Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2000UALA00691Screw · shearedAFTER REMOVAL OF MLG, DISCOVERED RETAINING SCREWS FOR UPR FWD TRUNNION HOUSING WEAR PLATE SHEARED OFF. *S/D* SCREWS SHEARED DUE TO MLG FORWARD TRUNNION UPPER HOUSING WEAR PLATE MOVEMENT. REPLACED FAILED WEAR PLATE RETENTION SCREWS AND ACCOMPLISHED SERVICE BSDR 2000UALA00717Floorbeam · crackedSTA 246 FORWARD STIFFENERS DAMAGED:TWO CRACKED IN THE RADIUS AT RBL 27.34 & LBL 7.88. TWO BUCKLED IN THE FREE FLANGE AT RBL 7.88 AND LBL 26.06. SUPPLEMENTAL DATA UPDATE, REPLACED STIFFENERS PER SRM 53-10-51.SDR 2000UALA00645Oven · dirtyF/A SMELLS RUBBER LIKE BURNING ODOR IN AFT GALLEY. GALLEY POWER OFF AND LIGHTS OFF IN THE AFT GALLEY AND SMELL WENT AWAY-CREW REPORTS. LOG STATES: FAINT SMELL OF SMOKE IN AFT GALLEY. *S/D* FOUND PLASTIC WRAP IN AFT GALLEY (R31) OVEN. REMOVED MELTED PLASTISDR 2000UALA00638Bleed Valve · failedFLT HAD RIGHT BLEED VALVE FAILURE. ALSO SATCOM MEL. DIVERTED ORD DUE TO COMBINED PROBLEMS. *S/D* ORIGINALLY, MAINT MSGS SHOWED THE PRSOV TO HAVE FAILED CLOSED, HPSOV FAILED OPENED & CLOSED (AT DIFFERENT TIMES), INTERMED. PRESSURE SENSOR FAILED & THE FAMV SDR 2000UALA00715Floorbeam · crackedSTA 246 FORWARD STIFFENERS DAMAGED:ONE CRACKED IN THE RADIUS AT RBL 7.88. THREE BUCKLED IN THE FREE FLANGE AT RBL 26.06 & 49.0 AND LBL 7.88. SUPPLEMENTAL DATA UPDATE, REPLACED CRACKED AND DISTORTED STIFFENERS PER SRM 53-10-51.SDR 2000UALA00637Radio · failedLT AND RT HF TRANSMIT OK BUT NO RECEPTION PER CREW. RTF *S/D* BOTH COUPLERS WERE REPLACED AND TESTED IN THE SHOP. THE RESULT WAS NO FAULT FOUND. ALSO REPLACED WAS THE AUDIO MANAGEMENT UNIT. THE RESULTS OF TESTING ON THIS UNIT ARE NOT YET KNOWN.SDR 2000UALA00636Idg · failedELEC GEN OFF RIGHT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF, AND ENGINE NOT SHUT DOWN. ADVISORY ELEC GEN R INOP. DUMPED FUEL. RTF. *S/D* ELEC GEN SYS R AND ELEC GEN OFF R EICAS MESSAGES WERE DISPLAYED. REPLACED RIGHT IDG.SDR 2000UALA00627Engine · malfunctionedLEFT ENGINE SLOW TO SPOOL BACK UP AT HIGH AND MIDDLE ALTITUDES NO NOTICABLE DIFFERENCE BETWEEN N1 AND EGT. *S/D* DURING STEP DESCENT, THROTTLES WERE ADVANCED ABOVE IDLE AND LEFT ENGINE ACCELERATED ABOUT 6 SECONDS SLOWER THAN RIGHT ENGINE, ACTIVATING RUDDER TSDR 2000UALA00604Battery · dischargedBATTERY CHARGER INDICATES RATE OF 50 AMPS, 29 VOLTS. BATTERY AND CHARGER REPLACED PRIOR TO FLT, CREW REPORTS. RTF. *S/D* THE MAIN BATTERY AND BATTERY CHARGER WERE REPLACED. THE FINDING REPORT ON THE BATTERY IS NO FAULT FOUND. THE CHARGER WAS TESTED AND NSDR 2000UALA00603Coffeemaker · contaminatedF/A REPORTED A BURNING ODOR (PLASTIC LIKE) IN THE VICINITY OFDR4R AND DR2L. ODOR DISSIPATED PER CREW. PIECE OF PLASTIC STUCK ON HOTPLATE IN MID (DOOR 2) GALLEY. REMOVED SAID PLASTIC AND OP CHECKED HOT PLATE.SDR 2000UALA00716Floorbeam · crackedSTA 246 FLOORBEAM: THREE STIFFENERS BUCKLED IN THE FREE FLANGE AT RBL 7.88 & 26.06 AND LBL 7.88. MID-CHORD CRACKED AT RBL 43 ON THE AFT SIDE. SUPPLEMENTAL DATA UPDATE, REPLACED DISTORTED STIFFENERS PER SRM 53-10-51. REPAIRED CRACKED CHORD ANGLE PER SRM 53-10SDR 2000UALA00602Check Valve · stuckNR 1 ENGINE IFSD AT FL300. ENGINE STALL REPORTED WITH SURGING. FLAMES OBSERVED BY FA''S FROM FRONT AND REAR OF ENGINE. DIVERTED BOS. *S/D* ENGINE WAS REMOVED. FOUND AND REPLACED FAILED INTERMEDIATE PRESSURE CHECK VALVE IN PNEUMATIC SYSTEM LOCATED AT 11 OSDR 2000UALA00598Switch · failedEMERGENCY EXIT LIGHTS CAME ON EN ROUTE FOR ABOUT 2 MIN ON THEIR OWN. OPERATED FLIGHT DECK EMERGENCY LIGHT SWITCH, LIGHTS CAME ON AND TURNED OFF NORMALLY. UNABLE TO DUPLICATE FAULT.SDR 2000UALA00599Light · inoperativeEMERGENCY LIGHTS AT DOOR 1L ARE INOP. SECURED CONNECTOR D3101P, EMERGENCY LIGHTS CHECK GOOD.SDR 2000UALA00588Window · failedWINDSHIELD AT 1R SHATTERED. DIVERTED DEN. *S/D* UAL COMPONENT ENGINEER EVALUATED DISCREPANT WINDOW IN THE SHOP. THE UPPER INNER BUS BAR (ANTI-FOG LAYER) WAS SEVERELY DETERIORATED ALONG THE FORWARD EDGE WHERE EVIDENCE OF DELAMINATION ALONG THE STRUCTURAL PSDR 2000UALA00584Door · stuckDOOR 2L STUCK 2 INCHES FROM AIRCRAFT WITH BOTH INSIDE AND OUTSIDE SHOWING IN THE LOCKED POSITION. *S/D* CAUSE DUE TO DOOR LOWERED OUTSIDE AIRCRAFT WHEN CLOSING. ACCOMPLISHED INSPECTION OF DOOR 2L. NO DEFECTS FOUND. DOOR OPERATION CHECKS NORMAL.SDR 2000UALA00586Tube · leakingMR25716-505, (P/N 62773-317), EVACUATION SLIDE/RAFT DOOR 3 LT FAILED AIR RETENTION TEST DURING ROUTINE SHOP OVERHAUL. UNIT HAS A SEAM LEAK IN THE LOWER TUBE OF THE INFLATABLE. PROBABLE CAUSE OF THE SEAM LEAK WAS A MANUFACTURING DEFECT. LOWER TUBE HAD A WRINSDR 2000UALA00568Indicator · malfunctionedDURING CLIMBOUT-PASSING 15,000-BOTH ALTIMETER INDICATIONS ON THE PFD''S TURNED AMBER IN COLOR AND SURROUNDED BY AMBER BOX. DIVERTED IAD. *S/D* PER 777 FLIGHT MANUAL PAGE 19-63 FOR THE INFORMATION ABOUT THE BAROMETRIC SETTING THE FOLLOWING IS QUOTED THE DISSDR 2000UALA00566Idg · failedLT IDG DISCONNECTED ON T-O ROLL. DUMPED FUEL. RETURNED TO FIELD. *S/D* EICAS ELEC GEN SYS L WAS DISPLAYED WITH ASSOCIATED MAINTENANCE MESSAGES 24-30031 (GENERATOR CONTROL UNIT (L) HAS AN INTERNAL FAULT) AND 24-31611 (INTEGRATED DRIVE GENERATOR (L) EXCITER SDR 2000UALA00565Acm · seizedRTF DUE TO DUAL A/C PACK FAILURE. *S/D* THE LT PACK ACM WAS FOUND SEIZED AND WAS REPLACED. THE RT PACK LOW LIMIT VALVE (P/N 810214-1, S/N UA00177654) WAS REPLACED DUE TO RT CONDENSER INLET TEMP SENSORS MESSAGE. AFTER PARTS REPLACEMENT, A/C RETURNED TO REVESDR 2000UALA00572Power Supply · inoperativeEMERGENCY LIGHTS IN FRONT HALF OF COACH INOP. REPLACED POWER SUPPLY AND BATTERY, OPS CK OK.SDR 2000UALA00685Floorbeam · damagedSTATION 246 AFT UPPER CHORD AND AFT UPPER CHANNEL CRACKED. STATION 246 FLOORBEAM FWD VERTICAL STIFFENER IS BENT. ALSO COCKPIT FLOOR SUPPORT IS CRACKED AT STATION 244 AT ATTACH AREA FOR STATION 246 FLOORBEAM STIFFENER. *S/D* REPAIRED PER SRM 53-10-51.SDR 2000UALA00545Sensor · dirtyAFTER TAKEOFF CREW HEARD LOUD THUMP SOUND AND DOOR FWD CARGO EICAS MSG DISPLAYED. DOOR SYNOPTIC PG AND DOOR SHOWED UNLATCHED. CREW ALSO REPORTED LOW FREQ VIBRATION DURING CLIMBOUT. RTF SEA. *S/D* CALLED OUT TO ACCOMPLISH INSPECTION OF WIRING, SENSORS, ANDSDR 2000UALA00540Acm · seizedJUST PRIOR TO LEVEL-OFF FL370 GOT BURNING ODOR IN THE FLIGHT DECK. CABIN TEMP ROSE TO 80+ DEGREES. *S/D* LT ACM FAILED AND WAS REPLACED. AIRCRAFT WENT BACK TO REVENUE SERVICE WITHOUT FURTHER INCIDENT. THE BURNING ODOR WAS THE SMELL PRODUCED BY THE ACM ASSDR 2000UALA00532Engine · malfunctionedPER CREW, RT ENG NOT PRODUCING COMMANDED THRUST. EPR N1 CAUTION. MOMENTARY RPM LOSS. *S/D* DURING DESCENT THRU 19,000 FT, THROTTLES WERE ADVANCED, RT ENG ACCELERATED SLOWER THAN THE LEFT TAKING SLIGHTLY MORE THAN 15 SEC TO RESPOND, EICAS ANNUNCIATED ENG THSDR 2000UALA00525Transducer · malfunctionedCREW LOW O2 MESSAGE. DIVERTED DEN. *S/D* CREW OXYGEN CYLINDER PRESSURE WAS NORMAL 1700 PSI. FOUND THE CAUSE OF THE PROBLEM TO BE THE PRESSURE TRANSDUCER. TRANSDUCER WAS REPLACED SEPT. 05, 2000. OPERATIONAL CHECK WAS GOOD.SDR 2000UALA00505Engine · malfunctionedN1 INDICATION: ERRATIC WHEN N1 IS ABOVE 9 PERCENT, RT ENGINE. N1 FLUCTUATIONS AFTER T/O. AIR COND PACKS SURGING SOUNDS, SHORTLY AFTER NR 2 ENG. EPR AND N1 STARTED FLUCTUATING NR 2 EPR +- . 07 TO 08 EPR NR 2 N1,+- .3 TO .4. *S/D* AFTER THE HPSOV WAS INOP IN SDR 2000UALA00491Battery · odorELECTRICAL ODOR OF SHORT DURATION SMELLED. MAIN BAT STATUS MSG AND BAT CHARGER MAIN SHOW ON SCREEN. *S/D* MAINTENENCE STATUS MESSAGE 24-13054 FOR MAIN BATTERY WAS DISPLAYED. REPLACED MAIN BATTERY AND ACCOMPLISHED OPERATION CHECK PER MM 24-30-00. VENDOR (ASDR 2000UALA00489Inverter · inoperativeROW 1E FWD AND AFT EMERGENCY PROXIMITY LIGHTS INOPERATIVE. *S/D* FOUND A WIRE PULLED OUT OF CONNECTOR FOR PROX LIGHT. WHILE SPLICING IN NEW WIRE, INVERTER WAS SHORTED OUT. AFTER SPLICE AND INVERTER REPLACEMENT, SYSTEM OPERATION NORMAL.SDR 2000UALA00481Generator · failedEN ROUTE SFO-FRA, CREW RECEIVED ADVISORY: BACKUP ELECTRICAL SYSTEM FAILURE. RETURNED TO SFO. *S/D* BOTH BACKUP GENERATORS FAILED. ORIGINAL GRIPES INDICATED INTERNAL ELECTRICAL FAULTS TO THE BACKUP GENERATORS. THEN, THE RIGHT BACKUP GENERATOR INDICATED A SDR 2000UALA00473Fire Loop · chafedDURING TAXI OUT, CREW REPORTED LEFT ENGINE FIRE LOOP 2 EICAS MESSAGE DISPLAYED. RETURNED TO BLOCKS. PREVIOUS HISTORY. *S/D* WIRE HARNESS ASSEMBLY 286W0656-002 WAS FOUND TO HAVE CHAFED INSULATION IN NUMEROUS SPOTS. ONE AREA ADJACENT TO WHERE THE SHIELDEDSDR 2000UALA00472Blade · fracturedEN ROUTE NRT-BKK, FLIGHT REPORTED NR 1 ENGINE COMPRESSOR STALL WITH MAXIMUM EGT OF 714. ENGINE WAS SHUT DOWN. AIRCRAFT DIVERTED TO TPE. *S/D* HIGH PRESSURE TURBINE FIRST STAGE BLADE FRACTURED IN THE AIRFOIL JUST ABOVE THE PLATFORM. FRACTURE WAS CAUSED BYSDR 2000UALA00461Acm · seizedEN ROUTE DEN-IAD, CREW RECEIVED EICAS MESSAGE PACK MODE L AND REPORT OF SMOKE IN CABIN. NR 1 AIR CONDITIONING PACK AUTO SHUTDOWN AND SMOKE DISSIPATED. AIRCRAFT RETURNED TO DEN. *S/D* PACK MODE L MESSAGE WAS DUE TO LT AIR CYCLE MACHINE SEIZING. AS THE ACM SDR 2000UALA00451Connector · shortedEN ROUTE IAD-MUC, ON CLIMBOUT, CREW RECEIVED ADVISORY MESSAGE INDICATING LEFT INTEGRATED DRIVE GENERATOR HAD DISCONNECTED. UNABLE TO RESET. AIRCRAFT RETURNED TO IAD DUE TO WEATHER EN ROUTE FORECAST. *S/D* ON THE IDG (INTERGRATED DRIVE GENERATOR), CONNECTORSDR 2000UALA00450Slide · leakingDURING ROUTINE SHOP OVERHAUL, DOOR 1 LEFT HAND SLIDE RAFT (P/N: 62771-117, S/N 0234) FAILED AIR RETENTION TEST. FOUND SEAM LEAK IN THE BOTTOM TUBE. LEAK IS IN RIGHT HAND DOG LEG TUBE FLANGE TO LOWER MAIN TUBE. SLIDE/RAFT (P/N: 62421-109, S/N 0234) SENT TO VSDR 2000UALA00445Brake · overheatedUPON ARRIVAL AT DEN, HOT BRAKES, SMALL FLAMES AND SOME SMOKE REPORTED AT OUTBOARD WHEELS ON RIGHT MAIN LANDING GEAR. FLAMES SELF-EXTINGUISHED WITH NO DAMAGE TO AIRCRAFT. *S/D* UNABLE TO DETERMINE ANY DEFINITIVE CAUSE. LT AND RT MAIN LANDING GEAR WHEEL AND SDR 2000UALA00429Structure · vibrationEN ROUTE IAD-FRA, PRONOUNCED VIBRATION IN FLOOR AT DOOR 2R. VIBRATION WORSE IN CLIMB, DIMINISHED AT LEVEL OFF. AIRCRAFT RETURNED TO FIELD. *S/D* MAINTENANCE CHECKED AIR CONDITIONING RAM AIR DOORS AND FOUND CONDITION ACCEPTABLE. ALSO ENGINEERING CALLED FORSDR 2000UALA00419Video Unit · overheatedAFTER DEPARTURE EXPERIENCED SMOKE IN CABIN FROM ENTERTAINMENT SYSTEM UNDERSEAT ELECTRONIC UNIT AT SEAT 17AB. AIRCRAFT RETURNED TO FIELD. *S/D* FILTER CAPACITORS IN THE POWER SUPPLY FAILED CAUSING OVERHEAT DAMAGE TO THE CIRCUIT BOARD. THE VIDEO DISTRIBUTIONSDR 2000UALA00420Controller · intermittentAFTER DEPARTING IAD EN ROUTE TO LHR, CREW REPORTED LEFT AUTOTHROTTLE WOULD NOT ENGAGE. AIRCRAFT RETURNED TO IAD. *S/D* THE PRIMARY SUSPECTED PROBLEM WAS AN INTERMITTANT FAILURE OF THE AUTOPILOT MODE CONTROL PANEL (P/N:822-0195-102). ALSO CONTRIBUTING TO THSDR 2000UALA00406Valve · leakingDURING SHOP OVERHAUL DOOR 1LH SLIDE/RAFT ASSEMBLY (P/N: 62771-117, S/N: 0021) FAILED AIR RETENTION TEST. FOUND THE BOTTOM TUBE INFLATE/DEFLATE VALVE (P/N B51007-2) LEAKING. REPLACED VALVE AND UNIT PASSED AIR RETENTION CHECK.SDR 2000UALA00405Connector · failedEN ROUTE IAD-CDG, AIRCRAFT RETURN TO FIELD FOR LOSS OF RIGHT HAND DUCT PRESSURE AND STATUS MESSAGE TRIM AIR R. *S/D* FIM 36-22, TASK 801 ACCOMPLISHED. REPLACED MANIFOLD DUAL TEMPERATURE SENSOR (P/N:1150322-1), OPS CK GOOD. THE FAILED SENSOR HAS BEEN TESTESDR 2000UALA00369Slide · leakingDURING SHOP OVERHAUL DOOR 4 RT SLIDE/RAFT ASSEMBLY (P/N: 62774-402, S/N: 0222) FAILED AIR RETENTION TEST. THE INFLATABLE ASSEMBLY (62424-402) TOP TUBE ASPIRATOR FLAPPER VALVE AND ASPIRATOR FLANGE WERE FOUND LEAKING (ASPIRATOR P/N: 62510-101). UNIT RETURNED TSDR 2000UALA00352Skin · crackedMAJOR REPAIR: AIRCRAFT DAMAGE TO FUSELAGE SKIN ALONG BOTTOM OF AFT MANUAL LOADING PIT. FOUND AFT GOUGE THROUGH SKIN 8 INCHES LONG REQUIRING MAJOR REPAIR. *S/D* REPAIR ACCOMPLISHED USING AN ADAPTATION OF SRM 53-00-03 AND 53-00-01 IN ACCORDANCE WITH DEVIATIONSDR 2000UALA00338Connector · dirtyFLIGHT DEPARTED LHR WITH LEFT GENERATOR DEFERRED INOPERATIVE. SHORTLY AFTER DEPARTURE, RIGHT GENERATOR FAILED. RETURNED TO LHR. *S/D* THE FAULT ISOLATION CODE INDICATED A DIFFERENTIAL CURRENT FAULT. THE CAUSE WAS A VERY DIRTY CONNECTOR ON THE R-ENGINE CORSDR 2000UALA00332Oxygen Bottle · leakingEN ROUTE SFO-FRA, CREW REPORT CREW OXYGEN SHOWING 450 PSI. SHOULD READ 1250 PSI. DIVERTED TO BGR. *S/D* OXYGEN WAS SERVICED PER AMM 12-15-08. CHECKED COCKPIT OXYGEN MASK, NO LEAKS FOUND. ENGINEER ASSIGNED TROUBLESHOOTING TASK TO ACCOMPLISH FIM 35-11, TASSDR 2000UALA00317Transceiver · failedEN ROUTE SFO-OGG, NR 2 HF (HIGH FREQUENCY RADIO) FAILED. FLIGHT CONTINUED TO OGG. *S/D* THE NR 2 HF TRANSCEIVER WAS REPLACED TWICE, ONCE ON JUNE 7TH IN OGG AND AGAIN THE SAME DAY IN SFO. THE SYSTEM HAS OPERATED FOR 15 DAYS WITHOUT A SUBSEQUENT FAULT. BOTHSDR 2000UALA00324Floorbeam · crackedMAJOR REPAIR REPORTING: DURING ROUTINE MAINTENANCE A CRACK WAS FOUND IN ONE OF THE MID CHORD ANGLES (P/N:141W8519-1) ON THE MAIN DECK FLOORBEAM AT STATION 246, LBL 38.5. ACCOMPLISHED REPAIR PER BOEING STRUCTURAL REPAIR MANUAL 53-10-51, FIGURE 201, REPAIR TYPSDR 2000UALA00298Battery · inoperativeAFTER DEPARTURE LAX (LAX-LHR), CREW RECEIVED MESSAGE OF MAIN BATTERY FAILURE. AIRCRAFT RETURNED TO LAX. *S/D* BOTH THE MAIN BATTERY AND THE MAIN BATTERY CHARGER SHOWED MAINTENANCE MESSAGES SAYING THEY WERE DEFECTIVE. REPLACED BOTH THE MAIN BATTERY (263BA10SDR 2000UALA00269Tube · leakingDURING SHOP OVERHAUL, SLIDE/RAFT (P/N 62774-414), (S/N 0224), TOP TUBE FAILED AIR RETENTION TEST. FOUND A SEAM LEAK AT SEAM JOINT BETWEEN TOP ASPIRATOR TUBE AND MAIN TOP TUBE (P/N 62424-408). UNIT RETURNED TO VENDOR FOR WARRANTY REPAIR. UNIT WAS LAST OVERHASDR 2000UALA00268Tube · leakingDURING SHOP OVERHAUL, SLIDE/RAFT (P/N 62772-213), (S/N 0264), TOP TUBE FAILED AIR RETENTION TEST. FOUND SEAM LEAK IN TOP TUBE (P/N: 62422-207), 15 INCHES FROM TOP TUBE ASPIRATOR. UNIT RETURNED TO VENDOR FOR WARRANTY REPAIR. UNIT WAS LAST OVERHAULED BY VENDO
Back to Boeing 777-222