Boeing 767-432ER
Service difficulty reports · 3,098
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL764060504Connector · disconnectedSEAT 24FG/25FG EMERGENCY LIGHTS INOP. RELAMPED, NO HELP. FOUND CONNECTOR UNDER SEAT 24F DISCONNECTED. RECONNECTED, LIGHTS OPS NORMAL.SDR DL764060497Skin · dentedTHE FUSELAGE SKIN AT THE AFT SIDE OF THE BULK BIN DOOR HAS A 0.187 X 3.75 X 1.53 INCH DENT. THE DAMAGED SKIN WAS CUT OUT AND A REPAIR DOULBER WAS INSTALLED.SDR DL764060493Unknown · malfunctionedAPU AIR INOP FOR ENG START. RESTORED SHUT OFF VLV TO NORMAL. MANUALLY OPENED APU SHUT OF VLV, APU SHOT OFF VLV OPS NORMAL. PACK OPS NORMAL, DRY MOTOR ENGINES NO PROBLEMS. APU SHUT OFF WAS CYCLED APPROX 15 TIMES, NO DEFECTS NOTED. ASCTU BITE HAS NO CURRENTSDR DL764060579Circuit Card · defectiveON TAXI, RT ENGINE N1 IDLE 42 PCT N2 80 PCT. TS PER FIMM FOUND RT ENG EPCS PAGE SHOWS FLT IDLE DISCREET LASBLE 275 41CO FLT IDLE ON GRD TS AND FOUND CARD M644 BAD, SAME OPS GOOD MCO PLACARD REMOVED.SDR DL764060486Connector · not seatedR BLEED OFF LIGHT WOULD NOT EXTINGUISH. BIT ASCTU FAULTED R SIDE 36-13205 DID NOT SHOW ON LEFT RESEATED CONNECTOR PRSOV. RAN ENGINE, ALL PNEU OPS NORMAL.SDR DL764060489Turbine Blades · damagedPERFORM BORO OF NR 1 ENG DUE TO PRIOR EGT EXCEEDENCE. FOUND DAMAGE T1 BLADES AND END CAPS MISSING. REPLACED NR 1 ENG.SDR DL764060483Connector · contaminatedELEV FELL STATUS MSG ON AFTER ENG START. RESET SYM, NO HELP. CHECKED ELEV COMPUTER DRAINS OK, NO HELP. CHECKED HYS PRESS INDICATORS, NO FAULTS NOTED. CLEANED AND RESEATED CONNECTORS ON ELEV COMP, FOUND TO BE CONTAMINATED. RAN FULL ELEV CHECKOUT PER FIM, NSDR DL764060473Processor · unserviceableON TAXI OUT TCAS EICAS MESSAGE. RECYCLED BREAKER. STAYED ILLUM FOUND LOWER ANTENNA FAULT ON TEST, REPLACED TCAS PROCESSOR, CHECKS OK.SDR DL764060466Warning System · malfunctionedELEV FELL CAUTION ON TAXI OUT. PERFORMED ELEV FELL TESTS ON YSM'S. TEST PASSED.SDR DL764060463Cooling Fan · failedSLIGHT SMELL OF SMOKE FOLLOWED BY FWD EQUIP EXHAUST FAN STATUS MESSAGE. PULLED C/B P22 ON OVRD PANEL. NDS FWD EQUIP EXHAUST FAN NSAI HNL, SECURED C/B P11 P22 PULLED BY FLT CREW FWD INOP FWD EQUIP EXHAUST FAN TO MCO/PLAC PER MEL 21-58-04. REMOVED AND REPLACESDR DL764060459Battery Pack · unknownAS PER PILOTS REQUEST, INSPECT ALL EMERGENCY LIGHTS BATTERY PACK. CHECKED ALL EMERGENCY LIGHTS BATTERY PACK. REPLACED 7 TOTAL BATTERY PACKS, CKS GOOD.SDR DL764060458Battery Pack · dischargedEMERGENCY LIGHTS AT SEAT 2FE OVHD INOP. CHANGED BATTERY PACK AT ROW 2FE CKS GOOD.SDR DL764060446Fan · malfunctionedFWD EQUIPMENT FAN C/B POPPED IN FLT. FAINT ELEC BURNING MUCH DISSIPATED AFTER C/B POPPED. FWD TO MCO PER MEL 21-58-04 DISP APPR OK. REMOVED AND REPLACED RACK EXIT FAN P/N 211002542.SDR DL764060412Coupler · failedUNABLE TO GET RIGHT HFTO CHANNELIZE OR COMMUNICATE ON ANY FREQ. REPLACED NR 2 HF RADIO COUPLER TRANSMIT AND RECEIVE NORMAL ON 8843.SDR DL764060406Fan · failedSLIGHT ELECTRICAL SMELL NOTICED IN COCKPIT FOLLOWED BY RT RECIR FAN INOP MSG. REMOVED AND REPLACED RT RECIR FAN, CKS OK. REMOVED MCO AND PLACARD.SDR DL764060405Metering Valve · failedAFTER PUSHBACK AND ENG START, HEARD A WARNING HORN AT L1 DOOR AREA. FOUND SOUND FROM NOSE WHEEL STEERING METERING VALVE MODULE W HYD SYS PRESSURIZED. REPLACED STEERING METERING VALVE MODULE PE AMM 32-51-04. OPS CKD NORMAL.SDR DL764060371Connector · disconnectedFOUND EMERGENCY LIGHTS ON LT AILSE ROWS 27-32 INOP. FOUND WIRE DISCONNECTED AT ROW 27. RECONNECTED, LIGHTS OPN NML.SDR DL764060363Entertain Sys · odorREMOVED ENTERTAINMENT BOX 12F BURNING ELECTRICAL ODOR. INSTALLED DOWNLOADED AVU AT 12FG PER M/M.SDR DL764060332Idg · failedAFTER PUSH BACK LT IDG FAILED. REMOVED AND REPLACED IDG - GENERATOR CHECKS NORMAL. AFTER IDG REMOVED AND REPLACED - LT PACK INOPERATIVE. RESET PACK ALL CHECK GOOD. ETOPS CATEGORY (F): ANY OTHER EVENT DETRIMENTAL TO ETOPS.SDR DL764060328Rudder Control · noisyDURING TAXI OUT, FLT CONT CHK WITH FULL RUDDER DEFLECTION, METALLIC CLANG IS HEARD IN F/OS RUDDER PEDAL BAY. INSTALLED RIG PIN IN RUDDER SYS FWD PERF STATIC RIG CHK OF RUDDER CONT SYS FROM FWD QUADRANT TO AFT QUADRANT. ALL RIG PINS INSTALL AT QUADRANTS. REMOSDR DL764060298Skin · damagedFOUND ON ARRIVAL LEFT WING LWR LEADING EDGE PANEL DAMAGED. FOUND 3.5 INCH TEAR TO OUTER SKIN OF PANEL 521TB ON LEFT WING, MADE TEMPORARY REPAIR PER ERA 455217-14. PERMANENT REPAIR WITHIN 100 FLIGHT HOURS.SDR DL764060283Engine · malfunctionedAT APPROX 1500 AFTER T/O WHILE SELECTING CLIMB PWR FROM CLIMB 1, RT ENG SURGED ABOUT 3 TIMES 5 PCNT N1. LT ENG WAS NORMAL. RT ENG OPERATED NORMAL THE REMAINDER OF FLT. REMOVED BORO PLUGS FOR STAGE 1 AND STAGE 12 HPT BORO. C/W BORO PER AMM 72-00-00-206-096.SDR DL764060271Bulb · burned outL4 EXTERIOR EMERGENCY LIGHT INOP. RELAMPED, CHECKS GOOD.SDR DL764060267Window · malfunctionedHIGH SPEED ABORT DUE TO OPENING WINDOW F/O R2 SLIDING WINDOW. ABORT SPEED 130 KIAS. INSPECTED F/O`S R2 SLIDING WINDOW, OPS NORMAL. LATCH MECHANISM IS SECURE.SDR DL764060264Pseu · failedNUMEROUS EICAS MSG ON T/O INCLUDING GEAR DISAGREE, TAIL SKID FLAP DISAGREE, A/P DISCONNECT, R ICE DET, L ICE DET, R PDCU FAULT PSEU CARD 6-10 AND 11. REPLACED PSEU, CHECKS GOOD.SDR DL764060217Warning Message · false activationLEFT ENG BLEED OFF EICAS MESSAGE WITH EICAS LEFT BLEED VALVE FAULT WITH ENG OPERATING. RAN ASCTU, NO FAULTS NOTED. CYCLED ALL VALVES. RAN ENGINES, OPS NORMAL.SDR DL764060124Pump · leakingRIGHT ENG HYD RESERVIOR AND EICAS RIGHT HYD QTY AND A QUANTITY OF 4. FOUND NR 2 ENG HYD PUMP LEAKING. REPLACED PUMP PER MM. LEAK AND OPS CHECKS GOOD.SDR DL764060099Actuator · leakingFUEL LEAK FROM APU DRAIN MAST. FORWARD TO FLIGHT CREW PLACARD PER MEL 49-11-01B. AIRCRAFT FLOWN TO HNL TO MTC REPAIR APU. REPLACE IGV ACTUATOR PER M/M.SDR DL764060082Switch · inoperativeCENTER RIGHT HYD PUMP SWITCH INOP. REPLACED SWITCH PANEL.SDR DL764060041Bolt · missingLE SLAT ASYM MSG WHILE EXTENDING FLAPS TO 15 AFTER ENG START. FOUND SLAT 9 INBD TARGET MISSING. REPLACED SAME PER M/M. OPS CK NML.SDR DL764060037Washer · missingON TAXI OUT FLAPS AT 5 GOT L/E SLAT ASYM, RTB. FOUND NR 8 SLAT INBOARD TARGET/WASHER ASSY MISSING. REPLACED TARGET ASSY PER MM.SDR DL764060026Vane · wornNR 2 ENGINE REPLACED ATL OFF FLT 886/08 DUE 5 STG VANE WEAR. REPLACED NR 2 ENG.SDR DL764060025Battery Pack · dischargedDURING OPN 6803 FOUND ALL 16 BATTERY PACKS TO FAIL CHECK. PACKS ARE SUPPOSED TO LAST 15 MINUTES, LONGEST PACK LASTED 6 MINUTES. REPLACED 16 BATTERY PACKS, OPS CHECKS NORMAL. S/N'S LISTED BELOW 1) M730/12305, 2) M6756/12304, 3) M6757/12317, 4) M6758/51239, 5SDR DL764060014Module · failedL T/R ISOLATION VLV ALERT MSG. RECYCLED C/B L5 L6 L32 AND L33 FOR LT ENG THRUST REVERSER. DID TEST ON T/R RELAY MODULE. NO FAULTS NOTED. RESET MODULE EICAS MSG CLEARED. NO FAULTS NOTED.SDR DL764050819Fan · failedAT CRUISE FL340 APPROX 2345Z BEGAN TO SMELL AN ELECTRICAL TYPE BURN SMELL IN COCKPIT. REPLACED EQUIPMENT COOLING FAN.SDR DL764050750Receptacle · shortedDURING SERVICING OF F/C FWD LAV WHEN CLOSING MIRROR COMPARTMENT SHAVING OUTLET SPARKED. FOUND PREVIOUS REPAIR FAILED. OUTLET NOT SECURE DEACTIVATED F/C FWD SHAVING OUTLET.SDR DL764050749Line · leakingAT CRUISE, RT HYD QTY ADVISORY MESSAGE WITH SLOWLY DECREASING HYD QTY RT EDP AND RT DEM, PUMPED TURNED OFF RMD ACCESS PNL FROM FWD SPAR LT SIDE OF HORIZ STAB FOUND LT ELEV PRESS LINE DAMAGED. FABRICATED NEW SECTION AND RINGLOCKED IN PLACE PER M/M 20-10-09. ISDR DL764050740Odor · detectedF/A'S NOTICED ELECTRICAL SMELL BY ROW 40 LEFT SIDE OF CABIN. REPAIRED WIRING ON EMPOWER LAPTOP SYSTEM.SDR DL764050725Circuit Breaker · unknownAT CRUISE LOUD POP DOWN IN E&E COMPARTMENT FOLLOWED BY A DC STBY C/B POPPING AND LOSS OFF STBY POWER. RESET P6 PNL A2 C/B DC STBY INSPECTED E&E COMP FOR ABNORMALITIES CHECKS OK. STBY POWER TRANSFER OPS NORMAL. PERFORMED SHORT TEST PER M/M - NTF.SDR DL764050705Sensor · malfunctionedL/E ASYM MESSAGE DURING DESCENT BEFORE 250 KTS. FOLLOWED QRH PROCEDURES. HIGHEST BRAKE TEMP AT 6.0 NR 6 BRAKE. T/S PER FIM 27-81-00 FIG 107 PSEU FAULTS S295 TARGET FAR FAILURE WITH FAILURE LIGHT ON. REPLACED SENSOR S295 AND CHECKED PER MM.SDR DL764050683Spring · missingNOSE GEAR RT DOWNLOCK SPRING MISSING. REPLACED SPRING.SDR DL764050671Rudder Pedal · out of adjustRETURNED TO BLOCKS DUE TO ON TAXI OUT DURING FLT CONTROL CHECK OF LT RUDDER INPUT HEARD A LOUD BANGING SOUND. FOUND RUDDER PEDAL ADJ ALL THE WAY AFT WITH LT RUDDER INPUT OR RT RUDDER INPUT ON EITHER SIDE PEDAL HITS METAL COVER. ADJUSTED FULL FORWARD AND FULLSDR DL764050618Engine · failedLEFT ENGINE EGT STAYING AROUND 687 DEG CELSIUS AND N2 IS AT 75.5 ENG WILL NOT ACCEL. METAL SIZE OF BB-S CAN BE SEEN IN THE AFT TURBINE SECTION. BOROSCOPE REVEALED HPC DAMAGED. THE T/E OF THE HPT SHOWED EVIDENCE OF FOD DAMAGE. REPLACED ENGINE.SDR DL764050578Acm · failedAT FL330, 5 MINS INTO CRUISE, CABIN FILLED WITH SMOKE. A/C DIVERTED INTO OAK AND LANDED WITHOUT INCIDENT. FOUND LEFT ACM FAILED. FWD TO MCO AND PLACARD PER MEL 21-51-01.SDR DL764050562Engine · fireON CLIMB-OUT OGG AT 3000 FT, NR 1 ENG EGT WENT 997 - N2 OVERSPEED THE A/C SHUTTERED EXCESSIVELY DID NOT HAVE FIRE WARNING BUT C/W ENGINE FIRE OR SEVERE DAMAGE OR SEPARATION CHECKLIST AND FIRED ONE BOTTLE. FLT ATTENDANT REPORTS FLAMES OUT TAIL PIPE, DID SHUT DSDR DL764050542Connector · disconnectedEMERGENCY TRACK LIGHTS OUT AT SEATS 19AB-24AB AND 19FG-24FG. FOUND EMERGENCY TRACK LIGHTING CONNECTOR DISCONNECTED AT SEAT 19AB AND SEAT 19FG.SDR DL764050509Fan · failedATB - FUMES NOTED IN COCKPIT AND 1ST CLASS IN CLIMB. REPLACED FWD EQUIPMENT COOLING FAN.SDR DL764050506Cartridge · crushedON LANDING NORMAL SINK RATE SPEED BRAKE PARTIALLY DEPLOYED THEN RETRACTED. SUSPECT POSSIBLE TAIL STRIKE. REPLACED TAIL SKID CARTRIDGE.SDR DL764050485Connector · disconnectedFOUND EMERGENCY TRACK LIGHTS OUT BEHIND ROW 32CDE. FOUND CONNECTOR DISCONNECTED, RECONNECTED ALL, CHECKS NORMAL.SDR DL764050455Lock · looseDURING TAKEOFF NOTICED CAPTAINS RUDDER PEDALS SHIFT FORWARD ABOUT AN INCH, NORMAL T/O. INSPECTED PEDAL MECHANISIM AND TIGHTEND LOCK. PDEAL NOW LOCKS INTO DESIRED POSITION.
Back to Boeing 767-432ER