Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA03148Solenoid Valve · faultyFLAPS PRIMARY FAIL PRIMARY (HYDRAULIC) FLAPS DRIVE FAILURE. FLAPS OPERATING IN SECONDARY (ELECTRIC) MODE. CAUTION MSG-2720372 LATCHD DC MODE. FAILED HIGH LIFT CONTROLS TEST. FOUND FLAPS PRIMARY LOW SPEED SOLENOID VALVE AT FAULT AND REPLACED REF MM 27-51-05SDR UALA2008111303097Connector · defectiveTHE LT OUTBOARD REFUEL VLV INOP. REPLACED CONNECTOR DV28108 REF WD 28-21-21 ON ACCOUNT OF INTERNALLY SHORTED WIRES 2 AND 5. REPLACED REFUEL VALVE CONTROL UNIT.SDR 2008UALA03069Idg · malfunctionedCREW REPORTED RT ENG IDG DRIVE LIGHT ILLUMINATED. SUSPECT FAULTY BEARING. REPLACED RT IDG PER MM 24-11-01. OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03103Disc · leakingLOW BOTTLE. RUPTURE DISC LEAKING. REMOVED AND REPLACED RUPTURE DISC. REPLACED RUPTURE DISC AND SLIDE BOTTLE. AC OK FOR SERVICE.SDR 2008UALA03097Valve · inoperativeLEFT OUTBOARD REFUEL VLV INOP.SDR 2008UALA03064Controller · shortedTHE "AIR SPLY L HTR" C-B ON P110 POS M16 WILL NOT RESET. SUSPECT HIGH PRESSURE CONTROLLER/FAN AIR SHORTED. REPLACED LT FAN HP CONTROLLER. RAN BOTH ENGINES. OPS OK. AC OK FOR SERVICE.SDR 2008UALA03039Skin · dentedRIGHT WING I/B MAIN FLAP UPPER SURFACE OUTBOARD SIDE ATTACHED SCREW HOLES HAVE 3 DENTS. SUSPECT TOOLING MARKS. ACP REPAIR PER AMECO 777EN -57-0045-01. THE REPAIR IS APPROVED BY BAC, AND 8100-9 THE REPAIR IS A PERMANENT REPAIR. AC OK FOR SERVICE.SDR 2008UALA03038Skin · wornLEFT WING O/B FLAP UPPER SURFACE ARE WORN AT LOCATIONS: 1" TO 9", 62" TO 71", 147" TO 168", AND 220" TO 240". DAMAGED LOCATION IS MEASURED FROM I/B END. MAX DAMAGE DEPTH IS .080". SUSPECT NORMAL AC OPERATION. ACP REPAIR PER AMECO, 777E N-57-0041-01. THE RSDR 2008UALA03037Skin · crackedLEFT WING I/B TRAILING EDGE MAIN FLAP UPPER SURFACE HAS CRACK AT LOCATION AT 82 INCHES FROM I/B END. SUSPECT NORMAL AC OPERATION. ACP REPAIR PER AMECO 777EN -57-0044-01. THE REPAIR IS APPROVED BY BAC 8100-9 THE REPAIR IS A PERMANENT REPAIR. AC OK FOR SERVISDR 2008UALA03036Skin · wornRIGHT O/B FLAP UPPER SURFACES ARE WORN. SUSPECT NORMAL AC OPERATION. ACP RPR FROM AMECO 777EN 57-0040-01. THE REPAIR IS APPROVED BY BAC 8100-9. THE REPAIR IS PERMANENT REPAIR. AC OK FOR SERVICE.SDR 2008UALA03033Ground Wire · shortedSPOILERS EICAS MESSAGE DISPLAYED. OUTBOARD SPOILERS INOP. MAINT MESSAGE 27-10500 SPOILER POWER CONTROL UNIT NR 1. AFTER EXTENSIVE TROUBLE SHOOTING AND PART REPLACEMENT. FOUND HIGH RESISTANCE SHORT TO SHIELD-GROUND. REF WDM 27-61-15 PG2 IN AREA AT RECEPTACSDR 2008UALA03034Oxygen Bottle · reads lowCREW O2 READING 1350 PSI. SUSPECT FAULTY OXYGEN BOTTLE. REPLACED O2 BOTTLE, LEAK CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02985Idg · lowNR 2 ENGINE IDG TOOK APPROXIMATELY 40 STROKES TO GET TO FULL. SUSPECT FAULTY O-RING. INSTALLED NEW IDG PER AMM 24-11-01-401. LEAK AND OP CHECK. AC OK FOR SERVICE.SDR 2008UALA03023Wire · shortedRIGHT GENERATOR FAILED WOULD NOT RESET. RIGHT GEN INOP. AFTER EXTENSIVE TROUBLE SHOOTING AND PART REPLACEMENT. FOUND W3951O-16 CHAFING & SHORTED TO GROUND. REPAIRED AND SECURED WIRING. REPAIRED CHAFFED WIRE AND OPS CHECK OK. AC OK FOR SERVICE.SDR 2008UALA02984Actuator · malfunctionedUNABLE TO GET BLEED AIR FROM APU. STATUS MSG'S APU & APU BLEED AIR WITH MAINT MSG'S 49-10990 INLET GUIDE VANE ACTUATOR DOES NOT FOLLOW COMMAND AND 49-10980 INLET GUIDE VANE ACTUATOR LVDT CIRCUIT FAILED. SFOLM REPLACED THE INLET GUIDE VANE ACTUATOR. THE APU OSDR 2008UALA03021Light · inoperativeEMERGENCY LIGHT AT SIDE OF SEAT 14C IS INOP. SUSPECT FAULTY LAMP. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03020Lamp · inoperativeEMERGENCY LIGHTS ON SIDES OF SEATS 21C AND 24C INOP. SUSPECT FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY 21C REPLACED LAMP 24C OP CHECKED GOOD.
AC OK FOR SERVICE.
SDR 2008UALA02983Check Valve · malfunctionedFUEL TRANSFER PROBLEM FROM CENTER TO THE RIGHT TANK. WITH CENTER TANK FEEDING ENGINES, THE CENTER TANK PUMPED ENOUGH FUEL INTO THE RIGHT TANK TO CAUSE RIGHT FUEL TANK TO OVER FILL AND CAUSE FUEL, APPROX 3000FT TO DUMP OVERBOARD THRU FUEL VENT. REPLACED RT FWSDR 2008UALA02981Controller · faultyLEFT ENGINE BLEED INOP IN FLIGHT. SUSPECT FAULTY HIGH PRESSURE FAN AIR CONTROLLER. REPLACED LT HPFAC RAN BOTH ENGINES. OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03022Lamp · burned outNR 1 GENERATOR DRIVE LIGHT NOT ILLUMINATED WITH ENGINE SHUTDOWN. SUSPECT FAULTY LAMP. REPLACED ROLS SWITCH DRIVE LIGHT, OPS NORMALLY PER MM 24-11-15. AC OK FOR SERVICE.SDR 2008UALA02979Controller · malfunctionedRIGHT ENG BLEED SYSTEM HAS LARGE PRESSURE FLUCTUATIONS WITH ASSOCIATED ENG PARAMETER FLUCTUATIONS IN CLIMB AND IN CRUISE. WITH RIGHT PACK SELECTED -OFF- THE PRESSURE AND ENG PARAMETERS ARE STABLE. REPLACED ASCPC FOR RT AIR SUPPLY. ASCPC INSTALLED AND CABIN PSDR 2008UALA02973Line · brokenUNWANTED FUEL TRANSFER TO RIGHT MAIN JUST AFTER TAKEOFF. LINE WAS BROKEN AT RIGHT MAIN TANK SHUT OFF VALVE. REPLACED RT TANK FLOAT SHUTOFF VALVES AND MADE NEW LINE TO RT TANK OUTLET FLOAT SHUT OFF VALVE REPLACED FUEL CONTROL UNIT. OP CHKS & LEAK CHKS GOOD. FOSDR 2008UALA02972Engine · contaminatedEVIDENCE OF METAL CONTAMINATION FOUND ON NR 1 ENG. METAL ON THE FORWARD MAGNETIC CHIP DETECTOR (MCD. ENGINE REMOVED PRIOR TO FURTHER FLIGHT. TEARDOWN FOUND THAT THE NR 2 BEARING HAD 3 BALLS WITH SPALLATION APPROXIMATELY 1/4-INCH TO 1/2-INCH IN SIZE. THE OUTESDR 2008UALA02970Module · faultyAIMS LRM MESSAGE DISPLAYED. FOUND M11 IN LEFT AIMS CABINET FAULTY. REPLACED LEFT AIMS M11 REF MM 31-41-02. SOFTWARE LOADED AND TEST OK. AC OK FOR SERVICE.SDR 2008UALA02910Slide · misinstalledENTRY DOOR 2L ESCAPE SLIDE SAFETY PIN HOLE IS OBSTRUCTED. SUSPECT IMPROPERLY INSTALLED. REPLACED SLIDE PER MM 25-6 6-01-401. AC OK FOR SERVICE.SDR 2008UALA02957Electronic Unit · activatedPRIMARY CHANNEL MESSAGE ON MAINTENANCE PAGE WHEN LOWERING FLAPS AND FLAPS ARE SLOW. SUSPECT FAULTY FSEU. REPLACED NR 2 FSEU REF. MM 21-51-01. OP CHECKS GOOD. AC OK FOR SERVICE.SDR 2008UALA02956Gcu · faultyELEC GEN OFF R RIGHT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF, AND ENGINE NOT SHUT DOWN. ADVISORY MSG01- NOT ACTIVE DESCENT MODE DEPENDENT; INTEGRATED DRIVE GENERATOR (R) FREQUENCY IS LOW. DB- GENERATOR CONTROL UNIT (R) MSG02- LATSDR 2008UALA02922Stator · crackedNR 1 ENG FOUND 1EA 9TH STG COMPRESSOR VANE CRACKED COMPLETELY THRU VIEWED FROM CONVEX SIDE. PER THE RECOMMENDATIONS OF MANUFACTURER ALL OPERATORS WIRE PW4000/72-35-25/CTS:ERC:08-5-08-1, PERFORMED A BORESCOPE INSPECTION OF THE SUBJECT ENGINE TO CHECK FOR HP COSDR UALA2008111302896Skin · damagedLIGHTNING STRIKES LT HORIZ STAB UPPER SURFACE, INBOARD END. FOUND LIGHTNING STRIKES. ACCOMPLISHED PERMANENT REPAIR PER SRM 51-20-06. AC OK FOR SERVICE.SDR 2008UALA02896Skin · damagedLIGHTNING STRIKES LT HORIZ STAB UPPER SURFACE, INBOARD END.SDR UALA2008111302849Sensor · faultyBLEED OFF ENG L LEFT ENGINE BLEED VALVE CLOSED FOR SYSTEM FAULT OR SWITCH OFF, AND THE ENGINE IS NOT SHUTDOWN. ADVISORY MSG-3610500 LATCHD ER MODE MSG-3610500 LATCHD ER MODE. REPLACED DUAL TEMP SENSOR. RAN MAT TEST CHECK GOOD, AND LEAK CHECK GOOD.SDR 2008UALA02850Connector · damagedTHE PFC FAILS THE OPERATIONAL TEST. AFTER TROUBLE SHOOTING FOUND BAD CONNECTION. CLEANED NR 11 SPOILER ACTUATOR CONN. TEST PASSED. AC OK FOR SERVICE.SDR 2008UALA02849Bleed Valve · malfunctionedBLEED OFF ENG L LEFT ENGINE BLEED VALVE CLOSED FOR SYSTEM FAULT OR SWITCH OFF, AND THE ENGINE IS NOT SHUTDOWN. ADVISORY MSG-3610500 LATCHED ER MODE MSG-3610500 LATCHED ER MODE.SDR UALA2008111302843Switch · faulty"STAB AUTO SHUTDOWN" STATUS MSG IS DISPLAYED ON EICAS. STAB SYS GND TEST FAILS. EXISTING FAULTS MAINT MSG 27-10007, 27-10010..UNABLE TO CONTROL STAB TRIM USING RT STAB TRIM CUTOUT SWITCH, STAB CONTINUES TO MOVE WITH SWITCH IN CUTOUT. REPLACED STCM SHUTOFF VALSDR 2008UALA02881Oxygen Mask · defectiveCREW COMMENTS: F/O O2 MASK STRAPS WILL NOT TIGHTEN. SUSPECT PRE FLIGHT CHECKS. REPLACED FIRST OFFICERS OXYGEN MASK. AC OK FOR SERVICE.SDR 2008UALA02843Stabilizer · malfunctioned"STAB AUTO SHUTDOWN" STATUS MSG IS DISPLAYED ON EICAS. STAB SYSTEM GND TEST FAILS. EXISTING FAULTS MAINT MSG 27-10007, 27-10010. UNABLE TO CONTROL STAB TRIM USING RIGHT STAB TRIM CUTOUT SWITCH, STAB CONTINUES TO MOVE WITH SWITCH IN CUTOUT.SDR 2008UALA02841Control Unit · faultedHYDRAULIC PUMP DEM C1 LOW CENTER HYDRAULIC DEMAND PUMP NR 1 PRESSURE WHEN COMMANDED ON, OR CENTER DEMAND PUMP NR 1 OVERHEATED. STATUS MSG-2910420 LATCHD DC MODE MSG-2910420 LATCHED DC MODE MSG-2910450 LATCHED AP MODE. FOUND LOGIC SPEED CONTROL UNIT FAULTY.SDR 2008UALA02842Pcu · malfunctionedEICAS ADV MSG DISPLAYED SPOILERS INTERMITTENTLY, MSG 27-11503 FIM TASK 27-61 TASK 821. SUSPECT FAULTY POWER CONTROL UNIT. REPLACED NR 4 SPOILER PCU PER MM 27-61-09. OPS CHECK NORMAL. AC OK FOR SERVICE.SDR 2008UALA02775Circuit Card · malfunctionedFUEL PRESSURE PROBLEM. AFTER TROUBLE SHOOTING FOUND FAULTY SIGNAL CONDITIONING CARD. REPLACED SIGNAL CONDITIONING CARD PER MM24-09-00 ALL OPS NORMAL. ACFT OK FOR SERVICE.SDR 2008UALA02765Sign · looseEMERGENCY EXIT SIGN AT DOOR 4L IS LOOSE. REPLACED LIGHT ASSEMBLY LIGHT. OP CHECKS OKAY.
SDR 2008UALA02751Light · disconnectedSEAT 2F EMERGENCY AISLE LIGHT STRIP NOT CONNECTED. REPLACED LIGHT. OPS CHK'D OKAY.SDR 2008UALA02767Air Filter · dirtyEQUIPMENT COOLING HORN ON AND EQUIP COOLING EICAS. FOUND DIRTY AIR FILTER. REPLACED AIR FILTER PER MM -21-27-02. OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA02763Light · unsecureSEAT 3F SEAT MOUNTED EMERGENCY LIGHT CAME OFF. FOUND LIGHT ASSEMBLY LOOSE. SECURED LIGHT ASSY. OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA02711Slide · low pressureMAIN ENTRY DOOR 3R SLIDE PRESSURE LOW. SUSPECT FAULTY O-RING. REPLACED SLIDE ASSEMBLY PER AMM 25-66-01. OPS CHECK OK. AC OK FOR SERVICE.SDR 2008UALA02707Compressor · failedAIR COMPRESSOR MOTOR BURNED UP AT DEPT, INITIAL CALL WAS FOR SMOKE ODOR IN AFT GALLEY. SUSPECT FAULTY BEARING. REPLACED AIR COMPRESSOR PER AMM 38-42-01. POTABLE WATER SYSTEM OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA02754Pump · low pressureFUEL PUMP L FWD LEFT FORWARD (BOOST) FUEL PUMP SWITCH ON AND PUMP OUTPUT PRESSURE LOW. STATUS MSG01, LATCHED CRUISE MODE DEPENDENT, L FWD FUEL BOOST PUMP PRESSURE SWITCH SIGNAL IS LOW WITH L FWD FUEL BOOST PUMP ON. DB- ELMS P310 ELECTRONICS UNIT MSG-2813111SDR 2008UALA02753Lens · missingEMERGENCY AISLE LIGHT IS MISSING LENS ON SEAT 1E. LENS MISSING ON SEAT 2E. SUSPECT FAULTY LIGHT ASSEMBLY. REPLACED 1E EEL LIGHT AND OPS NORMAL. SEAT 2E ALSO TESTS NORMAL. ACFT OK FOR SERVICE.
SDR 2008UALA02752Connector · looseAFT SECTION OF EEL STRIP ON SEAT 1F INOP. SUSPECT LOOSE CONNECTION. SECURED CONNECTION OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02708Line · leakingNR 2 ENG HYD FLUID DRIPPING FROM BOTTOM OF COWLING AT 1 DROP PER SECOND. FLUID IS HYDRAULIC OIL NOT ENGINE OIL FROM LINE BEHIND PYLON PANEL 442BR. TIGHTENED "B" NUTS ON HYD LINES AND NOW ALL LEAK CHECKS OK.SDR 2008UALA02696Combust Chamber · damagedNR 1 ENGINE COMBUSTION CHAMBER DAMAGE BEYOND LIMITS. FOUND COMBUSTION CHAMBER CLAMP PROTRUDING INTO THE GASPATH. ENGINE REPLACED PRIOR TO FURTHER FLIGHT. TEARDOWN REVEALED THAT THE COMBUSTION CHAMBER CLAMP (C/C CLAMP) HAD BROKEN AT THE 3 O'CLOCK POSITION. ROO
Back to Boeing 777-222