SDR CALA2025021102291Arming Lever · fodDELAY REPORTING, ITEM ENTERED TO FLAG A MAINTENANCE DELAY: .. .DOOR 4L WILL NOT ARM, MECHANIC CLEANED DEBRIS AND DOOR ARMIMG OPERATION OKSDR CALA2025021002268Light · damagedEMER PATH LIGHTING AT 18G DAMAGED SECURED EMEGENCY PATH LIGHT 18G TO SEAT ENDBAY. REF AMM 33-51-05-960-802SDR CALA2025021002247Sign · detached4R EXIT SIGN FALL OUT OF CEILING. REPLACED LIGHT ASSY AND COMPLETED ASSOCIATED FUNCTIONAL TESTS - TESTS PASS. AMM33-52-01SDR CALA2025020702229Sensor · faultedPACK FCV LWR R EICAS STATUS THE LOWER RIGHT PACK FLOW CONTROL VALVES (FCV) IS NOT IN THE COM MANDED POSITION. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2124304 FLIGHT STATUS: L INTERMITTENCE CODE: M PH: CLIMB NARRATIVE: CABIN TEMPERATURE CONTR OLLSDR CALA2025020500303Battery · no testL4 DOOR EMERGENCY LIGHT POWER SUPPLY BATTERY PACK OUT OF LIMIT D URING CAPACITY CHECK - ORIGINATED BY EMP V903218 ON HAECO NR 94 56232, RAISED FROM WORK CARD 85-3351-1-7003. PERFORMED BY EMP V903670, REPLACED THE FR 4L EMERGENCY LT POWER SUPPLY BATTERY PACK MSDR CALA2025020702233Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - EMERGENCY AREA LIGHTS IN MID GALLEY CEILING AND IN AFT GALLEY CEILING ABOVE FLT ATTENDANTS SEATS INOP RELAMPED PER AMM 33-51-03-960-801 CK OK.SDR CALA2025020502206Unknown · odorON FINAL EICAS SMOKE REST UPR DR 3. ELECTRICA L ODOR BUNK 5. RES ET DON PER FLT DECK CREW: EICAS "SMOKE REST UPR DR3" AT 5000' ON APPROACH. CABIN CREW ADJACENT TO AFT ATTENDANT OVHD REST DID NOT SMELL SMOKE. AT TAXI IN, CABIN CREW INVESTIGATED AND REPORTED FAISDR CALA2025020502208Apu · faultedFLIGHT ATTENDANTS CLAIM THEY SMELLED AN ELETRIC SMELL LANDING RE PEAT WU SMOKE AND ODOR QUESTIONAIRE ATTACHED INVESTIGATED CABIN, TURNED ON EVERYTHING ELECTRICAL INSIDE AND DID FULL SWEEP OF CABIN, NO ODOR DETECTED. STARTED APU AND OPERATED 1 PACK AT A TIME, OSDR CALA2025020400288Intercostal · crackedSUPPORT TASK - NO.2 PYLON PNL #443CL CUTOUT INNER UPR INTERCOSTAL FOUND CRACK. NO.2 PYLON PNL NO.443CL CUTOUT INNER UPPER INTERCOSTAL REPLACED AS PER SRM 51-10-02 AND FASTENER INSTALLED AS PER SRM 51-10-02.SDR CALA2025020400287Skin · crackedSUPPORT TASK NO.2 PYLON I/B PNL 443CL CUTOUT SKIN FOUND SUSPECT CRACKED. WORK TRANSFER NON ROUTINE WO.4342845. DIP TO INSPECT THE REPAIR AREA AT #2 PYLON I/B STRUT SKIN AT 5450-02988 PART 2 ON OR BEFORE 02 FEBRUARY 2027 443CL ACCESS DOOR CUTOUT PER THE LATEST SDR CALA2025020200266Battery Pack · no testREPLACE DR R3 M33404 EMER LIGHT BATTERY EMER LIGHT BATTERY REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06.SDR CALA2025020200265Power Supply · no testREFER PICK UP SHEET HX NRC WO.4386846 PWR SUPPLY REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06.SDR CALA2025020200264Battery Pack · failedREFER PICK UP SHEET HX NRC WO.4386846. EMER LIGHT BATTERY REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06.SDR CALA2025020200250Battery · no testLLAR EMER LT BATTERY TEST FAIL. EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2025020200249Charger · failedLLAR EMER LT BATTERY CHARGER TEST FAILED. EMER LT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V946812 INSPECTED BY V897004SDR CALA2025013102149Unknown · odorELECTRICAL SMELL / CHEMICAL SMELL IN THE COACH LEFT SIDE OF A/C. REVIEWED SMOKE AND ORDOR FORM WITH CREW. INSPECTED AFT CABIN AND GALLEY FOR IRREGULARITYS NONE NOTED CHECKED GALLEY EQUIPMENT LIGHTS AND C/BS. NON OPENED. NO SMOKE OR ODORS NOTED. CHECKED FWD E/ESDR CALA2025013102144Trim Panel · damagedCELL PHONE FIRE UNDER 2D DAMAGE TO TRIM FIRE IS OUT. PASSENGER REPORTED PHONE FELL BEHIND SEAT WHILE ASLEEP. WHILE MOVING SEAT TO TTL MODE PHONE CAUGHT BETWEEN SEAT TRACK REMOVED SEAT BACK. FA AND PAX REPORTED THAT SMOKE COMING UNDER THE SEAT, AND THERE WERESDR CALA2025012902107Skin · dentedRAMP REPORTS DENT ON BULK CARGO DOOR PATCH. ACCOMPLISHED STEPS 1-3 OF AVO14038 REV B. NO OTHER DAMAGE AT THIS TIME AND ALL FASTENERS ARE SECURED. EXTERNAL REPAIR WILL BE THE MAP OUT FOR ESC FABRICATED AND INSTALLED NEW REPAIR ON RH BULK DOOR IN REF TO ECRA5230SDR CALA2025013102155Switch · out of adjustDOOR FLIGHT LOCK 4R EICAS STATUS #4 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SEN SOR DISAGREEMENT. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 5211350 FLIGHT STATUS: I INTERMITTENCE CODE: I PH: CLIMB NARRATIVE: PSSDR CALA2025013102151Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - SEAT 1G FLOOR PROXIMITY EMERGENCY LIGHT INOP REPLACED LAMPS ON PROX EMER LIGHT. OPS CHECK GOOD.SDR CALA2025013002116Bulb · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - DOOR L3 EMERGENCY AREA LIGHT INOP REPLACED LAMP. OPS CHECK GOOD OF L3 DOOR EMERGENCY LIGHT.SDR CALA2025012702054Relay · faultedTRANSIENT ELECTRICAL SYSTEM FAULTS AND RESETS MULTIPLE SYSTEMS A FFECTD INBOUND FDE LEFT MAIN AC BUS IS NOT POWERED IN P100 SEE LEFT MAIN AC BUS NOT POWERED PROBLEMS - FAULT ISOLATIONREFERENCE: 24-51 TASK 822 REV NO. / DATE : 103 / 05 JAN 2025 APPLICABILITY: USDR CALA2025012301975Battery Pack · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - R2 DOOR FWD EMERGENCY EXIT IDENTIFIER SIGN AND ASSOCIATED AISLE PATH EMERGENCY LIGHTS INOP PERFORMED EMERGENCY BATTERY PACK CHARGING PROCEDURE FOR 90 MINUTES REF AMM SUBTASK 33-51-00-860-00SDR CALA2025012402021Girt Bar · disengagedDOOR 1L GIRT BAR HAS BECOME DISENGAGED FROM PRONGS AT AFT END. BUSTLE HAS BEEN REMOVED, PINS INSTALLED. RENDER SAFE CHECKLIST IS OUT-OF-SYNC DUE TO UNINTENTIONAL CIRCUMSTANCES. REMOVED DEBRUIS AND CLEANED FLOOR FITTING APPLYED LUB AND CYCLED DOOR 1L SEVERAL TISDR CALA2025012300184Battery Pack · dischargedM/D L3 DOOR AFT EMERGENCY POWER SUPPLY M33405 POWER PACK FOUND M ALFUNCTION REF TO HAECO NON-ROUTINE NO.9455100, REPLACED M/D L 3 DOOR AFT EMERGENCY POWER SUPPLY M33405 POWER PACK AND C/O NEW PACK TEST. THE RESULT FOUND NORMAL AS PER AMM 33-51-06-960-802 R ESDR CALA2025012402012Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - R3 , R4 (EXTERIOR) SLIDE LIGHT INOP RELAMPED PER AMM 33-51-04-960-801 CK OK PARTS USED: 767,QTY :1SDR CALA2025012100156Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK (M33424) LOW CAPACITY, REPLACED EMERGENCY LIGHT BATTERY PACK ( M33424) AND PERFORM INSTALLATION TEST,RESULT IS NORMAL REF AMM 33-51-06-960-802 REV 102.SDR CALA2025012100155Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK (M33097) LOW CAPACITY, PERFORMED BY EMP V903685,REPLACED EMERGENCY LIGHT BATTERY PACK ( M33097) AND PERFORM INSTALL TEST,RESULT IS NORMAL,REF AMM 33-51- 06-960-802 REV 102.SDR CALA2025011701945Warning Message · illuminatedGEAR DISAGREE EICAS CAUTION 1. ONE OR MORE LANDING GEARS ARE NOT UP AND LOCKED, 40 SECONDS A FTER GEARS ARE SELECTED UP. 2. ONE OR MORE LANDING GEARS ARE NOT DOWN AND LOCKED, 40 SECONDS AFTER GEARS ARE SELECTED DOWN. FIM TASK REF : FIM TASK REFERENCE NOT FOUNDSDR CALA2025011700142Longeron · crackedAD2019-11-02 - SUPPORT TASK - EA 5310-07557 REV B OP 002 - LH UNDERWING LONGERON 1EA HOLE FOUND CRACK AT FWD CARGO RING CHORD TRANSFER REF. NON-ROUTINE HX NRC WO.4219991 AND EA 5310-07557 REV B OP 002 LH UNDERWING LONGERON FWD CARGO RING L/P NO.3547739 CREATEDSDR CALA2025011700141Longeron · crackedAD2019-11-02 - SUPPORT TASK - EA 5310-07557 REV B OP 002 - LH UNDERWING LONGERON 1EA HOLE FOUND CRACK AT WEB TRANSFER REF. NON-ROUTINE HX NRC WO.4219977 AND ORIGINATED BY EMP NO. V906013 EA 5310-07557 REV B OP 002 LH UNDERWING LONGERON CENTER TANK L/P NO.35478SDR CALA2025011700140Longeron · crackedEA 5310-07557 REV B OP 002 (AD 2019-11-02) LH UNDERWING LONGERON CENTER TANK FRONT SPAR CHORD 1EA HOLE FOUND CRACK AT 5, 7 & 10 O`CLOCK WITH 3/16" IN DEPTH (DETAIL REF NDT INSP FINDING RECORD) TRANSFER REF. NON-ROUTINE HX NRC WO.4213299 AND EA 5310-07557 REV SDR CALA2025011300108Frame · crackedEA 5380-01113 REV B OP 020 - RH BS2370 PIVOT BULKHEAD FWD CHORD 1EA FASTENER HOLE FOUND CRACK. . FUSELAGE RH BS 2370 PIVOT BULKHEAD FWD CHORD REPLACED AS PER EA 5380-01113 REV B OP 024.SDR CALA2025011300107Battery Pack · inoperativeDR R2 M33097 EMER LIGHT PWR SUPPLY BATTERY TEST FAIL DR R2 M33097 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06.SDR CALA2025011300106Charger · no testDR R2 M33097 EMER LIGHT PWR SUPPLY BATTERY CHARGER TEST FAIL. DR R2 M33097 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2025011300104Battery Pack · no testDR L1 M33424 EMER LIGHT BATTERY TEST FAIL. DR L1 M33424 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06.SDR CALA2025011300103Charger · no testB777-33-3-7019 - DR 2L M33099 EMER LT PWR SUPPLY TEST FAIL. DR 2L M33099 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06 DETAIL REFER ATTACH FORM 44-0008 STEP 1 TO 2 ACCOMPLISHED .SDR CALA2025011300102Battery Pack · no testB777-33-3-7019 - DR 1R M33094 EMER LT BATTERY TEST FAIL. WORK. DR 1R M33094 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL I.A.W 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED.SDR CALA2025011300101Battery Pack · no testB777-33-3-7019 DR 2L M33099 EMER LIGHT BATTERY TEST FAIL. DR 2L M33099 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL I.A.W. AMM 33-51-06 DETAIL REFER ATTACH FORM 44-0008, STEP 1 TO 2 ACCOMPLISHED.SDR CALA2025011300105Charger · inoperativeDR 1L M33424 EMER LT PWR SUPPLY TEST FAILED. EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL I.A.W AMM 33-51-06.SDR CALA2025011300110Skin · crackedSUPPORT TASK - EA 5310-07557 REV B OP 002 (AD 2019-11-02) LH UNDERWING LONGERON FUS SKIN 2EA HOLE FOUND CRACK (DETAIL REF NDT INSP FINDING RECORD). FUSELAGE LH SKIN AT STA 993-1035 BETWEEN STR-35L AND STR-37L MODIFICATION WITH DOUBLER AND REPAIR FILLER INSTALSDR CALA2025011300109Skin · crackedSUPPORT TASK - EA 5330-07074 REV B OP 001 STEP 3, CRACK FOUND ON L/H FUSELAGE SKIN. ACCOMPLISH EA 5310-07557 OP1 AND OP2 FOR MODIFICATION. FUSELAGE LH SKIN AT STA 993-1035 BETWEEN STR-35L AND STR-37L MODIFICATION WITH DOUBLER AND REPAIR FILLER INSTALLATION ASSDR CALA2025011001866Slide Raft · unwanted deployL1 DOOR OPENED WITH SLIDE IN ARMED POSITION RESULTING IN SLIDE PARTIALLY DEPLOYED BUT NOT INFLATED DUE TO DOOR HELD IN PARTIAL OPEN POSITION. REPLACE L1 DOOR SLIDE. L1 DOOR SLIDE REQUIRES INSPECTION. REPLACED L1 DOOR SLIDE REF AMM 25-66-01-400-801. AND INSTALLSDR CALA2025010601818Engine · smokeEXCESSIVE SMOKE FROM NUMBER TWO ENGINE INLET UPON ARRIVAL AT THE GATE. PERFORMED DVI OF #2 ENGINE INLET EXHAUST AND UNDER COWLING AND FOUND NO EXTERNAL OR INTERNAL LEAKS. PERFORMED #2 ENGINE IDLE RUN TEST AND FOUND WHEN CUTOFF SWITCH WAS PLACED TO RUN F/D INDISDR CALA2025010601789Pump · faultedINFLIGHT SHUTDOWN NO 2 ENGINE OIL PRESSURESNAPSHOT AHM CREW WAS DEBRIEF THIS IS AN UPDATE FROM TURN OVER SHIFT DEBRIEFING THAT THE RIGHT OIL PRESSURE CAUTION IN FLIGHT WITH CORRESPONDING RIGHT LOW PRESSURE INDICATION ALONG WITH 0 OIL QTY SHOWING, OCCURED AT 40SDR CALA2025010601803Girt Bar · fod1L DOOR ARMING INDICATION IS ABNORMAL INSPECTED AND CLEANED DOOR 1L GIRT BAR LOWER DOOR ARMED INDICATORS, CYCLED ARM LEVER SEVERAL TIMES, CHECKS OK, REFERENCE: TASK 52-11-17-200-801.SDR CALA2025010301767Steering Sys · warning lightMAIN GEAR STEERING STATUS AND GEAR CONFIG WARNING ILLUMINATED HAD FLIGHT CREW OPERATE STEERING FULL LEFT AND RIGHT MSG CLEARED OPS CKS OK PER AMM 32-53-03 LOG PAGE UPDATE WITH CORRECT FIM 32-53 TASK 811SDR CALA2024123003197Battery Pack · no testEMER BATT PACK M33098 DEEP CYCLE TEST FAILED. EMER BATT PACK M33098 REPLACED AND TESTED FND NORMAL AS PER AMM 33-51-06.SDR CALA2024123003196Battery Pack · no testEMER BATT PACK M33409 DEEP CYCLE TEST FAILED. EMER BATTERY PACK M33409 REPLACED AND TESTED FND NORMAL AS PER A MM 33-51-06.SDR CALA2024123003195Power Supply · no testLLAR BATTERY PACK M023 DEEP CYCLE TEST FAILED. EMER POWER SUPPLY M023 REPLACED AND TESTED FND NORMAL AS PE R AMM 33-51-06 ATTACHED FORM 44-0008 ITEM 1-2.
Back to Boeing 777-222