SDR UALA2013060503907Control Valve · failedINTERMITTENT CARGO HEAT VALVE BULK STATUS MESSAGE. CARRIED OUT SYSTEM TEST. TEST FAILS WITH MAINT MESSAGE 21-12032. CHECKED POWER AT DV21444 PER W-D 21-44-21 AND FOUND OK. REPLACED CARGO HEAT SHUTOFF AND TEMPERATURE CONTROL VALVE OPS CHECKED NORMAL IAW MM 2SDR UALA2013060703982Structure · erodedNR 1 ENGINE ACCOUSTICAL LINER 4 O`CLOCK POSITION AFT OF FAN SECTION HAS AREAS OF ERROSION ON PREVIOUS REPAIR APPLIED FILLER TO AREA OF DAMAGE, REPAIR UNDER HEAT LAMP. WILL NEED LAMP REMOVED AT END OF CURE, APPROX 1100 5JUN13. REMOVED HEAT LAMP.SDR UALA2013060503910Hose · leakingNR 2 ENGINE HAS AN OIL LEAK AT 6 O'CLOCK AFT PART OF REVERSER COWL. AFTER VISUAL INSPECTION FOUND HYDRAULIC LEAK FROM LINES UNDER HEAT SHIELD BLANKET FOR EDP. REPLACED PRESSURE HOSE FROM J-BOX TO HYD PUMP. CLEANED AREA LEAK CHECKED GOOD.SDR UALA2013060503903Rub Strip · out of toleranceNR 1 ENGINE AT 6 O'CLOCK POSITION HAS MISSING REPAIR AREA ON FAN BLADE RUBSTRIP. REPAIRED FAN CASE RUBSTRIP REPAIR NR 1 ENG AT 6 O'CLOCK POSITION.SDR UALA2013060503904Valve · failedSTATUS MESSAGE 2112022 FAILURE OF BULK CARGO HEAT SHUTOFF VALVE OR (SOV) OR TEMP CONTROL VALVE (TCV). REPLACED VALVE WITH NEW IAW 21-44-03.SDR UALA2013060503909Indication Sys · malfunctionedAPU OIL PRESSURE INDICATION BLANK.SDR UALA2013060503905Display · failedFIRST OFFICER`S OTBD DISPLAY SCREEN BLACKED OUT, HAS BLACK AND RED STRIPES. TO ALTERNATE DISPLAY CONTROL DISPLAY CAME BACK FOR A MINUTE THEN BLACK AGAIN. RT OTBD DISPLAY BLANK WITH MESSAGE 31-80162. REPLACED RT OTBD DISPLAY UNIT IAW MM. INSTALLATION TEST COSDR UALA2013060503889Oxygen Mask · unwanted deployOXYGEN MASKS DROPPED 9G. MASKS STOWED AND SECURED CLOSE.SDR UALA2013060503890Warning System · activatedACFT RETURNED TO FIELD DUE TO NUMEROUS OVERHEAD PANEL LIGHTS AND EICAS MESSAGES SHORTLY AFTER TAKEOFF.SDR UALA2013060603917Smoke Detector · failedDURING LAV, FLIGHT CREW REST SMOKE DETECTION OP TEST. OEU 1-1-1 M23412, DR1L LAV1F,1C. REPLACED OEU 1-1-1, M23412. OK BUT SMOKE DETECTOR NOW FAILING ON LAV 1F, 1C. PERFORMED ALL CABIN TEST ON CSCP NO FAULTS NOTED REF AMM 26-13-00-50SDR UALA2013060403865Sleeve · damagedNR 1 ENGINE INBD THRUST REVERSER TRANSLATING SLEEVE DAMAGED AT T/E, 4 O'CLOCK POSITION.SDR UALA2013060503908Cap · missingFIRST OFFICER`S WINDSHIELD HAS BARE HIGH VOLTAGE ELECTRICAL CONNECTOR. REPLACED MISSING PROTECTIVE CAP.SDR UALA2013060703989Feeder Cable · damagedNR 1 ENGINE HAS SIGNS OF OVERHEATING ON THE POWER FEEDER CABLES AT THE IDG. REPLACED IDG POWER FEEDER CABLES IAW AMM.SDR UALA2013060503901Sensor · failedCHRONIC BLEED PRSOV RT STATUS MESSAGE. CHRONIC BLEED PRSOV R STATUS MSG WITH VALVE & CONTROLLER REPLACED. VALVE IS FAILING. CLOSED WITH MSG 36-10380. ACP FIM TASK 36-11 TASK 805 STARTING AT ITEM C AND C.6 MUST BE ACP'ED USING METHOD 36-10-00 PG.514. BE CERTAISDR UALA2013060503902Valve · faultyTRIM AIR PRSOV RT. R & R RT TRIM AIR PRSOV IAW AMM 21-62-01. INSTALLATION TEST PASSED. LEAK CHECKED OK.SDR UALA2013053003763Lens · dislodgedR4 DOOR EXIT COVER FELL OFF ON TAKE OFF. BROKEN CLIP. REPLACED LENS AND BASE ASSEMBLIES IAW AMM, OPS CHECKED GOOD.SDR UALA2013053103807Windshield · delaminatedCAPTAIN'S WINDSHIELD DELAMINATED. REMOVED CAPTAIN'S WINDSHIELD IAW AMM. INSTALLED WINDSHIELD IAW AMM, CHECKED OK.SDR UALA2013053103806Smoke Detector · inoperativeAFT CARGO SMOKE DETECTOR EICAS MESSAGE. REPLACED AFT CARGO SMOKE DETECTOR, OPS CHECKED GOOD.SDR UALA2013053003764Wire Harness · failedNR 2 ENGINE FIRE LOOP STATUS MESSAGE. REPLACED WIRE HARNESS W656 IAW WD 26-11-11.TEST PASS IAW AMM 26-11-00.SDR UALA2013053003761Cap · missingPROTECTIVE CAP LOWER RT CORNER, RT WINDSHIELD MAY BE MISSING. INSTALLED CAP.SDR UALA2013053003762Cover · missingEMERGENCY EXIT PLASTIC COVER MISSING. COMPLIED WITH ECRA 3351- 01060. OPS CHECKED SATISFACTORY.SDR UALA2013052903730Compressor · noisyWATER COMPRESSOR MAKING NOISE. REPLACED AIR COMPRESSOR, OPS CHECKED GOOD.SDR UALA2013052903747Relay · malfunctionedDURING SHUTDOWN OF NR 2 ENGINE, FUEL FLOW DROPPED TO ZERO. ENGINE SHUTDOWN NORMALLY THEN FUEL FLOW SHOWED INDICATIONS ERRATICALLY BETWEEN 200-700 LBS. REPLACED RT ENGINE RELAY UNIT IAW AMM, OPS CHECKED GOOD ON ENGINE RUN.SDR UALA2013052903736Shutoff Valve · failedFAILURE OF AFT CARGO HEAT SHUTOFF VALVE OR TEMP CONTROL VALVE. STATUS MESSAGE 2112031, INACTIVE ER MODE MESSAGE 2112031, LATCHED ER MODE. R & R TEMP CONTROL SHUTOFF VALVE IAW MM, OPS CHECKED NORMAL.SDR UALA2013052903745Check Valve · out of toleranceNR 1 ENGINE LEFT IP CHECK VALVE IS OUT OF LIMITS IAW ACK JC 2-4130. REPLACED LT IP CHECK VALVE.SDR UALA2013052903744Wire · severedFOUND F/O MICROPHONE CONNECTOR SEVERED FROM WIRING. REPLACED F/O HEADSET.SDR UALA2013052903746Sleeve · crackedNR 2 ENG IDG, POWER FEEDER WIRE COLORED IDENTIFICATION SLEEVES ARE CRACKED AND DISCOLORED. REPLACED YELLOW IDENTIFICATION SLEEVE.SDR UALA2013052903731Window · crackedWINDOW INNER PANE HAS TWO CRACKS AT SEAT 35A. REPLACED INNER PANE ON WINDOW REVEAL ASSY AND OK.SDR UALA2013052803700Control Panel · failedMODE CONTROL PANEL LANE 1 OF THE 2 LANES IN AUTOPILOT FLIGHT DIRECTOR SYS (AFDS) MODE CONTROL PANEL (MCP) OR ITS INTERFACE TO THE AFDC HAS FAILED. REPLACED MCP IAW MM, OPS TESTED OK.SDR UALA2013052903740Line · leakingFOUND HYDRAULIC LEAK COMING FROM RT MLG (UPPER AREA). FOUND LEAK COMING FROM FLEX LINE ON RT MLG ANTI-SKID BRAKE LINE. REPLACED FLEX LINE. SERVICED HYD SYS TO FULL. LEAK CHECKED, FOUND NO LEAKS.SDR UALA2013052903739Drive Unit · failedWX RADAR LT & RT FAILED TEST SHOWS ANT FAILURE. REPLACED WX RADAR DRIVE UNIT.SDR UALA2013052903735Vane · burnedNR 1 ENGINE HPT FIRST STAGE VANES HAS ONE VANE BURNED THRU ON OD PLATFORM THAT EXTENDS INTO THE PLATFORM FILLET RADIUS LOCATED BEHIND LOWER IGNITER PLUG. ACCOMPLISHED NR 1 ENGINE BOROSCOPE INSPECTION OF HPT NGV. IAW DISPOSITION ECRA 7200-03291 MEASURES LESS SDR UALA2013052803673Controller · failedRT ENGINE BLEED FAN AIR MODULATING VALVE FAILED OPEN OR CLOSED, OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILED. REPLACED THE RT ASCPC IAW MM. REACTIVATED FAMV TEST NORMAL. NO FAULTS.SDR UALA2013052903742Controller · failedNR 2 ENGINE ANTI-ICE VALVE FAILED TO OPEN ON ENGINE RUN. ACCOMPLISHED CMC TEST ENGINE RUNNING STILL FAILED TEST. REPLACED NR 2 ENGINE ANTI-ICE VALVE CONTROLLER IAW MM. OPS CHECKED GOOD ON IDLE RUN IAW TASK 30-21-00-730-806-003.SDR UALA2013052803675Overheat Loop · shortedBLEED LOOP 2 BODY STATUS MESSAGE DISPLAYED ON EICAS. M LOOP 2, ZONE 18 IS SHORTED. TROUBLESHOT PER FIM 26-18 TASK 804. R & R NR 2 BODY LOOP DETECTOR IAW AMM 26-18-04. OPS CHECKED NORMAL, STATUS MESSAGE CLEARED.SDR UALA2013052903743Rub Strip · missingFWD LOWER RUBSTRIP MISSING 1H. REPLACED RUBSTRIP.SDR UALA2013052803710Charger · faultyAPU WILL NOT START. MESSAGE FOR APU BATTERY CHARGER. APU BATTERY CHARGER REPLACED IAW AMM. APU ELECT START NORMAL.SDR UALA2013052903738Lens · unsecureEXIT SIGN LENS ABOVE 2L DETATCHED. SECURED LENS ASSY.SDR UALA2013052903734Actuator · false indication"APU DOOR" STATUS MESSAGE DISPLAYED. CONFIRMED APU DOOR FULLY OPEN WITHOUT ANY STATUS MESSAGE OTHER THAN APU DOOR. MAT SHOWS POSSIBLE CAUSES AS APU INLET DOOR ACTUATOR & APU INLET DOOR CONTROL RELAY. REPLACED APU DOOR ACTUATOR.SDR UALA2013052903737Coupling · disintegratedLEFT A/C PACK COUPLING CONNECTING LEFT DIFFUSER TO LEFT HEAT EXCHANGER DISINTEGRATED. REPLACED CONNECTING COUPLING, IAW AMM 21-52-10.SDR UALA2013052903741Pressure Switch · failedAPUC DETECTED LOSS OF ABILITY TO PNEUMATICALLY LOAD APU. MESSAGE IS TRIGGERED BY IGV OR SURGE CONTROL SYS FAULTS. REPLACED DIFFERENTIAL PRESSURE SWITCH. OP CHECKED GOOD. STATUS MESSAGE CLEARED.SDR UALA2013052903733Fseu · faultyFLAP SLAT CONTROL 1 AND PFCS INTERFACE MESSAGES DISPLAYED ON LOWER EICAS DISPLAY. REPLACED FSEU NR 1, MESSAGE CLEARED AND MAT GROUND TEST PASSED OK.SDR UALA2013052903732Controller · failedRT ENGINE BLEED PRESSURE REGULATING SHUTOFF VALVE (PRSOV) FAILED OPEN OR CLOSED OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. REPLACED PRSOV CONTROLLER PER MM AND OPS CHECK OKAY.SDR UALA2013052803699Filter Element · faultyENGINE OIL FILTER SENSOR RT STATUS MESSAGE DISPLAYED DURING FLIGHT. ACCOMPLISHED TEST ON MAT, SHOWS OK, REPLACED NR 2 MAIN OIL SCREEN IAW MM. CHECKED SWITCH CONNECTOR, AND SECURED. MESSAGE WAS ERASEABLE ON MAINT PG, CLEARED MESSAGE IAW 79-98 TASKS 801. FSDR UALA2013052803711Structure · crackedNR 2 ENGINE, NR 4 GAP COVER STRIP IS CRACKED. REMOVED DAMAGE AND BLENDED AREA IAW SRM 54-50-70. HFEC INSP REQUIRED. REWORKED DIMENSIONS ARE 3.75" FROM INBD EDGE 7.4375 WIDE AND .056" GAP. TOTAL AREA OF EXPOSURE IS .4165 SQ" ACCOMPLISHED HFEC INSPECTION IAW SDR UALA2013052803677Idg · malfunctionedRT ENGINE GENERATOR DRIVE LIGHT DID NOT ILLUMINATE AFTER ENGINE SHUTDOWN. REPLACED NR 2 IDG IAW MM. DRIVE LIGHT OUT. OPS NORMAL.SDR UALA2013052203559Warning Light · false activationAFTER LANDING, SMOKE WARNING IN LOWER LOBE CREW REST AREA CABIN, CREW DISCHARGED FIRE BOTTLE. INSPECTED AREA ON ARRIVAL, NO SMOKE DAMAGE FIRE EVIDENCE OR OTHER ODORS SUCH AS ELECTRICAL BURNING.SDR UALA2013052203528Shutoff Valve · failedLEFT TAIL HYD SHUTOFF VALVE IS FAILED IN THE CLOSED POSITION. REPLACED VALVE.SDR UALA2013052303563Relay · faultySTATUS MESSAGE, DC STANDBY ELECTRICAL POWER 24 13037. FOUND K24013 RELAY BAD, REPLACED OPS CHECKED GOOD. MESSAGE CLEARED.SDR UALA2013052203549Sensor · faultyTEMP HARD TO CONTROL ZONES D-E-F. STAYS TOO COLD. REPLACED RT PACK COMPRESSOR DISCHARGE TEMP SENSOR M21520 IAW MM, OPS CHECKED GOOD.
Back to Boeing 777-222