Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010050301471Control Valve · leakingSLATS PRIMARY FAIL MESSAGE WHENEVER FLAPS COMMANDED IN NORMAL MODE. BY- 227914 :MAT SHOWS MNT MSG 27-21021 DETECTED BY FSEU-1. ACPD FIM 27-81 TASK 810 THRU E3(D). CHECKED LOW SPEED SOLENOID RESISTANCE REF. WDM 27-81-15 AT SLAT PRIMARY CONTROL VALVE (V27003) COSDR UALA2010050301495Apu · making metalMID BEARING SCAV CHIP DETECTOR HAS LARGE DARK CHUNKS OF PARTICLES ON IT. THIS IS THE APU MID BEARING SCAVENGE CHIP DETECTOR. APU REPLACED PER MM.SDR UALA2010050301484Shutoff Valve · faultySTATUS MSG NACELLE VENT VALVE LT. VALVE FOUND DEFECTIVE. REPLACED NACELLE ZONE VENTILATION SHUTOFF VALVE.SDR UALA2010050301464Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 1 LIGHT IS INOPERATIVE. RELAMPED. CHECKS GOOD.SDR UALA2010050301462Light · inoperativeEMERGENCY LIGHT AT SEAT 48G IS INOPERATIVE. REPLACED EMERGENCY LIGHT. CHECKS GOOD.SDR UALA2010050301461Light · inoperativeEMERGENCY LIGHT AT SEAT 45G IS INOPERATIVE. REPLACED LIGHT ASSY. CHECKS GOOD.SDR UALA2010050301498Structure · separatedACCOUNT RT WING TO BODY PANEL SEPARATED FROM ACFT. MAJOR REPAIR ACCOMPLISHED: EXTRUDED NUTPLATE TEE ANGLE AT STA. 1476 ATTACHING AFT EDGE OF PANEL 198AR AND FWD EDGE OF PANEL 198FR HAS UPPER SECTION BROKEN OFF. EFFECTED REPAIR IAW UA-EVA -73753.SDR UALA2010043001454Control Panel · faultyRIGHT A-T ARM SWITCH HAS FALLEN OFF. PANEL OUT OF TOLERANCE. R & R MODE CONTROL PANEL. OPS GOOD.SDR UALA2010043001455B-Nut · leakingLT PRSOV MESSAGE. FOUND LINE LEAKING AT THE PRSOV WHEN USING PNEUMATIC TESTER. REMOVED LINE AND FOUND THE "B " NUT SEVERELY GALLED AND ALSO THE UNION GOING INTO THE VALVE. MFG NEW LINE AND PRESSURE TESTED IT OK. PRSOV WORKED NORMALLY USING THE PNEUMATIC TESSDR UALA2010042901444Feeder Cable · burnedFOUND GENERATOR FEEDER CABLE BURNED. NEED TO REPLACE CABLE AND IDG, NR 2 ENG IDG AVAIL CABLE NOT AVAIL CHECKING SHOP ALSO NR 1 ENG EGT PROBES CH A SIGNAL OUT PF RANGE, NEED TO REPLACE. RESEARCHING PARTS. REPLACED IDG POWER FEEDER CABLE HARNESS FROM IDG TO TOSDR UALA2010042901443Lamp · inoperative19G EMERGENCY LIGHT IS INOPERATIVE. REPLACED LAMP. TESTS OK.SDR UALA2010042801420Power Supply · faultyEMERGENCY LIGHTS WON'T TEST, ROWS 31 THRU 43. THIS SEAT GROUPS BLOW FUSE IN THE POWER SUPPLY M33401 LOCATED IN DR 3R OVER DOOR PANEL. ISOLATED SEAT ROWS 31 THRU 35 ARE GOOD AND THE PROBLEM IS 36 AND OR BEYOND. THE BAD AND NEW POWER SUPPLIES IN RE OFFICE. PSDR UALA2010042801424Panel · delaminatedLEFT ENG LOWER DRAIN ACCESS PANEL LEFT HINGE SIDE BOTH PANEL CORNER HAVE DELAMINATION, DIMENSION 1 INCH - 5 INCH AND 1 INCH - 6 INCH. FULL CLEANED AND TAPED DELAMINATION PANEL AREA PER EVA. DRAIN ACCESS PANEL LOCKED CLOSED. CARRY FORWARD 2 CYCLES. REPLACEDSDR UALA2010042801423Isolation Valve · lockedBLEED ISLN VALVE RIGHT BLEED ISOLATION VALVE NOT IN COMMANDED POSITION. MESSAGE WAS LATCHED. TRIED SEVERAL TIMES TO UNLATCH, NO HELP. RESEATED CONNECTOR ON VALVE AND MSG CLEARED. MSG RETURNED AFTER SEVERAL MINUTES. VALVE LOCKED IN OPEN POSITION PER MEL RESDR UALA2010042801410Switch · inoperativeSEAT 8F LUMBER CONTROL INOPERATIVE. SEAT IS USEABLE. REPLACED FAULTY SWITCH, OP CHECK GOOD.SDR UALA2010042601381Generator · faultyELEC BACKUP GEN L LEFT BACKUP GENERATOR OFF DUE TO A PROTECTIVE TRIP. REPLACED BACKUP GENERATOR CONVERTOR. DID NOT CORRECT PROBLEM. REPLACED LT BACKUP GENERATOR, ALL OPS NORMAL. SERVICED NR 2 ENG BACKUP GENERATOR OIL PER SERVICE MESSAGE.SDR UALA2010042601389Rod · bentFOUND RT ENG CROSS TIE SUPPORT ASSY ROD BENT, AND BOTH LEGS ATTACH BOLTS SHEARED. REPLACED HOOP TIE SUPPORT ROD AND BOLTS.SDR UALA2010042601383Rfu · malfunctionedLOW SIGNAL FROM SATCOMM RFU ORDERED NEW RFU FROM DEN SATCOMM HAS LOTS OF HISTORY. REPLACED RADIO FREQUENCY UNIT. SYS LOGGED ON OK.SDR UALA2010042701405Thermal Bypass · faultyAPU AUTO SHUTDOWN. MAT SHOWS 49-10260, HIGH OIL TEMP. RE-STARTED WITH SAME RESULTS. REPLACED OIL FILTER, CHANGED OIL IN APU. CHECKED CHIP DETECTORS. LEAK CHECKED OKAY. RAN APU FOR AN HOUR, NO PROBLEMS FOUND, GROUND CHECK NORMAL. PERFORMED PER MM, PROBLESDR UALA2010042601366Smoke Detector · malfunctionedLAV 131 PAX WAS CAUGHT SMOKING AND ALARM DID NOT GO OFF. RESET ALARM. FOUND NO FIRE EVIDENCE. ALARM TESTS OK. NFF.SDR UALA2010042601385Isolation Valve · faultyAPU BLEED ISOLATION VALVE FAILED AT DEPARTURE. REPLACED FAULTY APU SURGE CONTROL VALVE. CKS GOOD, NO MSG DISPLAYED.SDR UALA2010042601368Wire · damagedSEAT 1E AFT EEL LIGHT INOPERATIVE. REPAIRED EEL LIGHT WIRING SEAT 1E. OPS CHECK GOOD.SDR UALA2010042601384Modulating Valve · faultyIN CRUISE FL350 AIR SYNOPTIC SHOWS PRESS TO AIR C2 HYD PUMP. DURING TROUBLESHOOTING FOUND DEFECTIVE VALVE. REPLACE MODULATING VALVE, ALL OPS OK.SDR UALA2010042601360Oven · dirtyOVEN - SMOKING OR SPARKING DR-2 FWD GAL 420. CREW COMMENTS: OVENS R31 AND R32 SMOKING, STOPPED WHEN TURNED OFF. *S/D* CLEANED BURNT FOOD WRAPPING FROM VENT SCREENS, RAN FOR 10 MINUTES, NO BURNING SMELL. OVENS OP NORMAL.SDR UALA2010042201346Idg · failedLEFT GEN FAILURE, FLIGHT DIVERTED. IDG WAS REPLACED AND RUNS GOOD. ALL CHECKS NORMAL. OK FOR SVC.SDR UALA2010042101333Cable · faultyDIFFICULTIES ENCOUNTERED ARMING OR DISARMING DOOR 3L.SDR UALA2010042101330Terminal Block · brokenTERMINAL BLOCK FOR EMERGENCY LIGHTS AT GALLEY AT DOOR 2R BROKEN. REPLACED TERMINAL BLOCK. OPS CHECKED EMERGENCY LIGHTS AT GALLEY. OPS NORMAL.SDR UALA2010042201348Valve · out of toleranceNR 1 ENGINE RT INTERMEDIATE PRESSURE VALVE FLAPPER PLATE WORN BELOW LIMITS. REPLACED NR 1 ENGINE RT IP VALVE. INSTALLED UNIT IS OPERABLE.SDR UALA2010042201347Valve · out of toleranceNR 1 ENGINE LT INTERMEDIATE PRESSURE VALVE FLAPPER PLATE WORN BELOW LIMITS. REPLACED NR 1 ENGINE LT IP VALVE. REPLACEMENT UNIT IS FUNCTIONAL.SDR UALA2010042201338Lamp · inoperativeEXTERIOR EMERGENCY LIGHT JUST AFT OF NR 3 LT ENTRY DOOR IS NOT WORKING. RELAMPED.SDR UALA2010042101335Pump · faultyFUEL IMBALANCE MSG WAS DISPLAYED ON EICAS. APPX 1 HR AFTER DEPARTURE FUEL IMBALANCE MSG WAS DISPLAYED ON EICAS. READINGS WERE L-64.4 CTR-16.3 R-61.1. APPX 20 MIN LATER READINGS WERE L-64.5 CTR-11.1 R-59.9 TOTALIZER READING TO CALCULATED WITHIN 700 LBS. CREW ASDR UALA2010042001321Battery · failedAPU BATTERY, APU BATTERY FAILURE. STATUS BATTERY CHARGER PREVIOUSLY REPLACED. NO HELP. BATTERY DOES NOT HOLD CHARGE, NEEDS RPL, ON ORDER. REPLACED APU BATTERY, OPS NORMAL.SDR UALA2010042001320Charger · failedBATTERY CHARGER APU APU BATTERY CHARGER FAILURE. STATUS MSG01- ACTIVE TAXI OUT MODE DEPENDENT; APU BATTERY IS WEAK. DB- ELMS P310 ELECTRONICS UNIT MSG-2413047 ACTIVE TA MODE. REPLACED APU BATTERY CHARGER.SDR UALA2010042001319Amplifier · faultySAT VOICE LOST SATCOM VOICE SYS. REPLACED SATELLITE DATA UNIT AND HPA-LGA. INSTALLATION TESTS NORMAL. ACCOMPLISHED SATCOM OP CK, OPS NORMAL.SDR UALA2010041901296Window · leakingF/O SLIDING WINDOW SQUEAL, RTFL. HIGH PITCH NOISE EXTREMELY LOUD, CREW UNABLE TO COMMUNICATE. UNABLE TO SILENCE OR REDUCE NOISE BY APPLYING PRESSURE TO WINDOW. IAW CREW VERBAL, NO NOISE UNTIL LEVEL CRUISE AT FL36, WITH 8.6 DIFF PRESS APPROX 1:10 INTO FLT, DSDR UALA2010041901303Actuator · faultyNR 2 ENG REV ACTUATOR IS DEFECTIVE. R & R THE LOWER RT LOCKING ACTUATOR ON THE NR 2 ENGINE. OPS AND LEAK CHECK NORMAL.SDR UALA2010041901299Seal · damagedNR 1 ENG, NR 17 BLADE ROOT, RUBBER FAIRING SEAL DISBONDING. REPLACED FAIRING AND SEAL ASSY.SDR UALA2010041901300Converter · faultyBOTH BACK-UP GEN OFF LINE. RESET AND THEY RESTORED. REPLACED BACKUP CONVERTER M24004. INSTALLED SOFTWARE AND ACCOMPLISHED ENGINE RUN. CKS OK.SDR UALA2010041901289Bolt · missingRT MLG SIDE STRUT ATTACH POINT, WHERE IT ATTACHES TO THE SPINDLE ON THE OUTER CYL, SAFETY BOLTS ARE MISSING CHECKED NUT FOR PROPER TORQUE AND INSTALLED SAFETY BOLTS.SDR UALA2010041901286Connector · dirtySPOILERS FAILURE OF ONE OR MORE SPOILER PAIRS. ADVISORY MSG-2711504 LATCHED DC HARD. CLEANED CONNECTOR AT DM27120 AND D2137 ON LT SPOILER NR 5. GRD TEST PASSED ON THE MAT AND OPS CKD OK.SDR UALA2010041901304Starter · failedNR 1 ENG STARTER FAILED AT START UP. STARTER IS DEFECTIVE. REPLACED NR 1 ENGINE STARTER. OPS ARE NORMAL.SDR UALA2010041901295Controller · faultyBLEED FAMV L LT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED OR LT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS. REPLACED LT ASCPC, TESTS OK. REPLACED FAN AIR MODULATING VALVE. TESTS OKAY.SDR UALA2010041601278Controller · failedBLEED FAMV R RT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED, OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. REPETITIVE WRITEUP MSG-3610532 ACTIVE DC MODE MSG-3610532 ACTIVE DC MODE. VALVE INOP OPEN. MESSAGE 36-10532 (RVDR CIRSDR UALA2010041601273Oven · faulty30 MINUTES AFTER T/O ELECT ODOR IN 1ST CLS GALLEY AND ROW 15. ODOR LASTED ABOUT 3 HOURS AND THEN DISSIPATED. REPLACED 1ST CLASS GALLEY OVEN R11. OPS OK.SDR UALA2010041501269Idg · leakingFOUND OIL LEAK ON TOP SIDE OF IDG AFTER IDLE RUN OF NR 1 ENGINE. POSSIBLE IDG CHG, PART ON HAND. REPLACED NR 1 IDG IAW MM.SDR UALA2010041501268Valve · inoperativeFOUND RT WING FLT CONT HYD SHUT-OFF VALVE INOP. OPENING UP FOR REPLACEMENT. REPLACED VALVE. OPS NORMAL.SDR UALA2010041501266Light · inoperativeEMERGENCY LIGHT IS INOPERATIVE AT SEAT 2E. REPLACED EMERGENCY LIGHT. OPS CHK NORMAL.SDR UALA2010041401256Panel · looseSEAT 2F PANEL NEAR FLOOR WILL NOT CLOSE CAUSING TRIPPING HAZARD. REPLACED VELCRO TAPE, OPS CHECKED GOOD.SDR UALA2010041401261Fitting · damagedFOUND HOOPTIE LT ENG RT REVERSER HALF PIT PIN MISSING FROM TIE ROD TO STRAP. EAR BENT AND CRACKED AT COWL END FROM OPEN AND CLOSING COWL WITHOUT BEING HOOKED UP. REPLACED DAMAGED FAIRING FITTING.SDR UALA2010041401254Battery · faultyWHEN DOOR 3R IS ARMED THE EXIT SIGNS ILLUMINATE AT DOOR 3L-R AND 4L-R. REPLACED BATTERY AND POWER SUPPLY, RESTORED SYS.
Back to Boeing 777-222