SDR UALA2010041301249Lamp · inoperativeEMERGENCY AISLE LIGHTS INOP AT SEATS 1E, 14D AND 22C. RELAMPED 14D AND 22C. SECURED CONNECTOR ON 1E, OPS CHECK NORMAL.SDR UALA2010041301248Battery Pack · inoperativeDOOR 1L EPAS BATTERY IS INOPERATIVE. REPLACED 2 EA, 9V BATTERYS, OPS CHECK OK. INSP EPAS PACK, PACK SECURE ON DOOR 1L, PACK IN ARMED POSITION LIGHT BLINKING REF METHOD NR 4.SDR UALA2010041301240Light · inoperativeONE EMERGENCY LIGHT (AFT) ON SEAT 2H INOP. NEEDS LIGHT STRIP. REPLACED EMERGENCY LIGHT.SDR ASMF201004001Blades · damagedDURING A BORESCOPE INSP OF THE HPC 1, 4 AND 9 STAGES BLADES OF THE RT ENGINE WAS DETECTED. 1 BLADE OF THE HPC 1ST STAGE WITH L/E TIP CURLED 90 DEGREES OUT OF LIMITS IAW 72-00-00, PARA 5H (L) (7), PAGE 625; WITH DIMENSIONS OF 3.5 INCHES LENGTH AND 1.25 INCHES WSDR UALA2010041201237Panel · delaminatedFOUND DELAMINATION AT PANEL 415MB AND LOCATED AT LT ENG REV LATCH ACCESS DOOR. REPLACED CTR T-R LATCH ACCESS PANEL. CHK OK.SDR UALA2010041201231Lamp · inoperativeEMERGENCY LIGHT INOP ON SEAT 3F FWD. RELAMPED LIGHT ASSY. CHECKED NORMAL ON GROUND.SDR UALA2010041201217Shutoff Valve · faultyBLEED HPSOV L LT ENGINE BLEED HIGH PRESSURE SHUTOFF VALVE (HPSOV) FAILED OPEN OR CLOSED, OR LT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. DUE TO FLIGHT CREWS REPORTING 'BLEED PRSOV L' STATUS MESSAGE WITH NUMEROUS COMPONENTS PREVIOUSLY REPLACED, ACP PNESDR UALA2010041301250Generator · faultyLT ENGINE BACKUP GENERATOR FILTER BLOCKED MESSAGE ON MAINT PAGE. DPI POPPED, ALSO LEAKING OIL BY HSG. REPLACED IAW AMM. RAN ENGINES, BUG HELD LOADS, RESERVICED. BUG CHECKED NORMAL.SDR UALA2010041201203Controller · faultyFOUND ONE OF THE SOLENOID ON THE HPFAC SHORTING. REPLACED HPFAC. NEED ENG AIR SUPPLY OPS TEST. ACCOMPLISHED ENG AIR SUPPLY OPS TEST, PARAMETERS ALL NORMAL. NO MESSAGES.SDR UALA2010041201226Socket · meltedBUSINESS CLASS GALLEY OVHD LIGHTING POSSIBLE OVERHEAT- SHUTOFF : FOUND BURNING SIGNS AT LIGHT ASSY ABOVE WARMING OVEN W32. BULB AND SOCKET MELTED. INSPECTED AREA, NO ABNORMALIES NOTED OUTSIDE OF LIGHT ASSY. DISCONNECTED ASSY AND TURNED ON CEILING LIGHTS, OPSDR UALA2010041201216Bulb · meltedBUSINESS CLASS GALLEY OVERHEAD LIGHTING POSSIBLE OVERHEAT-SHUTOFF. FOUND BURNING SIGNS AT LIGHT ASSY ABOVE WARMING OVEN W32. BULB AND SOCKET MELTED. INSPECTED AREA, NO ABNORMALITIES NOTED OUTSIDE OF LIGHT ASSY. DISCONNECTED ASSY AND TURN ON CEILING LIGHTS,SDR UALA2010041201205Control Valve · faultyAIR COND PACK FAILURE, FLIGHT DIVERTED. REPLACED LOWER FLOW CONTROL VALVE, NO HELP. REPLACED CABIN TEMP CONTROLLER, FIXED PROBLEM. UPPER AND LOWER FLOW CONT INDICATION ALSO WORKS.SDR UALA2010041201199Light · inoperative1 EA EMERGENCY EXIT LIGHT ON SEAT 3E IS INOPERATIVE. REPLACED LIGHT ASSY, LIGHT OPS CHECKS GOOD.SDR UALA2010041201233Battery · reads lowAPU BATTERY LOW VOLTAGE MSG DISPLAYED. BATTERY FOUND DEFECTIVE. REPLACED APU BATTERY. OPS ARE NORMAL.SDR UALA2010041201200Light · inoperativeEMERGENCY EXIT LIGHT ON SEAT 3F IS INOPERATIVE. REPLACED LIGHT ASSY, LIGHT OPS CHECKS GOOD.SDR UALA2010041201198Power Supply · inoperativeEMERGENCY LIGHTS AFT COACH INOP BOTH SIDES. REPLACED POWER SUPPLY AT DOOR 3 RT, OPS CHECK NORMAL.SDR UALA2010041201197Processor · malfunctionedFUEL DISAGREE, RTFL. PROCESSOR FOUND FAULTY. REPLACED FUEL PROCESSOR, ALL TEST PASSED.SDR UALA2010041201196Controller · faultySTATUS MSG 'BLEED PRSOV L' DISPLAYED ON ARRIVAL. REPLACED LT ASCPC. SYS OPERATION NORMAL.SDR UALA2010040901191Controller · faultyBLEED OFF ENG L EICAS MSG. CYCLED BLEED SWITCH, NO HELP. ACFT RTBL DUE TO HISTORY. PRSOV LOCKED IN CLOSED POSITION PER MEL. REPLACED PRSOVC, RAN ENGINE PER JRH, CHECKED NORMAL.SDR UALA2010040901192Shutoff Valve · faultyRT DUCT PRESS OSCILLATING BETWEEN 38-65 PSI. NO TIME TO TROUBLESHOOT PROBLEM, HAS HISTORY INOP PRSOV CLOSED. REPLACED HPSOV AND CONTROLLER.SDR UALA2010040901190Circuit Card · defectiveLT HYD MODULE FAILED. CARD FOUND FAULTY. REPLACED HYDIM CL INTER-FACE CARD. TESTED OKAY PER MM.SDR UALA2010040901187Shutoff Valve · failedBLEED PRSOV R RT ENGINE BLEED PRESSURE REGULATING SHUTOFF VALVE (PRSOV) FAILED OPEN OR CLOSED OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; PRESS REGULATING AND SOV (RT) FAILED CLOSED. DB- AIR SUPPLY & CABSDR UALA2010040801182Engine · failedLEFT ENG FAILURE AT TAKE OFF. OPS CHECKS ON ENG DONE IAW MM. REPLACED NR1 ENGINE.SDR UALA2010040801181Ram Air Turb · faultyRAT WON'T DEPLOY.SDR UALA2010040601150Hydraulic System · leakingHYD FLUID LOSS FROM LT SYS. QTY WENT DOWN TO APPROX .65 WITHIN FIRST 4 HRS OF FLIGHT. CREW SELECTED LT ENG AND ELECT HYD PUMPS TO OFF AS A PRECAUTION TO CONSERVE FLUID FOR DESCENT, HYD FLUID LOSS STOPPED WITH PUMPS TURNED OFF. NEVER HAD LOW PRESS OR OVHT INDSDR UALA2010040601149Video Display · faultySEAT 11D, E & F THE VIDEO & AUDIO INOP. CREW SMELLED SMOKE IN THAT AREA BEFORE TAKEOFF. MAINT CKD BUT DIDN'T FIND OR SMELL ANYTHING. FOUND VDB ITSELF SMELLED A LITTLE, REPLACED VDB AND VIDEO WORKS BACK TO NORMAL. SMELL DID NOT OCCUR WHILE ON GROUND.SDR UALA2010040701159Circuit Card · failedELMS P310 CHANNEL CARD FAILED. REPLACED A3 CPU CARD IN ELMS P310 PANEL. CORRECTION: A3 - L ARINC 629 CARD WAS REPLACED IN P310 ELMS PANEL.SDR UALA2010040601154Shutoff Valve · faultySTATUS MESSAGE ON EICAS, BLEED PRSOV L. PRSOV LEFT NR 1 INOP IN THE CLOSE POSITION. PER MEL 36040 ENGINE IDLE SELECTION SYSTEM IS CONSIDERED INOP. INSTALLED NEW PRSOV AND PRSOVC PER AMM AND PERFORMED TEST. SYSTEM OPERATES NORMALLY.SDR UALA2010040601155Battery · failedBATT CHARGER APU, APU BATTERY CHARGER FAILURE. REPLACED BATTERY AND BATTERY CHARGER, GROUND CHECK NORMAL.SDR UALA2010040501119Retainer · brokenDOOR 1R WILL NOT OPEN OR CLOSE USING OUTSIDE HANDLE. DOOR WILL DISARM WHEN ARMED AND HANDLE PULLED FROM OUTSIDE. SUPPLEMENTAL DATA UPDATE REMOVED EXTERIOR HANDLE. FOUND BROKEN RETAINER. PARTS IN FWD GALLEY. FOUND RETAINER RING MISSING. REPLACED RETAINER. OPS CSDR UALA2010040501117Lens · damagedFWD EMERGENCY LIGHT ON SEAT 14F HAS A DAMAGED LENS. REPLACED EMERGENCY LIGHT ASSY, VERIFIED LIGHT OPS NORMAL AFTER REPLACEMENT.SDR UALA2010040501112Smoke Detector · no testSMOKE DETECTOR IN LAV 1F-1C (1L-CTR) IS FAILING SMOKE DETECTOR TEST DURING ALL TEST. SUPPLEMENTAL DATA UPDATE INSTALLED NEW DETECTOR. DETECTOR NOW OPS CHECKS GOODSDR UALA2010040201101Controller · faultyRT ECONOMY COOLING VALVE INOPERATIVE. PACK MODE R DISPLAYED AGAIN AFTER ENGINE START. MSG NR 21-23402. REPLACED CABIN TEMP CONTROLLER AND INSTALLED SOFTWARE. GRD TESTED, PASSED.SDR UALA2010040201097Lamp · unsecureEMERGENCY LIGHT COVER IS FALLING OFF NEAR SEAT 1E. RESECURED LAMP ASSY TO SEAT AND TESTED OKAY PER MM.SDR UALA2010033101088O-Ring · damagedOIL LEAK ON NR 1 ENGINE LT SIDE AT AFT SIDE OF FUEL OIL COOLER. FOUND NR 2 BEARING LAST CHANCE FILTER HOUSING LEAKING AT PARTING SURFACE. REPLACED 'O' RING FOR FILTER. LEAK CHECK OFSDR UALA2010033001064Light · inoperativeFWD EMERGENCY LIGHT AT SEAT 11F IS INOP. REPLACED LAMP.SDR UALA2010033001063Light · inoperativeEMERGENCY LIGHT AT SEAT 41G IS INOP. REPLACED LIGHT ASSY.SDR UALA2010033001062Light · inoperativeEMERGENCY LIGHT AT SEAT 39C IS INOPERATIVE. REPLACED LIGHT ASSY.SDR UALA2010032901042Fuel/Oil Cooler · leakingNR 2 ENG OIL CONS EXCEEDS LIMIT. PER SAMC SUSPECT FUEL OIL HEAT EXCHANGE INTERNAL LEAK. REMOVED FUEL OIL HEAT EXCH. REPLACED FUEL OIL COOLER, PERFORMED HI POWER RUN PER MM. ALL OPS AND IND NORMAL, NO FAULTS OR LEAKS NOTED.SDR UALA2010032901029Actuator · faultyAPU DOOR APU INLET DOOR IS NOT IN COMMANDED POSITION. STATUS REPLACED APU CONTROLLER. FOUND MAINT MESSAGES 149-18801, 49-14120, 49 -14110, 49-17001, 49-12990 AND FAULT CODE 49600100 ON SEVERAL LEGS, APU INLET DOOR INDICATIONS NORMAL AS SHOWN ON EICAS MAINT SDR UALA2010033001058Pin · bentPACK FCV L DISPLAYED ON STATUS PAGE RESET AND RE-APPEARS. DEF PER MEL DUE TIME AND NO PART AVAIL AT FRA. REPLACED UPPER LEFT PACK FCV. RAN TEST FAULTED L ECONO COOLING VLV CNTL FOUND BREAKER H23 POPPED ON P110 PANEL. (2) ALREADY REPLACED RELAY K21009 AND BRSDR UALA2010032601026Packing · leakingFUEL LEAKING FROM WING PANEL 552HB. FOUND FUEL LEAKING FROM LT MAIN FUEL JET PUMP AROUND MATING SURFACE. RECOMMEND REPLACING PACKINGS. REPLACED PACKINGS, LEAK CHECK FAILED. RPLC'D SEALS. FUELED & STILL LEAKING. ORDERING PUMP AVAIL IN THE SYS. PUMP INSTLD. FUESDR UALA2010032601021Line · leakingEVIDENCE OF HYD LEAK IN LT WHEEL WELL. FLUID HAS SOAKED BELLY PANEL AFT OF GEAR. FOUND HYD LEAK IN LT WHEEL WELL AFT BULKHEAD. WITH ENG RUN LEAKING 20DPM AT LINE TO TEE. REPLACED HYD LINE 180, STILL LEAKING FROM TEE. REPLACED TEE ITEM 300 STILL LEAKING ASDR UALA2010032601013Light · inoperativeSEAT 1E FWD EMERGENCY LIGHT INOPERATIVE. REPLACED SEAT 1E FWD EMERGENCY LIGHT ASSY. EMERGENCY LIGHT OPS CHECK GOOD.SDR UALA2010032601012Light · inoperativeF-C PAX SEAT 3F FWD EMERGENCY LIGHT ASSY INOPERATIVE. REPLACED PAX SEAT EMERGENCY LIGHT ASSY AND OPS CKD ALL GOOD.SDR UALA2010032400999Generator · faulty"ELEC BACKUP GEN R" MSG. BUG IS FAULTY. RT BUG REPLACED IAW MM. LEAK AND OPS CHECK OK.SDR UALA2010032300996Transceiver · defectiveLEFT HF WILL NOT TUNE. TRANSCEIVER DEFECTIVE. INSTALLED SERVICEABLE TRANSCEIVER IAW MM. OPS CHECKED IAW SAME. SYS PASSES NOTED CHECKS. RETURNED ACFT BACK TO NORMAL. OK FOR SERVICE.SDR UALA2010032300987Heater · faultyWINDOW HEAT R FWD FAILURE OF RT NR 1 WINDSHIELD HEATING CIRCUIT (LOSS OF WINDOW COATING, WIRING, OR THE INDIVIDUAL WHCU CIRCUIT FOR THAT WINDOW). STATUS MSG-3021032 INACTV CL INTER 1R FWD WINDOW REPLACED. WINDSHIELD WIPER SYSTEM OPS TEST NORMAL.SDR UALA2010032300960Valve · leakingFUEL DRIPPING FROM APU FUEL VENT. FUEL LEAKING FROM FWD DRAIN LINE 50-60 DROPS PER MIN. NO LEAK WITH APU OFF. SUSPECT SURGE CONTROL VALVE ACTUATOR. THE FUEL PUMP SHAFT SEAL, IGV ACTR & SCV HAVE TELL TALE WITNESS DRAINS TO EASILY IDENTIFY A FAULTY UNIT. EACSDR UALA2010032300991Connector · unsecure2E EMERGENCY LIGHT INOP. SECURED CONNECTOR ON LIGHT ASSY. LIGHT OP CHECKS GOOD.
Back to Boeing 777-222