Boeing 777-224
Service difficulty reports · 1,594
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777224' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777224' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013021400097Battery Pack · no testR2 DOOR EMERGENCY LIGHT BATTERIES M33097, M33098 FOUND CAPACITY CHECK FAILED. BATTERIES REPLACED AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013021400096Battery Pack · no testL4 DOOR EMERGENCY LIGHT BATTERY, M33407 FOUND CAPACITY CHECK FAILED. BATTERY PACK REPLACED IAW AMM 33-51-06 AND OPS CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013012500059Battery · dischargedAFT ZONE RT CEILING EMER LT FOUND NOT ILLUMINATE. R4 DOOR M33409 EMER LT POWER SUPPLY REPLACED AND OPS CHECK NORMAL IAW AMM 33-51-06.SDR CALA2013012500058Battery · failedFWD ZONE CABIN SEAT EMERGENCY LT BOTH SIDE FOUND INOPERATIVE. M33094, M33093 EMERGENCY LT POWER SUPPLY REPLACED AND LAMP TEST NORMAL IAW AMM 33-51-06.SDR CALA2013012500057Battery · failedAFT ZONE CABIN SEAT FROM 31DEF TO 45DEF FOUND SEAT EMERGENCY LIGHT NOT ILLUMINATE. R3 DOOR M33401 EMERGENCY LT POWER SUPPLY REPLACED AND OPS CHECK NORMAL IAW AMM 33-51-06.SDR CALA2013012500056Bulb · failedR2 DOOR EXTERIOR EMERGENCY LIGHT FOUND INOPERATIVE. LAMP REPLACED AND OPS CHECKED NORMAL IAW AMM 33-54-04.SDR CALA2013011100034Wire · brokenEMERGENCY EXIT SIGN AT R4 DOOR 4 HAS BROKEN WIRE AND IS INOPERATIVE. SPLICED WIRE IAW SWP 20-10-13 OPS GOOD.SDR CALA2013010400006Power Supply · failedR3 DOOR EMERGENCY POWERPACK, M33404, FOUND FAILED. EMERGENCY POWERPACK M33404 REPLACED AND FUNCTION CHECK NORMAL IAW AMM 33-51-06.SDR CALA2013010400005Power Supply · failedR1 DOOR EMERGENCY POWER PACK FOUND FAILED. R1 DOOR EMERGENCY POWER PACK REPLACED AND FUNCTION CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2013010400004Power Supply · failedR4 DOOR EMERGENCY POWER PACK FOUND FAILED. EMERGENCY POWER PACK REPLACED AND FUNCTION CHECK NORMAL IAW AMM 33-51-06.SDR CALA2013010400003Charger · inoperativeAFT ZONE, RT CEILING EMERGENCY LIGHT FOUND INOPERATIVE. EMERGENCY LIGHT BATTERY, M33401 AND BATTERY CHARGER REPLACED AND FUNCTION CHECK NORMAL IAW AMM 33-51-06.SDR CALA2012123100901Seat Belt · inoperativeSEAT 9K STRIPPED OFF SEAT BELT BUCKLE. R & R SEAT BELT AT SEAT 9K. OPS CHECKED OK.SDR CALA2012121900863Skin · dentedDENT ON L/E OF NR 4 SLAT, APPROX 48" FROM INBD END. PERFORMED INTERIM REPAIR IAW PART 1 OF EC/RA 5743-01131.SDR CALA2012110800774Power Supply · defectiveR2 DOOR EMERGENCY LIGHT POWER SUPPLIES M33097, & M33098 FAILED CAPACITY CHECK. POWER SUPPLIES M33097, & M33098 REPLACED AND CAPACITY CHECKED NORMAL IAW AMM 31-51-06.SDR CALA2012110800773Battery Pack · no testR3 DOOR EMERGENCY LIGHT BATTERIES M33406, M33404 FAILED CAPACITY CHECK. BATTERIES M33406, M33404 REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2012110800772Power Supply · defectiveL2 DOOR EMERGENCY LIGHT POWER SUPPLIES M33096, M33099 FAILED CAPACITY CHECK. POWER SUPPLIES M33096, M33099 REPLACED AND CAPACITY CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2012110800771Battery Pack · no testL3 DOOR EMERGENCY LIGHT BATTERY M33400 FAILED CAPACITY CHECK. BATTERY M33400 REPLACED AND CAPACITY CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2012110800770Battery Pack · no testL4 DOOR EMERGENCY LIGHT POWER SUPPLIES M33405, M33407M, FAILED CAPACITY CHECK. POWER SUPPLIES REPLACED AND CAPACITY CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2012110200743Skin · dentedDENT AT BS 697, STRINGER 27L DAMAGE IS JUST FWD OF THE L2 DOOR. SKIN REPAIRED IAW SRM 53-00-01, REPAIR 7.SDR CALA2012110200734Skin · dentedON ARRIVAL IT WAS NOTED THERE WAS A GOUGE & DENT 3 FEET FWD OF NR 4 DOOR RT AREA INSPECTED & FOUND TO BE WITHIN MM LIMITS, REF SRM 53-00-01.SDR CALA2012110200727Skin · dentedFOUND SMALL SCRATCH AND DENT ON FWD LWR EDGE OF BULK CARGO DOOR SKIN DAMAGED. FOUND TO BE WITHIN LIMITS IAW SRM 52-30-01.SDR CALA2012110100713Skin · dentedSKIN FOUND DENTED AT BS 674, WL 207. FUSELAGE SKIN REPAIRED IAW SRM 53-00-01, FIG 202, REPAIR 7.SDR CALA2012110100703Skin · damagedSKIN DAMAGE AT BS 487 STRINGER 47L. SKIN REPAIRED IAW SRM 53-00-01 REPAIR 7 FIG 202.SDR CALA2012110100702Skin · dentedSKIN FOUND DENTED AT BS 467 STR 41L, DEPTH 0.064" WIDTH 1", LENGTH 2.674". EXCEEDS SRM 53-00-01 FIG 102 ALLOWABLE DAMAGE LIMITS. SKIN REPAIRED & REPAIR DOUBLER CRITICAL ROW FASTENERS INSTALLEDSDR CALA2012091700607Striker · inoperativeCOCKPIT DOOR FAILS TO UNLOCK. R & R SOLENOID ACTUATED DOOR STRIKER IAW AMM 52-52-01. OPS CHECK GOOD.SDR CALA2012091700604Wire · looseELECTRIC ODOR ON DECENT, WENT AWAY, ELECTRIC ODOR AGAIN ON TAXI-IN THEN GOES AWAY, AFTER BLOCK IN F/O AND IROS DETECTED ELECTRICAL ODOR AGAIN OVER BY F/O SIDE OF ACFT. FOUND BAD CRIMP ON FOS MAP LIGHT. ALL INSPECTIONS IAW MM 05-51-58 PARA B, MX R & MAP LIGHTSDR CALA2012082100526Chiller · inoperativeF/A CALLED SAID HEAVY HOT ELECTRIC SMELL IN REAR OF CABIN PERFORMED SMOKE/ODOR INSP IAW AMM 05-51-58-800-801C3. FOUND MID GALLEY SFT CHILLER OVERHEATING & AMP; NOT SHUTTING OFF, PLACED CHILLER ON PLACARD. CHILLER DEACTIVATED. REMOVED & AMP; REPLACED CHILLER NRSDR CALA2012082100525Hmu · malfunctionedRIGHT ENGINE FAILED AND EGT ROSE TO START LIMIT. ENGINE WAS SHUTDOWN. CHECKED MAT FOR CURRENT LEG FAULTS, FOUND 73-31802 AND 73-21002 . TROUBLESHOT IAW FIM 73-22 TASK 815. WITH EEC POWER IN TEST NO FAULTS FOUND . ALSO TROUBLESHOT IAW FIM 73-22 TASK 828. FAULTSDR CALA2012081300501Skin · damagedLIGHTINING STRIKE AT BS 1245, STRINGER 6 LT. INSTALLED REPAIR DOUBLER AS REF TO SRM 53-00-01. REPAIR 6, FIG 203 AND ECRA 5340-01470.SDR CALA2012081300500Skin · damagedLIGHTINING STRIKE AT BS 1245 STR 6 LT. INSTALLED REPAIR DOUBLER AS REF TO SRM 53-00-01. REPAIR 6, FIG 203 AND ECRA 5340-01470.SDR CALA2012080600497Chiller · inoperativeSTRONG ELECTRICAL ODOR AT AFT GALLEY. GALLEY POWER SWITCH TURNED OFF AND CIRCUIT BREAKERS PULLED. ODOR DISSAPATED, FOUND AFT GALLEY CHILLER B CIRCUIT BREAKER TRIPPED. R & R CHILLER IAW MM 25-3 3-03. OPS CHECKED GOOD.SDR CALA2012070500430Vent · damagedNR 2 ENGINE EXHAUST FWD CENTER BODY HAS A SECTION MISSING. R & R ENGINE NR 2 CENTER VENT TUBE IAW MM 78-11-03 AND R & RT FWD CENTER BODY IAW MM 78-11-02. OPS CHECKED GOOD.SDR CALA2012061900407Battery Pack · weakSUPPORT TASK L1 CEILING HEADER EMERGENCY LIGHT BATTERY PACK WEAK. L1 CEILING HEADER EMERGENCY LIGHT BATTERY PACK REPLACED AND TEST NORMAL IAW AMM 33-51-06.SDR CALA2012050700331Door · unknownF/A OVERHEAD CREW REST DOOR DIFICULT TO OPEN FROM INSIDE, REQUIRED ASSISTANCE FROM OUTSIDE TO BE OPENED. CHECKED ON GROUND DOOR, OPENED & CLOSED OK.SDR CALA2012050700329Light · intermittentRAN IFE /PASS SUPPLY CHECK LIST TO HELP RESTORE IFE, NR 3 FLT ATT REPORTED INTERMITTENT FLUORESCENT LIGHTS FLICKER IN CABIN AND A ODOR OF ELECTRICAL SHORT NEAR DOOR 3R TURNED OFF IFE INSPECTED NOTED AREA AROUND 3R DOOR ALSO OPERATED (CSAP) COMPARTMENT CHECK ALSDR CALA2012042600298Charger · inoperativeCTR ROW FLOOR EMERGENCY PATH LIGHTING INOP FROM ROW 1 TO ROW 11 BOTH LT & AMP; RT ISLES. R & R POWER SUPPLIES M33094 AND M33098 IAW WITH MM 33-51-06. OPS CHECKED NORMAL, OK TO CONTINUE.SDR CALA2012042000281Battery · dischargedFLASHLIGHT AT 1L INOP. REMOVED AND REPLACED FLASHLIGHT BATTERY AT POSITION 1L AND SECURED SAFETY SEAL, OK TO CONTINUE, OPS CHECKS NORMAL.SDR CALA2012040600238Toilet · cloggedLAVATORIES D AND H CLOGGED. REMOVED TWO FIRST CLASS TABLE CLOTHS, ONE FIRST CLASS NAPKIN AND CLEAR PLASTIC GARBAGE BAG FROM SYS IN TUBING BETWEEN STATION 1700 AND 1900. INSTALLED TUBING, OPS CHECKED GOOD. NO BUILD UP NOTICED ON TUBING WALLS.SDR CALA2012030700164Cap · damagedEMERGENCY LIGHT 3E MISSING. REMOVED AND REPLACED BROKE CAP AND ASSEMBLY. UNIT CHECKS GOOD. A/C OK TO CONTINUE.SDR CALA2012022400126Battery · dischargedFLASHLIGHT AT DOOR 4L INOP. REPLACED FLASHLIGHT BATTERY & STRAP AT 4L, CHECKS GOOD.SDR CALA2012022400125Battery · dischargedFLASHLIGHT AT DOOR 4R INOP. REPLACED FLASHLIGHT BATTERY & STRAP AT DOOR 4R. CHECKS GOOD.SDR CALA2012021300096Line · loosePOTABLE WATER QTY WENT TO ZERO DURING FLIGHT FOUND LOOSE POTABLE WATER SUPPLY LINE AT STA 825 LT. REPLACED O-RING, SECURED LINE. LEAK CHECKS GOOD.SDR CALA2012010900016Charger · inoperativeEXTERIOR EMER LIGHT AT 4L OUT. REPLACED POWER SUPPLY CHARGER M/E NR 29-3351-3-0031. TEST NORMA L PER 777-2 AMM REF 33-51-06.SDR CALA2011112900773Clutch · damagedSPEED BRAKE LEVER STUCK FULL DOWN FOUND BEARING ON AUTO SPEEDBRAKE CLUTCH MIGRATING OUT. REPLACED AUTO SPEEDBRAKE CLUTCH IAW AMM 27-62-02. ALSO FOUND LATCHED MSG 27-17001. PERFORMED FIM TASK 27-62-00-810-806. OPS TEST PASSED MSG CLEARED ROTABLE PARTS CHANGSDR CALA2011111700750Duct · tornNR 1 ENG EGT ON START AND AFTER START VERY ERRATIC TEMP SWINGS. ENG WAS RUNNING 5 MINUTES AND APPEARED TO BE GETTING HIGHER TEMP SWINGS 425 DEG TO 780 DEG FOUND FLEX DUCT FOR HPTACC TORN. PERFORMED TEMP REPAIR ON DUCT PER ECRA 7200-03038 REV A & RAN ENG AT ISDR CALA2011111100728Plug · out of positionUPON OPENING NR 2 ENGINE COWLING FOUND HPC STAGE 4 BORESCOPE PLUG "F" LAYING IN T/R HALF. REF L/P 8977608 AND L/P 8977609 FOR INSTALLATION OF BORESCOPE PLUG AND T/R THRUST LINK COVER. FOUND INSULATION BLANKET TORN AND MISSING PIECES. REPLACED INSULATION BLASDR CALA2011111000727Oven · malfunctionedSMOKE IN GALLEY, RETURNED TO TLV. SMOKE CONDITIONAL INSP. MM 05-51-58-800-801CD PERFORMED, FOUND NO TIME DUE TO LATE ARRIVAL AND INBOUND WRITE UPS EXT 118600. OVEN NR 707 IS THE SOURCE. OVEN C/B PULLED OUT AND RED COLLAR INSTALLED. OVEN 707 INOP.SDR CALA2011102800693Latch · brokenFIRE EXTINGUISHER DOOR AT 2R BROKEN - WILL NOT ALLOW DOOR TO OPEN. REMOVED UPPER LATCH OF R-2 FIRE EXTINGUISHER STOWAGE BOX. REPLACED USING MFG #SAM251-1. OP`S CHECKED GOOD.SDR CALA2011102400684Plug · missingWHILE PERFORMING T/S ON NR 1 ENG, FOUND DAMAGE ON LEFT T/R FIRE BLANKET ALSO FOUND HIGH PRESS COMPRESSOR BOROSCOPE PLUG MISSING ON LEFT SIDE (8TH STAGE VANE H.P.C ROTOR). INSTALLED REPLACEMENT BOROSCOPE PLUG (J) PER AMM 72-00-00-290 812-G00, (NOTE) FIRE BLANKSDR CALA2011101200660Unknown · malfunctionedALL LAVS FLUSH FUNCTION INOP. PERFORMED M/M TASK 20-60-01-860-801, STEP 15 (B). ALL LAVS CHECK NORMAL AT THIS TIME. OK FOR SERVICE.
Back to Boeing 777-224