SDR CALA2024031800766Battery Pack · no testB777-33-3-7019 - DR L3 M33406 EMER LIGHT BATTERY TEST FAIL TRANSFER REFER NON-ROUTINE WO.2913795 AND ORIGINATED BY DR L3 M33406 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 ATTACH FORM 44-0008 ITEM 1TO 2.SDR CALA2024031800765Charger · no testB777-33-3-7019 - DR R2 M33404 EMER LIGHT BATTERY CHARGER TEST FAIL - TRANSFER REFER NON-ROUTINE WO.2913810 AND ORIGINATED BY 1 DR R2 M33404 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 .SDR CALA2024031800764Battery Pack · no testB777-33-3-7019 - DR L1 M33424 EMER LIGHT BATTERY TEST FAIL TRANSFER REFER NON-ROUTINE WO.2913807 AND ORIGINATED DR L1 M33424 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PE R AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2.SDR CALA2024031800763Battery Pack · no testB777-33-3-7019 - DR R1 M33094 EMER LIGHT BATTERY TEST FAIL TRANSFER REFER NON-ROUTINE WO.2904901 AND ORIGINATED BY DR R1 M33094 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PE R AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2.SDR CALA2024031800778Guide · missingPDA 2. FOUND LINK GUIDE FOR HYD LINE MISSING ON ARRIVALR/H MLG MISSING GUIDE (ON O/B SIDE) FOR HYDRAULIC LINE ON FWD SUPPORT. REF IPC 32-41-02A ITEM 85 REPLACED GUIDE ASSY.SDR CALA2024031500743Sense Line · leakingENG EEC MODE R EICAS ADVISORY RIGHT ENGINE ELECTRONIC ENGINE CONTROL (EEC) IS IN THE ALTERNATE CONTROL MODE (EITHER BY DEFAULT DUE TO A CONTROL FAILURE OR MAN UALLY SELECTED BY THE FLIGHT CREW). FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 7761032 FLISDR CALA2024031300713Battery Pack · no testB777-33-3-7019, DR R3 M33401 EMER LIGHT BATTERY TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2960138 AND ORIGINATED BY . DR R3 M33401 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 AND ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED.SDR CALA2024031300712Charger · no testB777-33-3-7019, DR R3 M33401 EMER LIGHT BATTERY CHARGER TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2960129 AND ORIGINATED . DR R3 M33401 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2024031100687Wheel · missingPDA 1 #10 MLG WHEEL ASSY FELL OFF ON TAKEOFF. ACCOMPLISHED CONDITIONAL INSPECTION FOR PART DEPARTED AIRPLANE IN REF TO AMM 05-51-59. NO DEFECTS NOTED CONDITIONAL INSPECTION WAS ACCOMPLISHED IN REF TO AMM 05-51-59. PARTS TRANSACTION UPDATE R & R #10 TIRE REF ASDR CALA2024030800662Battery Pack · no testB777-33-3-7019, DR L1 M33424 EMER LIGHT BATTERY CAPACITY CHECK FAIL. DR L1 M33424 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2024030100616Tube · brokenTHRUST ASSYMETRY COMP FAULT TECH SUPPORT UPDATE. MBF SHOWING MAINT MESSAGE 77-61122. USE FIM 77-11 TASK 805 TO INVESTIGATE POSSIBLE P4.95 (P5) LINE LEAKAGE. IADLM MACINNES. FOUND P 4.5 (P5) LINE LEAKING AIR. REMOVED AND REPLACED RIGHT ENGINE, AFT MOST SEGMENTSDR CALA2024030100614Oil System · leaking#1 ENGINE OIL QTY WENT TO 0 AFTER FLAP CLEANUP FOLLOWED BY DECREASING OIL PRESSURE. ENG WAS SHUTDOWN PER CHECKLIST WITH OIL PRESSURE AT 90PSI AND DECREASING. ENGINE WINDMILL FOR APPROX 45 MINUTES AFTER SECURING IT. FUEL SERVO HEAT EXCHANGER SUPPLY LINE 2EA BOLSDR CALA2024022700559Battery Pack · no testDOOR L3 EMERGENCY POWER PACK (M33406) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, REPLACED DOOR L3 EMERGENCY POWER PACK ( M33406) AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NOR MAL,REF AMM 33-51-06-960-802 REV 100,SDR CALA2024022700558Battery Pack · no testDOOR L3 EMERGENCY POWER PACK (M33400) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, REPLACED DOOR L3 EMERGENCY POWER PACK ( M33400) AND PERFORMED THE INSTALLATION TEST.THE RESULT FOUND NOR MAL,REF AMM 33-51-06-960-802 REV 100,SDR CALA2024022700562Battery Pack · no testDOOR R2 EMERGENCY POWER PACK (M33098) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES. REPLACED DOOR R2 EMERGENCY POWER PACK (M33098) AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NORMAL REF AMM 35-51-06-960-802 REV100.SDR CALA2024022700561Battery Pack · no testDOOR R2 EMERGENCY POWER PACK (M33097) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES. REPLACED DOOR R2 EMERGENCY POWER PACK (M33097) AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NORMAL REF AMM 33-51-06-960-802 REV100,SDR CALA2024022700560Battery Pack · no testDOOR R3 EMERGENCY POWER PACK (M33404) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, REPLACED DOOR R3 EMERGENCY POWER PACK (M33404) AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NORMAL REF AMM 33-51-06-960-802 REV100,SDR CALA2024022700557Battery Pack · no testDOOR L1 EMERGENCY POWER PACK(M33424)CAPACITY CHECK FOUND CAN''T S TAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, REPLACED DOOR L1 EMERGENCY POWER PACK ( M33424) AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NOR MAL,REF AMM 33-51-06-960-802 REV 100,SDR CALA2024022700556Battery Pack · no testDOOR R1 EMERGENCY POWER PACK (M33094) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, REPLACED DOOR R1 EMERGENCY POWER PACK ( M33094) AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NOR MAL,REF AMM 33-51-06-960-802 REV 100,SDR CALA2024022700555Battery Pack · no testDOOR L2 EMERGENCY POWER PACK(M33096)CAPACITY CHECK FOUND CAN''T S TAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, ,REPLACED DOOR L2 EMERGENCY POWER PACK(M 33096)AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NORMA L,REF AMM 33-51-06-960-802 REV 100,SDR CALA2024022700554Battery Pack · no testDOOR R4 EMERGENCY POWER PACK (M33409) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, REPLACED DOOR R4 EMERGENCY POWER PACK ( M33409) AND PERFORMED THE INSTALLATION TEST,THE RESULT FOUND NOR MAL,REF AMM 33-51-06-960-802 REV 100.SDR CALA2024022800593Warning Message · illuminatedREJECTED TAKEOFF AT 35KIAS, MAIN GEAR STEERING EICAS MAIN GEAR STEERING STATUS POPPED UP ON TAXI, DISAPPEARED THAN FOLLOWED MAINTENANCE ACTION, PULLED BREAKER (N27) ON P110 PANEL, CAME BACK AND STAYED ON EICAS LOCKED OUT PCAS MAIN GEAR STEERING SYSTEM - MEL 32SDR CALA2024022200504Battery Pack · dischargedM/D L2 DOOR 1EA EMER LT POWER PACK(M33096) FOUND LOW CAPACITY,OR IGINATED BY EMP V905377,REF TO HAECO NON ROUTINE NO.9479192,SPEC NO.B777-25-3-7250. PERFORMED BY EMP V905377,REPLACED L2 DOOR EMER LT POWER PACK(M33 096) AND CARRIED OUT OPERATION TEST FOUND NORMSDR CALA2024022200501Battery Pack · dischargedM/D L1 DOOR 1EA EMER LT POWER PACK(M33093) FOUND LOW CAPACITY. REPLACED EMER LT POWER PACK(M33093) AND CARRIED OUT O/P TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 100.SDR CALA2024022200500Battery Pack · dischargedM/D L2 DOOR 1EA EMER LT POWER PACK(M33099) FOUND LOW CAPACITY. REPLACED EMER LT POWER PACK(M33099) AND CARRIED OUT O/P TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 100.SDR CALA2024022700563Actuator · inoperativeCONFIGURATION GEAR LOW SPEED ABORT MAIN GEAR STEERING ST REQUIRE MEL FOR THE MAIN GEARS STEERING PULLED C/B ON PANEL P110 N27 FOR THE MEL SPEED WAS NORMAL. COMPLIED WITH MEL SPEED BELOW 40KNOTS AND BRAKE IS READING ZERO AND COLD. APPROVED FOR MEL 3253A MMSG 32SDR CALA2024021900451Battery · dischargedB777-33-3-7019 - RH NO.2 DR FWD EMER LT BATTERY M33097 CAPACITY LOW. RH NO.2 DR FWD EMER LT BATTERY M33097 REPLACED AND TEST OKAY IAW AMM 33-51-06SDR CALA2024021300413Controller · faultyCABIN PRESSURE ALERT ON FLIGHT ATT PANEL. PA AU TO TO DON O2 MA SKS ADDING AMM REF FOR CABIN PRESSURIZATION, 05-51-24 ADDING ROTABLE PARTS EXCHANGE. PA/CI HAS BEEN CHANGED RECENTLY AND SUSPECT BOX WAS BAD FROM STOCK. OLD BOX FAULTED MSG 23-38841 WHICH SHOWED NSDR CALA2024020800361Battery Pack · dischargedDOOR L3 EMERGENCY POWER PACK (M33406) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES REF HAECO NR NO.947861 2. REPLACED POWER BAT T PACK AT DOOR L3 (M33406) AND PERFORMED INSTALLATION TEST WAS N ORMAL, PER AMM 33-51-06-960-802 REV.100.SDR CALA2024020800360Battery Pack · dischargedDOOR L2 EMERGENCY POWER PACK (M33096) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES, REPLACED POWER BAT T PACK AT DOOR L2 (M33096) AND PERFORMED INSTALLATION TEST WAS NORMAL AS PER AMM 33-51-06-960-802 REV.100.SDR CALA2024020800359Battery Pack · dischargedDOOR R2 EMERGENCY POWER PACK (M33098) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES. REPLACED THE M3309 8 BATT PACK AND TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 RE V.100.SDR CALA2024020800358Battery Pack · dischargedDOOR L3 EMERGENCY POWER PACK (M33400) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES. REPLACED DOOR L3 EMERGENCY POWER PACK (M33400) AND PERFORMED THE INSTALLATION TES T, THE RESULT FOUND NORMAL PER AMM 33-51-06-960-802 REV.100.SDR CALA2024020800357Battery Pack · dischargedDOOR L1 EMERGENCY POWER PACK (M33424) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES. REF HAECO NR NO.94786 08. REPLACED DOOR L1 E MERGENCY POWER PACK (M33424) AND PERFORMED THE INSTALLATION TEST THE RESULT FOUND NORMAL AS PER AMM 33-51SDR CALA2024020800356Battery Pack · dischargedDOOR R4 EMERGENCY POWER PACK (M33408) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES. REF HAECO NR NO.94786 58. REPLACED THE M3340 8 BATTERY PACK AND TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV.100.SDR CALA2024020800355Battery Pack · dischargedDOOR L2 EMERGENCY POWER PACK (M33099) CAPACITY CHECK FOUND CAN''T STAYED EMERGENCY LIGHTS ON FOR 15 MINUTES. REF HAECO NR NO.94786 10 - SPEC NO.B777-33-3-7019. REPLACED DOOR L2 EMERGENCY POWER PACK (M33099) AND PERFORMED THE INSTALLATION TES T, THE RESULT FOSDR CALA2024020700347Battery Pack · dischargedM/D R3 DOOR 1EA EMER LT POWER PACK(M33401) FOUND LOW CAPACITY REF HAECO NON-ROUTINE NO:9475937. SPEC NO.B777-33-3-7019. REPLACED EMER LT BATTERY PACK AND CARRIED OUT TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 100.SDR CALA2024020700346Battery Pack · dischargedM/D L3 DOOR 1EA EMER LT POWER PACK(M33400)FOUND LOW CAPACITY REF HAECO NON-ROUTINE NO:9475935 - REPLACED EMER LT BATTERY PACK AND CARRI ED OUT TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 100.SDR CALA2024020700345Battery Pack · dischargedM/D R3 DOOR 1EA EMER LT POWER PACK(M33404) FOUND LOW CAPACITY REF HAECO NON-ROUTINE NO:9475936 SPEC NO.B777-33-3-7019. REPLACED EMER LT BATTERY PACK AND CARRI ED OUT TEST FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 100.SDR CALA2024020700348Pressure Deck · crackedSUPPORT TASK : AD 2001-18-09, EA 5300-01502 REV A OP 001 - 1EA CRACK FOUND ON HORIZONTAL PRESSURE DECK WEB BETWEEN STA 1287 AND 1308, LBL 18.3 AND 25.7. TRANSFER REF.NON-ROUTINE HX NRC WO.2707022. HORIZONTAL PRESSURE DECK WEB BETWEEN STA 1287 AND 1308 LBL 18.3SDR CALA2024020500333Charger · failedB777-33-3-7019 EMER LT BATTERY PACK EQ# M33096 (LH DR2 FWD) CHARGER FOUND CANNOT CHARGE THE BATTERY. TRANSFER REF.NON-ROUTINE HX NRC WO.2685800. DR L2 EMER LIGHT BATTERY CHARGER M33096 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2024020500332Charger · failedB777-33-3-7019, DR R3 M33401 EMER LIGHT BATTERY CHARGER TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2681729. DR R3 M33401 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2024020500331Battery · failedSUPPORT TASK - DR R1 EMER LIGHT BATTERY M33094 TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2839546. DR R1 EMER LIGHT BATTERY M33094 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2024020500330Battery · failedSUPPORT TASK - DR R4 EMER LIGHT BATTERY M33408 TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2839520. DR R4 EMER LIGHT BATTERY M33408 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2024020500329Battery · failedSUPPORT TASK - DR L2 EMER LIGHT BATTERY M33096 TEST FAIL. TRANSFER REF.NON-ROUTINE HX NRC WO.2839504. DR L2 EMER LIGHT BATTERY M33096 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2024021500432Oil System · leakingACFT ABORT TAKEOFF FOUND LH ENGINE OIL QTY DROPPED TO 5 QTS, ACFT RETURN TO GATE FOUND LARGE ENGINE OIL LEAKAGE THE LH ENGINE OIL LEAKING PICTURE ATTACHED. FLAGGING SDR REFER PREVIOUS WORK DONE AND L7040780. NO.1 ENGINE REPLACEMENT COMPLETED. LH PACK SYSTEM COSDR CALA2024020500322Skin · crackedEA 5300-01986 REV A OP.001 ( AD 2008- 16-12 ) FX SKIN STA 2195.75 STR 6L-7L 1EA CRACK FOUND NOT MORE THAN 1 INCH CREATE OP.007 FOR REPAIR , TASK TRANSFER TO WO.2724398. FUSELAGE SKIN REPAIRED AS PER EA5300-01986 REV A OP007 AND ECRA 5385-01016 REV - JUST AT SDR CALA2024020700351Power Supply · inoperativeEMERGENCY EXIT LIGHTING SYSTEM OPERATIONAL CHECK {B777-33-3-7031} - DOOR 3 AFT EMERGENCY EXIT SIGN INOP NEED MORE GROUND TIME TO WORK THE PROBLEM MEL 3351A REJECTING UPDATE PART INFO. RELAMPED NO HELP, NEED FURTHER T/S. REMOVED AND REPLACED POWER SUPPLY M33405SDR CALA2024020700350Power Supply · inoperativeEMERGENCY LIGHTS OPERATIONAL CHECK {B777-33-3-7030} - DOOR 3 LEFT EXTERIOR EMERGENCY LIGHT INOP NEED MORE GROUND TIME TO WORK THE PROBLEM MEL 3351N REJECTING DAYLIGHT OPS ONLY RELAMPED NO HELP, NEED DOOR 3 LEFT EXTERNAL EMERGENCY LIGHT UPDATE PART INFO. ASSEMBSDR CALA2024020300309Filter · odorSMOKE AND FUMES IN COCKP IT AND CABIN IN FLIGHT DUE TO SMOKE /ODOR FOLLOW AMM 05-51-58-800-801-C3 SMOKE/ODOR IN THE FLIGHT DECK/CABIN - CONDITIONAL INSPECTION UNLOCKED FOR CLEARING AFTER INSPECTION IS DONE. HKG REPORTS SOURCE OF SMELL IS APU, SEPARATE LP WILL SDR CALA2024020500334Skin · damagedSUPPORT TASK TAR - SINCE OF AAI REQUIREMENT, R1 PASSENGER DOOR LOWER EDGE FOUND A NO RECORD EXISTING DOUBLER. PLEASE CONTACT UA ENGINEERING TO FIND THE PREVIOUS REPAIR RECORD OR ADVISE FURTHER ACTION. TRANSFER REF.NON-ROUTINE HX NRC WO.2692138 AND R1 PASSENGE
Back to Boeing 777-222