SDR DALA1150851818Cable · disconnectedMAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTING FROM SEATS 17AB - 20AB INOPERATIVE. MAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHT CABLE DISCONNECTED AT SEAT 16. MAINTENANCE RECONNECTED SAME. OPERATIONAL CHECK WAS GOOD.SDR DALA1150421801Socket · dirtyMAINTENANCE FOUND THE EMERGENCY ESCAPE LIGHTS AT DOOR 3L, THE AISLE EXIT SIGN, AND OUTSIDE FUSELAGE LIGHTS ALL TO BE DIM. AFTER CLEANING BULB AND SOCKET OUTSIDE OF DOOR L3 THE OPERATION OF THE LIGHTS WAS NORMAL.SDR DALA1149981812Fuse · blownMAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE FROM SEATS 39A THROUGH 45A. MAINTENANCE REPLACED THE FUSE IN THE POWER SUPPLY.SDR DALA1149521805Fuse · blownMAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE BETWEEN SEATS 1A AND 5A. MAINTENANCE INSPECTED AND REPLACED CHARGER FUSES PER AMM. OPERATIONAL CHECK WAS GOOD.SDR DALA1148421809Connector · looseMAINTENANCE FOUND RIGHT SIDE SEAT EMERGENCY ESCAPE PATH LIGHTS AT ROWS 22-27FG TO BE INOPERATIVE. MAINTENANCE FOUND A LOOSE PLUG AT 21FG AND RECONNECTED IT. OPERATIONAL CHECK WAS GOOD.SDR DALA1147451803Charger · inoperativeMAINTENANCE FOUND SEATS 30AB THROUGH 39AB EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY CHARGER AT SEAT 32AB PER AMM. OPERATIONAL CHECK WAS GOOD.SDR DALA1146621803Battery Pack · dischargedMAINTENANCE FOUND ROWS 30 THROUGH 39 LEFT SIDE EMERGENCY ESCAPE LIGHTING INOPERATIVE. MAINTENANCE REPLACED EMERGENCY ESCAPE PATH LIGHTING BATTERY PACK AT ROW 32 PER AMM. OPERATIONAL CHECK WAS GOOD.SDR DALA1146931819Switch · overheatedOPERATING ON FLIGHT 14 FROM ATL TO FRA, RECEIVED A FORWARD EQUIPMENT OVERHEAT MESSAGE IMMEDIATELY AFTER TAKEOFF. PER THE QRH, THE CREW PUT THE EQUIPMENT COOLING SWITCH TO STBY. THE OVERHEAT LIGHT WENT OUT. THIRTY MINUTES LATER, AT CRUISE, THE ALTERNATE OVESDR DALA1144691814Fan · faultyEN ROUTE AT FL370, THE CREW SMELLED FUMES LIKE BURNING SHOE LEATHER IN THE COCKPIT AND CABIN AND DIVERTED TO FRA. THE LEFT RECIRCULATION FAN TRIPPED OFF AND THE SMELL SLOWLY DISSIPATED. MAINTENANCE FOUND THE LEFT RECIRCULATION FAN CIRCUIT BREAKER TRIPPED. ASDR DALA1144031813Connector · looseMAINTENANCE FOUND THE EMERGENCY ESCAPE PATH LIGHTS INOPERATIVE AT SEATS 22FG THROUGH 27FG. MAINTENANCE FOUND CONNECTOR LOOSE AT SEAT 21G AND RE-SECURED IT. OPERATIONAL CHECK WAS GOOD.SDR DALA1143891816Connector · looseMAINTENANCE FOUND THE EMERGENCY ESCAPE PATH LIGHTS INOPERATIVE AT SEATS 19FG - 22FG. MAINTENANCE FOUND CONNECTOR OUT AT SEAT 18FG AND RE-SECURED IT. OPERATIONAL CHECK WAS OK.SDR DALA1143361808Connector · looseMAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTS INOPERATIVE FOR SEATS 18, 19, AND 20AB. MAINTENANCE FOUND LOOSE CONNECTOR AND RECONNECTED. OPERATIONAL CHECK WAS NORMAL.SDR DALA1143371803Connector · disconnectedMAINTENANCE FOUND THE EMERGENCY ESCAPE PATH LIGHTS INOPERATIVE AT SEATS 23 - 27F. MAINTENANCE FOUND SEAT CONNECTOR AT SEAT 23F TO BE DISCONNECTED AND RE-SECURED IT. OPERATIONAL CHECK IS GOOD.SDR DALA1142971803Unknown · odorFLIGHT EXECUTED AN AIR TURNBACK AFTER THE FLIGHT ATTENDANTS REPORTED A STRONG ELECTRICAL SMELL IN THE GALLEY. WHEN THE BUN WARMER, CHILLER, AND ALL OUTLETS WERE TURNED OFF, THE SMELL WENT AWAY. MAINTENANCE COULD NOT DUPLICATE THE SMELL AND NO CIRCUIT BREAKERSDR DALA1143091807Connector · disconnectedDURING ACCOMPLISHMENT OF THE DAILY RELIABILITY CHECK, MAINTENANCE FOUND THE EMERGENCY ESCAPE PATH LIGHTS AT SEAT ROWS 16FG THROUGH 21FG INOPERATIVE. MAINTENANCE RESEATED THE CONNECTOR AT SEAT 16FG. OPERATIONAL CHECK WAS NORMAL.SDR DALA1140991810Charger · inoperativeMAINTENANCE FOUND EMERGENCY LIGHTS ON SEATS 22 THROUGH 27GF INOPERATIVE. MAINTENANCE REPLACED BATTERY CHARGER AT ROW 25G. MAINTENANCE ALSO FOUND WIRE DISCONNECTED AT ROW 22GF AND RECONNECTED IT. OPERATIONAL CHECK WAS NORMAL.SDR DALA1140561807Socket · inoperativeMAINTENANCE FOUND THE L4 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED THE LIGHT SOCKET AND THE OPERATIONAL CHECK WAS GOOD.SDR DALA1140411803Connector · disconnectedMAINTENANCE FOUND SEAT 23 THROUGH 27 RIGHT SIDE EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE FOUND PLUG AT SEAT23 KICKED OUT. MAINTENANCE RESEATED PLUG. EMERGENCY EXIT LIGHTS CHECK OK.SDR DALA1140431810Connector · inoperativeMAINTENANCE FOUND CEILING EMERGENCY LIGHTS AT A1 AND A3 INOPERATIVE. MAINTENANCE TRIED RE-LAMPING AND REPLACING THE BATTERY PACK. NO HELP AND MCO INSTALLED. MAINTENANCE REPLACED D10161 CONNECTOR PER AMM AND THE OPERATIONAL CHECKED GOOD.SDR DALA1139961811Sign · inoperativeMAINTENANCE FOUND PASSENGER SEAT 3D EMERGENCY EXIT SIGN INOPERATIVE. MAINTENANCE REINSTALLED EMERGENCY EXIT LIGHT. OPERATIONAL CHECK OK PER AMM.SDR DALA1139751814Connector · looseMAINTENANCE FOUND EMERGENCY LIGHT AT SEAT 21AB INOPERATIVE. MAINTENANCE REMOVED AND REPLACED SEAT 21AB EMERGENCY ESCAPE PATH LIGHT ASSEMBLY. NO HELP. FOUND THE CONNECTOR LOOSE AT SEAT 20AB. CLEANED AND RESEATED CONNECTOR. 21AB NOW CHECKS GOOD. NO OTHER DEFESDR DALA1139401806Connector · looseMAINTENANCE FOUND EMERGENCY LIGHTING FROM SEATS 21G THROUGH 27G INOPERATIVE. MAINTENANCE FOUND LOOSE CONNECTOR UNDER SEAT 21F. MAINTENANCE RECONNECTED LOOSE CONNECTOR. OPERATIONAL CHECK WAS GOOD. ALL LIGHTS CHECK OK.SDR DALA1138261815Ballast · defectiveTHE FLIGHT CREW REPORTED AN ELECTRICAL SMELL COMING FROM BEHIND LAVATORY 217 MIRROR. MAINTENANCE INSPECTED COMPARTMENT BEHIND LAVATORY MIRROR. MAINTENANCE FOUND THE LIGHT BALLAST TO BE HOT. MAINTENANCE DISCONNECTED THE BALLAST AND SMELL DISAPPEARED. NO FURSDR DALA1138141821Wire Harness · disconnectedMAINTENANCE FOUND EMERGENCY LIGHTS FROM ROW 15 THROUGH 20 AB INOPERATIVE ON SEATS. MAINTENANCE FOUND SEAT EMERGENCY LIGHT HARNESS DISCONNECTED AT SEAT 15. HARNESS WAS RECONNECTED. OPERATIONAL CHECK WAS NORMAL.SDR DALA1137381809Power Supply · burnedCABIN CREW DETECTED STRONG ELECTRICAL ODOR AND VISIBLE SMOKE IN FORWARD GALLEY AFTER ARRIVAL AT GATE. THE FLIGHT CREW PULLED THE UTILITY BUSSES AND CONTACTED MAINTENANCE. SMOKE DISSIPATED WITH UTILITIES OFF. MAINTENANCE FOUND THE NUMBER 2 COFFEEMAKER IN THESDR DALA1137411812Wire Harness · disconnectedSUPPLEMENTAL INFORMATION - MX EMERGENCY ESCAPE PATH LIGHTING SEAT MOUNTED AT 20F INOPERATIVE. MX VERIFIED SOCKET AND BULB OPERATE NORMALLY AND NOW SUSPECT THE WIRING HARNESS IN SEAT. MX FOUND HARNESS UNPLUGGED AND RESECURED IT. LIGHTS NOW CHECK OK.SDR DALA1137091815Connector · disconnectedMAINTENANCE FOUND IN SEAT EMERGENCY PATH LIGHTING ON ROWS 30AB THROUGH 37AB INOPERATIVE. MAINTENANCE FOUND CONNECTOR AT SEAT 30A DISCONNECTED AND RE-CONNECTED IT. ALL EMERGENCY PATH LIGHTING CHECKS NORMAL.SDR DALA1137071803Connector · disconnectedMAINTENANCE FOUND EMERGENCY LIGHTS ON SEAT 6A INOPERATIVE. MAINTENANCE FOUND CONNECTOR NOT INSTALLED AND RE-INSTALLED IT. OPERATIONAL CHECK IS GOOD.SDR DALA1133381818Altimeter · inaccurateAIRCRAFT 1818, ON INITIAL CLIMB OUT OF LHR ENROUTE TO MIA, THE CAPTAINS ALTIMETER DISPLAYED ERRONEOUS ALTITUDE INFORMATION, FLUCTUATING 250 FEET AT ALTITUDE. AN AIR TURN BACK WAS ACCOMPLISHED. FORWARDED TO MCO AND PLACARDED PER MEL 34-26-01A AND FOLLOWED MSDR DALA1132521821Fairing · delaminatedLHW OTBD FLAP OTBD L/E FAIRING FOUND DELAMINATED. COMPOSITE WET LAY UP REPAIR CARRIED OUT IAW SRM 57-53-01 REPAIR 1 TABLE 1 AND SRM 51-70-03 FIG 5.SDR DALA1130451817Fairing · delaminatedRT WING O/B FLAP I/B LEADING EDGE FAIRING WAS DELAMINATED AND REPAIRED PER SRM 57-53-01 REPAIR 1 TABLE 1 AND SRM 51-70-03 PAR 4A.SDR DALA1132771814Power Supply · inoperativeAIRCRAFT 1814, LINE MAINTENANCE FOUND EMERGENCY LIGHTS ON SEATS 15E AND F THROUGH 21E AND F INOPERATIVE. LINE MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK AT ROW 19. OPERATIONAL CHECK WAS NORMAL.SDR DALA1129731817Wedge · dentedNR 3 SLAT UPPER WEDGE O/B END IS DENTED AND REPAIRED PER SRM 57-43-02 REPAIR 1 FIG 201 AND SRM 51-70-10 REPAIR 4 FIG 201.SDR DALA1129721817Fairing · damagedRT WING O/B FLAP L/E NOSE FAIRING 666BT HAD A ELONGATED FASTENER HOLE AND WAS REPAIRED PER THE SRM 57-53-01 REPAIR 1 TABLE 1 AND SRM 51-70-03 FIG 10.SDR DALA1132531821Fairing · delaminatedLT WING OTBD FLAP INBD L/E FAIRING FOUND DELAMINATED. COMPOSITE WET LAY UP REPAIR CARRIED OUT IAW SRM 57-53-01 REPAIR 1 TABLE 1 AND SRM 51-70-03 FIG 5.SDR DALA1125391810Bulkhead · corrodedFUSELAGE STA 955 & LBL 85 CANTED PRESSURE BULKHEAD WEB AND STIFFENER/CORROSION. COMPLIED WITH ERA 491470-14 ON NR CARD 26.SDR DALA1123141808Screen · dirtyAIRCRAFT DIVERTED TO MIA BECAUSE OF A BUZZING NOISE AND ELECTRICAL ODOR IN AFT GALLEY. BOTH THE BUZZING NOISE AND THE ELECTRICAL ODOR DISSIPATED AFTER GALLEY POWER WAS TURNED OFF. MAINTENANCE REPLACED THE RIGHT AFT FLOOR LAMP. ADDITIONALLY, MAINTENANCE FOUNSDR DALA1123091811Unknown · odorAIRCRAFT EXECUTED A DIVERSION TO LHR DUE TO REPORTS OF A FUEL ODOR DURING CLIMBOUT IN THE FLIGHT DECK AND CABIN WITH THE PACKS OFF. ODOR DISSIPATED AFTER PACKS TURNED ON. MAINTENANCE REMOVED AND INSPECTED LEFT AND RIGHT PACK FLOW CONTROL VALVES, REMOVED OIL SDR DALA1126751802Aileron · crackedLEFT WING I/B AILERON L/E FAIRING I/B HINGE CUTOUT FOUND CRACKED. PREPREG LAY-UP HOT BOND REPAIR CARRIED OUT AT CRACKED AREA IAW SRM 57-60-01 REPAIR 1 SRM 57-70-05 FIG 6.SDR DALA1126361802Fairing · delaminatedLEFT WING I/B MID FLAP O/B LEADING EDGE NOSE FAIRING FOUND DELAMINATION. PREPREG LAY-UP HOT BOND REPAIR CARRIED OUT AT DELAMINATION AREA IAW SRM 57-53-01 REPAIR 1 AND SRM 51-70-05 FIG 5.SDR DALA1126351802Fairing · delaminatedRIGHT WING I/B MID FLAP O/B LEADING EDGE NOSE FAIRING FOUND DELAMINATION. PREPREG LAY-UP HOT BOND REPAIR CARRIED OUT AT DELAMINATION AREA IAW SRM 57-53-01 REPAIR 1 AND SRM 51-70-05 FIG 5.SDR DALA1123301802Floorbeam · corrodedSTA 325 RBL 26 TO RBL 54 FLOORBEAM FOUND CORRODED. REPAIRED PER SRM 53-00-51 REPAIR 1 FIG 201.SDR DALA1119341807Support Fitting · crackedLT WING NR 3 FLAP TRACK AFT FLAP FAIRING SUPPORT FITTING CRACKED. REPAIR C/W PER ERA 490810-14AD.SDR DALA1123651812Wedge · dentedLT WING NR 6 SLAT UPPER WEDGE EXTERNAL SURFACE FOUND DENT MARK. METAL HOT BOND REPAIR PERFORMED AS PER SRM 51-70-10, REPAIR 4 FIG 202.SDR DALA1119641805Light · inoperativeSEAT MOUNTED EMERGENCY ESCAPE PATH MARKER IS INOPERATIVE AT SEAT 37B. MAINTENANCE RE-LAMPED. HOWEVER PROBLEM STILL PERSISTED. IT IS CURRENTLY MEL'D PER 33-51-03A.SDR DALA1114351805Panel · missingPANEL 149AL MISSING FROM AIRCRAFT, INSTALLING ERA 490445-14.SDR DALA1118641819Wedge · chafedLT WING NR 5 SLAT WEDGE AREA T/E FOUND CHAFING. METAL HOT BOND REPAIR PERFORMED ON CHAFING AREA AS PER SRM 57-43-02 REPAIR I, FIG 201 AND SRM 51-70-10 REPAIR 4, FIG 201 AND 202.SDR DALA1119311819Fairing · delaminatedLT WING I/B MAIN FLAP O/B LEADING EDGE FAIRING FOUND DELAMINATED. COMPOSITE WET LAY-UP REPAIR CARRIED OUT AT DELAMINTED AREA IAW SRM 51-70-03 FIG 5 AND SRM 57-53-01 REPAIR.SDR DALA1119301819Fairing · delaminatedLT WING O/B FLAP I/B EDGE L/E FAIRING FOUND DELAMINATED. COMPOSITE WET LAY-UP REPAIR CARRIED OUT AT DELAMINATED AREA IAW SRM 57-53-01 REPAIR 1 AND SRM 51-70-03 PARA 5A (1) FIG 5.SDR DALA1119291819Skin · dentedLT WING O/B FLAP LWR SURFACE MID AREA FOUND DENT. METAL HOT BOND REPAIR PERFORMED AS PER SRM 57-53-01 REPAIR 1 FIG 201 AND SRM 51-70-10 REPAIR 2 FIG 203.
Back to Boeing 767-432ER