Boeing 767-432ER
Service difficulty reports · 3,098
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1236101808Battery Pack · inoperativeMAINTENANCE DISCOVERED EMERGENCY LIGHTS FROM 36 AB TO 43 AB INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AND CHARGER PER B767-400ER AMM 33-51. OPS CHECKS OK.SDR DALA1233871815Connector · disconnectedEMERGENCY LIGHTS AT SEAT 18, 19, 20, 21GF INOPERATIVE. MAINTENANCE FOUND CONNECTOR DISCONNECTED.SDR DALA1233031801Battery · weakEMERGENCY EXIT SIGN NEAR 30AB/L3 DOOR DIM. MAINTENANCE FOUND BATTERY AT CHARGER M7236 WEAK AND REPLACED BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA1225831821Battery · dischargedCOCKPIT EMERGENCY EXIT SIGN IS INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA1225041811Power Supply · inoperativeDURING DAILY CHECK FOUND EMERGENCY PATH LIGHTS INOPERATIVE SEATS 38F TO 45F. REPLACED EMERGENCY POWER SUPPLY AT SEAT ROW 44F. SYSTEM OPERATION IS NORMAL.SDR DALA1219251816Battery Pack · dischargedDURING DRC FOUND LOWER DECK CREW REST EMERGENCY LIGHTS INOPERATIVE. CREW REST BATTERY PACK WAS BAD AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1217291809Light · inoperativeLLCR EMERGENCY LIGHTS IN 3 BUNKS ARE INOPERATIVE. FOUND 28V AT ALL LIGHTS. FOUND LED LIGHTS REV BIASED REV POLARITY IN FEMALE SIDE OF PLUG. CHECKS OK. LLCR EMERGENCY LIGHTS IN 3 BUNKS ARE INOPERATIVE.SDR DALA1209571801Power Supply · damagedDURING OPS 6803, FOUND EMERGENCY PATH BATTERY MOUNT CAMLOCK BROKEN ON POWER SUPPLY M6758. REPLACED POWER SUPPLY. SYSTEM OPERATION IS NORMAL.SDR DALA1209551801Battery Pack · failedBATTERY PACK M732 FAILED AND REPLACED. SYS OPS NORMAL.SDR DALA1209561801Battery Pack · failedDURING OPS 6803 BATTERY PACKS M730 M6756 M736 M737 M738 FAILED. REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1206351803Battery · dischargedDURING OPS 6804 BATTERIES AT LOCATION M739, M1208 M730 AND M1210 AND M734 NEEDS NEW BATTERIES. ALL BATTERIES REPLACED SYSTEM OPERATION IS NORMAL.SDR DALA1205001819Battery · dischargedEMERGENCY LIGHTS AT RO2 38AB AND 27AB AFT ARE INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY. SYSTEM OPS NORMAL.SDR DALA1204991814Fuse · defectiveEMERGENCY LIGHTS AT SEATS 1D-5D ARE INOPERATIVE. MTC T/S CHARGER FUSE IS BAD REPLACED SAME ALSO REPLACED BATTERY PACK AND CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA1204981806Connector · looseEMERGENCY PATH LIGHTS AT SEAT 21B ARE INOPERATIVE. MTC FOUND LOOSE CONNECTOR AND SECURED.SDR DALA1204241814Battery · defectiveEMERGENCY LIGHTS AT SEATS 1D - 5D ARE INOPERATIVE. FOUND BATTERY AT CHARGER M6756 BAD. REPLACED SAME PER 767-400 M/M 33-50.SDR DALA1202841807Power Supply · inoperativeTHE 4L AND 4R EMERGENCY PATH EXIT LIGHTS INOP. REPLACED PWR SUPP AND BATT AT 4R F/A SEAT AND TESTED PER B767400 M/M 33-51. MFG NBR S283W603-2. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPSSDR DALA1202751801Module · inoperativeDURING DRC MAINTENANCE FOUND L1 R1 DOOR EMERGENCY LIGHTS INOPERATIVE. POWER SUPPLY MODULE AT L1 DOOR WAS REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1201701819Battery · dischargedEMERGENCY LIGHTS AT SEAT 38AB ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA1204311812Harness · defectiveEMERGENCY PATH LIGHTS AT SEAT 27B ARE INOPERATIVE. JUMPER HARNESS WAS REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1201181814Light · inoperativeEMERGENCY FLOOR LIGHTING AS SEAT 43D IS DAMAGED OR INOP. MAINTENANCE REPAIRED EMERGENCY LIGHTING. SYSTEM OPS NORMAL.SDR DALA1201171812Battery Pack · dischargedEMERGENCY LIGHTS BATTERY PACK AT R4 IS INOPERATIVE. MTC REPLACED THE BATTERY PACK AND CHARGER. SYS OPS NML.SDR DALA1201081813Light · inoperativeEMERGENCY CEILING LIGHT AT SEAT 10D IS INOPERATIVE. MTC REPLACED THE LIGHT ASSEMBLY AT 10D. SYSTEM OPERATION IS NORMAL.SDR DALA1201071812Wire Harness · disconnectedDURING DRC MAINTENANCE FOUND EMERGENCY EXIT SEAT LIGHTS AT ROWS 22AB TO 26AB INOPERATIVE. THE SEAT HARNESS AT ROW 22AB IS DISCONNECTED AND RECONNECTED THE HARNESS. SYSTEM OPERATION IS NORMAL.SDR DALA1200401819Battery · dischargedEMERGENCY LIGTHS AT SEATS 38AB THRU 45AB ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY ON CHARGER M738. SYSTEM OPERATION IS NORMAL.SDR DALA1170981801Connector · looseEMERGENCY PATH LIGHTS AT ROWS 21-27 ARE INOPERATIVE. MAINTENANCE FOUND CONNECTOR D21160 LOOSE AND RE-SECURED. SYSTEM OPERATION IS NORMAL. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPSSDR DALA1171321812Hinge Fitting · crackedDURING OPN 5626AD MAINTENANCE FOUND THE RT O/B FLAP HINGE FITTING CRACKED AND REPLACED PER EA 14-086392-12AD REV B NE 04 OPN 401 AND 402.SDR DALA1170811810Fuse · blownEMERGENCY LIGHTS AT SEATS 22FG-27FG ARE INOPERATIVE. MAINTENANCE FOUND BAD FUSE ON POWER SUPPLY M732 AND REPLACED SYSTEM OPERATION IS NORMAL.SDR DALA1169881819Battery Pack · dischargedEMERGENCY AISLE LIGHT AND SEAT EMERGENCY LIGHT INOPERATIVE FROM ROW 38-45. MAINTENANCE REPLACED EMERGENCY BATTERY PACK 738 OPN. SYSTEM OPERATION IS NORMAL.SDR DALA1168951802Power Supply · inoperativeDURING DRC MAINTENANCE FOUND EMERGENCY LIGHTS INOPERATIVE AT 1D, 2D AND FWD GALLEY. THE POWER SUPPLY AT SEAT 1D WAS REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1167461803Fan · inoperativeSHORTLY AFTER T/O - F/AS REPORTED BURNING RUBBER SMELL IN THE CABIN. MAINTENANCE REPLACED RECIRCULATION FAN LOCATED IN MID GALLEY. SYSTEM OPERATION IS NORMAL. ETOPS CATEGORY 'B': DIVERSION OR TURNBACKSDR DALA1166911816Panel · corrodedFOUND DURING PSV, CORRODED WEB CLOSURE PANEL AT BS 955 AND LBL 90. REPAIRED PER ERA 498107-14. (ERA 498107-14)SDR DALA1165081820Battery Pack · dischargedON OP 6803 MAINTENANCE FOUND BATTERY PACKS AT M736, M737, M7M738 BAD AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1165061806Connector · disconnectedEMERGENCY LIGHTS AT SEATS 27FG AND 21FG ARE INOPERATIVE. MAINTENANCE RECONNECTED THE CONNECTOR AT SEAT 21FG. SYSTEM OPERATION IS NORMAL.SDR DALA1165071819Battery Pack · dischargedEMERGENCY LIGHTS FROM 30A TO 343 A OVERHEAD ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY AT SEAT 42A. SYS OPS NORMAL.SDR DALA1164191810Charger · inoperativeEMERGENCY PATH LIGHTS ROWS 35FG TO THE LAST ROW ARE INOP. MAINTENANCE FOUND BATTERY CHARGER AT POS M1734 FAULTS AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1164201811Battery Pack · not seatedEMERGENCY EXIT LIGHT OVER THE COCKPIT DOOR COMES ON INTERMITTENTLY. MAINTENANCE RESEATED THE BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA1166171807Pump · failedFLIGHT ATTENDANTS REPORTED LOUD BANG NOISE DURING TAXI IN AT R3. MAINTENANCE FOUND ADP FAILED AND DAMAGED TO FUSE AND COMPOSITE PANLS. ALL REPAIRED ON N/R CARD 1-5 PER ERA 497833-14 REV A FILE CODE 53-31.SDR DALA1164111809Guide · damagedFWD CARGO BIN FOUND ON ARRIVAL DAMAGE TO CARGO GUIDE DRIVE BAY D AREA 22 CENTER APPROX STA 570 GUIDE HAS BEEN RIPPED FROM FLOOR WITH SURROUNDING SHEET METAL DAMAGE. REPLACED FLOOR WEB AND SUPPORT BEAMS PER BOEING 767-400 DWG 451T2602.SDR DALA1162781808Connector · disconnectedEMERGENCY LIGHTS AT ROWS 12-17 ARE INOPERATIVE. MAINTENANCE RECONNECTED LIGHTS AT ROW 17. SYSTEM OPERATION IS NORMAL.SDR DALA1161951816Connector · not seatedEMERGENCY LIGHTS AT SEATS 32-38 ARE INOPERATIVE. MAINTENANCE RE-SEATED THE PLUG AT 31AB. SYSTEM OPERATION IS NORMAL.SDR DALA1161451815Bulkhead · corrodedDURING PSV8, FOUND CORROSION ON THE CANTED PRESSURE BULKHEAD WEB AT STA 955 AND LBL 85. WEB REPLACED PER PRI 491470-14.SDR DALA1161441818Wire · looseAFT GALLEY LIGHTS AND CE EMERGENCY EDGE LIGHTS ARE INOPERATIVE. MAINTENANCE TIGHTENED LOOSE WIRES. SYSTEM OPERATION IS NORMAL.SDR DALA1159631801Battery · dischargedON DRC MAINTENANCE FOUND THE EMERGENCY LIGHTS AT ROW 30AB - 44AB HAD A BATTERY FAULT AND REPLACED THE BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA1158531803Connector · disconnectedEMERGENCY WHITE PATH LIGHTS AT SEAT 21AB ARE INOPERATIVE. MAINTENANCE FOUND CONNECTER DISCONNECTED AND RECONNECTED. SYSTEM OPERATION IS NORMAL.SDR DALA1157161808Unknown · odorAFTER T/O DURING CLIMB CREW REPORT ELECT SMELL IN CABIN NEAR AREA OF E/E COMP. SMELL DID DISAPATE AFTER LEVEL OFF. RETURNED TO LHR FOR INVESTIGATION. PERFORMED NUMEROUS AMM CHECKS AND INSPECTIONS. ALL RECORDED IN THE LOGBOOK. RECIRC/GALLEY/GASPER FANS. ASDR DALA1156891809Light · inoperativeEMERGENCY LIGHT IN FRONT OF 1A IS INOPERATIVE. MAINTENANCE FOUND LIGHT MOUNTING INSERT PULLED OUT FROM BASE AND REPAIRED AND REPLACED THE LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR DALA1156711807Light · inoperativeMAINTENANCE FOUND ONE EMERGENCY LIGHT IN LOWER CREW REST FLIGHT ATTENDANT CONTROL PANEL INOPERATIVE. FORWARDED TO MCO33-51-01C. LOWER FLIGHT ATTENDANT CREW REST EMERGENCY LIGHTS OPERATE/TEST NORMAL WHEN REFERENCING STC APPROVED DOCUMENT TTF-07T048-40. OK FORSDR DALA1152481816Connector · disconnectedDURING DRC, MAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE FROM SEAT ROWS 38AB TO 42AB. MAINTENANCE FOUND PLUG AT 37B DISCONNECTED AND RE-CONNECTED IT. OPERATIONAL CHECK WAS NORMAL.SDR DALA1151061806Powerpack · inoperativeDURING PRE-DEPARTURE CHECK, MAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTING FROM SEATS 21FG TO 27FG INOPERATIVE. MAINTENANCE REPLACED POWER PACK AND RE-ATTACHED WIRING AT 21F. OPERATIONAL CHECK WAS NORMAL. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICALSDR DALA1151431814Charger · inoperativeDURING DAILY CHECK, MAINTENANCE FOUND THE 4L OVERHEAD EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE FOUND BATTERY CHARGER M739 INOPERATIVE. MAINTENANCE REPLACED BATTERY AND CHARGER. OPERATIONAL CHECK WAS GOOD.
Back to Boeing 767-432ER