWER SUPPLY. OPS GOOD.SDR CALA2017052601588Connector · dirtyEMERGENCY LIGHTS DIM AT SEATS 33, 34, 35DF. DISCONNECTED, CLEANED, AND RECONNECTED THE CONNECTOR. OPS GOOD.SDR CALA2017051901459Shutoff Valve · faultyFWD EQUIP OVHT EICAS STBY NO HELP AFTER 5 MIN THEN OVRD AND OVHT LIGHT OUT. EMERGENCY DECLARED. ACP TASK 21-58-00-815-860-002 BLOCK 1,2,AND 22. REPLACED SHUTOFF VLV (V178) REF AMM 21-58-13 AND RELAY K369 IN P36 PLN REF WDM 21-58-12 OP CHK GOOD LEAK CHK GOOD.SDR CALA2017051501449Battery · faultyEMERGENCY FLASHLIGHT (MISSING, NEEDS NEW BATTERY, ETC.) COCKPIT FLASHLIGHT NEEDS A NEW BATTERY. REPLACED FLASHLIGHT AND BATTERY OPS CHECK NORMAL.SDR CALA2017051201391Light · shortedAFTER TESTING EMER LIGHTS BETWEEN 31-34, NO LIGHTS SEE PREVIOUS WU CONFIRMED. FOUND SHORTED EMERGENCY LIGHT SEAT PATH LIGHT ASSY ON SEAT 31D. R&R IAW AMM 33-51-10-962-104. VISUAL OPS CHECK OF SYSTEM OK, TEST OF SYSTEM OK, A/C OK TO CONTINUE.SDR CALA2017051201390Battery Pack · not seatedSEAT MOUNTED EMER. LIGHTS PATH FROM ROW 31 TO 34 NOT WORKING. PERFORMED BATTERY PACK REMOVED AND REINSTALLED AS AMM 33-51-07/201, TEST OK.SDR CALA2017051201389Lens · missingMID GALLEY EMERGENCY LIGHT LENS COVER IS MISSING. REATTACHED MID GALLEY EXIT LIGHT LENS.SDR CALA2017050101205Control Module · faultyOVEN 607 SMOKE WHILE USING. COOKS TOO HOT. REPLACED THE OVEN 607 CONTROL MODULE ASSY.SDR CALA2017050101204Heater · odorFLIGHT CREW REPORTED HEATER AT THE L1 DOOR HAD A BURNED ODOR, SHUT OFF AND ODOR WENT AWAY. IT HAS PREVIOUS HISTORY. REPLACED THE HEATER IAW AMM 21-45-23-404-002, OPS CHECKED GOOD.SDR CALA2017042901193Oven · odorOVEN 110 PRODUCING AN ELECTRICAL ODOR WHEN STARTED. REMOVED AND REPLACED THE OVEN IAW AMM 25-34-00, OPS CHECKED GOOD.SDR CALA2017042801176Power Supply · inoperativeEMERGENCY LIGHT OUT AT ROWS 42,43,44 DEF. R&R POWER SUPPLY AND BATTERY PACK FOR SEATS 42,43,44 DEF IAW AMM 33-51-07-022-005-001 AND AMM 33-51-07-402-018-001. OPS CHK GOOD.SDR CALA2017042301120Flashlight · inoperative2L FWD FACING FLASHLIGHT NOT CHARGING. REPLACED EMERG FLASHLIGHT AT 2L.SDR CALA2017042201108Socket · looseSEAT 22F EMERGENCY LIGHT ON SEAT IS INOP RESEAT SOCKET AT ROW 22 F. EMERGENCY LIGHT OPS CK GOODSDR CALA2017042201110Bulkhead · corrodedCORROSION FOUND ON PRESSURE DECK CLOSURE PANEL BETWEEN STA 955-9 66 AND LBL 85.9-97.42. CORROSION WAS FOUND BEYOND SRM LIMITS. REPAIR WAS ACCOMPLISHED IAW ECRA 5310-07124. REPEAT INSPECTION REQUIRED IAW ECRA 5310-07 124 PART 1 STEP 2.SDR CALA2017042101094Battery Pack · dischargedOVERHEAD EMERGENCY LIGHTS ROW 4R,5R,7R, AND 8R INOP. REMOVED AND REPLACED BATTERY PACK AT M6756 PER AMM 33-51-07, ALL OPS NORMAL AT AFFECTED ROWS.SDR CALA2017042101093Fuse · inoperativeEMERGENCY LIGHT AT ROW 2LK INOP. REMOVED AND REPLACED POWER SUPPLY M730 FUSE AT PIN 15 IAW AMM 33-51-07-962-024-001. PERFORMED OPS CHECK OF EMERGENCY LIGHT AT 2LK IAW AMM 33-51-00. OPS CHK GOOD.SDR CALA2017041501016Floorbeam · corrodedSTA 303, LBL 24-53 FLOORBEAM FOUND CORROSION. CABIN STA 303, LBL 24-53 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201.SDR CALA2017041400983Unknown · odor1R DOOR HAD BURNING PLASTIC SMELL AFTER TAKEOFF BUT THEN DISSIPATED. CREW REPORT SMELL COMING MORE LIKELY FROM GALLEY AND DISAPPEAR ITSELF AREA INSPECTED IAW AMM 05-51-58-200-801C1. NIL FINDING.SDR CALA2017041400987Sign · dimFLIGHT DECK DOOR OVERHEAD PORTABLE EMERGENCY EXIT SIGN FOUND DIM. FLIGHT DECK DOOR OVERHEAD PORTABLE EMERGENCY EXIT SIGN ASSY REPLACED AND TEST CARRIED OUT NORMAL IAW AMM 33-51-01.SDR CALA2017040400815Connector · looseFOUND EMERGENCY ESCAPE PATH LIGHTS IN ROW 26D, 26F, 27D, 27F INOP . FOUND CONNECTOR UNDER ROW 25 LOOSE. RESECURED AND OPS CHECK GOOD OF EMERGENCY PATH LIGHTS IN ROW 26 AND 27 DEFSDR CALA2017033100767Web · crackedNR 2 PYLON MID SPAR IDG FEED CABLE THROUGH CUTOUT SKIN FOUND CRACKED. CUTOUT THE CRACKED AREA AND REPAIRED IAW SRM 54-55-01, REPAIR 2, FIG 202, DETAIL I.SDR CALA2017033100765Web · crackedNR 1 PYLON MID SPAR IDG FEEDER CABLE THROUGH CUTOUT SKIN FOUND CRACKED AT NAC STA 222.25 FORWARD MID SPAR WEB CRACKEDREPAIRED AS PER SRM 54-55-01, REPAIR 2, FIG 203, DETAIL I.SDR CALA2017080402462Warning System · false activationLE SLAT DISAGREE ON FINAL APPROACH T/S AS PER 27-81-FAULT TREE 808.VISUALLY INSPECTED, AND OPERATE D FLAPS ELECTRICALLY AND PNEUMATICALLY. PERFORMED FSEU BITE REF AMM27-51-00-815-809. AND NO FAULTS WERE PRESENT OR NOTED AT THIS TIME. VISUALLY INSPECTED AND OPESDR CALA2017031300588Module · faultyAFTER T/O GOT ALT DISAGREE EICAS. F/O WAS 3 TO 500 FT BELOW CAP T SIDE AND FLUCTUATING. EMERGENCY DECLARED. REMOVED AND REPLACED RT ADM PER 34-26-03-401. GRND CKS OK.SDR CALA2017031200581Floorbeam · corrodedCABIN - STA 325 LBL 35-57 FLOORBEAM FOUND CORRODED. CORROSION REMOVED AS PER SRM 51-10-02, CORROSION REMOVED AREA MEASURED DEPTH 0.035" (ORG THK: 0.100") X WIDTH 2" X LENGTH 3" OUT OF SRM 53-00 -51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT. CORRODED FLOORBEAM UPP CHORDSDR CALA2017022400476Light · inoperativeBULB BURNED OUT ON OVERHEAD PANEL-EMERG EXIT UNARMED LT. RELAMPED CKS OK.SDR CALA2017021700380Bulb · inoperativeR3 DOOR SLIDE EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB IAW AMM 33-51-06. OPS CHECHED GOOD.SDR CALA2017021700370Battery Pack · no testEMERGENCY LIGHT FAILED OPS TEST. TROUBLESHOOTING FOUND BATTERY PACK EQ M1208 CANNOT CHARGE. THE BATTERY PACK WAS REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-07.SDR CALA2017021700369Battery Pack · no testEMERGENCY LIGHT FAILED OPS TEST, TROUBLESHOOTING FOUND BATTERY PACK EQ M1208 CANNOT CHARGE. BATTERY PACK REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-07.SDR CALA2017021700368Battery Pack · no testEMERGENCY LIGHT OP TEST TROUBLESHOOTING FOUND BATTERY PACK EQ M1210 CANNOT CHARGE. THE BATTERY PACK WAS REPLACED AND OP TEST RESULT NORMAL AS PER AMM 33-51-07.SDR CALA2017021700367Light · no testSEATS 25DEF AND 40DEF EMERGENCY LIGHT INOPERATIVE. THE EMERGENCY LIGHT WAS REPLACED AND INSTALLATION TEST NORMAL IAW AMM 33-51-10.SDR CALA2017021700395Skin · dentedFOUND A DENT AT BS 360 BETWEEN STRINGERS 20 AND 21L. REPAIRED IAW ECRA 5330-0591, REV- PART 1.SDR CALA2017013000205Battery · dischargedDOOR 3R EMER FLASHLIGHT INOP. REPLACED BATT AND SEAL. OPS CKS GOODSDR CALA2017012000144Pump · faultyR N1 3 PCT LESS THAN L N1 AT TAKEOFF PWR. ALL OTHER INDICATIONS IN NORMAL RANGE. OK INFLT PER INBOUND CREW, SHOULD READ LEFT ENGINE WAS 3% LOWER N1 THAN RIGHT ENGINE. REPLACED NR 1 ENG FUEL PUMP DUE TO FAILED PRESSURE TEST PER AMM 73-11-01-705-001-H00. PER AMMSDR CALA2017011600110Unknown · malfunctionedLEFT ENGINE INDICATION WOULD NOT REACH COMMANDED POWER ON THE TAKEOFF ROLL CARRIED OUT CHECK AND SECURITY OFF EEC CONNECTIONS NO DEFECTS NOTED. REMOVED N1FAN SPEED SENSOR REF AMM 77-12-01-004-007-H00 CARRIED OUT INSPECTION OF INTEGRITY NO DEFECTS NOTED. CARRIESDR CALA2017011600120Connector · looseAS PER CREW, ROW 1AB EMERGENCY LIGHT INOP. PERFORMED RESERVE OF ELECTRICAL CONNECTIONS ON AISLE LIGHT ASSY L3300 REF AMM 33-51-05. PERFORMED EMERGENCY LIGHTS OP CHECK AS PER REF AMM 33-51-00. FOUND NORMAL.SDR CALA2017011600119Light · inoperativeR2/L1 EXTERIOR EMERGENCY LIGHTS INOP. RELAMPED L1 DOOR EMERGENCY EXT LIGHT. REPLACED FUSE IN R2 DOOR EMERGENCY LIGHT PWR SUPPLY SYSTEM. OPS CHECKED NORMAL REF AMM 33-51-06.SDR CALA2017011600118Light · inoperativeEMERGENCY CEILING LIGHT INOP 36F AND 43D. RELAMPED EMERGENCY CEILING LIGHT AT POS 36F(RT) AND 43D(LT). SYS OPS CHECKED NORMAL REF AMM 33-51-04.SDR CALA2016122601171Floorbeam · corrodedBS 325, RBL 33 - 55 FLOORBEAM UPPER TEE FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02, AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 ALLOWABLE DAMAGE 1, FIG 101. REPAIRED IAW SRM 53-00-51, REPAIR 2, FIG 201.SDR CALA2016122601170Floorbeam · corrodedBS 347 RBL 24-48 FLOORBEAM UPPER TEE FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 ALLOWABLE DAMAGE 1, FIG 101. REPAIRED IAW SRM 53-00-51, REPAIR 2, FIG 201.
Back to Boeing 767-424ER