Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023111003330Battery Pack · failedB777-33-3-7019 - DOOR 4R EMER LIGHT BATT PACK (M33409) FAILED CAPACITY CHECK TRANSFER REF HXWO 2448095 AND ORIGINATED BY EMP V920570 DOOR 4R EMER LIGHT BATT PACK (M33409) REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 WORK ACCOMPLISHED BY MECHANIC V920569 AND SDR CALA2023111003328Battery Pack · failedB777-33-3-7019 - DOOR 3L EMER LIGHT BATT PACK (M33406) FAILED CAPACITY CHECK TRANSFER REF HXWO 2448088 AND ORIGINATED BY EMP V920570 DOOR 3L EMER LIGHT BATT PACK (M33456) REPLACED AND TEST NORMAL AS PER AMM33-51-06 WORK ACCOMPLISHED BY MECHANIC V920571 INSPECTSDR CALA2023120503546Frame · crackedB777-53-4-7120, DOOR L3 UPPER CORNER CUTOUT FOUND 1EA CRACK. TRANSFER REF. NON-ROUTINE HX NRC WO.2402832 AND FX NO.3 LH PED CUTOUT AFT UPPER CORNER AT STA 1546 AND S17L BEAR STRAP INTERIM REPAIRED AS PER EC/RA 5360-01746 REV- PART 1. ATTACHED FORM 44-0008 ITESDR CALA2023110303265Stringer · crackedM/D R/H STA265.5 STR27 FOUND CRACKED, REFER TO HAECO NON-ROUTINE NO. 9466730, ORIGINATED BY EMP V902600, SPEC NO. B777-25-3-7179. PERFORMED BY EMP V902600, RII BY EMP V905050, M/D R/H STA 265.5 STR 27 REPAIRED AS PER SRM 53-10-03-2R-5 REV.93, APPROVED AS A CATSDR CALA2023103003234Battery Pack · dischargedEMER LT BATTERY PACK AT DR 2R FOUND CAPACITY FUNCTION CHECK FAIL REF HX NR WO.2295789, ORIG BY V920586 EMER LT BATTERY PACK AT DR 2R REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2023103003232Battery Pack · dischargedEMER LT BATTERY PACK AT DR 3L FOUND CAPACITY FUNCTION CHECK FAIL REF HX NR WO.2295784, ORIG BY V920586 EMER LT BATTERY PACK AT DR 3L REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023103003230Battery Pack · dischargedEMER LT BATTERY PACK AT DR 4R FOUND CAPACITY FUNCTION CHECK FAIL (M33409) REF HX NR WO.2295764, ORIG BY V920586 EMER LT BATTERY PACK AT DR 4R REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 (M33409) ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023103003228Battery Pack · dischargedEMER LT BATTERY PACK AT DR 3R FOUND CAPACITY FUNCTION CHECK FAIL REF HX NR WO.2295839, EMER LT BATTERY PACK AT DR 3R REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2023103003226Battery Pack · dischargedEMER LT BATTERY PACK (M33099) AT DR 2L FOUND CAPACITY FUNCTIONAL CHECK FAIL REF HX NR WO.2295826, ORIG BY V920586 EMER LT BATTERY PACK AT DR 2L REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 (M33099)SDR CALA2023102703201Idg · overservicedELEC GEN DRIVE L EICAS ADVISORY LEFT IDG FAULT (LOW INTERNAL OIL PRESSURE). FIM TASK REF : 24-11 TASK 803 CMC MSG# 2431551 FLIGHT STATUS: L INTERMITTENCE CODE: M PH: CLIMB NARRATIVE: GENERATOR CONTROL UNIT (L) FOUND IDG OVERSERVICED AND DPI EXTENDED ON LEFT IDSDR CALA2023102503174Unknown · unknownDESCENDING OUT OF 12K SLIGHT BURNING SMELL ON FD AND FIRST CLASS SMOKE FORMS ATTACHED PERFORMED SMOKE/ODOR IN FLIGHTDECK/CABIN INSP REF AMM 05-51-58. SMELL DISSIPATED AS TROUBLE SHOOTING CONTINUED. COULD NOT DUPLICATE, NO DEFECTS NOTED.SDR CALA2023120603576Unknown · crackedSUPPORT TASK- EA5310-06900 REV.D OP 013 STEP 23.7 1EA CRACK FOUND LOWER CHORD AT 12 O''CLOCK POS (VIEW LOOKING AFT) APPROX 0.070" IN LENGTH. TRANSFER HX NR WO.2403473 AND . FX WING CENTER SECTION FRONT SPAR LH LOWER CHORD INTERIM REPAIRED AS PER EC/RA 5710-028SDR CALA2023120603573Unknown · crackedSUPPORT TASK- EA5310-06900 REV.D OP 014 STEP 23.7 1EA CRACK FOUND LOWER CHROD AT 11 O''CLOCK POS (VIEW LOOKING AFT) APPROX 0.050" IN LENGTH. TRANSFER XH WO.2403488 AND FX WING CENTER SECTION FRONT SPAR RH LOWER CHORD INTERIM REPAIRED AS PER EC/RA 5710-02844 RSDR CALA2023120603567Floor Support · crackedSUPPORT TASK- AD 2001-18-09, EA5300-01502 REV.A OP 001- HORIZONTAL PRESSURE DECK WEB CRACK FOUND, PLEASE RELEASE EA5300-01502 REV.OP 002. TRANSFER HX WO.2377581 AND. HORIZONTAL PRESSURE DECK WEB AT STA 1287-1308 BTW LBL18.30-25.70 AND LVL 39.70-46.30 PERMANENTSDR CALA2023102303148Panel · missingFOUND MISSING ACCESS PANEL 443CL ON ARRIVAL INTO DEN ON #2ENGINE INBOARD PYLON. PICTURE ADDED MISSING PANEL ADDRESSED,SEE LOG PAGE 5798939. FOUND ACESS PANEL 443CL ON #2 ENG INBRD STRUT MISSING ON SERVICE CHECK. REQUEST PANEL TO BE PUT ON CDL. PLACED ACESS PANSDR CALA2023101703090Gcu · unknownELEC BUS ISLN R EICAS ADVISORY RIGHT BUS TIE ISOLATION SWITCH OFF OR FAULT PREVENTING NORMAL BUS TIE OPERATION HAS OCCURRED. UNIT, GENERATOR OFF 27-2421-9-0001 0168 ON 27-2421-9-0001 0110 UNIT, REMOVED AND REPLACED APU GCU PER AMM 24-22-02. REPLACEMENT TEST SDR CALA2023100903004Battery Pack · dischargedFOUND CABIN L3 DOOR AREA EMERGENCY POWER SUPPLY M33400 BATTTERY LOW CAPACITY, REFER TO HAECO NR NO. 9464555, SPEC NO. B777-33-3- 7019. PERFORMED BY EMP V903250 IDT BY TA308, REPLACED THE CABIN L3 DOOR AREA EMERGENCY POWER SUPPLY M33400 BATTERY AND OPERATIONAL SDR CALA2023100903003Battery Pack · dischargedFOUND CABIN R3 DOOR AREA EMERGENCY POWER SUPPLY M33404 BATTERY LOW CAPACITY, REFER TO HAECO NR NO. 9464554, SPEC NO. B777-33-3- 7019. PERFORMED BY EMP V903250 IDT BY TA308, REPLACED THE CABIN R3 DOOR AREA EMERGENCY POWER SUPPLY M33404 BATTERY AND OPERATIONAL TSDR CALA2023100903002Battery Pack · dischargedFOUND CABIN L1 DOOR AREA M33093 EMERGENCY POWER SUPPLY BATTERY LOW CAPACITY, REFER TO HAECO NR NO. 9464549, SPEC NO. B777-33-3- 7019. PERFORMED BY EMP V903250 IDT BY TA308,REPLACED THE CABIN L1 DOOR AREA EMERGENCY POWER SUPPLY M33093 BATTERY AND OPERATIONAL TESDR CALA2023100903001Battery Pack · dischargedFOUND CABIN L4 DOOR AREA EMERGENCY POWER SUPPLY M33407 BATTERY LOW CAPACITY, REFER TO HAECO NR NO. 9464551, SPEC NO. B777-33-3- 7019. PERFORMED BY EMP V903250 IDT BY TA308, REPLACED THE CABIN L4 DOOR AREA EMERGENCY POWER SUPPLY M33407 BATTERY AND OPERATIONAL TSDR CALA2023100903000Battery Pack · dischargedFOUND CABIN R1 DOOR AREA EMERGENCY POWER SUPPLY M33094 BATTERY LOW CAPACITY, REFER TO HAECO NR NO. 9464547, SPEC NO. B777-33-3- 7019. PERFORMED BY EMP V903250 IDT BY TA308, REPLACED THE CABIN R1 DOOR AREA EMERGENCY POWER SUPPLY M33094 BATTERY AND OPERATIONAL TSDR CALA2023100902999Battery Pack · dischargedFOUND CABIN L2 DOOR AREA EMERGENCY POWER SUPPLY M33095 BATTERY LOW CAPACITY, REFER TO HAECO NR NO. 9464552, SPEC NO. B777-33-3- 7019. PERFORMED BY EMP V903250 IDT BT TA308, REPLACED THE CABIN L2 DOOR AREA EMERGENCY POWER SUPPLY M33095 BATTERY AND OPERATIONAL TSDR CALA2023100902998Battery Pack · dischargedFOUND CABIN R2 DOOR AREA EMERGENCY POWER SYPPLY M33097 BATTERY LOW CAPACITY, REFER TO HAECO NR NO. 9464553, SPEC NO. B777-33-3- 7019. PERFORMED BY EMP V903250 IDT BY TA308, REPLACED THE CABIN R2 DOOR AREA EMERGENCY POWER SUPPLY M33097 BATTERY REPLACED AND OPERSDR CALA2023100902996Stringer · crackedCAB STA 265.5 STR 27R STRINGER FOUND CRACK,REFER TO HAECO NR NO. 9464889, SPEC NO. B777-53-3-7111. CABIN STA 265.5 STR 27R STRINGER REPAIRED AS PER SRM 53-10-03-2R-5 REV 93.SDR CALA2023100602954Actuator · faultyMLG STEERING EICAS ADVISORY EITHER MLG AFT AXLE IS INDICATING- NOT LOCKED. LVL 1 FOR MLG STEERING CONTROL ACT RT IS UNSERVICEABLE, MSG 32-63020. MGSCU REPLACED. CONFIRMED STEERING ACT PINS NOT IN VIEW & SELECTOR LEVERS MOVED TO LOCKED POSITION. CB PULLED. SDR CALA2023092902922Engine · failed insp#1 ENGINE FAILED HUB INSPECTION EA 7231-02005 AS STATED ON CERIFICATE OF NONCONFORMANCE ADD PARTS DATA ROTABLE PARTS CHANGE WAS INDICATED - TT # 1604907 SN OFF 7025 ENGINE, (PW4077 OFF 26-7200-9-0001 7025 ON 26-7200-9-0001 7110 INSTALLED NEW ENGINE IN THE #1SDR CALA2023092202866Fan · brokenPER FLIGHT CREW, FLIGHT ATTENDANTS REPORTS ODOR IN THE CABIN ON CLIMB AFTER TAKE OFF. DISSIPATED AT CRUISE. FLIGHT ATTENDANT FEL T ILL. CREW ELECTED TO RETURN TO FIELD. ODOR SEEMED TO RETURN A N D GET STRONGER ON DECENT. SEVERAL ATTENDANTS AND PASSENGERS RE POSDR CALA2023092202845Access Door · missingPDA 2 FOUND ACESS PANEL 443CL ON #2 ENG INBRD STRUT MISSING ON SERVICE CHECK.REQUEST PANEL TO BE PUT ON CDL. PLACED ACESS PANEL 443CL ON CDL54B DISPATCH DESK: 91 NAME: SH DATE: 20-SEP-23- APPROVED FOR CDL 54B UPDATED PARTS NEEDED.SDR CALA2023092102840Control Unit · failedSPOILERS EICAS ADVISORY FAILURE OF ONE OR MORE SPOILER PAIRS. FLT CONTROL SYS STATUS AFTER LANDING. REF MX MSG 27-10504, 27-10505, 27-10506 & 27-10510. PERFORMED SPOILER SYSTEM TEST PER AMM TASK 27-61-00-740-801 ALL TESTS PASSED. NO SPOILER MSG. DUE TO MSG 27-SDR CALA2023092002835Panel · missingPDA 2 ON WALK AROUND FOUND MISSING PRESSURE RELIEF DOOR ON #2 PYLON PANEL 443CL) REF LOG #5789434 FOR MISSING #2 PYLON PRESSURE RELIEF DOOR PANEL # 443CL.APPLIED CDL 54B. PLACED PRESSURE RELIEF DOOR ON #2PYLON ON CDL(443CL) PLACED THE MISSING PANEL 443CL, ON CSDR CALA2023092002832Starter · intermittentFIRE ENG R IN FLT INTERMITTENTLY CONTACT TOMC FOR FURTHER DETAILS. ASSY REPLACED REF AMM 26-11-01-401. FIRE TEST PASSED AND STS MESSAGE CLEARED.SDR CALA2023091802810Battery Pack · failedDR 3L BATTERY PACK (M33406) CAPACITY CHECK FAIL REF HX NR WO.2248786, ORIG BY V920586. DR 3L BATTERY PACK (M33406) REPLACED AND OPERATION TEST RESULT NORMAL IAW AMM 33-51-06. ACCOMPLISHED BY MECH V920586, INSP V898561SDR CALA2023091802809Battery Pack · failedDR 4R BATTERY PACK (M33409) CAPACITY CHECK FAIL REF HX NR WO.2248777. DR 4R BATTERY PACK (M33409) REPLACED AND OPERATION TEST RESULT NORMAL IAW AMM 33-51-06. ACCOMPLISHED BY MECH V920586, INSP V898561.SDR CALA2023091402786Duct · brokenCABIN ALTITUDE EXCEEDED 10000 AT FL370. BOTH OUTFLOW VALVES CLOSED. BROKEN AND NOT SEATED. REF PICS. PARTS NIS IN EWR. PER CREW DEBRIEF, CABIN RATE RAISED TO 9500 AND AT 10000 GOT CABIN ALT WARNING, DONED O2 MASKS AND PERFORMED DECENT PER QRH. PASSENGER O2 MASSDR CALA2023090602723Battery · dischargedBATTERY PACK AT DR 3L CAPACITY CHECK FAILED REFER HX NR WO.2193562. EMER LT POWER PACK BATT M33405 REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2023090602722Battery · dischargedBATTERY PACK AT DR 3R CAPACITY CHECK FAILED REFER HX NR WO.2193564. EMER LT POWER PACK BATT M33406 REPLACED AND INSTALLATION TEST CA RRIED OUT RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2023090602721Unknown · faultyAPU EICAS STATUS APUC DETECTED FAULT THAT WOULD CAUSE AUTOMATIC SHUTDOWN OF APU IN UNATTENDED MODE OPERATION, OR COMPLETE LOSS OF APUC BUS ACTIVITY (BOTH L AND R 629) FOR 3 SECONDS AFTER THE APU MASTER CONTROL SWITCH HAS BEEN IN THE ON POSITION FOR TEN SECONDSSDR CALA2023090502712Feeder Cable · brokenENG GEN R TRIPPED/RESET TRIPPED/REMAINED OFF INOPERATIVE STICKER ADJACENT TO THE ASSOCIATED GEN CTRL SWITCH ON THE OVERHEAD ELECTRICAL PANEL APPLIED PER MEL. PERFORMED R ENG GENERATOR DISCONNECT PROCEDURE PER MEL 2411A SECTION B NOTE - R ENG UPPER TERMINAL BLOSDR CALA2023090602724Fuse · blownEMER SLIDE LT AT DR 4R FOUND INOP REFER HX NR WO.2193563. . POWER SUPPLY OF EMER SLIDE LT AT DR 4R REPLACED AND OPERATIONAL TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2023090402683Rub Strip · bentAFT CARGO , UPPER MIDDLE PROTECTIVE RUBSTRIP IS BROKEN & BENT. DAMAGE IS TO AFT CARGO CEILING LINER RUBSTRIP. AREA INSPECTED AND NO FURTHER DAMAGE NOTED. ACCOMPLISHED INTERIM REPAIR PART 1. OF ECRA 2552-01091 REV D. PERFORMED REMOVED AND REPLACED RUB STRIP INSDR CALA2023090602732Oven · fireMID GALLEY OVEN HAD A FIRE NOW EXTINGUISHED LOCKING LOG UNLOCKING TO CLEAR LOG NO FIRE OCCURRED. SMOKE CAME FROM SPILLED CHOCOLATE OVERFLOWING IN OVEN. CHOCOLATE COKED ON THE INSIDE OF OVEN. NO EXTERNAL DAMAGE TO GALLEY. FIRE EXTINGUISHER USED IN OVEN. OVEN NOSDR CALA2023083002663Lever · unknownREJECTED TAKEOFF AT 10 KNOTS DUE TO FAILURE OF LEFT ENG TO ACCEL ERATE 22-31-00, BOTH TEST PSSED AND NO AUTOTHROTTLE FAULTS. FLT CREW REPORT: WITH AUTOTHROTTLE ENGAGED BOTH THRUST LEVERS NOTE: AUTOTHOTTLE REPONDED NORMALLY WHEN TOGA SWITCH WAS ADVANCED NORMALLSDR CALA2023083002657Pump · low pressureHYD QTY LOW R EICAS ADVISORY RIGHT HYDRAULIC SYSTEM RESERVOIR QUANTITY LOW. QTY < .4 FIM TASK REF : 29-11 TASK 827 CMC MSG# 2910330 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: HYDRAULIC INTERFACE MOD ULE (HYDIM)(R) REMOVED AND REPLACED RH ESDR CALA2023082302624Engine · damagedRIGHT ENGINE EXCEEDED TEMP LIMITS ON TAKEOFF AFTER ROTATION. ENG 2 SHOWS ENG R EGT RED WITH MM 77-62122 DURING TAXI OUT. REF FIM TASK 71-05-00-810-833-N00.THE SUBJECT ENGINE HAD AN EXCEEDANCE DURING TAKEOFF WITH A PEAK EGT OF 701 DEGREES CELSIUS PER AHM EXCEEDSDR CALA2023082102594Battery Pack · dischargedRH DR 4 EXIT CUTOUT LIGHT INOP REF HX NR WO.2032415, ORIG BY V920591. RH DR 4 EXIT CUTOUT BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 ACCOMPLISHED BY MECH V920586, INSP V896992.SDR CALA2023082102593Battery Pack · dischargedLH DR 2 EMER PWR SUPPLY M33096 CAPACITY CHK FAIL REF HX NR WO.2032390, ORIG BY V920591. LH DR 2 EMER PWR SUPPLY BATTERY PACK M33096 REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023082102592Battery Pack · dischargedLH DR 3 EXIT CUTOUT LIGHT INOP REF HX NR WO.2032410, ORIG BY V920591 LH DR 3 EXIT CUTOUT BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023082102591Battery Pack · dischargedRH DR 3 EXIT CUTOUT LIGHT INOP REF HX NR WO.2032407, ORIG BY V920591 RH DR 3 EXIT CUTOUT BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023082102590Battery Pack · dischargedLLAR EMER PWR SUPPLY M023 CAPACITY CHK FAIL REF HX NR WO.2032401, ORIG BY V920591 LLAR EMER PWR SUPPLY BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023071402247Battery Pack · inoperativeLOG ENTRY FOR SDR REPORTING. EMERGENCY LIGHT BATTERY PACK M33401 INOP AT R3 DOOR. SEE ST ENGINEERING N/R 102919. BATTERY PACK M33401 REPLACED AT R3 DOOR ON ST ENGINEERING N/R 102919
Back to Boeing 777-222