Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010071302516Battery · failedAPU FAULT - STATUS MSGS NEEDS BATTERY. REPLACED APU BATTERY PER MM. APU BATTERY CHARGE AND VOLTS GOOD.SDR UALA2010071302512Power Supply · faultyCABIN EMERGENCY LIGHT, SECTION FROM CEILING OF 3L MED TO CEILING OF 42AB AND INCLUDING EXIT SIGN 3L MED JUST AFT OF THE DOOR, ARE INOPERATIVE. REPLACED POWER SUPPLY, OPS CHECK GOOD.SDR UALA2010071302500Start Valve · faultyRIGHT ENGINE START VALVE WILL NOT OPEN. ACP LEAK CHECK AND START TEST PER MM. REPLACED RIGHT ENGINE STARTER AIR VALVE. ACCOMPLISHED AIR VALVE TEST PER MM. REPLACED VALVE AND LEAK CHECK.SDR UALA2010071302496Shutoff Valve · faultyON ENG START GOT EICAS ENG AUTO START L&R MESSAGE. APU BLEED STATUS MESSEGE. DEFERED APU BLEED VALVE, MM SG 49-10990 REF FIM. IF NECESSARY WILL REPLACE IGVA. REPLACED APU BLEED SHUTOFF VALVE, VALVE BAD FROM STOCK. IT WOULD NOT CLOSE WHEN BLEED SWITCH SHUTOFF.SDR UALA2010071202487Sliding Window · noisyLOUD SQUEALING NOISE FROM CAPTS SLIDING WINDOW. REPLACED NR 2 SLIDING WINDOW. PRESSURIZED AIRCRAFT NO LEAKS OR DEFECTS NOTED.SDR UALA2010071202484Mount · damagedNR 2 ENG AFT LOWER ENG MOUNT CENTER LINK ASSEMBLY, CENTER BOLT, BUSHING MIGRATING AFT 3-8 INCH. NR 2 ENG AFT LOWER ENGINE MOUNT. SERVICABLE PART INSTALLED.SDR UALA2010071202483Check Valve · malfunctionedFUEL IMBALANCE. INBD CREW SAID IMBALANCE STARTED 6 HR AFTER TAKEOFF, LT TANK FUEL 1.3 LBS MORE THAN RT TANK BY ANOTHER 2 HR, IMBALANCE INCREASED TO 3000 LBS UNTIL CTR TANK FUEL TO ZERO. NO TIME TO CK SCAV SYS & RT SCAVENGE SYS INOP. FLT CREW REPORTED "CTR TANSDR UALA2010071202481Tube · blockedENG NR 1, NR 3 BEARING WEEP TUBE IS BLOCKED. UNABLE TO CLEAR WEEP TUBE. UNABLE TO CLEAR WEEP TUBE. ACCOMPLISHED BOROSCOPE INSPECTION OF HPT FOR PRESENCE OF OIL USING ALTERNATE METHOD. NO OIL WAS FOUND ON HPT HUB. DUE TO AFT LOWER ENGINE MOUNT BUSHING MIGRSDR UALA2010071202461Indicator · faultyRUDDER TRIM SCALE EXTREMELY DIM. REPLACED RUDDER TRIM IND. SYS GROUND CHECKS NORMAL.SDR UALA2010071202463Wire · chafedNR 1 ENG WIRES CHAFED ON J1 CONNECTOR ON FMU. AREA MARKED WITH TAPE. REPAIRED WIRES IAW GNMM. SECURED AND REPOSITIONED WIRE BUNDLE.SDR UALA2010071202462Dump Valve · leakingFUEL DRIPPING FROM LEFT JETTISON VLV NOZZLE AFTER REFUELING. DUE TO RECENT HISTORY, INOPED LEFT JETTISON VLV PER MEL. LEFT VLV CLOSED, C/B`S PULLED-CAPPED. REPLACED LT JETTISON VALVE. OPS CK GOOD.SDR UALA2010071202457Tru · faultyELEC TRU C2 TRANSFORMER RECTIFIER C2 FAILED. STATUS MSG01- NOT ACTIVE CLIMB INTERMITTENT; TRANSFORMER-RECTIFIER UNIT (TRU C2) IS INOPERATIVE. DB- ELMS P310 ELECTRONICS UNIT MSG-2413058 INACTV CL INTER. REPLACED C2 TRU IAW MM. DC-STBY PWR SYS TEST PASSED.SDR UALA2010070902453Charger · faultySTATUS MESSAGE MAIN BATTERY CHARGER APPEARED AFTER GROUND POWER FELL OFF. MAIN BATTERY CHARGER SWAPPED WITH APU BATTERY CHARGER, APU BATTERY CHARGER DEFERRED AS PER MEL. REPLACED APU CHARGER. TEST PASSED, OPS OKAY.SDR UALA2010070802423Connector · inoperativeSEAT 2F AFT EMERGENCY LIGHT INOPERATIVE. REPAIRED CONNECTOR AT LIGHT ASSY, OPS NORMAL.SDR UALA2010070802433Structure · gougedFOUND GOUGE AT STA 1895, STRINGER 39R. DAMAGE IS 4.5 INCHES LONG X .093 IN DEPTH X .625 IN WIDTH. DAMAGE IS OUT OF LIMITS PER SRM. TREATED, PRIMED AND PAINTED AREA. AWAITING EVA FOR DAMAGE LIMITS. REPAIRED IAW EVA NR 73929.SDR UALA2010070802431Pump · malfunctionedFUEL PUMP R AFT RIGHT AFT FUEL PUMP OUTPUT PRESSURE IS LOW. DEACTIVATED RT AFT PUMP. FAULT MESSAGE 28-12013. FOLLOWED FIM28-22 TASK 821. REPLACED RELAY K28242, TRIED SWITCH S10 AND CARDS M24403A5 & M24403A6, NO HELP. NOW POPS AFT PUMP C-B. INSTALLED ORIGINAL SDR ASMF201007003Access Door · damagedDURING TRANSIT CHECK A BIRD STRIKE WAS DETECTED BETWEEN SLAT NR 9 AND 10. MX PERFORMED A BIRD STRIKE INSP IAW 05-51-18 DETECTING DAMAGES IN ANTI ICE RELEASE ACCESS DOORS SLAT. THE RT WING SLAT LEADING EDGE NR 9 WAS REPLACED IAW DWG NR 114W4565 AND INSTALLED FASDR UALA2010070802432Idg · failedELEC GEN DRIVE L EICAS. DISCONNECT LEFT ENG GEN. IDG DISCONNECTED FOR LOW OIL PRESSURE. NEED TO REPLACE THE IDG. REPLACED LEFT IDG. OPERATION CHECKED OKAY.SDR UALA2010070602415Indicator · faultyRUDDER TRIM INDICATOR SHOWS DOUBLE POINTER LEFT OF CENTER. REPLACED RUDDER TRIM INDICATOR AND OPS TESTED OKAY.SDR UALA2010070602396Light · inoperativeAFT EMERGENCY LIGHT ON SEAT 3E IS INOP. REPLACED LIGHT ASSY, OPS CHECK GOOD.SDR UALA2010070602392Compressor · faultyACRID SMELL REPORTED IN AFT GALLEY. ODOR ISOLATED TO H2O COMPRESSOR IN AFT PIT RT SIDEWALL. CB PULLED AND COLLARED PER MEL 3810AT. CONNECTOR REMOVED FROM COMPRESSOR AND CB PULLED ON P320. REPLACED COMPRESSOR IAW AMM.SDR UALA2010070602390Connector · disconnectedONE (1) EACH EEL INOP ON SEAT 3E. FOUND FWD LIGHT DISCONNECTED. SECURED LIGHT CONNECTOR, OP NORMAL.SDR UALA2010070602376Sensor · faultyLOUD PNEUMATIC NOISE RUMBLE IN AREA OF DOOR 3 AFTER STARTER CUT-OUT, APU IN USE. FLT CREW SOP IS TO START BOTH ENGINES AT THE SAME TIME. APPLIED MEL APU PNEUMATICS INOP FOR ENGINE START. REPLACED APU SURGE VALVE AND APU CHECK VALVE AS REQUIRED PER LM. OPERSDR UALA2010070202353Smoke Detector · faultyAFT CARGO F-D INOP, FLIGHT DIVERTED. ALL 3 AFT CARGO COMPARTMENT SMOKE DETECTORS ARE FAULTING, (ZONE 1,2,3). HAS PREVIOUS SAME FAULT. CMC BIT SHOWS MT MSG-26-20022 CARGO SMOKE DET (LOWER AFT) HAS AN INTERNAL FAULT RESETTING CHANNEL 1 & 2 CIRCUIT BREAKERS CLSDR UALA2010070602402Control Panel · failedTHE MCP AIRSPEED INDICATOR, MCP HEADING SELECTOR & ALT SELECT KNOB ARE ALL INOP. REPLACED MODE CONTROL PANEL, OPS CHECK OKAY.SDR UALA2010070202362Pressure Switch · faultyENG OIL FILTER R RIGHT ENGINE PRIMARY OIL FILTER APPROACHES BYPASS (LARGE PRESSURE DIFFERENTIAL ACROSS NORMAL FILTER) WITH ENGINE RUNNING. ACCOMPLISHED FIM 71-05 TASK 835 CHECKED MCDS REPLACED FILTER. REPLACED DIFF PRESS SWITCH. ACCOMPLISHED IDLE RUN, OPS NSDR UALA2010070202361Oxygen Mask · tornCAPT O2 MASK SEAL RIPPED. REPLACED MASK ASSEMBLY. OPS CHECK IS GOOD.SDR UALA2010070102351Skin · scratchedFUSELAGE SCRATCHED AT BS 920 STR 28R. MAJOR REPAIR ACCOMPLISHED: REPAIRED AT C CHECK ON WU K3083E AS PER SRM REPAIR 4. INITIAL HOLES ZERO TIMED. ACP'D CATEGORY B REPAIR PER SRM 53-00-01 REPAIR 4 AT BS 920 BETWEEN S-28R AND S-29R. REMOVED DAMAGE, ZERO TIMEDSDR UALA2010070102340Smoke Detector · faultyFWD CARGO CHANNEL 1 SMOKE DETECTOR FAULT. TRIED RESETTING C/B, NO HELP. ACP'D MAT GROUND TEST FAILS NEEDS SMOKE DET M26060. REPLACED LWR FWD SMOKE DETECTOR PER MM. OPS CHK NORMAL FROM MAT.SDR UALA2010063002323Engine · oil consumptionNR 2 ENG OIL CONSUMPTION. OIL CONSUMPTION INCREASED SUDDENLY. ASAP NEED TO CK ALL 6 MAG CHIP DETECTORS FOR LEAKS & DEBRIS. ACCOMPLISHED CHECKS PER FIM. NO OIL LEAKS FOUND. WILL CONTINUE TO MONITOR.SDR UALA2010063002321Display · odorELECTRICAL ODOR IN CABIN. SEAT 1A VIDEO SCREEN POPPED & WENT BLANK. AN ELECTRICAL ODOR WAS NOTED AFTERWARDS BUT DISSIPATED AFTER VIDEO SYS & BUFFER BOXES SELECTED OFF. POSSIBLE VDB BOX FAILURE. SYSTEM REINSTATED. AFTER 10 MIN SLIGHT ELECT ODOR NOTED FROM SDR UALA2010063002320Battery · failedMAIN BATTERY FAILURE, RTFL. FOUND FAULTY BATTERY & BATTERY CHARGE. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM. OPS ARE NORMAL.SDR UALA2010063002325Light · inoperativeNR 3R DOOR OUTSIDE EMERGENCY LIGHT IS OUT. RELAMPED, OP NORMAL.SDR UALA2010062902317Gearbox · leakingNR 1 ENG HIGH OIL CONSUMPTION. COKING REPORTED ON LEFT OF THE ENG CASING, LOOK FOR OIL LEAKS, LOOSE CONNECTIONS AT FOLLOWING AREAS, CLEAN COKING, REPAIR LEAKS AS NEEDED. PRESSURIZED GEARBOX FOR 40 MIN WITH NO LEAKS. ACP'D 2 IDLE RUNS WITH NO LEAKS. ACP'ED SDR UALA2010062902314Light · brokenEEL LIGHT BROKEN AT 1E AND 3E. LIGHTS ARE BROKEN. REPLACED EEL LIGHT ASSY. OPS NORMAL.SDR UALA2010062902313Pin · pulledSEAT 3E FWD EEL LIGHT INOPERATIVE. FOUND PINS PULLED OUT OF CONNECTOR. RE-INSTALLED PINS, OPS NORMAL.SDR UALA2010062802298Sleeve · delaminatedNR 2 ENG REVERSER INBD SLEEVE LOWER SURFACE HAS APPROX 10 IN X 1 IN WIDE AREA OF DELAMINATION. THE AREA HAS BEEN CLEANED AND TAPED. THE PANEL HAS 3 LAYERS OF TAPE ON IT VERTICALLY AND HORIZONTALLY. THE REV DAMAGE HAS THREE LAYERS OF TAPE ON IT. NR 2 ENG THSDR UALA2010062902316Generator · faultyELEC GEN OFF APU EICAS. TRIED NEW APU GEN CONTROL UNIT, NO HELP. NO VOLTS OR FREQS SHOWS IN ELECTRIC PAGE. REPLACED APU GEN, OPS CHECKS OKAY.SDR UALA2010062802309Multiplexer · faultyAMUX 2 HAS AN INTERNAL FAULT ON QUICK TEST ON CSCP. SYSTEM FOUND FAULTY. REPLACED AMUX 2 PER MM, OPS CHECKS GOOD.SDR UALA2010062802297Light · brokenBROKEN EMERGENCY LIGHT AT SEAT 3E AFT LIGHT. REPLACED AFT EMERGENCY LIGHT ON SEAT 3E, OP CHECKS GOOD.SDR UALA2010062802292Light · crackedFLOOR EMERGENCY LIGHT CRACKED AT GALLEY F2. REPLACED LIGHT ASSYS, OP CK OK.SDR UALA2010062802291Light · crackedFLOOR EMERGENCY LIGHT CRACKED AT M1 GALLEY. REPLACED LIGHT ASSYS, OPS CK OK.SDR UALA2010062802306Converter · failedELECTRICAL BACKUP SYS STATUS MSG. BOTH BACK UP GEN OFF IN FLT. FLT CREW CYCLED BOTH PUSH BUTTON SWS AND BACK UP GENERATORS WORKED FINE AGAIN FOR THE REMAINDER OF THE FLT. CHECKED MAT-SHOWS MTC MSG FOR L AND R BUG 24-45490-NOT ACTIVE. CHECKED BUG OIL-INDICATES SDR UALA2010062802285Clamp · unsecureAPU BLEED AIR CAUSING VIBRATION - NOISE DURING ENGINE STARTS. LOCKED APU BLEED VALVE CLOSED. REMOVED LT ISOLATION VALVE, LOOKED INSIDE DUCT, NO DEBRIS FOUND. RE-INSTALLED VALVE NOTICED WITH APU BLEED ON THERE IS A SMALL CONSTANT VIBRATION FELT IN THE APU BLSDR UALA2010062802295Probe · faultyACFT RTBL WITH CORRELATED TO ENG CONTROL R. REPLACED INLET P2-T2 PROBE. OPS CHECKS OK.SDR UALA2010062502264Processor · faultyFLIGHT MANANAGEMENT COMPUTER LT STATUS MESSAGE DISPLAYED. CPM-ACMF M2 LT AMIS "CONFIGURATION DATA NOT AVAILABLE" IN SYS CONFIG. REPLACED LT CORE PROCESSOR MODULE ACMF MOO2 PER MM, TEST PASSED.SDR UALA2010062502261Solenoid · faultyPRIMARY FLAP-SLAT ADVISORY MSG ON EICAS. SOLENOID FOUND FAULTY. LOW SPEED SOLENOID REPLACED. TEST PASSED.SDR UALA2010062802303Valve · faultyPACK L 1) OVERHEAT AT LT PACK OUTLET OR LT PACK COMPRESSOR OUTLET OR LT PACK FLOW CONTROL VALVES (FCVS) ARE CLOSED DUE TO: FCVS FAILED CLOSED, FCVS LATCHED CLOSED BY CABIN TEMP CONTROLLER (CTC) BECAUSE OF FAULT, OVERHEAT, OR PACK FLOW SENSING FAILURE, OR BOTHSDR UALA2010062802283Eec · malfunctionedENG CONTROL R RT ENG ELEC ENG CONTROL MSG. REPLACED EEC AND TEST IAW MM. RAN ENGINE 2 AT IDLE AFTER EEC REPLACEMENT. GOT CHANNEL A FAULT TCA THERMOCOUPLE OUT OF RANGE REPORTED BY EEC. M73010 ORDERED TO LLCK DROP. INSTALLED NEW TC. TESTS OK.SDR UALA2010062502263Controller · faultyOPBC R OVERHEAD PANEL BUSS CONTROLLER (OPBC) FAULT. STATUS MSG01- ACTIVE CRUISE HARD; OVERHEAD PANEL BUS CONTROLLER (R) HAS NO OUTPUT ON ANY BUS. MSG02- ACTIVE CRUISE HARD; OVERHEAD PANEL BUSS CONTROLLER (R) HAS NO OUTPUT ON ANY BUS. MSG-2348802 ACTIVE ER HAR
Back to Boeing 777-222