Boeing 777-222
Service difficulty reports · 9,715
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2024082602275Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT L1 DOOR FWD AREA. PERFORMED WIRING CHECK FOUND M33093 BATTERY PACK LOW CAPACITY, REPLACED M33093 BATTERY PACK AND NEW PACK TEST FOUND NORMAL IAW WDM 33-51-31 REV 90, & AMM 33-51-06-960-8 02 REV 101.SDR CALA2024082602274Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT R1 DOOR FWD AREA, PERFORMED WIRING CHECK FOUND M33094 BATTERY PACK LOW CAPACITY REPLACED M33094 BATTERY PACK AND NEW PACK TEST FOUND NORMAL IAW WDM 33-51-31 REV 90, & AMM 33-51-06-960-8 02 REV 101.SDR CALA2024082602273Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT L1 DOOR AFT A REA, PERFORMED WIRING CHECK FOUND M33424 BATTERY PACK LOW CAPACITY,REPLACED M33424 BATTERY PACK AND NEW PACK TEST FOUND NORMAL, IAW WDM 33-51-61 REV 90, AMM 33-51-06-960-8 02 REV 101.SDR CALA2024082302263Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT R3 DOOR AFT A REA REFER HAECO NON ROUTINE LOG PAGE:9494606, WIRING CHECK FOUND M33401 BATTERY PACK LOW CAPACITY REPLACED M33401 BATTERY PACK AND NEW BATTERY PACK I NSTALLATION TEST FOUND NORMAL AS PER WDM 33-SDR CALA2024082302262Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT B ZONE REFER HAECO NON-ROUTINE LOG PAGE:9494603, WIRING CHECK FOUND M33096 BATTERY PACK LOW CAPACITY REPLACED M33096 BATTERY PACK AND NEW BATTERYPACK IN STATION TEST FOUND NORMAL AS PER WDM 33-51-64 REV.90 AMSDR CALA2024082302256Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT R3 DOOR AREA FWD REFER HAECO NON-ROUTINE LOG PAGE:9494605,ORIGINATED BY EMP:V 905488,SPEC NO.B777-33-3-7015 PERFORMED BY EMP:V909210,WIRING CHECK FOUND M33404 BATTERY PACK LOW CAPACITY REPLACED M33404 BATTERY SDR CALA2024082202255Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT L4 DOOR AREA. TEST FOUND M33407 BATTERY PACK LOW CAPA CITY REPLACED M33407 BATTERY PACK AND NEW BATTERY PACK INSTALLAT ION TEST FOUND NORMAL AS PER WDM 33-51-71 REV.90 AMM 33-51-06-96 0-802 REV.101.SDR CALA2024082202254Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT R4 DOOR FWD AREA. WIRING CHECK FOUND M33408 BATTERY PACK LOW CAPACITY REPLACED M33408 BATTERY PACK AND NEW BATTERY PACK INSTALLATION TEST FOUND NORMAL AS PER WDM 33-51-66 REV.90 & AMM 33 -51-06-960-802 REV.10SDR CALA2024082202253Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT R4 DOOR GALLE Y AREA. WIRING CHECK FOUND M33409 BATTERY PACK LOW CAPACITY REFPLACED M33409 BATTERY PACK AND NEW BATTERY PACK INSTALLATION TEST FOUND NORMAL AS PER WDM 33-51-66 REV.90 AMM 33 -51-06-960-802 REVSDR CALA2024082202252Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY. WIRE CHECK FOUND M23 BATTERY PACK LOW CAPACITY REPLACED M23 BATTERY PACK AND NEW BATTERY PACK INSTALL ATION TEST FOUND NORMAL AS PER WDM 33-29-17 REV.90 AMM 33-51-06- 960-802 REV.101.SDR CALA2024082202251Battery Pack · dischargedFOUND EMERGENCY LIGHT BATTERY PACK LOW CAPACITY AT L3 DOOR AREA. WIRING CHECK FOUND M33405 BATTERY PACK LOW CAPACITY REPLACED M33405 BATTERY PACK AND NEW BATTERY PACK I NSTALLATION TEST FOUND NORMAL AS PER WDM 33-51-65 REV.90 AMM 33- 51-06-960-802 REV.101.SDR CALA2024090302366Fairing · missingRIGHT WING EXTERNAL INSPECTIONS {B777-06-3-7157} - NO. 2 ENG NO. 6 FAN BLADE FAIRING HAS APPROX 12" OF SEAL MISSING. SEE PIC. HOURS OR LESS. REQUEST DIP. REF AMM 72-31-07-200-801-N00 MATERIAL MISSING FOR MORE THAN 0.400 INCH (10.160 MM) IN LENGTH.REPLACE THE FSDR CALA2024081600449Bearing Seal · leakingDUE TO THE INFLIGHT SHUTDOWN ENGINE #2 WINDMILLING INSPECTION REQUIRED IAW AMM TASK 72-00-00-210-809-N02 ENG2 SN. 222183 (TSI= 3082, CSI 348 CYC). OIL LEAK IN TAIL PIPE REVIEWED AND DETERMINED TO BE LEAKING NR 3 BEARING. SEAL. MX. PERFM. PG SNAPSHOT SHOW OIL PSDR CALA2024081502224Skin · dentedRAMP REPORTS DENT DOOR 4L. LOWER RH AFT CORNER OF DOOR. APPEARS TO BE FRESH AND NOT DAMAGE PREVIOUSLY REPORTED ON LP 8877939. FURTHER INSPECTION FOUND OUTER DOOR EDGE SEAL DEPRESSOR DAMAGED ADDITIONAL PICTURES PICTURE ADD AND AIR LEAKING FROM DAMAGED CORNER. GSDR CALA2024081300423Circuit Card · faultyFIRE CARD ENG L EICAS STATUS LEFT ENGINE FIRE/OVERHEAT DETECTION CARD FAULT OR FAILURE, OR AI MS LOSS OF ARINC 629/429 COMMUNICATION WITH CARD. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2610011 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRSDR CALA2024080800388Outflow Valve · faultyUNABLE TO PRESSURIZE AIRCRAFT ON DEPARTUREAFT OUTFLOW VAVLE CORY SWITCH REMOVED, FOR REPLACEMENT. THE CONNECTOR REMOVED IN THE CEILING PANEL. THE BLEED AIR / PRESSURIZATION LIGHT PANEL AND THE MANUAL LDG. ALT KNOB REMOVED. ALL PARTS ARE ON THE CONSOL. REMOVSDR CALA2024080600376Relay · failedENG IGNITOR R2 STATUS MSG AWAITING TOMC APRVL TO DEF R ENG IGNITOR 2 PER MEL 7400D M-PROCEDURE C/W PLACARD INSTALLED TOMC APPROVES MEL 7400D DEF. RT ENG NBR 2 IGNITOR INOP PER MEL 7400D M-PROCEDURE C/W PLACARD INSTALLED *DM* REF. AIPC 74-11-21-02-01 ITEM 5 ADDSDR CALA2024082602272Skin · damagedAFT CARGO DOOR OUTER SKIN LOWER AFT CORNER HAS A REINFORCING DOU BLER INSTALLED UNABLE TO LOCATE AFT CARGO DOOR LOWER AFT CORNER OUTER SKIN REPAIRED IAW SRM 52-30-01-2R-17 REV 95.SDR CALA2024072902130Charger · failedDR R2 EMER LT CHARGER M33098 TEST FAIL REFER HX NR WO. 3536625 AND ORIGINAL BY DR R2 EMER LIGHT BATTERY CHARGER M33098 REPLACED AND TESTED NORM AL IAW AMM 33-51-06 WORK ACCOMPLISHED BY MECH AND INSPECTED BYSDR CALA2024072902129Battery · failedDR R4 M33408 EMER LIGHT BATTERY CAPACITY CHECK FAIL REFER HX NR WO. 3406720 AND ORIGINAL BY DR R4 M33408 EMER LIGHT BATTERY RELACED AND TESTED NORMAL IAW AM M 33-51-06 WORK ACCOMPLISHED BY MECH AND INSPECTED BYSDR CALA2024072902128Battery · no testDR L2 M33096 EMER LIGHT BATTERY CAPACITY CHECK FAIL REFER HX NR WO. 3406725 AND ORIGINAL BY DR L2 M33096 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL IAW AMM 33-51-06 WORK ACCOMPLISHED BY MECH AND INSPECTED BYSDR CALA2024072902127Battery · failedDR R3 EMER LT BATT M33401 TEST FAIL REFER HX NR WO. 3536653 AND ORIGINAL BY DR R3 EMER LIGHT BATTERY M33401 REPLACED AND TESTED NORMAL IAW A MM 33-51-06 WORK ACCOMPLISHED BY MECH AND INSPECTED BYSDR CALA2024073100331Blower · faultyLAV TANK 1 INDICATES 1/3 AFTER IT IS DUMPED REF LP 8731441, FWD BLOWER CREATING CONSTANT VACUUM AND UNABLE TO EMPTY LAV TANK. PULLED AND COLLARED CB Z1 ON PANEL 110 AND LAV TANK WAS EMPTIED. FURTHER T/S REQUIRED. REQUEST DEFERRAL REF MEL 3830T. OK TO DEF FWD SDR CALA2024073000316Warning Message · illuminatedT/O REJECTED AT 70KTS DUE TO CARGO DOOR. MAX BRAKE TEMP 2.9 ACCOMPLISHED HIGH ENERY STOP CONDITIONAL INSPECTION AS PER AMM 05-51-14-210-801. INSPECTED BRAKE ASSEMBLY AND BRAKES ARE FOUND IN GOOD CONDITION. AIRCRAFT DID NOT EXPERIENCE A HIGH TEMP BRAKING RTO ANSDR CALA2024072900305Pump · failedFUEL SCAVENGE PUMP FAIL INFLIGHT FAULT HISTORY SHOWS "CENTER TANK FUEL SCAVENGE WAS NOT COMPLETED". THIS OCCURED ON THE 22 AND 24TH JULY. MAINTENACE MESSAGE IS 28-11081. REF FIM 28-22 TASK 901. CHECKED FAULT HISTORY, FOUND MAINT MESSAGE HIT ON PREVIOUS LEG. CESDR CALA2024071802059Battery Pack · dischargedSUPPORT TASK - CABIN - DR R4 EMER LT (PWR PACK M33409) OPERATION TEST FAILED - CABIN DR R4 EMER LT (PWR PACK M33409) REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071802058Battery Pack · dischargedB777-33-3-7019 - R3 DR EMER LT BATTERY PACK M33401 CAPACITY CHK FAIL - R3 DR EMER LT BATTERY PACK M33401 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071802057Battery · dischargedSUPPORT TASK - CABIN DR L3 EMER LT (PWR PACK M33406) OPERATION TEST FAILED - CABIN DR L3 EMER LT ( PWR PACK M33406) REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-5 1-06.SDR CALA2024071802056Battery · dischargedSUPPORT TASK - CABIN - DR R4 EMER LT (PWR PACK M33408)OPERATION TEST FAILED. CABIN - DR R4 EMER LT (PWR PACK M33408) REPLACED AND INSTALLATION TEST CARRIED WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071800242Access Panel · missingPDA 2 R/H ENGINE STRUT PRESSURE RELIEF DOOR/ACCESS PANEL 443CL FOUND MISSING ON ARRIVAL. PHOTO ADDED. NIL STOCK LHR. CDL APPLIED. DISPATCH DESK: 67 NAME: AC DATE: 19-MAR-24- OK TO PLACE PDA 2 R/H ENGINE STRUT PRESSURE RELIEF DOOR/ACCESS PANEL 443CL FOUND MISSDR CALA2024072302091Skin · damagedCUSTOMER PICKUP SHEET PLEASE REMOVE AND REPLACE DOUBLER AT STA 2000-2017 SRE 30L-33L. DUE TO NO RECORD OF REPAIR REFER HX NR WO. 3460850 AND ORIGINAL BY V940359.SDR CALA2024071502030Steering Sys · malfunctionedMAIN GEAR STEERING EICAS ADVISORY EITHER MAIN GEAR AFT AXLE IS INDICATING- NOT LOCKED WHEN IT SHOU LD BE LOCKED. FOUND MX MSG ON INBOUND FLIGHT DECK EFFECT MX MSG# 32-63010 MG ON MEL VERIFIED BOTH PCA''S ARE LOCKED AND DISABALED PULLED AND COLLARED MAIN GEAR SSDR CALA2024071502029Battery Pack · dischargedB777-33-3-7019 CABIN LH DR1 EMER LT PWR PACK M33424 CAPACITY CHECK FAIL. CABIN LH DR 1 EMER LT PWR PACK M33424 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071502028Battery Pack · dischargedCABIN LH DR1 EMER LIGHT PWR PACK M33093 CAPACITY CHECK FAIL. CABIN LH DR 1 EMER LIGHT PWR PACK M33093 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071502025Battery Pack · dischargedCABIN RH2 EMER PWR PACK M33098 CAPACITY CHK FAIL. CABIN RH 2 EMER PWR PACK M33098 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071502024Battery Pack · dischargedB777-33-3-7019 : CABIN LH DR4 EMER LIGHT PWR PACK M33407 CAPACITY CHK FAIL. CABIN LH DR 4 EMER LIGHT PWR PACK M33407 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071502023Battery Pack · dischargedCABIN RH 2 EMER PWR PACK M33097 CAPACITY CHK FAIL. CABIN RH 2 EMER PWR PACK M33097 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071502022Battery Pack · dischargedB777-33-3-7019 : CABIN LH2 EMER PWR PACK M33099 CAPACITY CHK FAIL. CABIN LH 2 EMER PWR PACK M33099 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06.SDR CALA2024071502021Battery Pack · dischargedB777-33-3-7019 - L3 DR EMER LT BATTERY PACK M33400 CAPACITY CHECK FAIL. L3 DR EMER LT BATTERY PACK M33400 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071502020Battery Pack · dischargedB777-33-3-7019 - L2 DR EMER LT BATTERY PACK M 33096 CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.3341363. L2 DR EMER LT BATTERY PACK M33096 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024071502019Battery Pack · dischargedB777-33-3-7019 - R1 DR EMER LT POWER SUPPLY BATTERY PACK (M33094) CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.3341353. R1 DR EMER LT POWER SUPPLY BATTERY PACK(M33094) REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2024070900174Bulb · burned outELECTRICAL ODOR ON DESCENT, CAPT ADVISE 5 MINS PRIOR LANDING, PURSOR REPORTED ELECTRICAL ODOR BY GALLEY 2. CHECKED LAMPS, OVENS, OUTLETS, WORKLIGHTS, TRASH RECEPTACLES, LAV LIGHTS AND FLUSH MOTOR FOR OPERATION PERTAINING TO ELECTRICAL ODOR. FOUND 2 GALLSDR CALA2024070901979Water System · pressure lossAIR RETURN DUE TO WATER SYSTEM NOT PRESSURIZING RESULTING IN NO WATER. PURGED AIR FROM ALL WATER SYSTEM SUPPLY SOURCES, COFFEEMAKES, GALLEY WATER SPIGOTS AND LAVATORY SINK SPIGOTS. WATER FLOWS FROM ALL SPIGOTS AND COFFEEMAKERS NORMALLY. COFFEE MAKERS WATER FSDR CALA2024070301956Screw · missingPDA 3 REFRENCE LOG# 8453862 LEFT SIDE SLAT LINKAGE FAIRING PANEL ONE SCREW MISSING ENTERED IN ERROW SHOULD BE CATAGORY 3 REF LP 8457515 FOR CORRECT PDA CATEGORY 3 LOG ENTRY. PDA 3 SCREW FOUND MISSING FROM PANEL 511CB (LEFT SIDE SLAT LINKAGE PANEL)SDR CALA2024062500102Wire Harness · damagedREJECTED TAKEOFF AT 73 KTS DUE TO DOOR AFT CARGO EICAS. OPTIONAL LARGE AFT CARGO DOOR INDICATION SYSTEM FAULT DETECTED. VERIFIED AFT CARGO WAS CLOSED, LATCHED & LOCKED CORRECTLY. FDE SHOWS FAULT 52-11960 ACTIVE. CYCLED AFT CARGO DOOR OPEN & INSPECTED CAMS, & ASDR CALA2024062601892Power Cable · damagedPDA 2 FOUND ON ARRIVAL EXTERIOR GROUND POWER SERVICE DOOR WITH SECONDARY POWER CORD STRAP OUTSIDE OF DOOR AND WHEN INSPECTED INSIDE OF DOOR FOUND HOOK MISSING. DEFERRING EXTERNAL SECONDARY POWER SYSTEM PER MEL 2441D DUE TO POWER ACCESS DOOR. DEFERRED AND PLACASDR CALA2024061700009Tire · worn07 MLG TIRE IS NEARING IT SERVICE LIFE LIMIT TECH MUST MEASURE T HE LOWEST TREAD UPON INITIALIZING PLA AND ENTER THAT MEASURMENT IN THIS LOG. TERMINATING ACTION REQUIRES TIRE REPLACEMENT. INSPECTED TIRE, TREAD WEAR IS AT 1/32 PER AMM, ANY PART OF ANY GROOVE ISDR CALA2024061701811Fmu · faultedLEFT ENGINE FUEL FLOW WILL NOT SHUT OFF WITH CUTOFF SWITCH OR FIRE HANDLE. RECONNECTED D71024P AT CORE/STRUT AND NOW HAVE 28VDC AT FMU D71124. REQUIRES OPS CHECK. WITH NO FIRE OR SMOKE. CONNECTOR DM76001C. SHOOK DOWN WIRES FROM FMU TO CORE/STRUT CONNECTOR, UNASDR CALA2024061701816Warning Message · illuminatedBLEED OFF ENG R EICAS ADVISORY RIGHT ENGINE BLEED VALVE CLOSED FOR SYSTEM FAULT OR SWITCH OFF, AND THE ENGINE IS NOT SHUTDOWN. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 3610320 FLIGHT STATUS: L INTERMITTENCE CODE: M PH: CLIMB NARRATIVE: AIR SUPPLYSDR CALA2024071001989Defibrillator · out of positionAFT AED NEEDS TO BE REPOSITIONED SO THAT GREEN LIGHT IS VISIBLE REPOSITIONED AED, GREEN LIGHT VISABLE
Back to Boeing 777-222