Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA03521Engine · oil consumptionNR 2 ENGINE OIL CONSUMPTION EXCEEDS LIMIT.SDR 2008UALA03514Idg · malfunctionedELEC GEN DRIVE L LEFT IDG FAULT (LOW INTERNAL OIL PRESSURE). REPLACED IDG PER MM 24-11- 01 OPS AND LEAK CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03513Gearbox · making metalFOUND METAL ON NR 2 ENGINE MAIN GEAR BOX CHIP DETECTOR. ENGINE REMOVED. SHOP TEARDOWN REVEALED THAT MAIN GEARBOX MB7 BEARING HAD FAILED. ALL RELEVANT HARDWARE WAS RETURNED TO MANUFACTURER FOR FURTHER ANALYSIS. THIS IS AN ONGOING PROBLEM THAT MANUFACTURER ISSDR 2008UALA03497Controller · failedNR 1 ENG PRSOV CONTROLLER FAILED. *S/D* NR 1 ENGINE PRSOV CONTROLLER FAILED. INSTALLED NEW PRSOV CONTROLLER, OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03496Valve · failedNR 2 ENGINE PRSOV FAILED HEALTH CHECK. *S/D* NR 2 ENGINE PRSOV FAILED HEALTH CHECK. REPLACED PRSOV PER MM 36- 11-18 401, OPS TEST GOOD. AC OK FOR SERVICE.SDR 2008UALA03463Structure · crackedRT AFT NLG DOOR AFT LOWER CORNER CRACKED APPROX 3"X1" AREA. *S/D* SUSPECT NORMAL AC OPERATION. ACCOMPLISHED INTERIM REPAIR PER EVA-71532. ** MF2588 CREATED TO MONITOR ** AC OK FOR SERVICE.SDR UALA2008111303454Indicator · inoperativeAPU FIRE BOTTLE ARM AND BOTTLE DISCHARGE AMBER LIGHTS ON P40 PANEL INOP. AFTER EXTENSIVE TROUBLESHOOTING FOUND LIGHT ASSEMBLIES TO BE FAULTY. CONFIRMED NEED 2 EA. LIGHT ASSY. REPLACED 2EA BOTTLE DISCHARGE LIGHT ASSEMBLIES.SDR 2008UALA03480Generator · faultyRT BACKUP ELECTRICAL POWER SYSTEM INOP. *S/D* FOUND RT BACK-UP GENERATOR HAS SHEARED SHAFT. REPLACED NR 2 ENGINE BACK UP GENERATOR PER MM-24-25-01. ACCOMPLISHED IDLE RUN NR 6 TEST, REF: MM-71-00-00-PAGE 543, REF: MM-24-25-01, PAGE 417 TESTED GOOD. AC OKSDR 2008UALA03454Warning Light · illuminatedAPU FIRE BOTTLE ARM AND BOTTLE DISCHARGE AMBER LIGHTS ON P40 PANEL INOP.SDR 2008UALA03453Controller · failedPACK MODE L LEFT PACK AIR CYCLE MACHINE HAS FAILED, OR LEFT ECONOMY COOLING VALVE FAILED OPEN, OR BOTH LEFT CONDENSOR INLET TEMP SENSORS FAILED. LEFT PACK IS OPERATING IN A NON-NORMAL MODE (HEAT EXCHANGER ONLY COOLING MODE). ADVISORY CREW COMMENTS: PACK MODSDR 2008UALA03452Fire Loop · failedFIRE LOOP 2 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG-2610232 ACTIVE DC HARD. SUSPECT IMPROPERLY INSTALLED. REPLACED WIRE HARNESS FROM M26OO5 TO M26006, REF WD26-11-21. FOUND LOOP M26006 DAMAGED. REPLACED M26006 PER MM26-11-01. TESSDR 2008UALA03457Start Valve · faultyRIGHT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION. ADVISORY MSG-8061562 INACTV TA MODE. *S/D* FOUND FAULTY STARTER AIR VALVE. REPLACED STARTER VALVE ASSEMBLY PER 80-11-02. ALL OPS AND STARTS NORMAL MSG ERASED. AC OK FOR SERVICE.SDR 2008UALA03455Fuel Sys · faultyAPU SYS MSG DISPLAYED PRIOR DEPT MNT MSG 49-1042- DISPLAYED FIM 49-30 TASK 802 FAULTS APU WIRE HARNESS OR FUEL CLUSTER. *S/D* FOUND FAULTY FUEL CLUSTER. REPLACED APU FUEL CLUSTER PER AMM 49-31-31. OP CHECKED GOOD. VERIFICATION FLIGHT CONFIRMS NORMAL OPERASDR 2008UALA03402Idg · faultyELEC GEN SYS R IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; INTEGRATED DRIVE GENERATOR (R) FREQUENCY IS LOW. DB- GENERATOR CSDR 2008UALA03456Eec · malfunctionedENGINE EEC C1 L LEFT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENGINE CONTROL SYSTEM IS OPERATING WITH REDUCED REDUNDANCY. STATUS MSG-7361081 INACTV ER INTER, MAINT MESSAGE 73-61081 PRESENT T-3 THERMOCOUPLE PROBE. MSG NOT ACTIVE, INTERMITTENT.SDR 2008UALA03414Valve · faultyBLEED OFF ENG L - EICAS MSG ON TAXIOUT. SUSPECT FAULTY HIGH PRESSURE SHUT OFF VALVE. REPLACED NR 1 ENGINE HPSOV REF AMM 36-11-07. AC OK FOR SERVICE.SDR 2008UALA03403Lens · missingLIGHT COVER ON THE AFT SIDE OF DOOR 4L IS MISSING. *S/D* SUSPECT IMPROPERLY INSTALLED. REPLACED LIGHT COVER. AC OK FOR SERVICE.SDR 2008UALA03364Solenoid · faultyENGINE START VALVE R RIGHT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION OR STARTER AIR VALVE POSITION INDICATION IS LOST. STATUS MSG-8061562 INACTV SD MODE. *S/D* SUSPECT FAULTY STARTER VALVE SOLENOID. REPLACED STARTER AIR VALVE SOLENOID RESDR 2008UALA03362Lamp · burned outEMERGENCY LIGHTS ON AFT END OF SEATS 2E & 3E ARE INOP. *S/D* SUSPECTED FAULTY LAMPS. REPLACED SEAT LIGHTS, OP CHECKED OK. AC OK FOR SERVICE.SDR 2008UALA03351Module · faultyDURING LIGHT TEST GREEN ON LIGHT FOR RAT DID NOT COME ON. *S/D* SUSPECT FAULTY RAT CHECK OUT MODULE. REPLACED MODULE RERACKED A4 CARD, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03366Isolation Valve · faultyL BLEED ISOLATION VALVE FAULT. SUSPECT FAULTY ISOLATION VALVE. REPLACED LT ISOLATION VALVE PER MM 36-12-01. AC OK FOR SERVICE.SDR 2008UALA03365Fseu · faultyEICAS STATUS MESSAGE FLAP SLAT CONTROL 2 SHOWS ON STATUS PAGE. *S/D* SUSPECT FAULTY FLAP-SLAT ELECTRONIC UNIT. REPLACED NR 2 FSEU, OPS CHECKED GOOD IAW MM 27-51-01. AC OK FOR SERVICE.SDR 2008UALA03337Pump · faultyTHE 'FUEL PUMP LT AFT' EICAS MSG DISPLAYED AND LOW PRESS LIGHT ON THE SW. FOUND NO POWER AT PUMP CONNECTOR ON PIN 4 (PHASE B1) SUSPECT RELAY K28123 INOP. REPLACED RELAY K28123 NO HELP. FOUND C PHASE SHORTED TO GROUND, SUSPECT WIRING OR PUMP. T-S BY REMOVING KSDR 2008UALA03328Engine · surgesRIGHT ENGINE EXPERIENCED 2 INCIDENTS OF SURGE AS EVIDENCED BY POPPING NOISE AND RPM ROLLBACK FOLLOWED BY FULL RECOVERY. PARAMETERS ARE NORMAL. SURGE WAS NOT COMMENSURATE WITH THROTTLE MOVEMENT. ALL FIM TROUBLESHOOTING, INCLUDING EXTENSIVE BOROSCOPE INSPECTISDR 2008UALA03363Controller · faultyNR 2 ENGINE PRSOV CONTROLLER FAILED HEALTH CHECK. *S/D* SUSPECT FAULTY CONTROLLER. REPLACED CONTROLLER PER MM 36-11-18-401. OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03361Filter · dirtyEQUIPMENT COOLING FAN WARNING HORN KEEPS GOING OFF. *S/D* SUSPECT DIRTY FILTER. REPLACED FILTER, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03320Idg · faultyL ENG IDG DRIVE LIGHT NOT ILLUMINATED. LT BULB PRESS TO TEST OK. MAINT MSG 24-31801. *S/D* SUSPECT FAULTY IDG AND BUG. REPLACED IDG PER MM 24-11-01 AND BUG IAW MM 24-25-01. ACCOMPLISHED ENGINE RUNS, NO LEAKS OIL SERVICED AS REQUIRED. AC OK FOR SERVICE.SDR 2008UALA03312Precooler · crackedLEFT ENGINE PRECOOLER LEAKING BEYOND LIMITS. *S/D* SUSPECT FAULTY PRE COOLER. REPLACED PRE COOLER LEAK CHECKED GOOD. AC OK FOR SERVICE.SDR UALA2008111303275Valve · faultyPACK MODE R RIGHT PACK AIR CYCLE MACHINE HAS FAILED, OR RIGHT ECONOMY COOLING VALVE FAILED OPEN, OR BOTH RIGHT CONDENSOR INLET TEMP SENSORS FAILED. RIGHT PACK IS OPERATING IN A NON-NORMAL MODE (HEAT EXCHANGER ONLY COOLING MODE). ADVISORY CREW COMMENTS: PACKSDR 2008UALA03284Lamp · burned outDOOR 3L EXTERIOR EMERGENCY LIGHT INOPERATIVE. *S/D* SUSPECT FAULTY LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03272Battery · faultyAPU BATTERY CHARGING 62 AMPS, POPPED CB. *S/D* SUSPECT FAULTY BATTERY AND CHARGER. REPLACED APU BAT AND CHARGER REF MM 24-31-05 AND 24-31-06. AC OK FOR SERVICE.SDR 2008UALA03275Unknown · failedPACK MODE R RIGHT PACK AIR CYCLE MACHINE HAS FAILED, OR RIGHT ECONOMY COOLING VALVE FAILED OPEN, OR BOTH RIGHT CONDENSOR INLET TEMP SENSORS FAILED. RIGHT PACK IS OPERATING IN A NON-NORMAL MODE (HEAT EXCHANGER ONLY COOLING MODE). ADVISORY CREW COMMENTS: PACKSDR 2008UALA03287Unknown · odorBURNING ODOR IN BC GALLEY WHEN ALL COFFEEMAKERS ON. CHECKED COFFEEMAKERS, HOT PLATES, OVENS, CEILING LIGHTS, GALLEY LIGHTS AND A CHILLER ALL OK. NO BURNING SMELL ON ARRIVAL. COULD NOT DUPLICATE PROBLEM. AC OK FOR SERVICE.SDR 2008UALA03248Idg · inoperativeA/C REPORTED LEFT GENERATOR DRIVE INOP. APU IN USE. HOWEVER APU CNTRL STATUS LIGHT HAS ILLUMINATED. SUSPECT FAULTY BEARING. REPLACED IDG OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03285Transducer · faultyFOUND LATCHED HYD PUMP PRI C2 MSG. *S/D* SUSPECT FAULTY PRESSURE TRANSDUCER. REPLACED PRESSURE TRANSDUCER, OP CHECKED OK. AC OK FOR SERVICE.SDR 2008UALA03237Light · missingSEAT 1F AFT EMERGENCY LIGHT ASSY MISSING. LIGHT ASSY REPLACED AND TESTED NORMAL.SDR 2008UALA03236Light · missingSEAT 1E AFT EMERGENCY LIGHT MISSING. EMERGENCY LIGHT ASSY REPLACED AND TESTED OK.SDR 2008UALA03286Fan · failedDETECTOR FAN 2 CARGO AFT AFT CARGO COMPARTMENT SMOKE DETECTOR FAN NR 2 FAILURE. REPLACED AFT CARGO SMOKE DETECTOR NR 2 FAN ASSY.SDR 2008UALA03220Battery Pack · inoperativePED 1L EPAS BATTERY PACK GREEN TEST LIGHTS INOP. *S/D* SUSPECT FAULTY BATTERY. REPLACED 9V BATTERIES IAW MM 52-11-20. AC OK FOR SERVICE.SDR 2008UALA03207Control Unit · faultyHYD PUMP DEM C1 LOW CENTER HYDRAULIC DEMAND PUMP NR 1 PRESSURE WHEN COMMANDED ON, OR CENTER DEMAND PUMP NR 1 OVERHEATED. STATUS MSG03- NOT ACTIVE INITIAL CLIMB MODE DEPENDENT; AIR DRIVEN PUMP (ADP) (C1) SPEED IS OUT OF RANGE. DB- HYDRAULIC INTERFACE MODULE (SDR 2008UALA03178Power Supply · faultySTATUS MSG01- ACTIVE CRUISE HARD; POWER SUPPLY ASSEMBLY (LEFT) HAS NO OUTPUT ON FLIGHT CONTROLS ARINC 629 BUSS (LEFT). DB- LEFT AIMS MSG-2458811 ACTIVE ER HARD. SUSPECT FAULTY POWER SUPPLY ASSEMBLY. REPLACED L-PSA PER MM 24-35-01, OP CHECKED GOOD. AC OK FORSDR 2008UALA03208Light · missingLIGHT AT 3B MISSING. RELAMPED LIGHT, OPS NORMAL.SDR 2008UALA03188Line · wornFOUND OUTER INSULATION ON HYD PRESS HOSE BURNED THROUGH TO STAINLESS BRAIDED LAYER. *S/D* FOUND HYDRAULIC LINE FRAYED. REPLACED PRESSURE HYDRAULIC LINE, NO LEAKS FOUND. AC OK FOR SERVICE.SDR 2008UALA03187Fan · failedDET FAN 2 CARGO AFT CARGO COMPARTMENT SMOKE DETECTOR FAN NR 2 FAILURE. FOUND AFT SMOKE DETECTOR FAN FAULTY. REPLACED AFT CARGO SMOKE DETECTOR NR 2 FAN ASSY.SDR 2008UALA03176Oxygen Mask · faultyOXYGEN MASK PROBLEM. SUSPECT FAULTY MASK BOX ASSEMBLY. REPLACED MASK BOX ASSEMBLY PER MM 35-11-18. AC OK FOR SERVICE.SDR 2008UALA03158Pump · malfunctionedHYD PRESS PRI C1 LOW CENTER SYSTEM HYDRAULIC PRIMARY PUMP NR 1 PRESSURE OR PUMP SWITCHED OFF. ADVISORY MSG-2912015 LATCHED ER MODE MSG-2912015 LATCHED ERR MODE -. REPLACED C1 PUMP. REPLACED & CONNECTED DM29304A & PINS, CHECKS GOOD.SDR 2008UALA03206Modulating Valve · faultyBLEED FAMV R RIGHT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED, OR RIGHT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG-3610320 LATCH DC MODE. SUSPECT FAN AIR MODULATING VALVE. REPLACED NR 2 ENGINE FAMV IAW MM 36-11-16. SDR 2008UALA03132Control Unit · faultyACTUATOR CONFIDENCE FAILED. MSG 27-10110, ELEVATOR POWER CONTROL UNIT (LEFT OUTBOARD) BLOCKING SOLENOID OPERATED VALVE IS NOT IN COMMANDED POSITION. AFTER EXTENSIVE TROUBLESHOOTING FOUND FAULTY L1 ACE. REPLACED L1 ACE, OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03210Generator · faultyNR 2 BUG SHOWED SERVICE ON MFD. *S/D* SUSPECT FAULTY BEARING. REPLACED BACKUP GENERATOR PER MM 24-25-01, OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03209Start Valve · faultyENGINE START VALVE L LEFT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION OR STARTER AIR VALVE POSITION INDICATION IS LOST. STATUS CREW COMMENTS: CHRONIC MSG-8061561 INACTV ES MODE, MSG-8061561 INACTV ES MODE. *S/D* FOUND FAULTY START VALVE.
Back to Boeing 777-222