Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011042902090Heat Exchanger · crackedRIGHT AIR COND HEAT EXCHANGER IS CRACKED. REPLACED HEAT EXCHANGER PER MM, OPS CHECKED GOOD.SDR UALA2011050202138Shutoff Valve · leakingRUNNING HYDRAULIC LEAKAGE AT CTR SYS WING FLIGHT CONTROL SHUTOFF VALVE AT LT MAIN LANDING GEAR WHEEL WELL. FOUND INLET VALVE (LOWER) TUBING LEAKING. AFTER TIGHTENING GOT LEAKAGE TO 1 DROP PER MINUTE. NOW ITS WITHIN DISPATCH LIMITS AS PER AMM. SUGGEST TUBE SDR UALA2011042902092Apu · faultyAPU AND APU DOOR EICAS MESSAGE, NO START. REPLACED APU AND OPS CHECK NORMAL PER MM.SDR UALA2011042902100Shutoff Valve · faultyPRSOV R...STATUS MSG CAME ON SHORTLY AFTER START OF DESCENT. MX MSG 36-10380. REPLACED RT ENG PRSOV PER MM. PERFORMED OPS CHECK PER MM. OPS CHECK NORMAL.SDR UALA2011042902086Data Box · inoperativeSATCOM SYSTEM SATCOM SYSTEM FAILS OR NO BUSS ACTIVITY. STATUS MESSAGE 01- ACTIVE CRUISE HARD; SATELLITE DATA UNIT (LEFT) HAS NO OUTPUT ON ANY BUSS. MSG-2368801 ACTIVE ER HARD. RESET CB'S TO TEST SATCOM UNIT. NO SATCOM LEGEND INDICATED ON FMC. REPLACED SDU.SDR UALA2011042802068Pressure Switch · faultyENGINE OIL FILTER SENSOR LT. REPLACED THE MAIN ENG OIL FILTER, NO DEBRIS NOTED. REPLACED THE DIFFERENTIAL PRESSURE SWITCH ASSY. RAN ENG PER JRH OIL PRESSURE READINGS NORMAL.SDR UALA2011042802084Lamp · unsecureSEAT 1F AFT EMERGENCY LIGHT INOPERATIVE. SECURED LAMP ASSY.SDR UALA2011042802083Battery Pack · inoperativeDOOR 2 GALLEY COMPLEX EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY SUPPLY M33096.SDR UALA2011042702042Light · inoperativeSEAT 11F FWD EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSY PER MM, CHECKED OKAY.SDR UALA2011042702041Light · inoperativeSEAT 11D AFT EMERGENCY LIGHT INOP. REPLACED LIGHT ASSY PER MM. CHECKED OKAY.SDR UALA2011042702040Light · inoperativeSEAT 11D FWD EMERGENCY LIGHT INOP. REPLACE LIGHT ASSY PER MM, CHECKED OKAY.SDR UALA2011042702037Charger · faultyAPU BATTERY OVHT APU BATTERY OVER TEMPERATURE. STATUS. DEF PER MEL DUE APU BAT NIS FRA. REPLACED BATTERY CHARGER PER MM, GRD CHECK NORMAL.SDR UALA2011042702036Battery · failedAPU BATTERY APU BATTERY FAILURE. DEF APU BAT PER MEL DUE PART NIS FRA. REPLACED BATTERY PER MM.SDR UALA2011042902099Door · unknownDOOR 4R WILL NOT ARM. DOOR 4L OKAY. AT DOOR 4R THE THE RIGHT YELLOW DOOR ARM FLAG NOT IN VIEW. CYCLED DOOR SEVERAL TIMES AND ARMED SLIDE SEVERAL TIMES. OPS CHECKS NORMAL. BOTH YELLOW FLAGS IN VIEW WHEN ARMED.SDR UALA2011042602031Fmu · leakingOIL LOSS & FUEL LEAK NR 2 ENG FMU HAS FUEL LEAK AT WEEP HOLE ON "PF" PORT, FUEL PUMP HAS BOLT THAT WILL NOT TIGHTEN ON COVER PLATE 7:00 POSITION ON PUMP. REPLACED FUEL PUMP PER AMM AND FMU PER AMM. OIL QTY LOW. RT ENG OIL QTY AT 12. ALL CHIP DETECTORS OK, SDR UALA2011042602033Light · inoperativeEMERGENCY LIGHT ON SEAT 21G IS INOP. REPLACED LIGHT ASSY. OPS CHECKS GOOD.SDR UALA2011042602032Lens · missingEMERGENCY EXIT IDENTIFIER LIGHT MISSING LIGHT LENS AT DOOR 2 LEFT FORWARD LIGHT. INSTALLED EMERGENCY EXIT LIGHT LENS. AREA SECURED.SDR UALA2011042602022Terminal · damagedPACK FCV R ONE (BUT NOT BOTH) OF THE TWO RIGHT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. REPAIRED GROUND TERMINAL AT VALVE. FLOW CONTROL VALVE OPERATION IS NOW NORMAL.SDR UALA2011042501977Power Supply · inoperativeOVERHEAD EMERGENCY EXIT LIGHT AT DOOR 2R IS INOP. REPLACED ALL 16 LAMPS, NO HELP. REPLACED EMERGENCY POWER SUPPLY M33097. OPS CHECKS GOOD.SDR UALA2011042501980Connector · damagedENGINE OIL FILTER SENSER LT PRESSURE SWITCH, FOUND PIN 2 OF DS79001 MASHED IN CONNECTOR CAUSING DAMAGE TO PLUG INSULATOR. INSULATOR TORN & CONTACT PUSHED TO SIDE. CONNECTOR P/N CN0966-12S03SN. DOES NOT CROSS. REPLACED CONNECTOR DS79001. REPLACED DELTA PRESDR UALA2011042502004Line · leakingHYDRAULIC LEAK IN NOSE GEAR WHEEL WELL. FOUND STEERING SYSTEM FLEX HOSE FAILED. REPLACED STEERING PRESS LINE PER IPC. ACCOMPLISHED CENTER SYS BLEED MM. ALSO LG CONTROL SYS TEST AC ON GRND. TOPPED 'C' SYS RESERVOIR. FAILED LINE SENT OUT ON RFU 221792 TO SFOEG. SDR UALA2011042502016Controller · faultyOBCR R STATUS MSG. REPLACED RIGHT OVERHEAD BUS CONTROLLER AND TESTED. ALL TESTS PASS.SDR UALA2011042502015Amplifier · faultySATCOM HI GAIN SATCOM HI GAIN IS FAILED. STATUS MSG-2360041 INACTV ER INTER. MAT FAULT HISTORY LAST LEG SHOWED MAINT MSG 23-60061 AND 23-60041. HIGH POWER AMP FOR HIGH GAIN ANT WAS PREVIOUSLY REPLACED. HIGH POWER AMP FOR LOW GAIN ALSO FAULTED BUT NOT REPLASDR UALA2011042501981Elevator · vibrationPILOT REPORTS FUSELAGE SHUDDERS DURING CONTROL COLUMN CHECK WHEN YOKE IS PULLED BACK FULLY AND THEN RETURNED TO NEUTRAL POSITION. ACCOMPLISHED FIM TASK 27- 31 TASK 904, 'NOISE & VIBRATION DURING ON-GRD ELEVATOR CONTROL SURFACE MOVEMENT NO VIBRATION NOTED WHENSDR UALA2011042501994Unknown · odorCREW REPORTED AN ELECTRICAL BURNING ODOR IN AREA OF DOOR 3R. ACFT RETURN TO BLOCKS. ACCURATED INSP OF FUSELAGE DOOR 3 SIDE UPPER PART AND LOWER FLOOR PREVIOUS PANEL ACCESS REMOVED. INSPECTED FOR ELECTRICAL SHORT OR OVERHEATING PARTS BURNED NONE FOUND. OPS SDR UALA2011042501992Light · inoperativeFLIGHT CREW REPORTED EMERGENCY LIGHT AT 1E INOPERATIVE. REPLACED EMERGENCY LIGHT ASSY AT SEAT 1E, OPERATIONS CHECKED OKAY.SDR UALA2011042502001Switch · out of positionEMERENCY LIGHTS ADVISORY ON EICAS. COCKPIT EMER SWX CONFIRMED OFF. FOUND ARMING DEVICE NOT IN THE CORRECT POSITION OF SWITCH IN FLIGHT DECK P5 OVERHEAD PANEL. SECURED ARMING DEVICE OVER TOGGLE SWITCH. EMERGENCY LIGHTS OPS CHECKED OKAY.SDR UALA2011042201963Apu · leakingAPU OIL CONSUMPTION. FOUND OIL LEAK IN TAIL PIPE. DISCONNECTS COMPLETE, NOW READY FOR TRANSFER. CONSUMPTION ABOVE LIMIT. APU REPLACED PER MM. OP'S CHECK NORMAL.SDR UALA2011042501984Idg · failedELECTRICAL GENERATOR SYS RT IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. ELECT GEN OFF RT EICAS MSG AT ENGINE START. RIGHT IDG INOPERATIVE. TRIED SWAPPING GCU 1 AND 2 PESDR UALA2011042502005Module · inoperativeCENTER RT FUEL PUMP INOPERATIVE. 6000 LBS IN CENTER TANK. REPLACED RIGHT CENTER OVERRIDE FUEL PUMP SWITCH MODULE, OPS CHECK OKAY.SDR UALA2011042501991Buss · malfunctionedFLIGHT LOST RIGHT DC BUS.SDR UALA2011042101923Generator · inoperativeAPU GENERATOR INOP. INSTALLED NEW GCU, NO HELP. REPLACED APU GENERATOR PER AMM. OPS NORMAL.SDR UALA2011042101940Transceiver · out of toleranceFWD XCVR IS OUT OF TOLERANCE. TRANSCEIVER FOUND DEFECTIVE. REPLACED TRANSCEIVER. OPS ARE NORMAL.SDR UALA2011042101924Valve · faultyDURING FUELING OPERATION, FOUND FUEL SEEPING FROM LT JETTISON VALVE. VALVE DEF IN CLOSED POS PER MEL. CB COLLARED. NO FUEL NOTED. PER MEL FUEL TANK ENTRY REQUIRED THROUGH ACCESS PNL 543AB. 2-3 SHIFT SLOT FOR TANK ENTRY RQSTD VIA RQSLOT. VALVE AND ACTUATOSDR UALA2011042201954Oxygen Mask · defectiveF/O O2 MASK NEEDS REPLACEMENT. INSTALLED F/O'S OXYGEN MASK ASSY AS PER MM. CREW OP'S CHECK NORMAL.SDR UALA2011042101922Charger · failedBAT CHARGER MAIN BATTERY CHARGER FAILURE. STATUS MSG01- ACTIVE TAXI OUT HARD; MAIN BATTERY IS WEAK. DB- ELMS P310 ELECTRONICS UNIT MSG-2413054 ACTIVE TA HARD. REPLACED MAIN BATTERY AND CHARGER, CHECKS OKAY.SDR UALA2011042101930Cooling Fan · faultyLEFT EQUIPMENT COOLING SUPPLY FAN MSG. LEFT EQUIPMENT FAN INOP. REPLACED LEFT EQUIP COOLING FAN PER AMM.SDR UALA2011042001908Unknown · smokeCREW REPORT: SMOKE AT LL BUNKROOM AREA. SAMC TEXT: CREW REPORTED THAT THERE WAS A BURNING SMELL AND THAT F/A'S SAW SMOKE. SMOKE CREW REST LWR MSG ON EICAS. UPON RETURN TO GATE, MAINTENANCE WENT ON BOARD AND DOWN INTO THE CREW REST AREA, NO EVIDENCE OF SMOSDR UALA2011041901899Scuff Plate · crackedLOUD HIGH PITCH SQUEAL AT DOOR. DISCOVERED DOOR 2L FWD LT SCUFF PLATE LEAKING DURING PRESSURIZATION. FWD LT SCUFF PLATE AT DOOR 2L IS CRACKED AT THE FWD MOUNT SCREW. REMOVED FWD THRESHOLD PLATE. FOUND FWD OB NUT PLATE MISSING AND A BOLT AND NUT INSTALLED MSDR UALA2011042001907Module · faultyAT 10AB, ELECT ODOR PRESENT. TURN OFF IFE POWER SWITCH IN COCKPIT. FIRST TRIED SEAT POWER AT INDIVIDUAL SEATS, NO HELP. SAMC TEXT: IMMEDIATELY PRIOR TO LANDING, CREW SELECTED POWER ON TO RESET SEATS UPRIGHT FOR LANDING, ODOR RETURNED, SECURED SW OFF. MAISDR UALA2011041901894Rotary Actuator · faultyRT LEADING EDGE KRUEGER FLAP JUST INBOARD OF NR 2 ENGINE STUCK PARTIALLY EXTENDED. SUSPECT ROTARY ACTUATOR FAILED PCN 120-9025 (IF REPLACEMENT REQUIRED). RUN SLATS, FOUND RT KRUEGER ROTARY ACT AT FAULT. REMOVED LOWER PNL 611PB FOR ACCESS. REPLACED RT WING SDR UALA2011041901898Heat Shield · damagedFOUND NR 2 ENGINE STRUT FAIRING HEAT SHIELD SMASHED ON INBOARD SIDE. THIRD BACK FROM FRONT. PART NEEDED IS ITEM 265 ON PG 1. IPC REFERENCE IS 54 54 02 007. REMOVED 4 EA HEAT SHIELD SEC. INSTALLED ROBBED PART AND INSTALLED REMOVED HEAT SHIELDS PER MM.SDR UALA2011041801863Smoke Detector · faulty3L LAV SMOKE DETECTOR WAS GOING OFF UNTIL RESET BY FLT ATTENDANT. COMPLIED WITH MEL. SMOKE DETECTOR DISABLED. RMV'D SENSOR ASST 566-0379. REPLACED SMOKE DETECTOR. SMOKE DETECTOR OP CHKS OKAY.SDR UALA2011041801892Wedge · delaminatedNR 3 SLAT WEDGE DELAM NR 3 SLAT WEDGE DELAM AT OUTBOARD END, RPRD PER MM. ACCOMPLISHED REINSPECTION OF REPAIR FOUND AREA OF DELAM APPROX 2 INCH SQUARE. SMC WU MADE.SDR UALA2011041801887Sdu · malfunctionedSATCOM SYS AND HIGH GAIN STATUS MSG. REPLACED SDU PER MM, ALL OPS NORMAL.SDR UALA2011041801862Generator · faultyAPU GEN FALLS OFF LINE WHEN EXTERNAL PWR REMOVED. REPLACED AGCU PER MM, NO HELP. THEN REPLACED APU GEN PER MM. OPS CHKD OKAY.SDR UALA2011041801861Idg · faulty(AFTER ENG START CREW UNABLE TO GET LEFT GEN ON LINE) REPLACED LEFT ENG IDG, LEAK CHECK OKAY AT DRY MOTORING. REPLACED GCU. OPS NORMAL.SDR UALA2011041801856Printer · odorCABIN PRINTER AT DOOR NR 2 BURNING SMELL. CONFIRMED BURNING SMELL COMING OUT FROM INSIDE OFF THE PRINTER. REMOVED AND REPLACED PAC PRINTER RD-FA1161-01 SN ON 08G0002 SN OFF 10G0036. CHECKED WIRE HARNESS BEHIND PRINTER, NO DEFECTS NOTED. NEW PRINTER OPS CHESDR UALA2011041501841Satcom · faultySATVOICE LOST ON ALL TRIP. STATUS SAT HIGH GAIN CYCLES ON AND OFF. REPLACED SATELLITE DATA UNIT M23106 IAW MM AS PER FIM 23-15 TASK FOR MAINT MSG 23-60021. SATCOM BITE AND SYS OPERATIONAL TESTS PASSED.SDR UALA2011041501840Control Valve · faultyPACK FCV-L STATUS MSG. RPL'D LT UPPER FCV, OPS CKS GOOD & TESTS PASSED.
Back to Boeing 777-222