Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2024012500227Monitor · smokeSEAT 28A IFE SCREEN SMOKING. SMOKESTOPPED W/ IFE PASS SW OFF.SC REEN HOT REMOVED MONITOR AT SEAT #28A. PERFORMED VISUAL INSPECTION OF F824599. HARNESS BOTH CONNECTORS ARE IN GOOD CONDITION. NO BURNING SIGN FOUND. REPLACED MONITOR IAW AMM 44-25-04. OPS CHECK GOSDR CALA2024012300203Charger · no testB777-33-3-7019 DR L3 M33400 EMER LT BATT CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2600317 DR L3 M33400 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06 .SDR CALA2024012300202Battery Pack · no testB777-33-3-7019 L3 DR M33405 EMER LT BATT DEEP-CYC PACK CAPACITY CHK FAIL TRANSFER REF NON - ROUTINE WO.2600255 DR L3 M33405 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024012300201Battery Pack · no testB777-33-3-7019 R2 DR M33098 EMER LT BATT DEEP-CYC PACK CAPACITY CHK FAIL TRANSFER REF NON - ROUTINE WO.2600305 DR R2 M33098 EMER LT REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2024012300200Battery Pack · no testB777-33-3-7019 L3 DR M33406 EMER LT BATT TEST FAIL TRANSFER REF NON - ROUTINE WO.2600109 DR L3 M33406 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024012300199Battery Pack · no testB777-33-3-7019 L3 DR M33400 BATT DEEP-CYC PACK CAPACITY FAIL TRANSFER REF NON - ROUTINE WO.2600244 DR L3 M33400 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2024012300198Battery Pack · no testB777-33-3-7019 L2 DR M33096 EMER LT BATT DEEP-CYC PACK CAPACITY CHK FAIL TRANSFER REF NON - ROUTINE WO.2600311 DR L2 M33096 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024012300197Charger · no testB777-33-3-7019 DR R2 M33098 EMER LT BATT CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2599975 DR R2 M33098 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024012300196Charger · no testB777-33-3-7019 DR L4 EMER LT BATT CHARGER M33407 TEST FAIL TRANSFER REF NON - ROUTINE WO.2572027 DR L4 M33407 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024012300195Charger · no testB777-33-3-7019 DR L3 M33405 EMER LT BATT CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2599966 DR L3 M33405 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024012300194Battery Pack · no testSUPPORT TASK - DR L4 EMER LT BATT M33407 TEST FAIL. TRANSFER REF NON - ROUTINE WO.2572051 AND DR L4 M33407 EMER LT BATT REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024012300193Battery Pack · no testB777-33-3-7019 DR R2 M33097 EMER LT BATT TEST FAIL. TRANSFER REF NON - ROUTINE WO.2600103 DR R2 M33097 EMER LT BETTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2024012300192Charger · no testEMERGENCY LIGHT BATTERY CHARGER TEST FAIL TRANSFER REF NON - ROUTINE WO.2599986 EMER LT BATT CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06SDR CALA2024011700134Transceiver · faultedWXR SYS EICAS STATUS WXR DISPLAY IS NOT PRESENT WHEN WXR SELECTED ON EFIS CONTROL PAN EL. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 3444001 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: WXR TRANSCEIVER (LEFT) CMC MSG# 3444032 FLIGHT SSDR CALA2024011500106Unknown · unknownEXAUST SMELL IN FLDK STARDED DURING DESCEND PASSINGF FL240. RAN EACH PACK OFF OF EACH ENGINE ONE AT A TIME FOR 5 MINUTES EACH. NO SMELL NOTED IN FLT DECK OR CABIN. ALSO NO SMELL OFF OF APU SUPPLYING PACKS. OIL CONSUMPTION LOW ON BOTH ENGINES AND ENGINES ARRIVSDR CALA2024011700123Charger · no testB777-33-3-7031 CABIN DOOR R3 EMER LT PWR SUPPLY M33401 OPERATIONAL TEST FAIL. WORK TRANSFER NON ROUTINE WO.2732904. CABIN DOOR R3 EMER LT PWR SUPPLY M33401 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06.SDR CALA2024011700122Charger · no testCABIN DOOR R3 EMER LT PWR SUPPLY M33404 OPERATIONAL TEST FAIL. WORK TRANSFER NON ROUTINE WO.2732906 AND CABIN DOOR R3 EMER LT PWR SUPPLY M33404 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06.SDR CALA2024012900241Skin · deformedSUPPORT TASK - AFT CARGO COMPT DOOR AFT LOWER CORNER EXISTING REPAIRED DOUBLER FOUND DEFORM TRANSFER REF HXWO 2713494 AND AFT CARGO COMPT DOOR AFT LOWER CORNER REPAIRED AS PER SRM52-30-01-2R17 REPAIR 17 FIG.202 , ATTACH FORM 44-0008 WORKSHEET ITEM 1 TO 20.SDR CALA2024011500116Control Valve · failedRT PACK FAILED IN FLIGHT. AT TOMC REQUEST BOTH UPPER AND LOWER R/H PACK FLOW CONTROL VALVES REPLACED, IAW AMM 21-51-01 AND 21-51-02 REV 99. LOG UPDATED FOR ROTABLE PARTS CHANGE. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1404926 SN OFF 0022 TT # 1226861 SN OFF SDR CALA2024011200098Battery Pack · dischargedEMERGENCY LIGHTS BATTERY PACK M33424 AT DR L1 REPLACED AND INSTALLATION TEST CARRIED RESULT WITH NORMAL AS PER AMM 33-51-06. WORK TRANSFER NON ROUTINE WO.2612903. EMERGENCY LIGHTS BATTERY PACK M33424 AT DR L1 REPLACED AND INSTALLATION TEST CARRIED OUT RESULT SDR CALA2024011200094Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK (M33408) AT DR 4R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612915. EMERGENCY LIGHTS BATTERY PACK(M33408) AT DR 4R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06SDR CALA2024011200092Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK M33099 AT DR 2L FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612909. EMERGENCY LIGHTS BATTERY PACK M33099 AT DR 2L REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. SDR CALA2024011200090Battery Pack · dischargedB777-33-3-7019 EMERGENCY LIGHTS BATTERY PACK (M33097) AT DR 2R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612923. EMERGENCY LT BATTERY PACK (M33097) AT DR 2R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. ISDR CALA2024011200088Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK (M33401)AT DR 3R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612917. EMERGENCY LIGHTS BATTERY PACK(M33401) AT DR 3R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. SDR CALA2024011200096Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK AT LLAR FOUND CAPACITY CHECK FAIL.WORK TRANSFER NON ROUTINE WO.2612901 AND ORIGINATED BY EMP V920586. EMERGENCY LIGHTS BATTERY PACK M023 AT LLAR REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PERSDR CALA2024020500328Coupling · leakingWATER COMIMG OUT OF ALL FWD BELLY DRAINS PARTIALLY REMOVED SIDEWALL PANEL IN FWD CARGO LH SIDE FOR ACCESS R & R BOTH PACKINGS AND COUPLER AT WATER LEAK IRW 38-10-01. LEAK ICE STILL REMAINS IN FWD CARGO BILGE. NEEDS MELTED FOR DRAIN. TO WATER LEAK. PARTS USED:SDR CALA2024011700127Skin · crackedSUPPORT TASK - EA 5310-07557 OP 002 - 1EA CRACK FOUND ON LH UNDERWING LONGERON FTG FX SKIN FASTENER HOLE, CRACK RUNNING TO AFT DIRECTION APPROX 0.125" IN DEPTH STARTING FROM I/B EDGE TRANSFER REF NON - ROUTINE WO.2622006 AND ORIG BY V924734 RON DOUBLER INSTALLSDR CALA2024011000073Tube · crackedENG EEC MODE L ON TAKE OFF ,LOW SPEED RTO. ''ENG EEC MODE L'' STATUS MSG ERASED DURING MAINT EVALUATION- ASSOCIATED FAULT ''EPR P4.95 MANIFOLD...'' NEEDS FURTHER T-S. ADD FAULT: 77-61121 ADD PICS FOR: "ENG PRESS RATIO (EPR) (L ENG) P4.95 MANIFOLD IS BLOCKED ORSDR CALA2024011000075Duct · damagedBLEED LOSS BODY EICAS ON TAKEOFF ROLL. FOUND BLOWN PNEUMATIC DUCT IN THE LH MAIN WHEEL WELL, SEE ATTACHED IMAGE. MINIMUM REQUIRED PARTS HIGHLIGHTED, UNTIL FURTHER EVALUATION IS ACP. INITIAL EVALUATION PARTS INFO ADDED. REF IPC 29-11-16-01 ITEMS 100 AND 105, ASDR CALA2024010400032Battery · inoperativeCABIN GALLEY 2 AND GALLEY 3 MOUNTED EMERGENCY LIGHTS FAILED TO OPERATION REF HAECO NR NO.9474380. CABIN L2 DOOR HEADER EMERGENCY LIGHT BATTERY M33096 REPLACED AND INSTALLATION TEST CARRIED OUT,RESULT NORMAL REF TO AMM 33-51-06-960-802 REV.99.SDR CALA2024010400031Battery · inoperativeCABIN R4 DOOR EXIT SIGN AND AISLE EXIT SIGN EMERGENCY LIGHTS FAILED TO OPERATE. CABIN R4 DOOR HEAD ER EMERGENCY LIGHT BATTERY M33408 REPLACED AND INSTALLATION TEST CARRIED OUT REUSLT NORMAL REF TO AMM 33-51-06-960-802 REV.99.SDR CALA2024010400030Battery · inoperativeCABIN L4 DOOR EXIT SIGN AND GALLEY 9 MOUNTED EMERGENCY LIGHTS FA ILEDTO OPERATION REF HAECO NR NO.9474382. L4 DOOR HEADER EMERGENCY LIGHT BATTERY M33407 REPLACED AND INSTALLATION TEST CARRIED OUT,RESULT NORMAL REF TO AMM 33-51-06-960-802 REV.99.SDR CALA2024010400029Battery · inoperativeCABIN L2 DOOR EXIT SIGN AND AISLE EXIT SIGN BATTERY CAPACITY CHK FAILED REF HAECO NR NO.9474383 - ORIGINATED BY EMP V905376, SPEC NO.B777-33-3-7019, CAB L2 DOOR HEADER EMERGENCY LIGHT BATTERY M33099 REPLACED AND INSTALLATION TEST CARRIED OUT, RESULT NORMAL REFSDR CALA2023122603724Circuit Card · failedAI CARD EICAS STATUS WING ANTI-ICE (WAI) CONTROL CARD FAILURE. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 3018893 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: ARINC SIGNAL GATEWAY (L EFT), RSCF CARD, ASSY, AIR OFF 27-3011-9-0001 0122 SDR CALA2023122103708Battery Pack · inoperativeCABIN L3 DOOR EMERGENCY EXIT SIGN BATTERY PACK CAPACITY CHECK FAILED REF HAECO NON-ROUTINE NO.:9474247, CABIN L3 DOOR EMERGENCY EXIT SIGN BATTERY M33406 REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL AS PER AMM 33-51-06-960-802 REV99.SDR CALA2023122003696Battery · inoperativeLLAR EMERGENCY LIGHT BATTERY PACK FOUND INOP DURING TEST THE BACKUP LIGHTS. REPLACED AND INSTALLATION TEST OF LLAR EMERGENCY LIGHT BATTERY PERFORMED,RESULT NORMAL,LLAR BACK UP LIGHT TEST CARRIED OUT RESULT NORMAL AS PER AMM 33-29-01-600-801,33-51-06-960-802 RSDR CALA2023122003695Battery · inoperativeLLAR EMERGENCY LIGHT BATTERY PACK FOUND INOP DURING TEST THE BACKUP LIGHTS REF HAECO NON-ROUTINE NO.:9474241, REPLACED AND INSTALLATION TEST OF LLAR EMERGENCY LIGHT BATTERY PERFORMED, RESULT NORMAL, LLAR BACK UP LIGHT TEST CARRIED OUT RESULT NORMAL AS PER AMMSDR CALA2023122203721Steering Sys · warning messageTO CONFIG WANING ON TO MAIN GEAR STEERING MAIN GEAR STEERING EIC AS PERFORMED FIM TASK 32-52-TASK 805. MXG 32-63010. STEP E. STATUS MESSAGE CLEARED. CREW CONFIRMS SPEED BELOW 20KNTS AND RTO NEVER ENGAGED. PERFORMED FIM 32-52 TASK 805 FOR MSG 32-63010. MSG CLEASDR CALA2024012400218Longeron · crackedSUPPORT TASK - EA5310-07557 OP002 (AD2019-11-02) LH BS1035 UNDERWING LONGERON CTR SECTION FRONT SPAR LWR CHORD 2EA HOLE CRACK FOUND TRANSFER REF NON - ROUTINE WO.2618004 LH BS1035 UNDERWING LONGERON CTR SECTION FRONT SPAR LWR CHORD (2EA) HOLE CRACK REPAIRED ISDR CALA2023121503652Battery · failedCABIN R4 DOOR EMERGENCY LIGHT EXIT SIGN FAILED TO OPERATION REF HAECO NON-ROUTINE NO.:9474029, CABIN R4 DOOR EMERGENCY LIGHT BATTERY M33408 REPLACED AND INSTALLATION TEST PERFORMED AND RESULT NORMA L AS PER AMM 33-51-06-960-802 REV99SDR CALA2024012400220Skin · damagedSUPPORT TASK - EA 5100-02345 REV E OP19, CAB - L4 DOOR EXT SKIN DOUBLER FOUND AT AFT LOWER CORNER WITH NO REPAIR RECORD FOUND. TRANSFER REF NR HX WO.2571459 . EA5100-02345 REV E OP19 CAB - L4 DR EXT SKIN DOUBLER AT AFT LWR CORNER WITH NO REPAIR RECORD. THE LOCSDR CALA2024012400219Skin · damagedSUPPORT TASK - EA5100-02345 REV E OP19 CAB R2 DR EXT SKIN DOUBLER FOUND AT AFT LWR CORNER WITH NO RECORD FOUND TRANSFER REF NON - ROUTINE WO.2571519 EA5100-02345 REV E OP19 CAB - R2 DR EXT SKIN DOUBLER AT AFT LWR CONER WITH NO RECORD FOUND. THE LOCATION AREA SDR CALA2023121303640Pump · leakingL HYD QUANITY DROPPED TO 0 AFTER TAKEOFF FOUND LEFT HYDRAULIC MODULE IN PYLON WITH DISLOGED FILTER BOWL REMOVED LEFT ACMP PRESSURE AND CASE DRAIN FILTER MODULE AS PER AMM 29-11-40. FOUND NO DEBRI OR DPI''S EXTENDED. SWAPPED FITTINGS WITH NEW O RINGS ONTO REPLASDR CALA2023121303631Unknown · unknownACFT HAD AN RTO EVENT AT APPROX 130 KTS. ACFT ENCOUNTERED A LARGE BIRD STRIKE (HERON) INTO THE #2 ENGINE INLET DURING TAKEOFF ROLL. PARTIALLY CLEANED BIRD STRIKE FROM ENGINE BLADES AND EXIT GUIDE VANES. CONTINUE CLEAN-UP AS APPLICABLE. REF AMM 72-00-00-210-808SDR CALA2023121103620Idg · blockedR IDG OIL FILTER BLOCKED ON ELEC MAINT PAGE R ENG IDG FEEDER CABLE INSP C/O WITH REF TO R IDG REPLACEMENT AMM 24-11-01-400-801-001. INSP ACCOMPLISHED REF GMM IDT LIST 09-10-05 OIL SERVICE ACCOMPLISHED AT LHR FOR FLT 0901 ON 09 DEC 05:44:25 ENGINE 1: 00 ENGINESDR CALA2023120803614Battery Pack · dischargedCABIN R4 DOOR M33409 BATTERY CAPACITY TEST LESS THAN 15 MINUTES REF TO HAECO NON-ROUTINE NO.9473842, SPEC NO. B777-33-3-7019. R4 DOOR BATTER Y M33409 REPLACED, PERFORMED BATTERY PACK TEST FOUND ''NORMAL'' AS PER AMM 33-51-06-960-802 REV 99.SDR CALA2023120803612Battery Pack · dischargedBATTERY CAPACITY TEST FOUND R1 DOOR BATTERY M33094 OPERATE LESS THAN 15 MINUTES REF TO HAECO NON-ROUTINE NO.9470073, SPEC NO. B777-33-3-7019. - R1 DOOR BATTER Y M33094 REPLACED , PERFORMED BATTERY PACK TEST FOUND ''NORMAL'' A S PER AMM 33-51-06-960-802 REV 9SDR CALA2023120803607Battery Pack · no testCABIN ZONE A LH AISLE CEILING EMERGENCY LIGHT CAPACITY CHECK FAILED REF HAECO NR NO.9473844 - ORIGINATED BY EMP V905376, SPEC NO.B777-33-3-7011. PERFORMED BY EMP V905376, RII BY EMP V905342,CABIN L1 DOOR EMERGENCY LIGHT BATTERY M33424 REPLACED AND INSTALLATIONSDR CALA2023120803593Battery Pack · no testCABIN R3 DOOR EMERGENCY EXIT SIGN FAILED TO OPERATION REF HAECO NR NO.9473849 - ,SUPPORT TASK. CABIN R3 DOOR EMERGENCY EXIT SIGN BATTERY M33401 REPLACED & INSTALLATION TEST CARRIED OUT, RESULT NORMAL REF TO AMM 33-51-06-960-802 EV.99.SDR CALA2023120803617Battery Pack · dischargedBATTERY CAPACITY TEST FOUND R4 DOOR BATTERY M33408 OPERATE LESS THAN 15 MINUTES REF TO HAECO NON-ROUTINE NO.9473720, SPEC NO. B777-33-3-7019. R4 DOOR BATTER Y M33408 REPLACED AND CARRIED OUT NEW BATTERY PACK TEST FOUND ''N ORMAL'' AS PER AMM 33-51-06-960-80
Back to Boeing 777-222