Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011111506238Spar · corrodedRIGHT WING REAR SPAR CORROSION BETWEEN IRSS 340 AND 350 AT FUEL BOOST PUMP. BLEND, DPI, HFEC IAW 777EN-57-0212.SDR UALA2011111506237Unknown · odorCREW REPORTED ELECTRICAL ODOR AROUND 4R LAV. CREW CHECKED THE LAV FOR SIGN OF ANY ELECTRICAL SMELL + TRASH BIN + LAV LIGHTS, NO ABNORMALITY NOTICED.SDR UALA2011111506257Solenoid · faultyRIGHT GEAR WON'T CLOSE. MAINT TEXT: TEXT SHOULD READ: RT MAIN LANDING GEAR DOOR WILL NOT CLOSE. REPLACED RIGHT MAIN GEAR DOOR RELEASE-SAFETY VALVE MODULE SOLENOID PER MM, OPS CHECKS GOOD.SDR UALA2011111506255Generator · faultyLEFT BUG FILTER BLOCKED MESSAGE ALONG WITH BUG DPI POPPED. LEFT BACKUP GENERATOR REPLACED ACCORDING TO MM.SDR UALA2011111506258Starter · leakingFOUND LEAK ON APU CLUSTER. FOUND OIL LEAKING FROM ELECTRIC STARTER. 1EA 651-0308, 7514051 LOB 891-14. 1EA 6510308, 751-4051 ISSUED MM. REPLACED STARTER MOTOR PER MM, NO LEAKS NOTED.SDR UALA2011111506256Boot · tornFOUND APU SURGE BLEED FLEX BOOT TORN. REPLACED FLEX BOOT.SDR UALA2011111506254Panel · damagedPANEL DAMAGED TOP OF VERT FIN AT TRAILING EDGE FIRST PANEL FWD OF RUDDER LT SIDE. PANEL HAS INTERIM REPAIR INSTALLED. REF IPC55-36-01-02 AREA A ITEM 35 THIS IS A VERTICAL STABILIZER TO RUDDER "SEAL". THIS SEAL (PANEL) WAS DAMAGED IN FLIGHT DUE TO HARDWARE WSDR UALA2011111506245Ace · malfunctionedFLT CTL SYS STATUS MSG. FOUND CB 'BATT INTLK' OPEN ON FACE OF PSA RIGHT, RESET AND TRIPPED AGAIN. PCN 566-9015. ACCOMPLISHED TROUBLESHOOTING PER MAINT MESSAGE 27-15102 FIM 27-02 TASK 851, FOUND ACE R M 27221 CAUSING CB D8-R AT POWER SUPPLY RIGHT M24201 POPPSDR UALA2011111406229Bushing · faultyNR 2 ENG S/N 222131 REMOVED DUE TO LOWER AFT MOUNT RAIL BUSHING REPLACEMENT. INSTALLED ENG S/N 222040 PER MM.SDR UALA2011111406203Spar · corrodedLEFT WING REAR SPAR CORR BETWEEN IRSS 340 AND 350 AT FUEL BOOST PUMP. BLEND, DPI, HFEC IAW AMECO 777EN-57-0213.SDR UALA2011111406202Gauge · looseNR 3 RT PAX ENTRY DOOR EPAS RESERVOIR GAUGE LOOSE. REMOVED AND REPLACED RESERVOIR.SDR UALA2011111406228Transceiver · inoperativeVHF C INOP WITH MSG "VHF DATALINK" ON UPPER EICAS. FOUND MSG 23-53003 IN P LF & FAULT HISTORY. T-S REF FIM 23-12 TASK 828. REPLACED VHF C & CKD MM AND GROUND TEST CENTER VHF COMMUNICATION SYSTEM --TEST PASSED. NO ACTIVE MSG.SDR UALA2011111406220Anti-Ice Valve · failedANTI-ICE EICAS, FLT DIVERTED. RPL EAI AND EAI CONTROLLER PER AMM, ENG RUNS SATISFACTORY.SDR UALA2011111406195Window · delaminatedWINDOW (FLIGHT DECK) - SHOWS SIGNS OF DAMAGE. CREW COMMENTS: DELAMINATING ALONG TOP EDGE. VISION NOT IMPAIRED. SAMC TEXT: DELAMINATION IS ON CO-PILOTS FORWARD WINDSHIELD UPPER EDGE AND IS ABOUT 8 INCES BY ABOUT 3 INCHES. ACP WINDOW REPLACEMENT AND WIRINGSDR UALA2011111406222Module · faultyTAT STATUS MSG DISPLAYED WITH GROUND PROX WINDSHEAR AND EPR INDICATION FAILING. MSG 34-25800. ACCOMPLISHED TROUBLESHOOTING PER FIM 34-21 TASK 809, REPLACED TAT PROBE PER MM & INPUT-OUTPUT MODULE (IOM) PER MM. MESSAGES CLEARED AND SYSTEM OPERATES NORMAL.SDR UALA2011111106173Sensor · out of adjustMAN PRESS LEFT MSG SHOW ON EICAS. DF PER MEL 3621A. -INF- :MSG SHOULD READS MAN PRESS SENSOR LEFT. -ADJ- :MSG 36-10480 LATCHED. PERFORMED FIM 36-21 TASK 805 AND GRD TEST PASSED. MSG ERASED AND NO FAULT NOTED.SDR UALA2011111106172Connector · dirtySTATUS MSG COND TEMP SENSOR R 21-23402. CLN'D THE LOW LIMIT VALVE CONNECTOR, MAT TEST PASSED.SDR UALA2011111106171Idg · faultyDURING ETOPS CK FOUND NR 1 ENG IDG OIL FILTER BLOCKED IND ON ELECTRIC PAGE. REPLACED NR 1 ENG IDG PER MM.SDR UALA2011111006137Bushing · migratedNR 2 ENG AFT ENGINE MOUNT SHOWS BUSHING MIGRATION AT 3RD BOLT INBD FROM OTBD SIDE, LOWER ROW. SAMC TEXT: WHATEVER HARDWARE IS REMOVED, SEND TO ENG MOUNT SHOP WITH EG-ALERT TAG, FOR FAILURE INVESTIGATION. NEED TO BE SURE THAT EVERYTHING THAT MAY HAVE CONTRIBSDR UALA2011111406227Amu · faultyDATA XFER FROM ACARS STILL BLEEDS THRU TO LEFT VHF RECEIVER. REPLACED AMU PER MM, OPS CHECK OKAY.SDR UALA2011111106151Life Vest · missingTHE 16F LIFE VEST IS MISSING. REPLACED LIFE VEST AT 16F.SDR UALA2011111006141Idg · malfunctionedRIGHT IDG DRIVE LIGHT ON NO VOLTS OR FREQ'S DOES NOT COME ONLINE. IDG OIL SHOULD BE CHANGED WHEN DEFERRAL IS CLEARED. REPLACED GCU PER MM. CHANGED IDG OIL AND RUN ENG PER JRH. NO VOLTAGE AND FR EA BUILT, NO HELP. SUSPECT IDG SHAFT SHEARED. REPLACED RT ENSDR UALA2011110906111Bearing · defectiveNR 2 ENG FAULT HISTORY SHOWS MAINTENANCE MSG MORE THAN ONCE IN 5 LEGS. NR 1 BEARING ACCELEROMETER SIGNAL OUT OF RANGE.
WITH THIS MSG OCCURING IN DESCENT, IT IS A NUISANCE, NO ACTION IS REQUIRED. ALSO, 483-0058 NR 1 BRG ACCELEROMETER IS AN INTERNAL ENGINE SDR UALA2011110906109Module · faultyLIGHTS IN BUSINESS CLASS WILL NOT DIM. REPLACED ZMU IN ZONE 2 PER MM, SYSTEM OPS CHECKED GOOD.SDR UALA2011111006144Computer · faultyPER A CHECK JC 2-2020B, MAINT MESSAGE REVIEW FOUND MAINT MSG 27-14008 PFC (CTR) LANE 3 HAS A FAULT HAS OCCURED MORE THAN ONCE IN LAST 5 FLT LEGS. :T/S PER FIM27-02 TASK 937, LANE WON'T RESET, TRIED NEW PFC BUT INCOMPATABLE OPS SOFTWARE INSTALLED, CAN'T DATA LSDR UALA2011110906113Float Valve · faultyK SCAVENGE SYSTEM FAILED THE HIGH LEVEL OUTLET FLOAT TEST. DURING TEST FUEL MOVED FROM THE CTR TO THE RIGHT MAIN TANK AT A RATE OF 100 LBS PER 12 MIN. REF CH2149 AND MM. REPLACED SCAVENGE LINE AND FLOAT VALVE. SCAVENGE TEST PASS.SDR UALA2011110906112Probe · faultyPER A CHECK JC 2-2020B MAINT MESSAGE REVIEW FOUND MAINT MESSAGE 75-40802 TCA THERMOCOUPLE PROBE (R ENG,CH A) SIGNAL IS OUT OF RANGE HAS OCCURED MORE THAN ONCE DURING LAST 5 FLT LEGS. REPLACED NR 2 ENG TCA THERMOCOUPLE PROBE.SDR UALA2011110906110Switch · faultyEMERGENCY EXT LIGHT SWITCH LOC ON NLG P40 PANEL FOUND TO BE NOT WORKING IN PROPER MANNER. FOUND ON WALK AROUND.
REPAIRED THE SWITCH, SYSTEM CHECKED OK.SDR UALA2011110906120Skin · damagedDAMAGED SKIN SECTIONS STA 740 & 780 REPAIR REQUIRES EVA 73159 BECAUSE OF ALTERED FASTENER SPACING AND DIAMETER AS NOTED IN EVA. FAILURE ANALYSIS TO BE COMPLETED WITHIN 24 MONTHS. REMOVE AIRCRAFT FROM SERVICE ON 3DEC 2011 UNLESS AN 8100-9 IS RECEIVED THAT APPSDR UALA2011110906119Plate · contaminatedBUSINESS CLASS GALLEY SMOKE SMELL COMING FROM VENTS. CHECKED ALL COMPONENTS IN AREA, NO DEFECTS NOTED, F/A REPORTED WHITE SMOKE RISE TO GALLEY VENT, SUSPECTED STEAM FROM WET HOT PLATE FROM A COFFEEMAKER. FOUND ANOTHER OFF HOT PLATE NEAR BY STILL WET.SDR UALA2011110806088Sliding Window · noisyHIGH PITCH TONE AUDIBLE TO BOTH PILOTS IN CRZ. MAYBE CAPTS WINDOW. CREW VERBAL SLIGHT NOISE COMING FROM BOTTOM AFT CORNER OF CAPTS SLIDING WINDOW. FOUND EXCESSIVE AMOUNT OF SEALANT ON INSIDE OF AFT BOTTOM CORNER. REMOVED EXCESSIVE SEALANT. NOISE RECURRED.SDR UALA2011110906094Seal · damagedWATER LEAKING ABOVE DOOR 3L AT 40 DROPS PER MIN. APPEARS TO BE COMING FROM THE HGA PORT L M23093 CONNECTOR. FOUND AREA OF SEALANT ON THE UPPER EDGE OF ANTENNA MISSING, SCRAPED AREA, RESEALED UPPER EDGE & APPLIED TAPE OVER AREA OF SEALANT. ACP A REPAIR WITHISDR UALA2011110906107Drive Unit · faultyUNCOMMANDED A-P DISCONNECT 5 HOURS 45 MINUTES AFTER T/O. FL400 MACH .83. REPLACED WX DRIVE UNIT, MAINT MSG 34-44032. ACCOMPLISHED FULL CAT 3 TEST PASSED.SDR UALA2011110906115Pressure Switch · faultyENG OIL FILT SNSR L THE PRESSURE SWITCH FOR DETECTING IMPENDING OIL FILTER BYPASS ON THE LEFT ENGINE HAS FAILED. STATUS MSG01- ACTIVE CRUISE MODE DEPENDENT; SWITCH POSITION SIGNAL FROM OIL FILTER DIFFRNTL PRESS SW (L ENG) CHANNEL A AND B DO NOT AGREE. DB- ESDR UALA2011110706030Skin · damagedFUSE EXT SURFACE LIGHTNING STRIKE STA 498 S8R. REMOVED DAMAGE. HFEC FABRICATED AND INSTALLED REPAIR IAW SRM REPAIR 3. FASTENER HOLES NOT ZERO TIMED. MARKED REPAIR IAW GNMM 1-0-1-7. PER SRM PG 216 (EFS 59), TABLE 204, REINSPECT BEGINNING AT PTC 30,000.SDR UALA2011110706032Skin · dentedFUSELAGE EXT SKIN DENT STA 346 ONE INCH BELOW S9R. MAJOR REPAIR ACCOMPLISHED: RMV'D DAMAGE. HFEC FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-01 REPAIR 3. FASTENER HOLES NOT ZERO TIMED. MARKED REPAIR IAW GNMM 1-0-1-7. PER SRM PG 216 (EFS 59), TABLE 204,SDR UALA2011110706031Skin · damagedFUSE EXTERNAL SKIN LIGHTNING STRIKE STA 785 S6R - S7R 3 EACH. REMOVED DAMAGE. HFEC FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-01 REPAIR 3. FASTENER HOLES NOT ZERO TIMED. MARKED REPAIR IAW GNMM 1-0-1-7. PER SRM PG 216 (EFS 59), TABLE 204, REINSPECT BEGISDR UALA2011110706069Clamp · brokenDURING WAC FOUND CLAMP BROKEN ON LT MAIN LANDING GEAR ACTUATOR. TEMPORARY REPAIR C-OUT PER EVA NUMBER UA-EVA-81464. AFTER EVERY FLIGHT CYCLE ACCOMPLISH REPETATIVE VISUAL INSPECTION PER EVA INSTRUCTION STEPS 1 AND 2. WITHIN 2 FLT CYCLES NOT TO EXCEED PTC 11SDR UALA2011110706024Wire · unsecureWIRE LOOP ON EMERG EXIT LIGHT SW IS INOPERATIVE. SECURED WIRE LOOP OPS CHECK OKAY. LIGHT ARMED WHEN SWITCH GUARD IS PUSHED.SDR UALA2011110706063Pump · inoperativeHYD PRESS PRI C2 INOP. ALSO ON STATUS PAGE. REPLACED C2 HYD PUMP PER MM.SDR UALA2011110706049Fan · faultyLEFT GALLEY FAN LEFT EICAS. REPLACED LEFT LAV GALLEY VENT FAN AS REQUIRED. OPS CHECK NORMAL AT THIS TIME.SDR UALA2011110706039Actuator · faultyFOUND STS MSG APU DOOR, APU STILL WORKING, INLET DOOR FULLY OPEN. REPLACED APU DOOR ACTUATOR.SDR UALA2011110706064Controller · faultyANTI-ICE ENG L LEFT ENGINE ANTI-ICE (EAI) VALVE FAILURE TO THE CLOSED POSITION OR LEFT EAI CONTROL CARD FAILURE. COMPLETED CHECK OF EAI TUBING FOR LEAKS. LINES CHECK OKAY & REPLACED ENG ANTI-ICE VALVE CONTROLLER. COMPLETED 30 AIRFOIL COWL ICE PROTECTION SYSSDR UALA2011110706055Igniter Box · faultyAPU START SYS STATUS MESSAGE. APU IS RUNNING AND USEABLE. APU IGNITER BOX ON ORDER OSTF U3444. REPLACED IGNITER BOX, OPS CHECK GOOD.SDR UALA2011110706054Plug · burnedNR 1 AND 2 APU IGNITER PLUGS BURNED FROM ARCING. INSTALLED NEW PLUGS.SDR UALA2011110706053Lead · burnedNR 1 AND 2 APU IGNITER CABLE ENDS AT IGNITER PLUG BURNT FROM ARCING. INSTALLED NEW LEADS 1 AND 2 PER MM.SDR UALA2011110706052Window · faultyWINDOW HEATER RT NR 3 MSG 30-23012 ON EXISTING FAULT. HISTORY SHOWED HIT ON EVERY LEG FOR THE LAST 21 LEGS. REPLACED 3R WINDOW ACCORDING TO MM. OPS CHECKED GOOD, NO MESSAGES.SDR UALA2011110706008Valve · faultyFUEL IMBALANCE OF 1400LBS BETWEEN MAIN TANKS 5 HRS INTO FLIGHT. LT 64.0 AND RT 65.4 AND CENTER TANK FUEL STILL BEING BURNED. ENGINE FUEL FLOW EVEN BETWEEN ENGINES THROUGHOUT FLT INFORMATION ONLY FROM CREW DUE TO FUEL IMBALANCE HISTORY. ACCOMPLISHED SCAVENGESDR UALA2011110405997Unknown · malfunctionedAPU CONTROL MESSAGE PRESENT. MESSAGE 49-10760. "ELECT. MOTOR HAS BRUSH WEAR" --INF- :NOTE: APU ELECT STARTER & START CONTACTOR REPLACED 16OCT2011 FOR SAME MSG. REF: FIM 49-40 AND PERFORM TASK 807 ESPECIALLY THE PIN, WIRE CHECKS. IF SIGNED OFF AS "OPS OK" IT SDR UALA2011110706057Duct · blownLEFT PACK NOT OPERATING WITH SWITCH ON FOUND LFT PACK DUCT BLOWN. REPLACED DUCT ASSY, OPS CHECK GOOD.