Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013052203554Control System · inoperativeAFT GALLEY FLOOR TEMP CONTROL INOPERATIVE.SDR UALA2013052203550Wire Harness · faultedDUE TO "A" CHANNEL EGT FAULTS ON NR 1 ENG & HIGH INTERNAL CIRCUIT RESISTANCE. AT 9:00 POSITION, FOUND WIDE RESISTANCE CHANGES ON A CHANNEL CIRCUIT. REPLACED WIRE HARNESS W0635 IAW MM 77-21-02. ALL INDICATIONS NORMAL.SDR UALA2013052103512Skin · gougedSMALL GOUGE FOUND ON RT FUSELAGE SKIN AT APPROXIMATELY BS 697, JUST AFT AND ABOVE THE CENTER STATIC PORT. BLENDED GOUGED AREA, AFTER CLEANUP LOSS WAS .010". APPLIED AERODYNAMIC FILLER AND REAPPLIED FINISH. REF SRM 53-30-01, AND SRM 51-30-01, ITEM 9.SDR UALA2013052103519Boot · tornRUMBLING-VIBRATING NOISE ROW 19-24 IN THE FLOOR-UNUSUALLY LOUD. FOUND LEFT PACK FAN BYPASS CHECK VALVE FLEXIBLE ROUND CONNECTOR TORN AND PRODUCING NOISE. REPLACED FLEXIBLE ROUND CONNECTOR BOOT, ALL NOW OKAY.SDR UALA2013052203557Oven · contaminatedOVEN R31 SMOKING FROM LOWER SIDE, PLASTIC LOOKS BURNED. CLEANED DEBRIS. REPLACED R31 OVEN. OPS CHECKED NORMAL IAW AMM.SDR UALA2013052203556Wire · exposedEXPOSED WIRE ON LOWER WALL NEAR L4 DOOR. SECURED. CONDITION OK.SDR UALA2013052103513Control Panel · brokenEXIT LIGHT PANEL BROKEN LOCATION 663. SECURED EXIT LIGHT PANEL.SDR UALA2013052103516Display · inoperativeCONTROL OF THE DISPLAY SELECTOR PANEL HAS BEEN TAKEN OVER BY MANUAL SELECTION OF THE CDU BACKUP DSP FUNCTION. CAPTAIN`S ND DISPLAY INOPERATIVE. REPLACED CAPTAIN INBD DISPLAY UNIT IAW AMM, OPS CHECKED GOOD.SDR UALA2013052203553Audio Panel · faultedCAPTAIN`S AUDIO SELECTOR PANEL CANNOT CHANGE MICROPHONE SELECTION. REPLACED AUDIO SELECTOR PANEL. OPS OK.SDR UALA2013052203525Warning Message · activatedBLEED PRSOV STATUS MESSAGE. MX MSG 36-10380 RECORDED DEFERRED IAW MEL 3611G. CREATED SEPARATE DEFERRAL FOR ENGINE SELECT SYS IAW MEL REQUIREMENTS.SDR UALA2013052103521Overheat Loop · faultedBLEED LOOP 1 BODY STATUS MESSAGE. REPLACED NR 1 LOOP M26144. ACCOMPLISHED FIRE TEST, NO MESSAGE.SDR UALA2013052103514Circuit Card · failedBLEED LOOP 1 BODY FAILURE OF BODY DUCT LEAK DETECTION LOOP OR LT DUCT LEAK OVERHEAT DETECTION SYS. DISCONNECTED M26143 & M26142 ZONE 13 LOOP SEGMENTS, CLEANED AND RECONNECTED, ALSO REPLACED LEFT DLODS CARD. OPS NORMAL, NO STATUS OR CMC MESSAGES.SDR UALA2013052003446Hose · leakingRIGHT MAIN LANDING GEAR, HYDRAULIC LEAK. REPAIRED BRAKE HOSE.SDR UALA2013052103515Selector Panel · inoperativeDISPLAY SELECTOR PANEL INOPERATIVE AND EICAS MESSAGE. REPLACED DISPLAY SELECTOR PANEL IAW MM 31-61-03, SYS CHECKED GOOD.SDR UALA2013052203527Isolation Valve · failedRIGHT BLEED ISOLATION VALVE STATUS MESSAGE. REPLACED ISOLATION VALVE, ALL TEST PASSED & INDICATIONS NORMAL.SDR UALA2013052103500Circuit Card · failedLOW CENTER HYDRAULIC DEMAND PUMP NR 2 PRESSURE WHEN COMMANDED ON, OR CENTER DEMAND PUMP NR 2 OVERHEATED. STATUS MSG-2910007 ACTIVE ER MODE MSG-2911110 INACTV CL MODE MSG-2910490 ACTIVE ER MODE MSG-2910490 ACTIVE ER MODE. REPLACED HYD CL CARD IAW MM 29-11-50SDR UALA2013052103517Latch · brokenNR 2 ENGINE THRUST REVERSER, MOST FWD COWL LATCH ASSY, JUST AFT OF "V" BAND IS BROKEN. REPLACED LATCH ASSY.SDR UALA2013052003445Indicator · faultyF/O HORIZONTAL STAB TRIM INDICATOR HAS TWO INDICATIONS. CYCLED CIRCUIT BREAKER, NO HELP. CAPT OPS NORMAL. REPLACED F/O STAB TRIM INDICATOR IAW MM AND OPS NORMAL.SDR UALA2013052103520Clamp · damagedFOUND RT ENGINE CORE WIRE HARNESS, W0623 AND W0628, DAMAGED NEAR 12 STAGE BLEED DUCT. DAMAGE DUE TO EXCESSIVE HEAT AND CHAFING OF HARNESS DUE TO LOOSE CLAMPS. REMOVED WIRE HARNESS W0623 AND W0628. REPLACED DAMAGED CLAMPS. REPLACED W0623 AND W0628 WIRE HARNSDR UALA2013051703426Windshield · crackedFIRST OFFICER`S WINDSHIELD CRACKED, RTFL CRACKED IN TWO PLACES DURING CLIMB, POSITION 1 RT. REPLACED WINDSHIELD AS PER AMM.SDR UALA2013051703425Slide · deployedESCAPE SLIDE AT R2 DOOR HAS BEEN DEPLOYED ON TO RAMP. CSDR UALA2013051603395Transceiver · inoperativeRIGHT HF WON'T RECEIVE. TRANSCEIVER REPLACED. ACP HF OPS CHECK ON GROUND IAW AMM 23-11-00-501, OPS CHECKED NORMAL. EXERCISED HF COUPLER AND ACP SELCAL CHECK, ALL CHECKED GOOD.SDR UALA2013051503369Radome · faultyRADAR STILL DISPLAYS PHANTOM RETURN AT 7 MIGRTR, RETURN WITH HIGHER TILT. REPLACED RADOME.SDR UALA2013051503364Smoke Detector · false activationEICAS SMOKE UPPER CREW REST DOOR 3. NO SMOKE DETECTED,SDR UALA2013051503370Antenna · faultyWEATHER RADAR SHOWS FALSE RETURNS AS AN ARC AT 7 NM FROM NOSE. BOTH SYS. ALL TILTS. R & R WEATHER RADAR ANTENNA IAW AMM 34-43-03.SDR UALA2013051503371Shutoff Valve · faultyRIGHT PRSOV STATUS MESSAGE. REPLACED RT PRSOV IAW MM. PERFORMED ENGINE AIR SUPPLY OPS TEST. RAN RT ENG IAW JRH 2-2-1. NO EICAS MESSAGE. OPS CHECKED OK.SDR UALA2013051503374Bypass Valve · stuckSTATUS MESSAGE MANIFOLD SENSOR LT, FOUND LT TURBINE BYPASS VALVE STUCK AT .98, MESSAGE 21-23501. REPLACED LT TURBINE BYPASS VALVE IAW MM, OPS CKD GOOD.SDR UALA2013051503372Fmu · faultyAFTER ENG SHUTDOWN EICAS MESSAGE FUEL VALVE RT SHOWED. REPLACED RT ENG FMU IAW AMM.SDR UALA2013051503366Idg · contaminatedREPLACED RT IDG, DUE TO REPEATED IDG FILTER CONTAMINATION WITH IDG AND IDG HX. REMOVED FLUSH PLUMBING LINES IAW AMM. REPLACED IDG & HEAT EXCHANGER, FLUSHED PLUMBING.SDR UALA2013051503365Solenoid · faultyNR 1 ENGINE ELECTRICAL CONNECTOR LOOSE ON STARTER SOLENOID. REPLACED STARTER SOLENOID IAW MM 80-11-07. TEST OK IAW TASK 71-00-00-800-801-N00.SDR UALA2013051503376Ignition Sys · malfunctionedRIGHT ENGINE IGNITER NR 2 STATUS MESSAGE. REPLACED RT ENGINE LOWER EXCITER BOX, IGNITION LEAD, & IGNITER. TEST PASSED NO DEFECTS NOTED.SDR UALA2013051503368Cooling Fins · brokenNR 2 ENGINE STARTER COOLING FINS ON REAR OF STARTER ARE BROKEN. ONE AFT COOLING FIN AT APPROX 3 O'CLOCK POSITION IS CRACKED AT RELIEF HOLE. REPLACED, SERVICED AND OPS CHECKED.SDR UALA2013051503373Isolation Valve · faultedRIGHT BLEED ISOLATION VALVE STATUS MESSAGE ON ARRIVAL. REPLACED RIGHT ISOLATION VALVE AS PER MM. VALVE OPERATES NORMALLY BUT SYNOPTIC DISPLAY FAILED TO SHOW GREEN BAR OR VALVE POSITION IN EITHER CLOSED OR OPEN POSITION. RELOADED ASCIPS SOFTWARE DID NOT FIX. SSDR UALA2013051503375Fuel Cell · leakingFUEL LEAK IN RT DRY BAY LOCATED AT THE AFT UPPER OTBD CORNER. LOCATED FUEL LEAK SOURCE FROM INSIDE TANK. SEALED AREA INSIDE TANK AND IN DRY BAY. APPLIED (A 1-2) SEALANT AT 2300, 12 HR CURE TIME.SDR UALA2013051503367Valve · failedTESTED FSEU, FLAPS FAIL WITH CMC MESSAGE 27-25241. REPLACED PRIMARY RETRACT SOLENOID ON FLAP PRIMARY CONTROL VALVE PER MM, OPS CHECKED OK PER MM. FLAP PRIMARY CONTROL VALVE TEST. EICAS MESSAGE CLEARED.SDR UALA2013051303312Converter · failedELEC BACKUP SYS A FAILURE IN THE BACKUP ELECTRICAL SYS HAS OCCURRED THAT CANNOT BE ATTRIBUTED TO A BACKUP GENERATOR. FOUND BACK UP CONVERTER FAULTY IAW FIM 24-25-TASK 802. 28V DC PCN PRESENT AT PIN 1 OF CONNECTOR 24008, REF WDM 24-25-31. REQUIRED 566-9012 NSDR UALA2013051003286Skin · damagedFOUND L4 DOOR LOWER AFT CORNER WITH A SMALL GOUGE AND BENT. DAMAGE IS 0.75 " WIDE AND 0.20" DEEP. ACCOMPLISHED BLEND REPAIR. PERFORMED HFEC AND PRESSURE CHECK IAW MM 05-51-24, NO LEAKS.SDR UALA2013050903251Diplexer · malfunctionedSAT LOW GAIN. REPLACED LEFT LNA DIPLEXER M23122, OPS CHECKED NORMAL.SDR UALA2013051303291Panel · unsecureOVERHEAD PANEL AT SEAT JK HANGING DOWN. REPLACED FASTENERS AND INSTALLED PANEL TO CORRECT.SDR UALA2013050903250Actuator · leakingNR 2 ENGINE STATOR VANE ACTUATOR LEAKING FUEL. REPLACED SVA PER AMM, OPS AND LEAK CHECK NORMAL.SDR UALA2013050803220Fastener · damagedRIGHT ENGINE FAN COWL SHOWS EVIDENCE OF LIGHTNING DISCHARGE. DAMAGE IS LOCATED AT THE 3:00 O'CLOCK POSITION AND IS LOCATED APPROX 5-8" FWD OF THE AFT EDGE, DAMAGE MEASURES 5-8" BY 5-8". REPLACED SCREW LOCATED AT THE AFT LOWER CORNER OF THE FAN COWL OPERATIONASDR UALA2013051003267Probe · bindingNR 1 ENGINE HPT SECOND STAGE ROTATING AIR SEAL PROBE BOSS WAS DIFFICULT TO REMOVE. REQUIRED PRYING AND TWISTING TO REMOVE. COULD NOT FULLY INSTALL NEW UNIT. BOSS HANGS UP ON THE LAST INCH OF INSTALLATION. BORESCOPED HOLE. NO DEBRIS FOUND. REPLACED TCA PROSDR UALA2013051003266Solenoid Valve · inoperativeLEFT MAIN GEAR DOOR FAILED TO CLOSE. REPLACED LEFT MAIN GEAR DOOR SOLENOID VALVE PER AMM. OPS CHECKED GOOD.SDR UALA2013050803219Spring · out of positionEMERGENCY LIGHT SWITCH WIRE GUARD NOT WORKING PROPERLY. RE-INSTALL SPRING AND SAFEGUARD CAP OPS NORMAL.SDR UALA2013050703191Control Panel · failedON DEP CTR RADIO WONT DEFAULT TO DATA MODE SUSPECT DCMS FAILURE. MEL COMPLIED WITH. RPL- :ACCOMPLISHED TEST PER MM. FAULTED OBSERVER CONTROL PANEL. REPLACED CONTROL PANEL PER MM.SDR UALA2013050903265Radome · erodedRADOME ERODED WITH POSSIBLE DELAMINATION. REPAIRED IAW SRM 53-10-72.SDR UALA2013050703205Probe · damagedENGINE EGT FLUCTUATES. REPLACED NR 4 EGT PROBE PER AMM 77-21-01 AND PERFORMED ENGINE RUN FIVE MINUTES FOUND EGT INDICATIONS NORMAL.SDR UALA2013050703174Seal · unsecureRIGHT WING, INBD OF NR 2 ENGINE AND NEXT TO PYLON, SMALL LEADING EDGE FLAP HAS A SEAL HANGING DOWN ON THE INBD SIDE OF THE FLAP. REMOVE THE 5 INCH OF LOOSE SEAL FROM RIGHT KRUEGER FLAP. REPLACED SEAL.SDR UALA2013050703190Detector Loop · shortedBLEED LEAK, RIGHT WING LOOP 1 ZONE 10 SHORTED, RIGHT WING LOOP 2 ZONE 10 IS SHORTED. FOUND RT PACK HEAT EXCHANGE FLEXIBLE CONNECTOR AND CHECK VALVE DAMAGED. REPLACED BOOT AND CHECK VALVE PER MM, CHECKED OKAY.SDR UALA2013050603128Pump · leakingFUEL LEAKING FROM RT ENGINE. EVIDENCE OF FUEL LEAK FROM NR 5 FUEL PUMP DRAIN. APPROXIMATELY 16 DROPS PER MINUTE, NO LEAKS AFTER ENGINE SHUTDOWN. REPLACED NR 2 ENGINE FUEL PUMP PER MM. LEAK AND ENGINE RUN CHECKED GOOD.
Back to Boeing 777-222