Boeing 777-232
Service difficulty reports · 808
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13072467101Skin · damagedSKIN GOUGED AND DENTED APPROXIMATELY TWO FEET LONG AND .75 INCH WIDE 8 INCHES BELOW BULK CARGO DOOR. REMOVED DAMAGE IAW SRM 53-00 AND FOUND TO BE WITHIN LIMITS IAW SRM SRM 53-00-01, FIG.102, D.C HFEC IAW TABLE A OF SRM NO ITEMS.SDR DALA13072427002Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE IN AFT CABIN & R3 DOOR, DURING SERVICE CHECK. R & R BATTERY PACK M33401 IAW AMM 33-51-06-960-802, OK FOR SERVICE.SDR DALA13072437003Battery Pack · inoperativeR4 DOOR EPAS BATTERY PACK NO ARM LIGHT. R & R BATTERY PACK IAW AMM 52-11-20. OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA13070257006Fuse · failedR2 DOOR EMERGENCY EXIT SIGN INOPERATIVE. REPLACED POWER SUPPLY FUSE. CHECKED NORMAL IAW AMM 33-51. OK FOR SERVICE.SDR DALA13066957006Lamp · wrong partEMERGENCY PATH LIGHTS INOPERATIVE. FOUND INCORECT LAMPS. INSTALLED CORRECT LAMPS, REPLACED FUSE. OPS CHECKED GOOD.SDR DALA13062517006Battery Pack · inoperativeFLOOR EMERGENCY ESCAPE LIGHT INOPERATIVE ROW 10-14 ABCD. REMOVED AND REPLACED BATTERY PACK AND FUSE IN POWER SUPPLY IAW MM 33-51-06 OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA13060727002Engine · odorAT AROUND 4000 FEET DURING DESCENT, STRONG FUMES EVIDENT IN THE COCKPIT. FUMES HAD OIL AROMA. REPLACED ENGINE AND PERFORMED OIL CONTAMINATION REMOVAL IAW AMM 21-00 NO ODOR DETECTED OK FOR SERVICE.SDR DALA13059817002Fuse · inoperativeEMERGENCY PATH LIGHT INOPERATIVE. REMOVED AND REPLACED FUSE ASSY IN BATTERY PACK M33098. OPS CHECKED GOOD.SDR DALA13055787001Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE AT R1 DOOR INTERIOR AND EXTERIOR AND RT AISLE OF F/C CABIN. R & R BATTERY PACK M33094 IAW MM 33-51-06. OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA13052817007Light · malfunctionedFLT 252, DURING CRUISE, CABIN FLOOR EMERGENCY EXIT LIGHTS ILLUMINATED FOR A FEW MINUTES THEN EXTINGUISHED. NO RELATED PRESENT LEG FAULTS AND /OR EXISTING FAULTS OPS CHECK, TEST EMERGENCY LIGHT NORMAL. OK TO SERVICE.SDR DALA13047177001Battery Pack · inoperativeDURING L3 DOOR SLIDE DEPLOYMENT EPAS SYS FAILED TO OPERATE. SYS TESTED IAW AMM 52-11-20. OPS CHECKED GOOD. REMOVED AND INSTALLED SERVICABLE EPAS RESERVIOR IAW AMM 52-11-22. OPS CHECKED GOOD. REPLACED EPAS RESERVOIR IAW AMM 52-11-22, PB 401 SYS TEST NOSDR DALA13039157008Fuse · inoperativeDURING CHECK, EMERGENCY LIGHT INOPERATIVE. TROUBLESHOT IAW FIM 33-51-00 AND WDM 33-51-58. REPLACED FUSES IN M33404 POWER SUPPLY. OPS CHECKED GOOD. AMM 33-51-06. OK FOR SERVICE.SDR DALA13036357008Bottle · low pressureR2 DOOR ASSIST BOTTLE PSI LOW. R & R BOTTLE IAW AMM 52-11. OPS CHECKED GOOD.SDR DALA13034347005Cover · misinstalledLAVATORY DOOR HARD TO OPEN OR CLOSE. LOWER COVER WAS STRAIGHT AFTER REMOVAL, CORRECTLY INSTALLED AND DOOR CHECKED NORMAL TO OPEN & CLOSE IAW AMM 52-53-01.SDR DALA13032227007Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE, FROM ROW 10 THRU 14 LT AND RT SIDE ISLES. R & R POWER SUPPLY. OPS CHECKED GOOD IAW 33-51-06. OK FOR SERVICE.SDR DALA13022197003Reservoir · out of toleranceWHILE PERFORMING SERVICE CHECK, FOUND L1 DOOR EMERGENCY POWER ASSIST RESERVOIR OUT GREEN BAND. REPLACED RESERVOIR IAW AMM 52-11.SDR DALA13020607104Skin · damagedLIGHTNING STRIKE DAMAGE BS 789, STRINGER 47R. REMOVED DAMAGE IAW SRM 53-00-01.SDR DALA13013907005Fuse · blownEMERGENCY LIGHTS AT ROWS 10 THROUGH 14 LT AND RT SIDE ARE INOPERATIVE. TROUBLESHOT IAW WDM 33-51-58, FOUND BLOWN FUSE AT M33098 EMERGENCY POWER SUPPLY, REPLACED FUSE, OPS CHECKED GOOD.SDR DALA13013977002Switch · dirtyEPAS BATTERY OPERATIONAL TEST FAILED IAW AMM 52-11-20-700-803-002. TROUBLESHOOT IAW TASK 52-11-20-700-801. FOUND 3R DOOR SWITCH (S52125) WITH LOTS OF DEBRIS. CLEANED AND REINSTALLED ORIGINAL UNIT. REACTIVATED DOOR SLIDE.SDR DALA13009427104Light · inoperativeA10 CHECK, FOUND ONE EMERGENCY LIGHT OUT AT SEAT 2B. TROUBLESHOT FOUND EMERGENCY LIGHT ASSY AT FAULT REPLACED EMERGENCY PATH LIGHT ASSY AT SEAT 2B IAW AMM 33-51, OPS CHECKED OK. ACFT OK FOR SERVICE.SDR DALA13008147108Battery · failedF/C AND AFT CABIN EMERGENCY LIGHTS TIME OUT. R & R TWO BATTERIES IAW AMM 33-50, CHECKED OK.SDR DALA13006047105Skin · corrodedINTERNAL SKIN & STRINGERS CORRODED FROM BS 2268.5 TO 2344.5, STRINGERS 22 RT AND 23 RT, REMOVED DAMAGE ON SKIN AND STRINGERS. EVALUATED CLEANED AREA AND FOUND STA 2344.5- 2350 BETWEEN STRINGERS 40R AND 43R OUT OF LIMITS IAW SRM 53-00-01 (472795). ALL OTHESDR DALA13004487105Panel · damagedWING EXTENSION T/E CLOSEOUT PANEL DAMAGED. C/A REMOVED PANEL AND ROUTED TO 382 FOR REPAIR(312579). REPAIRED PANEL IAW SHOP ORDER FZ9480 NDS INSTALLED. (134146) OK TO INSTALL CLOSEOUT PANEL FOR LT WING T/E EXTENSION. INSTALLED PANEL (204965) PANEL PAINT COMSDR DALA13005177105Stringer · corrodedSTRINGER 40R FOUND TO HAVE CORROSION DAMAGE AT BS 2350. ERA 510962-14 ACCOMPLISHES PERMANENT REPAIR. ENGINEERING HAS DETERMINED THE STRUCTURE REPAIRED IAW ER/A 510962-14, REVISION ORIGINAL,SDR DALA13004057002Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE FROM ROW 10-14. BOTH SIDES. R & R BATTERY PACK & CHARGER IAW AMM 33-51. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA13002597006Battery · inoperativeDURING SERVICE CK, FOUND 4R DOOR EPAS BATTERY INOPERATIVE. C/A R & R (2) 9V BATTERIES FOR 4R EPAS BACKUP BATTERIES IAW B777 52-11. OPS CHECK GOOD AT THIS TIME.SDR DALA13000997002Fuse · blownEMERGENCY LIGHTS INOPERATIVE AT SEATS 10CB, 11CB, 12CB, 13CB, 14CB BOTH LT AND RT SIDES. TROUBLESHOT POWER SUPPLY M33098 FOUND ONE FUSE BLOWN. R & R FUSE IAW AMM 33-51-06-960-801. OPS CHECKED GOOD.SDR DALA13004817105Oil System · lowACFT DIVERTED. FLIGHT CREW INITIATED THE SHUTDOWN OF THE NR 2 ENGINE ONCE OIL QUANTITY REACHED 3 TO 2 QUARTS INDICATED AND THE SHUTDOWN WAS ACCOMPLISHED WITH POSITIVE OIL PRESSURE AND NORMAL OIL TEMPERATURE. REPLACED NR 2 ENGINE.SDR DALA13000057106Battery Pack · inoperativeR3 DOOR EPAS BATTERY STATUS LIGHT IS INOPERATIVE, NOT FLASHING GREEN WITH DOOR ARMED. REPLACED R3 DOOR EPAS BATTERY PACK. OPS CHECKED GOOD IAW AMM.SDR DALA12017057110Light · damagedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE, R & R EMERGENCY FLOOR LIGHTING IAW AMM 20-30, OPS CHECKED NORMAL.SDR DALA12017047006Fuse · inoperativeROWS 31 THRU 41 SEAT MOUNTED PROXIMITY LIGHTS INOP. POWER SUPPLY M33404, FUSE 4 AND FUSE 3 TESTED BAD WIP(801167). REPLACED FUSE, CHECKED GOOD REF 33-51-00.SDR DALA12014887005Charger · inoperativeEMERGENCY LIGHTS ROW 10-14 INOPERATIVE. R & R EMERGENCY LIGHT BATTERY CHARGER IAW AMM 33-51, CHECKED GOOD.SDR DALA12014907002Battery Pack · inoperativeZONE C, EMERGENCY EXIT LIGHTS CAME ON IN FLIGHT. CYCLED SWITCH IN COCKPIT, DID NOT HELP. EVENTUALLY WENT OUT, STAYED OUT FOR 5 HOURS. CAME BACK ON 7 HOURS INTO FLIGHT. REPLACED POWER SUPPLY & BATTERY IAW AMM 33-51. OP TESTED & OK.SDR DALA12014297002Light · inoperativeR3 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. FOUND EMERGENCY SEAT AND EMERGENCY CEILING LIGHTS INOPERATIVE ROWS 31-42 RT. PREFORMED TEST RESET OF BATTERY PACK M33404. OPS CHECKED GOOD.SDR DALA12013647002Charger · inoperativeFOUND EMERGENCY PATH LIGHTS IN ZONE C INOPERTIVE. INSPECTION FOUND CHARGER BAD R & R CHARGER IAW AMM 33-51. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA12013657105Battery Pack · inoperativeR2 DOOR EPAS BATTERY PACK GREEN TEST LIGHT NOT ILLUMINATE. REPLACED BATTERY PACK AND CHECK OK IAW AMM 52-11.SDR DALA1254517002Charger · inoperativeFIRST CLASS EMERGENCY LIGHTS GO OUT AFTER 5 SECONDS. R & R CHARGER AT DOOR 1R IAW AMM 33-51-06. EMERGENCY LIGHTS, OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA12008757005Fuse · blownOUTSIDE DOOR EMERGENCY LIGHT. REPLACED BLOWN FUSES. OPS CHECKED OK.SDR DALA12008767005Fuse · failedEMERGENCY LIGHT INOPERATIVE. REPLACED TWO BLOWN FUSES IN POWER SUPPLY. OPS CHECKED NORMAL IAW AMM 33-51-06. OK FOR SERVICE.SDR DALA12004537003Power Supply · inoperativeEMERGENCY LIGHTS AT ROWS 12, 13, 14 DO NOT WORK. REPLACED POWER SUPPLY PER AMM 33-52. OPS CHECKED GOOD.SDR DALA12004097007Battery · inoperativeEMERGENCY POWER ASSIST SYSTEM AT L3 DOOR FAILED TEST. REPLACED BATTERY AS PER AMM52-11-20-401. OPS CHECKED GOOD.SDR DALA12004087007Battery · inoperativeEMERGENCY POWER ASSIST SYSTEM AT R1 DOOR FAILED TEST. REPLACED BATTERY AS PER AMM 52-11-20-401. OPS CHECKED GOOD.SDR DALA12004077007Battery · inoperativeEMERGENCY POWER ASSIST SYSTEM AT L4 DOOR FAILED TEST. REPLACED BATTERY AS PER AMM 52-11-20-401. OPS CHECKED GOOD.SDR DALA12004067007Battery · inoperativeEMERGENCY POWER ASSIST SYSTEM AT R4 DOOR FAILED TEST. REPLACED BATTERY AS PER AMM 52-11-20-401. OPS CHECKED GOOD.SDR DALA12003537003Battery Pack · inoperativeDURING SERVICE CHECK, EMERGENCY ESCAPE PATH LIGHTS FAILED TEST AT ROWS 10 THRU 14. REPLACED BATTERY SUPPLY M33098 AS PER AMM 33-51-06-960-802. OPS CHECKED GOOD.SDR DALA12002317005Power Supply · inoperativeEMERGENCY PATH LIGHTS ROWS 31 THRU 42 INOP. REPLACED POWER SUPPLY AT DOOR 3R PER MM33-51-06. OPS CHECK GOOD.SDR DALA13029657007Skin · damagedPOSSIBLE LIGHTNING STRIKE, BS 2118 S5-30R. REMOVED DAMAGED AREA OF FUSELAGE SKIN IAW PRI 504672-14, REV O. PERFORMED HFEC OF CUTOUT IAW NDT 51-00-00, PART 6 NO DEFECTS NOTED. FABRICATED REPAIR PARTS IAW SRM 53-00-01, REPAIR 4. TREATED & PAINTED REPAIR PARSDR DALA12002277003Battery Pack · inoperativeEMERGENCY LIGHTS AT SEAT ROWS 10 THRU 14 ONLY CAME ON FOR 3 SECONDS DURING TEST. REPLACED BATTERY PACK (M33098) PER MM33-51-06.SDR DALA13029667007Skin · damagedPOSSIBLE LIGHTNING STRIKE, BS 2115 S29R. REMOVED DAMAGED AREA OF SKIN IAW SRM 53-00-01 REPAIR NR 4. PERFORMED HFEC OF CUTOUT IAW NDT 51-00-00 PRT 6, NO DEFECTS NOTED. FABRICATED REPAIR DOUBLER IAW SRM 53-00-01 REPAIR NR 4.SDR DALA13029687007Skin · damagedLIGHTNING STRIKE AT BS 2067 S30R. INSTALLED FASTENER IAW SRM 53-00-01, REPAIR 8.
Back to Boeing 777-232