Boeing 777-222
Service difficulty reports · 9,713
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025111011053Battery · dischargedFOUND THE M33094 BATTERY LOW CAPACITY. R1 DOOR EMERGENCY LIGHT POWER PACK LOW CAPACITY REPLACED AND TESTED OK. REPLACED THE M33094 BATTERY AND TEST OK AS PER AMM 33-51-06-960-802 REV 105.SDR CALA2025110911018Actuator · faultedDOOR FLIGHT LOCK 3L EICAS STATUS, NR 3 LEFT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SENS OR DISAGREEMENT. FOUND MX MESSAGES ON MAT NOT ACTIVE UPON ARRIVAL. RAN DOOR FLIGHT LOCK GROUND TEST ON MX MAT AND ALL DOORS LOCKED EXCEPT DOOR 3L. VERIFIED DOSDR CALA2025110510917Cover · puncturedPUNCTURE IN SLIDE RAFT COVER AT DOOR 4R. INTERIM REPAIR PER EC/RA 2560-03751 REV 0 PART 1 PERFORMED. INSPECTION PER PART 2 PERFORMED. NO FURTHER DISCREPANCIES NOTED. OK FOR DIP. OKAY TO CARRY FORWARD WITH AN INTERIM REPAIR ACCOMPLISHED ON THE R4 DOOR SLIDE BUSDR CALA2025110610934Battery · not reportedEMERGENCY POWER ASSIST SYSTEM (EPAS) 9 VOLT BACK-UP BATTERY INSTALLATION, INSTALLED SAFETY PINS DOOR 2R SLIDE PACK. REMOVED R2 DOOR SLIDE SAFETY PINS AND STOWED IN POUCH, IAW AMM 52-11-20. COMPLIED WITH REMOVAL AND STOWAGE OF DOOR 2R SAFETY PINS.SDR CALA2025110510923Wire · burnedMAINTENANCE MESSAGE 24-13063 POWER BUS AC GND SVCE SEC 1 BUS IN P320 IS NOT POWERED, PERFORMED A COMPLETE GROUND SERVICE BUSS TEST WITH NO ISSUES. PERFORMED TROUBLESHOOTING IAW FIM 2 4-51 TASK 805 REV 105 AND REPLACED WIRE W3241-0010-12 IAW SWP M 20-10-11 RESDR CALA2025110310846Battery Pack · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - 2R DOOR M33097 EMERGENCY POWER SUPPLY INOP REPLACED EMERGENCY BATTERY PACK, REF AMM 33-51-06-960-802. OPS CHECK GOOD.SDR CALA2025110310849Slide · partial deployON OPERATION OF L1 DOOR INTERRIOR HANDLE, TO INSTALL THE GIRT SAFETY RELEASE PIN. L1 SLIDE MATERIAL INADVERTENLY DEPLOYED. NO INFLATION. R & R L1 DOOR SLIDE PACK IAW MM 25-66-01-400-801. ACCOMPLISHED EMERGENCY POWER ASSIST SYSTEM (EPAS) RESERVOIR PRESSURE LSDR CALA2025110210801Battery Pack · no testCABIN L2 DOOR EXIT LIGHT AND EMERGENCY LIGHT INOPERATIVE. REPLACED THE CABIN L2 DOOR AREA M33096 EMERGENCY BATTERY PACK AND CARRIED OUT INSTALLATION TEST FOUND TEST NORMAL.SDR CALA2025103110784Battery Pack · dischargedCABIN R4 DOOR EXIT LIGHT AND EMERGENCY LIGHT INOPERATIVE, REPLACED THE BATTERY PACK AND CARRIED OUT INSTALLATION TEST, TESTED NORMAL.SDR CALA2025103110781Battery Pack · inoperativeCABIN SEAT 33-37 EMER LIGHT AND R3 DOOR EMER LIGHT INOPERATIVE. REPLACED THE CABIN R3 DOOR AREA M33404 EMERGENCY BATTERY PACK AND CARRIED OUT INSTALLATION TEST,FOUND TEST NORMAL AS PER AMM 33-51-06-960-802 REV 105.SDR CALA2025103010729Oven · dirtyAFT GALLEY OVEN 707 HAS DEBRIS ON IT SO IT BURNS/SMOKES WHEN O N OVEN 707 REAR FAN FOUND TO BE DIRTY SUSPECT CAUSING SMELL. OVEN DEFERRED IAW MEL 2520AV. R & R STEAM OVEN 707 IAW AMM 25-32-02/401, OPS CHKD GOOD. REVERSED NEF OK TO CONTINUE.SDR CALA2025103010725Oven · dirtyAFT GALLEY OVEN 706 HAS DEBRIS ON IT SO IT BURNS/SMOKES WHEN O N OVEN 706 REAR FAN FOUND TO BE DIRTY SUSPECT CAUSING SMELL. NIL TIME TO REPLACE. OVEN DEFERRED IAW MEL 2520AV. R & R AFT GALLEY OVEN 706. NO SMOKE AND NO LEAK NOTED. OPS CKD GOOD. REVERSED NSDR CALA2025102810633Elec Connector · faultedEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - FLOOR PROXIMITY LIGHTS ON CENTER SEAT ROWS 25DEFG TO 32DEFG INOPERATIVE FOUND DAMAGED EMERGENCY LIGHT CONNECTOR PLUG UNDER SEAT G25. REPLACED PLUG AT LOCATION, REF WDM 33-51-64 AND SWPM SDR CALA2025102710586Battery · inoperativeMAIN DECK R3 DOOR M33404 EMERGENCY POWER SUPPLY BATTERY PACK FOUND INOPERATIVE. REPLACED MAIN DECK R3 DOOR M33404 EMERGENCY POWER SUPPLY BATTERY PACK AND PERFORMED BATTERY PACK INSTALLATION TEST, FOUND NORMAL IAW AMM 33-51-06-960-802, REV 105.SDR CALA2025102410491Battery · dischargedEMERGENCY POWER ASSIST SYSTEM (EPAS) 9 VOLT BACK-UP BATTERY INSTALLATION BACKUP 9-VOLT BATTERY INSTALLATION - REMOVED DOOR 1L BUSTLE FOR EPAS BATTERY REPLACMENT REINSTALLED DOOR 1L BUSTLE REF AMM25-66-06 ACP'D INSPECTION ITEM, CLEARED AREA FOR DR 1L SLIDE BUSTSDR CALA2025102210407Lamp · no testEMERGENCY LIGHTS ABOVE 40 AND 43 JKL INOPERATIVE DURING OPS TEST WITH THE CONTROL SWITCHES PROCEDURE, EMERGENCY AREA LIGHTS LAMP REPLACED. IAW 33-51-03-960-801.OPS CHK OK.SDR CALA2025102210416Oven · contaminatedOVEN 707 IN AFT GALLEY WAS SMOKING. OVEN 707 INSERT SOILED IN BURNED FOOD DEBRIS. OVEN REQUIRES CLEAN WHEN TIME ALLOWS. OVEN DEACTIVATED.SDR CALA2025102010307Cover · cracked2L SLIDE COVER CRACKED. C/W ECRA M PROC.SDR CALA2025102010288Battery Pack · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - EMERGENCY PATH LIGHTS INOP IN SEAT 18G, 28G, AND 30D DUPLICATE WRITE UP. WORK PERFORMED ON LOG PAGE #6651473 DUPLICATE LOG PAGE. WORK PERFORMED ON LOG PAGE #6651473SDR CALA2025102010285Module · inoperativePOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - EMERGENCY PATH LIGHTS INOP IN SEAT 18G, 28G, AND 30D REPLACED FLOOR PROXIMITY LIGHT ASSEMBLY ON SEAT 18G, 28G, AND 30D REFER AMM 33-51-05. OPS CHECK GOOD.SDR CALA2025102010281Battery Pack · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - EMERGENCY BATTERY PACK FOR EMERGENCY POWER SUPPLY M33098 OVERDOOR 2R FAILED FUNCTIONAL TEST REPLACED BATTERY PACK AT POWER SUPPLY M33098 OVERDOOR 2R. OP CHECK GOOD REF AMM 33-51-06. OP CHECK GOODSDR CALA2025102010273Engine · bird ingestionBIRD STRIKE FOUND ON ENG #2. ACCOMPLISH BIRDSTRIKE INSPECTION AS PER AMM 72-00-00-210-808-N02 (601) AND CONDITIONAL INSPECTION AS PER AMM 05-51-18-210-801 (201). BIRDSTRIKE FOREIGN OBJECT DAMAGE INSPECTION CARRIED OUT PER AMM 72-00-210-808-NO2, BIRD REMAINSDR CALA2025102010271Oven · smokeOVEN SMOKING, NEEDS CLEANING COACH CLASS CABIN WHITE SMOKE BRIEFLY SMELLED LIKE FOOD. FAN BLACK.ENDED W OVEN OF F OVEN WITH INTENSIVE SMOKE WHEN OPERATES, TX AS PER NEF2520AV. C/B COLLAR APPLIED. REF NEF 2520AV OVEN WITH INTENSIVE SMOKE WHEN OPERATES, TX AS PESDR CALA2025101309949Oven · smokeAFT GALLEY OVEN 709 HAD WHITE SMOKE OUT OF THE TOP VENTS..TURNED OFF SMOKE REPORT FORM COMPLETED AND SENT TO TOMC.TOMC APPROVAL REQUIRED TO DEFER OVEN 709. TOMC APPROVES NEF 2520AV OVEN 709 DEFERRED PER NEF 2520AV, M-PROCEDURE PERFORMED, PLACARD INSTALLED.SDR CALA2025101410077Battery · faultyMAIN BATTERY EICAS STATUS MAIN BATTERY FAILURE. UPON RETURNING TO GATE MAIN BATTERY REPLACED & INSTALLATION TESTED OK. MAIN BATTERY STATUS MX MSG CLEARED. AMM 24-31-01-000-801 & 24-31-01-400-801.SDR CALA2025101309925A/C Pack · overtempSTRONG FUEL SMELL IN FA LOWER REST. ALSO EXTREME Y HOT REF SDS 21-29-00-006 OPERATION NORMAL. SMELL AND HEAT DUE TO EXTENDED USE OF LEFT PACK ON GROUND. WITH LEFT PACK OFF SMELL AND HEAT DISSIPATED AND OPS CHK NORMAL ADD EMP:U346122SDR CALA2025101309929Switch · malfunctionedSOME OF THE EMERGENCY EXIT LIGHTS ARE ON SWITCH IS IN ARM CYCLED F-D SWITCH TO ON - OFF - AND ARM. EEL LIGHTING IN CABIN RESPOND TO EACH SWITCH SELECTION, TESTS OK..SDR CALA2025101309919Filter · dirtyMUSTY ODOR ON INITIAL CLMB DISIPATED THEN ON DSCNT AGAIN REPORT BY FA ADDED FORM 46-6020, SMOKE/ODOR QUESTIONAIRE ON INITAL INVESTIGATION FOUND SLIGHT RESIDUE SMELL IN FLIGHT DECK, CABIN WAS OK. WITH REFERENCE TO AMM 05-51-58-800-801-C3 FOUND WHILE INVESTIGATISDR CALA2025101009907Steering Sys · malfunctionedMAIN GEAR STEERING EICAS ON T/O ROLL DID NOT CLEA REQUEST TOMC A MEL FOR STEERING EICAS 3253A DDP C/W. MLG STEERING INOP LOCKED CENTER MEL OK BY TOMC DDP C/W OK TO CONTINUE MM. 05-01. DUE TO RECENT HISTORY OF MMSG 32-63010 IN AHM AND RECENT EWIS INSPECTIONS SDR CALA2025100909851Battery Pack · inoperativeLLAR EMERGENCY LIGHT POWER SUPPLY M023 BATTERY PACK FOUND POOR CONDITION. REPLACED THE LLAR EMERGENCY LIGHT POWER SUPPLY M023 BATTERY PACK AND PERFORMED NEW BATTERY INSTALLATION TEST IAW AMM 33-51-06-960-803 REV.105. THE TEST RESULT FOUND NORMAL.SDR CALA2025100709714Battery · dischargedDOOR R1 EPAS BATTERY PACK DOESNT CONTINUOUSLY BLINK GREEN IN ARMED POSITION REPLACED DR R1 EPAS BATTERY PACK REF AMM 52-11-20. OPS CHK GOOD.PARTS USED: 26-5211-9-9003, QTY :1 ROTABLE PARTS CHG:TT # 1179479 SN OFF 5831 PN OFF 26-5211-9-9003.BATTERY, ASSY, OFF SDR CALA2025100709725Power Supply · faultedREF W/C 23-3350-1-0001, DURING CHECK FOUND THAT THE PATH EMERGENCY LIGHTS FROM SEAT ROW 40 TO SEAT ROW 53 WILL NOT COME ON. REMOVED AND REPLACED POWER SUPPLY AND BATTERY REF AMM 33-51-06. OPS CHECK NORMAL.SDR CALA2025100809806Oven · smokeOVEN 707 STARTS SMOKING WHEN TURNED ON CONFIRMED FOOD RESIDUE PRESENT BEHIND HEAT SHIELD AND FAN AREA. CREW CONFIRM NO ACRID SMELL BUT SMELL OF BURNT FOOD. NO TIME TO REPLACE OVEN, MEL APPLIED. REMOVED AND REPLACED OVEN 707. OPS CHECK GOOD IAW AMM 25-32-02-40SDR CALA2025100809802Coffeemaker · leakingLAV 4R LEAKED SEWER WATE R OUTSIDE OF LAV BY DOOR 4R INSPECTED TOILET AND SINK ON LAV DR4R NO LEAKS NOTED, SUSPECTED COFFEE SPILLS FROM AFT GALLEY DUE TO EVIDENCE OF COFFEE SILLPS FROM AFT GALLEY. FOUND POTABLE WATER RIGHT AFT GALLEY BY GALLEY SINK. FOUND COFSDR CALA2025100609661Battery Pack · dischargedMAIN DECK R3 DOOR AFT EMERGENCY POWER SUPPLY M33401 BATTERY PACK FOUND POOR CONDITION. REPLACED M/D R3 DOOR AFT EMERGENCY POWE R SUPPLY M33401 BATTERY PACK AND PERFORMED NEW BATTERY PACK INST ALLATION TEST THE TEST RESULT NORMAL AS PER AMM 33-51-06-960-802 RESDR CALA2025100609660Battery Pack · dischargedMAIN DECK L2 DOOR AFT EMERGENCY POWER SUPPLY M33099 BATTERY PACK FOUND POOR CONDITION. REPLACED M/D L2 DOOR AFT EMERGENCY POWE R SUPPLY M33099 BATTERY PACK AND PERFORMED NEW BATTERY PACK INST ALLATION TEST .THE TEST RESULT NORMAL AS PER AMM 33-51-06-960-80 2 SDR CALA2025100609659Battery Pack · dischargedM/D R1 DOOR EMERGENCY POWER SUPPLY M33094 BATTERY PACK FOUND POOR CONDITION. REPLACED M/D R1 DOOR EMERGENCY POWER SUPPLY M33094 BATTERY PACK AND PERFORMED NEW BATTERY PACK INSTAL LATION TEST THE TEST RESULT NORMAL AS PER AMM 33-51-06-960-802 R EV.105.SDR CALA2025100609616Light · inoperativeDUE TO CAB LT MALF CYC CAB/UTIL SW AND EMER EXIT LTS ILLUM FOUND MX MSG 24-12045 "ELCU (UTIL BUS R) IN P200 IS NOT IN COMMANDED POSITION" LATCHED. FOLLOWED FIM 24-51 TASK 807. ACP'D ELMS POWER MANAGEMENT PANEL, P210 INITIATED EU SELF TEST PER AMM TASK 45-10-00SDR CALA2025100709751Skin · ground damageAIRCRAFT AFT FUSALAGE CONTACTED LAV TRUCK AT LAV SVC HATCH. MULTIPLES DENTS AREAS AROUND LAV SERVICE DOOR ON THE STRINGERS THAT REQUIRED OPEN UP FOR FURTHER INSPECTION FOR DAMAGE. REF. SRM 53-00-01-1A-1. SEE ATTACHED PHOTOS FOR LOCATION OF DAMAGE. SKIN AND SDR CALA2025100709749Spring · missingPDA 2 REFRENCE LOG 6494784 FOUND LEFT HAND GEAR SIDE BRACE SPRING MISSING ON ARRIVAL . .LANDING GEAR LEFT STRUT DOWNLINK SPRING MISSING FWD DRAG BRACE AFT SPRING INSTALLED NEW LEFT MLG DRAG BRACE AFT LOCK SPRING AND SPOOLHALF, REF AMM 32-32-07-400-802.SDR CALA2025093009476Battery Pack · dischargedDURING OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND FOUND THAT T HE CABIN L3 DOOR AREA EMERGENCY BATTERY PACK LOW CAPACITY, REPLACED THE C ABIN L3 DOOR AREA M33406 EMERGENCY BATT PACK AND CARRIED OUT INS TALLATION TEST FND TEST NORMAL PER AMM 33-51-06-960-802SDR CALA2025093009475Battery Pack · dischargedDURING OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND FOUND THAT THE CABIN R3 DOOR AREA M33404 EMERGENCY BATTERY PACK LOW CAPACITY. REPLACED THE C ABIN R3 DOOR AREA M33404 EMERGENCY BATT PACK AND CARRIED OUT INS TALLATION TEST FND TEST NORMAL PER AMM 33-51-0SDR CALA2025093009474Battery Pack · dischargedDURING OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND FOUND THAT THE CABIN L1 DOOR AREA M33093 EMERGENCY BATTERY PACK LOW CAPACITY REF TO HAECO NON-ROUTINE NO.9479413, REPLACED THE C ABIN L1 DOOR AREA M33093 EMERGENCY BATT PACK AND CARRIED OUT INS TALLATION TESDR CALA2025093009431Duct · out of alignmentSIGNIFICANT VIBRATION ON RIGHT SIDE OF ACRFT IN CABIN. FAULT TRACED TO LOOSE CLAMP ON DUCT CONNECTED TO R/H PACK RAM AIR OUTLET DOOR (SEE PHOTO). DUCT REFITTED AND CLAMP TIGHTENED PER AMM 21-52-21-400-805. LEAK CHECK CARRIED OUT SUCESSFULLY. LEFT AND RIGHT PACSDR CALA2025093009427Printer · faultedSMOKE SMELL COMING FROM NEW FLT DECK PRINTER OPENED AND COLLARED PRINTER CB D2 IN P210 PANEL REF AMM 31-33-01 UPON ARRIVAL. ACP CONDITIONAL INSP OF FLT DECK REF AMM 05-51-58-800-801-C3 SMELL IS COMING FROM INTERNAL OF NEWLY INSTALLED PRINTER. VISUAL CHECK OF CSDR CALA2025092909345Unknown · odorELECTRICAL SMELL AT 2L SMELL MIGRATED AROUND FORWARD CABIN. PACKS OPERATED USING APU AND BOTH ENGINES AS BLEED SOURCE, REF AMM 71-00-00-790-807-N01. NO VIBRATION OR ODOR NOTED.SDR CALA2025093009424Battery · dischargedEMERGENCY POWER ASSIST SYSTEM (EPAS) 9 VOLT BACK-UP BATTERY INSTALLATION. INSTALLED SLIDE SAFETY PINS (2EA) FOR MAINTENANCE INSTALLED SAFETY PINS AT DOOR L1 SLIDE. REMOVED AND STORED DOOR SLIDE SAFETY PINS (2EA) FROM L1 DOOR SLIDE. C/W IDT, VERIFIED SLIDE SASDR CALA2025100609636Stringer · dentedREF. LOG PAGE # 6361899 STRINGER 49R IS DAMAGED BETWEEN STA. 1958 AND STA. 1979CUT OUT DAMAGED SECTION OF STRINGER REF. SRM 53-70-03-2R-1 REPAIR 1 PARAGRAGH 4.C. REQUEST ON INSPECTOR PERFORM HFEC INSPECTION OF CUT EDGES AND ALL INITAL FASTENER HOLES IN REPAIRSDR CALA2025092909363Actuator · faultedDOOR FLIGHT LOCK 2R EICAS STATUS #2 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SEN SOR DISAGREEMENT.DB PSEU 2 (R2) DB PSEU 2 (L2) SAME 3 FAULTS AS PREVIOUS LEG, REF FIM 52-11 TASK 806. PERFORMED FLIGHT LOCK CONTROL TEST PER AMM 52-11-26-740-801 SDR CALA2025092909359Warning Message · intermittentDOOR FLIGHT LOCK 2R EICAS STATUS #2 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RELAY SENSOR DISAGREEMENT. PSEU 2 (R2) CMC MSG 5212130 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: INITIAL CLIMB DOOR FLIGHT LOCK 2R STATUS MSG ERASED , OK TO CONTINUE
Back to Boeing 777-222