Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010080202776Generator · corrodedAPU GENERATOR HOUSING FWD SECTION CORROSION. REPLACED WITH NEW APU GENERATOR, TESTS OKAY.SDR UALA2010080202765Transceiver · faultedVHF DATALINK EICAS MSG. FOUND DEFECTIVE TRANSCEIVER. REPLACED CTR VHF TRANSCEIVER. OPS NORMAL.SDR UALA2010080202764Sdu · malfunctionedSATCOM MESSAGE HIGH GAIN STATUS MESSAGE DISPLAYED. BREAKERS PULLED. REPLACED SATELLITE DATA UNIT PER MM. SYSTEM TESTS OKAY.SDR UALA2010073002744Light · inoperativeROW 3E AFT EMERGENCY LIGHT INOP. REPLACED EMERGENCY LIGHT. OP CK NORMAL.SDR UALA2010073002743Line · leakingHYD QTY LOW L LT HYD SYS RESERVOIR QUANTITY LOW. QTY .40. FOUND HYD LEAK FROM EDP SUPPLY LINE AT TOP POSITION. DEPRESSURIZED HYD LINE AND RE-TORQUED EDP SUPPLY LINE AND NO LEAK FOUND WITH ENG RUN IAW JRH 2-2-8. FOUND HYD QTY 0.48 ON ARR SERVICED HYD FLUID.SDR UALA2010080202784Power Supply · failedEMERGENCY POWER SUPPLY M33400 DOES NOT KEEP EMER LIGHTS ILLUMINATED AT DOOR 3L. POWER SUPPLY IS NOT SUFFICIENT. REPLACED EMERGENCY POWER SUPPLY, TESTS OKAY.SDR UALA2010080202783Power Supply · faultyEMERGENCY POWER SUPPLY M33096 DOES NOT KEEP EMER LIGHTS ILLUMINATED AT DOOR 2L. POWER SUPPLY IS FAULTY. REPLACED EMERGENCY POWER SUPPLY. TESTS OKAY.SDR UALA2010080202782Power Supply · defectiveEMERGENCY POWER SUPPLY M33099 DOES NOT KEEP EMERGENCY LIGHTS ILLUMINATED AT DOOR 2L. POWER SUPPLY DEFECTIVE. REPLACED EMERGENCY POWER SUPPLY. TESTS OKAY.SDR UALA2010073002742Power Supply · faultyEMERGENCY POWER SUPPLY M33409 DOES NOT KEEP EMERGENCY LIGHTS ILLUMINATED AT DOOR 4R. POWER SUPPLY IS UNRELIABLE. REPLACED POWER SUPPLY. OP ARE NORMAL.SDR UALA2010073002750Actuator · faultyEICAS STATUS MSG L JETTISON NOZZLE VALVE. NEED TO REPLACE LT FUEL JETT NOZZLE VLV ACTUATOR. REPLACED LT FUEL JETT NOZZ VLV ACTUATOR, NO HELP. MSG STILL ACTIVE. REPLACED L JETT NOZZLE VLV MSG 28-11014. REPLACED LT JET VALVE ACTUATOR. OPS NORMAL. CARDS OPSDR UALA2010073002748Transducer · reads lowCREW OXYGEN LOW EICAS O2 PRESS FLUCTUATING FROM 0 TO +1600. CHECKED O2 VALVE IS OPENED AND PRESSURE IS 1750 PSI. INSTALLED NEW TRANSDUCER, READING ARE MATCHING TANK AND FILLER. NO FLUCTUATING.SDR UALA2010073002749Pcu · faultySPOILER FAILURE. FAULT CODE 27-11500 ACCOMPLISHED RESET OF ACE'S FROM LEFT TO CENTER, NO HELP. RE-INSTALLED IN ORIGINAL POSITION. REMOVED AND CLEANED CONNECTOR AT ACTUATOR, NO HELP. PART ON AOG P4967 (B43541-6). STARTED TO REMOVE NR 1 SPOILER ACTUATOR. RSDR UALA2010073002747Charger · failedMAIN BATTERY MAIN BATTERY FAILURE. STATUS MSG01- ACTIVE CRUISE HARD; MAIN BATTERY IS WEAK. MAIN BATTERY CHARGER IAW MM. OPS ARE NORMAL.SDR UALA2010073002746Battery · faultyMAIN BATTERY OVERHEAT, MAIN BATTERY OVER TEMPERATURE. STATUS MSG01- ACTIVE CRUISE HARD; MAIN BATTERY IS OVERHEATED. DB- ELMS P310 ELECTRONICS UNIT MSG02- ACTIVE CRUISE HARD; MAIN BATTERY IS OVERHEATED. REPLACED MAIN BATTERY, ALL FAULTS CLEARED. BATTERY CHECSDR UALA2010072902733Inverter · inoperativeSEAT 2EF, EMERGENCY LIGHT INOP. REPLACED INVERTER ASSY, OP CHECKS GOOD.SDR UALA2010072902732Pitot Line · unknownREPLACE AUX 2 PITOT LINE WHERE THE PERMA SWAGE REPAIR WAS PREVIOUSLY INSTALLED. REPLACED AUX 2 PITOT AND ACCOMPLISHED LEAK TEST, NO LEAKS FOUND.SDR UALA2010072802718Engine · shutdownNR 2 ENG SHUTDOWN, RTFL. REPLACED ENGINE.SDR UALA2010072702698Light · brokenEMERGENCY LIGHTS BROKEN AT MID GALLEY. REPLACED LIGHTS. OP CHECKS GOOD PER MM.SDR UALA2010072702697Light · brokenEMERGENCY LIGHT BROKEN AT MID GALLEY. REPLACED WITH EMERGENCY LIGHT AND TESTS OKAY. THE WORK IS ACP BY AMECO.SDR UALA2010072802720Lens · missingDR 2L AFT EMERGENCY EXIT LIGHT LENS MISSING. LIGHT ASSY AFT DOOR EDGE 2L INOP. OTHER DOOR LIGHTS OPERATE AT 2L, CROSS AISLE LIGHTS OPERATE NORMALLY. FLIGHT DECK EMERGENCY DOME LIGHT OPERATES NORMALLY. REPLACED LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2010072702705Rib · damagedFOUND RIB DAMAGE IN SIDE HYD DOOR AREA. REPAIRED RIB DAMAGE IAW MM.SDR UALA2010072602683Light · crackedTWO (2) EACH EMERGENCY EXIT LIGHTS CRACKED AT NR 4 LT DOOR. REPLACED LIGHTS IAW MM.SDR UALA2010072602682Power Supply · failedEMERGENCY POWER SUPPLY M33094 DOES NOT KEEP EMERGENCY LIGHTS ILLUMINATED AT DOOR 1R. REPLACED POWER SUPPLY IAW MM. OP CHECK GOOD.SDR UALA2010072602661Line · leaking'C' HYD SYS LEAK. LEAK IN LINES ON C-ADP PUMPS. IDENTIFIED LINES ALL ON AOG. 1 STOCKED (Y6258)1 N-S (S2904). INSTALLED BOTH 3'' HYD LINES ON CTR HYD NR 1 ADP ACCOUNT OF HYD LEAK. BOTH LINES TORQUED. NEED TO SVC CTR SYST. HYD FLUID AND THEN LEAK CHECK LINESDR UALA2010072602690Idg · defectiveELEC GEN SYS R IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MSG-2431662 LATCHD ER MODE ON MAT ADVISORY MSG ELEC G EN OFF R FAULT CODE 242 012 42. IDG(R) OUTPUT CUSDR UALA2010072602678Turbine Blades · damagedNR 1 ENG, S/N 222140, DURING ACK BORESCOPE FOUND HPT-1 BLADE DAMAGED BEYOND SERVICEABLE LIMITS. CHANGE ENGINE AS REQUIRED. MATERIAL BREAK THROUGH AND BURN THROUGH INTO INTERNAL CAVITY.SDR UALA2010072302640Light · inoperativeSEAT 1F EEL LIGHT INOP. REPLACED EEL LIGHT.SDR UALA2010072302639Light · missingSEAT 1E AFT EEL LIGHT MISSING. REPLACED LIGHT.SDR UALA2010072302638Idg · faultyELEC GEN DRIVE L LEFT IDG FAULT (LOW INTERNAL OIL PRESSURE). BOTH OCCURRED AT THE SAME TIME DURING ENGINE START. THIS IS A NUISANCE MSG. REPLACED LEFT IDG PER MM. OPS CHECK GOOD.SDR UALA2010072302631Idg · faultedELEC GEN OFF AND DRV DISCONNECT RT MESSAGES. IDG FOUND FAULTY. REPLACED NR 2 ENG IDG, ALL TESTS NORMAL.SDR UALA2010072302627Gcu · faultyLT & RT ENG GEN FAILURE, RTFL. RT GENERATOR TRIPPED OFF LINE AND UNABLE TO RESET. REPLACED GCU(S) AND OPERATIONS CHECK GOOD IAW MM.SDR UALA2010072102609Psu · damagedSEAT ROW 41 ABC OVERHEAD PSU DAMAGED AND O2 MASKS DEPLOYED. INTERIM REPAIR WAS MADE AND PANEL INSTALLED. REPLACED OVERHEAD READING LIGHT ASSY.SDR UALA2010072102613Apu · odorTAXI CREW REPORTS HEAVY- BAD OIL SMELL COMING FROM THE PACKS WHILE OPERATING ON THE APU. APU WORK RECORDS HAVE BEEN REVIEWED BY SHOP INSPECTOR AND THE DISCREPANCY NOTED HERE HAS BEEN CORRECTED. THE SIGN-OFF OF THE ELR WAS INADVERTANTLY MISSED WHEN THE APU WASSDR UALA2010072002605Reservoir · looseDOOR 1L EPAS RESERVOIR PRESS GAUGE IS LOOSE. INSTALLED NEW EPAS RESERVOIR.SDR UALA2010072002604Autothrottle Sys · failedAUTOTHROTTLE DISC AUTOMATIC OR MANUAL DISENGAGEMENT OF AUTOTHROTTLE (A-T) SYS. AUTOTHOTTLE DISCONNECTED DURING ELECTRICAL STORM. ABLE TO RECONNECT LATER. ACCOMPLISHED FIM22-31-937. CKS OK. ACCOMPLISHED CAT III CK. CKS OK.SDR UALA2010072002606Ring · damagedRN 2 ENG. OUTER KEVLAR CONTAINMANT RING DAMAGED AT APPOX. 1 O'CLOCK POS. (UNDER RH FAN COWL). REPAIRED REF MM. ACCOMPLISHED TEMPORARY REPAIR OF OUTER ENVIRONMENTAL LAYER. TEMPORARY 50 HOUR FLYBACK REPAIR. DAMAGE WAS A CRACK AND PARTIAL TEAR APPRX 10 TO 12 INCHSDR UALA2010072302633Modulating Valve · faultyBLEED FAMV R STATUS MSG. FAMV FOUND FAULTY. REPLACED RT FAN AIR MODULATING VALVE IAW MM. ALL OPS NORMAL.SDR UALA2010072002603Lens · crackedEXTERIOR EMERGENCY EXIT LIGHT LENS CRACKED AT DOOR 1 RT. INSTALLED NEW LENS ASSY.SDR UALA2010072002602Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP. AT DOOR 1 RIGHT. RELAMPED.SDR UALA2010072002601Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 3 LT RELAMPED.SDR UALA2010072002600Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHT INOP AT DOOR 2 LT. RELAMPED.SDR UALA2010071902586Charger · failedMAIN BATTERY MAIN BATTERY FAILURE. REPLACED BATTERY CHARGER IAW MM. CHECKED BATTERY CHARGE FINE, NO FAULT FOUND.SDR UALA2010071902585Battery · faultyMAIN BATTERY & MAIN BATTERY CHARGER STATUS MESSAGE. RPLACED MAIN BATTERY. CHECKED BATTERY CHARGE. IT IS FINE, MESSAGE IS GONE.SDR UALA2010071902583Fan · shortedCREW REPORTS EICAS STATUS MSG AFT CARGO HEAT INOP DET FAN 2 FWD. TEST SHOWS SMOKE DETECTOR FAN 2 LWR FWD OPEN OR SHORTED. REPLACED FWD PIT SMOKE DETECTOR, GROUND TEST PASSED MESSAGE CLEARED.SDR UALA2010072002594Transformer · faultyPRIOR TO DEPT STATUS MSG TRU C2 MSG. FOUND TRU C2 NOT CHARGING. REPLACED TRU. PERFORMED OPS CHECK, MSG CLEARED.SDR UALA2010071902568Unknown · odorF/A CONFIRMED BY 2 OMC BURNING RUBBER - ELECTRICAL SMELL NEAR ROW 6 NOW DISSIPATED. ODOR COMES AND GOES. ROW 6AB STATIC IN AUDIO. ACCOMPLISHED SEAT CABLE AND SEB CK 5AB-6AB. NO OBVIOUS ODOR. WIRING TO SEB CHECKS OK. AUDIO SYSTEM OPERATION NORMAL.SDR UALA2010071902584Generator · faultyELEC BACKUP GEN L EICAS. REPLACED BACK UP GENERATOR. RAN ENG AND OPS CKD NORMAL. NO LEAKS FOUND.SDR UALA2010071602555Valve · faultyLEFT PACK WILL NOT SHUT OFF. CHECKED AIR CONDITION MAINT DISPLAY PAGE AND VERIFIED NO CLOSURE ON UPPER FLOW CONTROL VLV WHEN SW'D OFF. RT PACK OPS OK WITH CORRECT INDICATIONS. ITEM ROLLED FORWARD. LEFT UPPER FLOW CONTROL VALVE INOP IN CLOSED POSITION. DUE NO SDR UALA2010071502535Slide · reads lowDOOR 1R SLIDE PRESSURE NEEDLE IN RED 'NO GO' BAND. SLIDE READS LOW. REPLACED ESCAPE SLIDE PACK ASSY.SDR UALA2010071602549Probe · faultedFUEL IMBALANCE EICAS AFTER T/O. FOUND FUEL INDICATOR STUCK APPROX 62,000 LBS IN LT MAIN TANK. ALL FILL VALVE OPS CHECKED OK. SUSPECT LT MAIN TANK SINGLE POINT SENSORS 11 AND 20 ARE BAD. REPLACED PROBES NR11 & 20 IAW MM, OP'S CHECK`S OK.
Back to Boeing 777-222