SDR CALA2013111800851Battery · failedB777-33-3-0022 CABIN R3 DOOR EMERGENCY LIGHT BATTERY M33401 CAPACITY CHECK FAILED. R3 DOOR EMERGENCY LIGHT BATTERY M33401 REPLACED & CAPACITY CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013111800850Battery Pack · failedB777-33-3-0022 CABIN L3 DOOR EMERGENCY LIGHT BATTERY M33405 CAPACITY CHECK FAILED. CABIN L3 DOOR EMERGENCY LIGHT BATTERY M33405 REPLACED & CAPACITY NORMAL IAW AMM 33-51-06.SDR CALA2013110500804Sensor · failedRT PACK FAILED APPROXIMATELY 10 MIN AFTER TAKEOFF. APPLIED APPROPRIATE CHECKLIST PROCEDURE. PACK REMAINED FAILED. TROUBLESHOT IAW FIM 21-51-00-810-830 & HAD FAULT CODE 21-24302. R-FCV OPERATIONS CHECKED GOOD AS DID WIRING IAW FIM 21-51-00. R & R AIR SUPPLYSDR CALA2013101600749Unknown · malfunctionedALL LAVATORIES WILL NOT FLUSH, NO MOTOR OR H2O INOPERATIVE. WHEN A/C ARRIVED ALL LAVATORIES FLUSHED & INDICATION WAS GOOD. IAW FORMED BITE CHECK ON FWD MID & AFT WASTE TANK LOGIC CONT MODULES, ALL CHECKED GOOD. SERVICED LAVATORIES & POTABLE WATER FOR CONFISDR CALA2013091100651Lug · brokenREF LP 7484745 - APU FIRE INDICATION AFTER ENG SHUTDOWN. T/S AS PER WD 26-15-11, CHECKED WIRING & LOOP RESISTANCE - ALL RESISTANCE WITHIN LIMITS. R & AMP;R''D M26009 DUE BROKEN LUG, ALSO R & AMP;R''D A9 FIRE DETECTION CARD AS PRECAUTIONARY. IAW LP 7484745 FOSDR CALA2013090900637Apu · fireAPU FIRE AT GATE 138 JUST AFTER SHUTTING DOWN ENGINES FIRE TWO BOTTLES. R&R APU FIRE BOTTLE IAW MM 26-22-01-00-801. OPERATIONS CHECKED NORMAL.SDR CALA2013083000594Battery · failedSMOKE ODOR IN FLIGHT DECK CABIN. SMOKE ODOR IN FLIGHT DECK CABIN CONDITIONAL INSPECTION CHECKED OUT IAW AMM TASK 05-51-58-800-801C3 - SATISFACTORYSDR CALA2013082300585Structure · damagedPER L/P 4513792 HFEC INSPECTON OF LOWER R1 DOOR AFT CORNER AREA 1.5 LONG INDICATION OF DEFECTS NOTED APPROXIMATELY 12 INCHES OF LOWER AFT CORNER. ROUND DAMAGE TO BE WITHIN ALLOWABLE DAMAGE IAW SRM 52-10-01 ALLOWABLE DAMAGE 1. R1 DOOR AFT LOWER CORNER REPAIRESDR CALA2013082100584Battery Pack · dischargedEMERGENCY LIGHT BATTERY M9073 DISCHARGED. REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013082100583Battery Pack · dischargedCABIN G9 GALLEY EMERGENCY LIGHT FOUND INOPERATIVE, BATTERY PACK REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013082100582Lamp · inoperativeDOOR 3R EXTERIOR EMERGENCY LIGHT FOUND INOPERATIVE. LAMPS REPLACED AND TESTED NORMAL IAW AMM 33-51-04.SDR CALA2013081400566Socket · wornONE OF THE SOCKETS FOR FLUORESCENT MIRROR LIGHT BURNED OUT IN LAV "L", CAUSING ELECTRICAL SMOKE. SOCKET NEEDS TO BE REPLACED. DOME LIGHT WORKS OK. LAV USEABLE. TOMC UPDATE: CHANGED ITEM 33-21-1 TO NEW HARMONIZED ITEM ITEM DEFERRED IAW MEL 33-21-1, CN 651188SDR CALA2013080700546Socket · burnedF/A REPORTED ODOR OF ELECTRICAL SMOKE FROM LAVATORY "L", AFTER INVESTIGATION, IT WAS REPORTED THAT BALLAST FOR FLUORESCENT LIGHT WAS HOT TO TOUCH. AFTER CONSULTING WITH MX, DISCONNECTED BULBS. EVIDENCE OF SCORCHING AT BASE OF ONE BULB. BALLAST COOLED IMMEDSDR CALA2013072600515Fan · failedSTRONG ODOR OF ELECTRIAL BURNING THROUGHOUT ACFT, TURNED IFE & PAX SEATS, CABIN UTILITY & OVENS OFF. ODOR CONTINUED ON AND OFF MAT SHOWS LOWER RECIRCULATION FAN LT AT FAULT. R & R FAN, UPON REMOVAL, FAN HAD STRONG BURNED ODOR, REPLACED LT RECIRCULATION FILSDR CALA2013072600516Screw · misinstalledLEFT WING L/E AT WS 406 APPROX L/E SLAT TORQUE TUBE TO ANGLE TRANSFER DRIVE CONNECTION COUPLING SLEEVE, FOUND ONE LOCK SCREW NOT PROPERLY INSTALLED LT WING L/E SLAT TORQUE TUBE COUPLING SLEEVE ATTACH SCREW REPLACED AND LOCKWIRE RESECURED IAW AMM 27-81-38.SDR CALA2013072200509Printer · smokeSMOKE IN COCKPIT ORIGINATING UNDERNEATH CAPTAINS SEAT. EMERGENCY DECLARED, DIVERTED. SOURCE UNKNOWN, PERFORMED INITIAL CONDITIONAL INSPECTION FOR SMOKE/ODOR IN CABIN IAW AMM 05-51-58-800-801C3. FOUND PRINTER AT FAULT CAUSING SMOKE/ODOR IN CABIN. R & R PRINTSDR CALA2013071700495Indicator · failedINFLIGHT AT FL340, RECEIVED A STATUS MESSAGE "FUEL QUANTITY." CENTER FUEL QUANTITY INDICATOR WAS BLANKED OUT. LT FUEL QUANTITY INDICATOR BLANKED OUT. MX FUEL QUANTITY PAGE SHOWED LEFT MAIN NR 17 WITH AN X, CENTER ALL X`S, AND LATER RT MAIN SHOWED X ON NR 14SDR CALA2013062800464Battery · failedR2 DOOR EMERGENCY LIGHT BATTERY M33097, M33098 CAPCAITY CHECK FOUND FAILED. CABIN RT DOOR 2 EMERGENCY LIGHT 2 EA BATTERY PACKS AND FUSE REPLACED, OPS TEST CARRIED OUT AND RESULT NORMAL IAW AMM 33-51-0 6.SDR CALA2013062800463Battery Pack · failedL3 DOOR EMERGENCY LIGHT BATTERY M33407 CAPACITY CHECK FOUND. CABIN L4 DOOR EMERGENCY LT BATTERY PACK M33407 REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2013062800462Battery Pack · failedL3 DOOR EMERGENCY LIGHT BATTERY M33405, M33406 CAPCAITY CHECK FAILED. CABIN DOOR L3 EMERGENCY LIGHT 2EA BATTERY PACKS AND FUSE REPLACED, OPS TEST CARRIED OUT AND RESULT NORMAL IAW AMM 33-51-06.SDR CALA2013062800461Charger · faultedR3 DOOR AND COCKPIT P11 CIRCUIT BREAKER H16 TRIPPED. TROUBLESHOOTING FOUND R3 DOOR EMERGENCY BATTERY CHARGER INTERNAL FAULT. EMERGENCY LIGHT BATTERY CHARGER REPLACED AND OPS TEST NORMAL IAW AMM 33-51-06 AND AMM 52-11-00.SDR CALA2013062800460Battery · failedR3 DOOR EMERGENCY LIGHT BATTERY M33401, M33404 CAPACITY CHECK FAILED. CABIN DOOR R3 EMER LT 2EA BATTERY PACKS AND FUSE REPLACED, OPERATIONAL TEST CARRIED OUT AND RESULT NORMAL IAW AMM 33-51-06.SDR CALA2013062800459Battery · failedB777-33-3-0023, CABIN R4 DOOR EMERGENCY LT BATTERY M33409, CAPACITY CHECK FAILED. CABIN R4 DOOR EMERGENCY LT BATTERY PACK M33409, REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2013062500449Skin · dentedON LEFT SIDE OF ACFT, NEAR L2, ACFT HAS A DEEP DENT. FUSELAGE SKIN DENTED THREE AREAS BS 676 BETWEEN S26-27L. REPAIRED IAW ECRA 5310-03726, REV B, ITEM 5 AND SRM 53-00-01. REPAIR 4, FIG 202.SDR CALA2013061900431Battery Pack · inoperativeR3 DOOR EPAS GREEN TEST LIGHT INOPERATIVE. REPLACED EPAS BATTERY PACK IAW MM 52-11-20.SDR CALA2013061200401Fuse · inoperativeCABIN ZONE D, RT CEILING EMERGENCY LIGHT INOPERATIVE. BOTH R3 & R4 DOOR EMERGENCY BATTERY FUSES REPLACED AND OPERATION CHECKED NORMAL IAW AMM 33-51-00.SDR CALA2013052300346Battery · no testL2 DOOR EMERGENCY LIGHT BATTERY FAILED CAPACITY CHECK. BATTERY PACK REPLACED AND OPS CHECKED NORMAL AS IAW AMM 33-51-06.SDR CALA2013052300345Battery · no testR3 DOOR EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK FAILED. BATTERY PACK REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013052300344Battery · no testL3 DOOR EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. BATTERY PACK REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013052300343Battery Pack · failedCABIN L1 DOOR EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013052300342Battery Pack · failedR4 DOOR EMERGENCY LIGHT BATTERY CHECK FAILED. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013052300341Battery Pack · failedR2 DOOR EMERGENCY LIGHT BATTERY FOUND TO HAVE FAILED. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013050600277Battery · no testCABIN R2 DOOR EMERGENCY LIGHT BATTERY M33097, M33098 CAPACITY CHECK FAILED. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013050300262Controller · inoperativeAFTER T/O "ENG BLEED LT OFF EICAS" LT BLEED VALVE FUEL DUMP AND RETURNED TO EWR. REFER TO L/P 7351111 PARTS CHANGE AND OPS TEST.SDR CALA2013041800233Fan · failedF/A REPORTED THE ODOR OF BURNING INSULATION BETWEEN DOOR 3 L-R & 2 L-R. RAN THE SMOKE FIRE, OR FUMES CHECK LIST. ODOR CLEARED ON & TOTALLY AFTER 2.5 MINUTES. CONTACTED MX CONTROL & DISPATCH VIA SATCOM. INSPECTED CEILING LT, LAV LT AND BALLAST, DOOR HEATER, SDR CALA2013041600222Battery · failedCABIN L3 DOOR EMER LIGHT BATTERY M33400 FAILED CAPACITY CHECK. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013041700228Battery · failedCABIN L4 DOOR EMERGENCY LIGHT BATTERY M33407 FAILED CAPACITY CHECK. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013041700227Battery · failedCABIN L1 DOOR EMERGENCY LIGHT BATTERY M33093 FAILED CAPACITY CHECK. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013041700226Battery · failedCABIN R2 DOOR EMERGENCY LIGHT BATTERY M33098 FAILED CAPACITY CHECK. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013041700225Battery · failedCABIN R4 DOOR EMERGENCY LIGHT BATTERY M33409, CAPACITY CHECK FAILED. BATTERY REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013041700224Battery · failedCABIN L2 DOOR EMERGENCY LIGHT BATTERY M33099, CAPACITY CHECK FAILED. BATTERY REPLACED. OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013041200216Generator · malfunctionedAFTER ENGINE START ELECRICAL BACKUP GENERATOR RT EICAS MESSAGE AND CHECK LIST. R & R BACK-UP GENERATOR IAW MM 24-25-01-400-804- 0-01. OP AND LEAK CHECK GOOD.SDR CALA2013041200215A/C Pack · inoperativeLEFT PACK INOPERATIVE, RESET LEFT PACK. OPS CHECKED GOOD.SDR CALA2013031400159Switch · failedL2 DOOR EPAS BATTERY OPS TEST FAILED. CARD 25-5210-1- 9801, STEP 1E6 (AMBER TEST LIGHT NOT ON) FOUND HIGH RESISTANCE IN MODE SELECT SWITCH. R & R; MODE SELECT SWITCH REF AMM 52-11-28-00-801. SYS TEST PASS IAW W/C 25-5210-1-9801 AND AMM 52-11-28.SDR CALA2013021400104Battery Pack · no testL1 DOOR EMERGENCY LIGHT BATTERIES M33093, M33424, FOUND CAPACITY CHECK FAILED. BATTERIES REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400103Battery Pack · no testR1 DOOR EMERGENCY LIGHT BATTERY, M33094, CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400102Battery Pack · no testR4 DOOR EMERGENCY LIGHT BATTERY, M33409, CAPACITY CHECK FAILED. BATTERY, REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400101Battery Pack · no testL3 DOOR EMERGENCY LIGHT BATTERY, M33405 CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400100Battery Pack · no testL2 DOOR EMERGENCY LIGHT BATTERY, M33096, CAPACITY CHECK FAILED. BATTERY, REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400098Battery Pack · failedR3 DOOR EMERGENCY LIGHT BATTERY M33401 CAPACITY CHECK FAILED. BATTERY REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.
Back to Boeing 777-224