Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009110403423Gusset · faultyNR 2 ENG OIL CONSUMPTION EXCEEDS LIMIT. REPLACED NR 3 BEARING BREATHER GUSSETS. ALL OPS NORMAL. CLEAN COKE RESIDUE AROUND NR 3 BREATHER AND ACP ENGINE HIGH POWER RUN PER JRH. NO LEAKS FOUND.SDR UALA2009110403424Turbine Blades · burnedNR 1 ENG FAILED STG 1 HPT BOROSCOPE. EXCESSIVE BURN THROUGH DAMAGE TO HPT STG 1 BLADE. BLADE BURN THROUGH JUST AFT OF LEADING EDGE. COMPLETELY THROUGH BLADE ALSO THE INNER AFT SIDE OF REMAINING LEADING EDGE HAS A CRACK AROUND MID SPAN. REPLACED ENGINE. NESDR UALA2009110403422Antenna · faultySATCOM HI GAIN IS FAILED. AWAITING ANTENNAS AND GASKETS. HARD FAULT MESSAGE TOP-PORT HGA FAIL. REPLACED SPLITTER, NO HELP. REPLACED LEFT SMHGA ANTENNA, SATCOM SYSTEM TEST OKAY.SDR UALA2009110403412Window · scratchedNR 2L WINDOW SCRATCHES OUT OF LIMITS. FOUND DEPTH OF SCRATCH AT .0061 INCH. REPLACED WINDOW.SDR UALA2009103003393Light · missingSEAT 2E SEAT MOUNTED EMER LIGHT MISSING. REPLACED EMERGENCY LIGHT. OP CHECKED OKAY.SDR UALA2009103003397Blades · damaged12 STG BLADES HAVE DAMAGE AT ROOT. NR1 ENG BOROSCOPE FOR PARAMETER SHIFT. STG 7 HAS TIP TORN OFF THRU AREA F AND NUMEROUS BLADES DAMAGED AT ALL STAGES. REPLACED ENG NR1.SDR UALA2009102803376Fan · odorCREW REPORT ODOR IN AND AROUND 2L AND VIDEO CABIN AREA. OPENED CABIN CEILING AT 2R&2L, RUN APU AND BOTH ENG WITH PACKS ON & GALLEY LOADED WITH OVEN, C-F MAKER, CHILLER, CABIN HEAT UP TO 85 DEGREE, CAP & F/O SHOULDER HEAT & FLIGHT DECK REST AREA HEATER. COULDSDR UALA2009102803363Light · damagedSEAT 1E FORWARD EEL LIGHT BROKEN AND LENS MISSING. REPLACED LIGHT CHECKS OKAY.SDR UALA2009102703355Amplifier · failedSATCOM FAILURE. SATCOM IS MALFUNCTIONING. REPLACED HIGH POWER AMPLIFIER. REPLACED SATELLITE. REPLACE BEAM STEERING UNIT ON LEFT SIDE. ALL OPS OKAY.SDR UALA2009102603330Wire · exposedEMERGENCY LIGHT MOUNTED ON SIDE OF SEATS 1E & 3E HAVE EXPOSED WIRES. INSTALLED SERVICEABLE EMERGENCY LIGHTS. RETURNED A/C BACK TO NORMAL. OPS CKD, SYS OPS NORM. OK FOR SVCSDR UALA2009102603325Battery · dischargedTHE 2R FLASHLIGHT NOT BLINKING. REPLACED FLASHLIGHT BATTERY.SDR UALA2009102303320Transceiver · malfunctionedF/O AUDIO WILL NOT RECEIVE, TRANSMITS OKAY. REPLACED R VHF TRANSCEIVER AND R RADIO TUNING PANEL. OPS CHECK OF VHF LT AND RT SYSTEMS CHECKED GOOD.SDR UALA2009102203302Actuator · leakingNR 1 ENG LEAK CHECK FOUND STATOR VANE ACTUATOR LEAKING FUEL. REMOVING OLD ACTUATOR, WORKING AT HANGAR. REPLACED STATOR VANE ACTUATOR. NO LEAKS NOTED DURING 5 MINUTE IDLE. ACCMP'D ACCEL-DECEL TESTS NR 3, 4 & 6. OP CHECKS GOOD.SDR UALA2009102203298Wire Harness · faultySPOILERS EICAS. FOUND WIRE HARNESS THAT CONNECTS TO NR 4 SPOILER PCU BURNT. NEW NR 4 SPOILER ACTUATOR INSTALLED. NR 4 SPOILER TROUBLE-WIRE HARNESS DISCONNECTED AT BOTH ENDS FOR REPLACEMENT. ALSO CLAMPS AND OLD HARNESS LEFT LOOSELY IN PLACE FOR NEW INSTALLASDR UALA2009102303314Pump · damagedRIGHT ELECT HYD PUMP WAS RUN WITH RIGHT HYD SYSTEM EMPTY. REPLACED PUMP. ALL OPS NORMAL.SDR UALA2009102203290Lens · brokenMID GALLEY, CENTER CEILING PANEL EMERGENCY LIGHT LENS ASSY FOUND BROKEN, TAPED IN PLACE, NOT DOCUMENTED. SECURED LENS IN PLACE WITH TAPE, LENS AND LIGHT ARE SECURED, LIGHT NOT OBSTRUCTED.SDR UALA2009102103283Pump · leakingCREW RECEIVED HYD QTY LOW R INDICATION. NEED TO REPLACE RT ENG EDP. REPLACED RIGHT EDP. ACCMP'D LEAK CHECK, CHECK OKAY. NEED TO REPLACE SWITCH AND O-RING SWITCH. REPLACED NORMAL BRAKE SOURCE PRESS SWITCH. ALL OPS NORMAL.SDR UALA2009102103280Fuel Control · malfunctionedAPU WILL NOT START. COUT RESISTANCE CHK OF FUEL CLUSTER UNIT PIN 9 AND 10 FUEL CLUSTER RECEPTACLE FOUND MORE THAN 1000 OHMS (32000 OHMS) SUSPECT FUEL CLUSTER. APU FUEL CLUSTER REPLACED. ACCOMPLISHED SUCCESSFUL START AT ALTITUDE. CREW COMMENTS: APU STARTED NOSDR UALA2009102003270Control System · malfunctionedAPU DOOR APU INLET DOOR IS NOT IN COMMANDED POSITION. STATUS CREW COMMENTS: ON INTERMITTENTLY MSG-4917001 ACTIVE ES MODE, MSG-4914110 ACTIVE ES MODE. POSSIBLE CAUSES INCLUDE RELAY (APU INLET DOOR CONTROL) IN P310, K49001 (P310), I-O CARD (6) IN P310,M24406ASDR UALA2009102003269Connector · defectiveHYD PUMP PRI C1 LOW CENTER HYDRAULIC PRIMARY PUMP NR 1 PRESSURE WHEN COMMANDED ON, OR CENTER PRIMARY PUMP NR 1 OVERHEAT. STATUS MSG-2912015 LATCHD ER MODE. REPLACED CONNECTOR PER BOEING STANDARD ELECTRICAL PRACTICES. RE-ACTIVATED PUMP. HYD C1 PUMP WORKS NOSDR UALA2009102103284Pcu · malfunctionedNR 3 SPOILER MESSAGES. REPLACED NR 3 SPOILER PCU. GROUND CHECKS GOOD MAT TEST PASSED NO FAULTS.SDR UALA2009102003264Plate · damagedEMERGENCY EXIT SIGN AT DOOR 1R HAS LENS TAPED ON. FOUND PLASTIC MOUNT THAT ATTACHES TO DOOR FRAME BROKEN LENS IS OK. NEED NEW MOUNTING PLATE. EXIT SIGN IS LOCATED JUST AFT OF DOOR ABOUT 36 INCHES UP FROM FLOOR. REPLACED LIGHT ASSY - TESTS OKAY.SDR UALA2009101903260Battery · failedON ARRIVAL EICAS STS MSG - FLIGHT CONTROL SYS - DISPLAYED. ON MAT FOLLOWING MAINT MSG SHOWN. 1) 24-50242, FC BATTERY-R- VOLT LOW, 2) 27-10510,SPOILER PCU -11- & 27-10503 SPOILER PCU-4-DOES NOT FOLLOW COMMAND. UNABLE TO GET PROBLEM SOLVED THRU MAT TESTER A-C SDR UALA2009101903257Idg · failedELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). ADVISORY FOUND RT IDG OVERFILLED. SERVICED CORRECTLY. RECONNECTED IDG. RAN ENGINE. IDG INOP. REPLACED RIGHT IDG. SECURED ALL ELECTRICAL OIL CONNECTIONS AND SAFTIED QUAD RING AND OPS CKED. OP CSDR UALA2009101903258Socket · burnedRIGHT AFT LAV LIGHT HOT/SMOKING. FOUND MIRROR LIGHT SOCKET BURNED OUT IN 4R LAV, PULLED C/B J7 ON P320 FOR LAV LIGHT LEFT AND LAV 1L FWD CTR, 2L, 3L FWD AND 4R AVAILABLE DOME LIGHT ONLY. CONFIRMED NO POWER FOR AFFECTED LAVATORY & COVERED INSULATION TAPE OVERSDR UALA2009101603244Duct · dirtySMOKE IN COCKPIT AND BUNKIE SMOKE ALARMS ACTIVATED WHEN AT FL320 AND LEFT PACK OFF AND TEMP CONTROLS TO FULL WARM. COULD NOT DUPLICATE WHEN AT 10000FT. WHEN REPEATING TESTS WITH RIGHT PACK OFF, THERE IS MUCH LESS SMOKE AND BUNKIE SMOKE ALARM DOES NOT ACTIVASDR UALA2009101503241Light · inoperativeDOOR 4R EXTERIOR MOUNTED EEL INOP. RELAMPED, OP NORMAL.SDR UALA2009101503238Charger · inoperativeDOOR 3R EXTERIOR MOUNTED EEL INOPERATIVE. REPLACED CHARGER AT DOOR 3R, TESTS OKAY.SDR UALA2009101503237Charger · inoperativeALL SEAT MOUNTED EEL FROM SEAT 31 TO 43 INOP BOTH AISLE. REPLACED CHARGER AT DOOR 3R, TESTS OKAY.SDR UALA2009101403225Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 3 RIGHT INOP. RELAMPED EMERGENCY LIGHT AT DOOR 3R. OP CHECKS GOOD.SDR UALA2009101403221Hinge · brokenROW 42 OXYGEN MASKS FELL. OXYGEN MODULE HINGES ARE BROKEN, STOW BIN MAY HAVE CONTACTED OXYGEN DOOR. OXYGEN MASK-GEN MODULE WILL NEED REPLACED. ROW 41 IS TAPED AND INOP, ROW 42 IS SERVICEABLE. REPLACED WITH NEW 02 BOX ASSY. CHECKS OKAY.SDR UALA2009101303219Control Unit · malfunctionedCENTER LEFT REFUELING VALVE INOP. REPLACED LEFT CENTER FUELING VALVE CONTROL UNIT. OPERATIONAL CHECK NORMAL.SDR UALA2009101203202Heater · odorLEFT PACK RUNNING OIL ODOR IN COCKPIT. ACP'D POWER RUN OF BOTH ENGINES, OPERATED PACKS TO ISOLATE SOURCE OF ODOR. FOUND ODOR PRESENT ONLY WHEN LEFT TRIM AIR SELECTED ON AND HEAT DEMANDED. CONDITION EXISTS REGARDLESS OF AIR SOURCE. ODOR NOT PRESENT WITH RIGSDR UALA2009101203192Holder · burnedLAV 3R AFT MIRROR LIGHT INOPERATIVE. FOUND FWD HOLDER BURNT. REQUIRES HOLDER. DISCONNECTED AND SAFETIED BALLAST CONNECTOR. DOME LIGHT OPS NORMAL.SDR UALA2009101203203Display · malfunctionedUPPER EICAS WENT BLANK PRIOR DEPARTURE. MAT INTERROGATED SHOWS CPM -GG MODULE M10 AND M11 INTERFACE TO DU INOP. AIMS RESET DONE TO NO AVAIL. MESSAGES CLEARED BUT UPPER EICAS STILL BLANK. UPP AND LWR DISPLAY UNITS SWAPPED AND AIMS MODULES RESET DONE AGAIN. SDR UALA2009100803165Freq Unit · malfunctionedDATA LINK LOST NO DATA LINKS ESTABLISHED (HF, VHF, SATCOM MODE S DATA LINKS LOST) ADVISORY. REPLACED RADIO FREQ UNIT AND SYSTEM, OPS NORMAL.SDR UALA2009100803158Bleed Valve · malfunctionedSTATUS MESSAGE BLEED VALVE APU DISPLAYED DURING CRUISE. REPLACED APU BLEED VALVE AND RESET ASPL CONTROLLER, MSG CLEARED.SDR UALA2009100703149Battery · dischargedDOOR THREE LEFT EXTERIOR EMERGENCY LIGHT INOP. REPLACED BATTERY POWER ASSY ABOVE DOOR 3L. OPS CHECKED GOOD.SDR UALA2009100703150Control Valve · faultyLEFT PACK SLOW TO SHUTDOWN AND GENERATES A PACK FCV L STATUS MSG. REPLACED UPPER FLOW CONTROL VALVE. OP CHECKS NORMAL.SDR UALA2009100603134Fuse · brokenCTR HYD SYS FLUID LOSS, RTFL. FOUND HYD FUSE BROKEN. REPLACED HYD FUSE AND SYSTEM WORKS NORMAL.SDR UALA2009100603132Lens · brokenDOOR 4L FWD EXIT LIGHT ASSY BROKEN LENS WON'T STAY ON LIGHT WORKS. REPLACED FWD EXIT LIGHT ASSY AT DOOR 4L, OP CHECKS GOOD.SDR UALA2009100503125Isolation Valve · malfunctionedBLEED AIR ISOLATION VALVE STATUS MESSAGE DISPLAYED, PER CREW. REPLACED RIGHT BLEED AIR ISOLATION VALVE. TESTED AND OP CHECKS GOOD. DURING ACCOMPLISHMENT OF PROCEDURES PER MEL 3612B (RECYCLED) VALVE AND DEVICE RETURNED TO NORMAL OPERATION.SDR UALA2009100603145Shutoff Valve · failedBLEED PRSOV R RIGHT ENGINE BLEED PRESSURE REGULATING SHUT OFF VALVE (PRSOV) FAILED OPEN OR CLOSED OR RIGHT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. REPLACED NR 2 ENG PRSOV AND PRSOVC. BLEED FAILED DURING HIGH POWER RUN. ACP WRENCH CHECKED ALL PRSOVSDR UALA2009100603144Cable · out of toleranceCAPT'S RUDDER PEDALS WON'T STAY IN POSITION SELECTED, PEDALS TRAVEL ALL THE WAY TO THE FLOOR WHEN PUSHED ON WITH FOOT PRESSURE. ABLE TO DUPLICATE CAPT'S RUDDER PEDALS SLIP FROM POSITION SELECTED AND TRAVEL TO THE FLOOR, FOUND PEDAL TRAVEL ADJUSTMENT CABLE AT SDR UALA2009100603137Amplifier · malfunctionedSATCOM HI GAIN FAILED. STATUS MSG01- ACTIVE CRUISE HARD; HGA HIGH POWER AMPLIFIER (LEFT) OR SATELLITE DATA UNIT (LEFT) OUTPUT CIRCUIT IS OPEN OR SHORTED. DB- SATELLITE DATA UNIT (LEFT) MSG-2360121 ACTIVE ER HARD. RESET HI GAIN CB AND SDU L CB, NO HELP. SSDR UALA2009100503107Lens · unsecureEXIT SIGN COVER FELL OFF AT DOOR 4L. FOUND ALL EMERGENCY LIGHT LENS AT DOOR 4L SECURED.SDR UALA2009100503101Idg · malfunctionedELEC GEN OFF R RIGHT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF AND ENGINE NOT SHUT DOWN. REPLACED RT IDG. COMPLETED IDG OPERATIONAL CHECK. ALL LIMITS NORMAL.SDR UALA2009100503100Handle · out of positionNO WATER PRESSURE IN ALL LAVS & ALL GALLEYS, FLIGHT DIVERTED. CHECKED WATER PANELS AND SERVICED WATER SYSTEM, NO HELP. AFTER LAV SERVICING ALL WATER PRESSURE HANDLE MUST NOT HAVE BEEN IN FULL CLOSE ON LAV SVC PANEL. OPS CHECK GOOD.SDR UALA2009100103087Idg · malfunctionedON TAXI OUT, RT ENGINE GEN DRIVE LIGHT ILLUMINATED AND RT GEN OFF LIGHT ILLUMINATED, SHUT DOWN ENGINE. RESTART ENG AND RIGHT GEN DRIVE LIGHT ILLUMINATED, GEN NOT POWERING BUS. DISCONNECTED RIGHT IDG. FOUND DELTA P POPPED. NO CONTAMINATION TO EXTERNAL OIL CSDR UALA2009100103086Heater · faultyELECTRICAL SMOKE ODOR. TURNED OFF BUNK HEATER, ODOR WENT AWAY. HEATER NOT TO BE USED. OPS GOOD, NO ELECTRICAL ODOR.
Back to Boeing 777-222