Boeing 777-232
Service difficulty reports · 808
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13029677007Skin · damagedLIGHTNING STRIKE DAMAGE FOUND AT BS 2018 AND JUST BELOW STRINGER 4. REPAIRED IAW SRM 53-00-01, REPAIR 4 .SDR DALA12001447001Fuse · inoperativeEMERGENCY LIGHT ARE INOPERATIVE AT ROWS 10 THRU 14. REPLACED POWER SUPPLY FUSES PER AMM 33-51-06-960. OPS CHECKED GOOD.SDR DALA2015010800143Skin · damagedDURING WALK AROUND, HOLES IN FUSELAGE IN BS 330, STRINGER 25.SDR DALA1220687001Battery · inoperativeDURING MAINTENANCE VISIT, THE 3L EPAS BATTERY WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY WAS REPLACED.SDR DALA1214067003Battery · dischargedDURING A MAINTENANCE VISIT, THE 2L EPAS BATTERY WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY WAS REPLACED.SDR DALA1212797003Wire · exposedDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR LIGHTING WIRES WERE EXPOSED AT DOOR 3L BULKHEAD. MAINTENANCE REPAIRED THE EMERGENCY FLOOR LIGHTING PER BSWP CHAP 20. OP CKS GOOD PER B777-200ER. (2012-D0227)SDR DALA1210027001Fuse · openDURING CHECK, MAINTENANCE FOUND THE EMERGENCY PATH LIGHTS AT ROWS 31 TO 42 LEFT AND RIGHT INOPERATIVE. MAINTENANCE REPLACED A POWER SUPPLY FUSE. OPS CHECKED GOOD.SDR DALA1208587003Wire · looseEMERGENCY EXIT LIGHT ON CROSS OVER AISLE BETWEEN DOORS 3L AND 3R POPPED OUT OF BULKHEAD WITH LOOSE WIRES. RE-TERMINATED WIRE. RESTOWED, OPS CHECK GOOD PER B777 AMM20-20.SDR DALA1208187003Charger · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY LIGHTS AT SEATS 10BC TO 13BC WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE BATTERY CHARGER AT 2R AFT INOPERATIVE AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY CHARGER WAS REPLACED.SDR DALA1204397007Sensor · faultyDIV, FLT 295 NRT LEFT PACK INOPERATIVE INFLIGHT AT 32000 FT. FLIGHT DIVERTED TO DTW DUE TO LEFT PACK CYCLING. LEFT LOWER PACK FLOW CONTROL VALVE AND LEFT PACK FLOW CONTROL SENSOR WAS REPLACED. ETOPS CATEGORY 'B': DIVERSION OR TURNBACKSDR DALA1203727004Battery Pack · dischargedDURING A MAINTENANCE VISIT, THE 4L DOOR EMERGENCY LIGHT OF POWER SUPPLY WAS FOUND TO BE WEAK. MAINTENANCE REPLACED THE BATTERY PACK. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY PACK WAS REPLACED.SDR DALA1515797006Skin · dentedNR 4 FLAP UPPER SURFACE DENTED. REPAIRED IAW SRM 57-53-01, AND SRM 51-70-04.SDR DALA1171347003Power Supply · inoperativeMAINTENANCE FOUND B ZONE EMERGENCY LIGHTS INOP. POWER SUPPLY REMOVED AND REPLACED PER AMM 33-51-06.SDR DALA1170947004Light · missingSEAT 5B EMERGENCY LIGHT MISSING LENS AND BULB. SEATS 10BC-1414BC EMERGENCY AISLE LIGHTS INOPERATIVE. RELAMPED SEAT 5B. REPLACED CHARGER AND BATTERY M33098. SEATS 10BC-14BC CK OK.SDR DALA1170457005Fuse · blownDURING A MAINTENANCE VISIT, THE EMERGENCY ESCAPE PATH LIGHT AT ROWS 10-14 ABCD WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE FUSE ON THE BATTERY PACK. SYSTEM OPERATION WAS NORMAL AFTER THE FUSE WAS REPLACED.SDR DALA1170447001Battery Pack · dischargedDURING A MAINTENANCE VISIT, THE EMERGENCY DOOR EXIT LIGHT BATTERY AT DOOR 4L WAS FOUND TO BE WEAK. MAINTENANCE REPLACED THE BATTERY PACK. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY PACK WAS REPLACED.SDR DALA1170437001Battery Pack · dischargedDURING A MAINTENANCE VISIT, THE EMERGENCY DOOR EXIT LIGHT BATTERY AT DOOR 3R WAS FOUND TO BE WEAK. MAINTENANCE REPLACED THE BATTERY PACK. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY PACK WAS REPLACED.SDR DALA1169767003Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHT AT SEAT 13C WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE PROXIMITY LIGHT ASSEMBLY. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT ASSEMBLY WAS REPLACED.SDR DALA1169567005Fuse · blownDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHTS IN CABIN ZONE B WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK FUSES. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY PACK FUSES WERE REPLACED.SDR DALA1169557004Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHT AT SEAT 12B WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE PROXIMITY LIGHT ASSEMBLY. SYSTEM OPERATION WAS NORMAL AFTER THE LIGHT WAS REPLACED.SDR DALA1167107008Pin · not seatedDURING A MAINTENANCE VISIT, THE OVERHEAD EXIT EMERGENCY SIGN AT DOOR 1L WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE PUSH PIN AT THE CONNECTOR DISCONNECTED AND RESEATED IT. SYSTEM OPERATION WAS NORMAL AFTER THE PIN WAS RESEATED. (2011-D1392)SDR DALA1163547007Light · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY FLOOR PROXIMITY LIGHTS AT SEATS 10B, 10C AND 12B WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE FLOOR PROXIMITY LIGHT ASSEMBLY. SYSTEM OPERATION WAS NORMAL AFTER THE FLOOR PROXIMITY LIGHTS WERE REPLACED.SDR DALA1163407006Power Supply · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY EXIT SIGN AT DOOR 3R WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY. SYSTEM OPERATION WAS NORMAL AFTER THE POWER SUPPLY WAS REPLACED.SDR DALA1156867006Fuse · brokenDURING A MAINTENANCE VISIT, DOOR 2R SLIDE LIGHT AND FORWARD ZONE 2 EMERGENCY FLOOR PROX LIGHT WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE FUSE 2 BROKEN AND REPLACED IT. MAINTENANCE ALSO REPLACED M33098 POWER SUPPLY. SYSTEM OPERATION WAS NORMAL AFTERSDR DALA1154677007Fuse · blownDURING A MAINTENANCE VISIT, THE EMERGENCY LIGHTS AT ROWS 31DF THROUGH 42DF WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND A BAD FUSE IN THE BATTERY PACK AND REPLACED M33404 NR 4 PER B777 AMM 33-50. SYSTEM OPERATION WAS NORMAL AFTER M33404WAS REPLACED.SDR DALA1148197001Battery Pack · dischargedCREW REPORTED EMERGENCY LIGHTS OUT FROM SEAT 44-57 ON LEFT AND RIGHT SIDES. REPLACED BATTERY PACK (M33401) AND POWER SUPPLY.SDR DALA1143077005Wire Harness · dischargedEMERGENCY LIGHTS AT SEAT 5C WAS FOUND TO BE INOPERATIVE. MAINTENANCE RE-CONNECTED THE HARNESS AND OPERATION RETURNED TO NORMAL.SDR DALA1142917008Light · inoperativeDURING THE WALK AROUND INSPECTION TWO EMERGENCY LIGHTS WERE FOUND INOPERATIVE AT SEATS 10B AND 14B. MAINTENANCE REPLACEDTHE LIGHT ASSEMBLY AND A BLOWN FUSE FOUND AT BATTERY PACK M33098. OPERATION CHECKS NORMAL.SDR DALA14004127103Skin · damagedFUSELAGE SKIN, BS 615, BETWEEN S35-36R GOUGED AND DENTED,SDR DALA1131107006Socket · shortedDURING A MAINTENANCE VISIT, THE EMERGENCY TRACK LIGHTS ALONG BUSINESS ELITE SEATS ROW 10-14 ON THE LEFT AND RIGHT AISLE WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE LEFT SOCKET AT SEAT 11B SHORTED AND BLOWING THE FUSES AND REPLACED IT. SYSTEM OPERATIOSDR DALA1130097005Skin · damagedLIGHTNING STRIKE AT STA 236 AT 36R HAS 3 SPOTS THAT NEED TO BE REPAIRED. REPAIRED PER ERA 492206-14 REV B.SDR DALA1130087007Skin · crackedFOUND L4 DOOR OUTER SKIN LWR AFT CORNER BENT AND CRACKED REPAIRED L4 DOOR IAW ERA 489082 -14.SDR DALA1130067007Skin · dentedFOUND DENT IN FUSELAGE OUT OF LIMITS AT STA 2040 BETWEEN S-39R AND S-40R. REPAIRED DENT IAW ERA 489083-14 REV O.SDR DALA1128547109Fuse · failedDURING A MAINTENANCE VISIT, THE EMERGENCY LIGHT IN BUSINESS CLASS, FORWARD LOWER SECTION WAS FOUND INOPERATIVE. MAINTENANCE FOUND FUSE 3 IN BATTERY PACK M33094 BAD AND REPLACED IT. SYSTEM OPERATION WAS NORMAL AFTER THE FUSE WAS REPLACED. (2011-D0510)SDR DALA1128517002Charger · inoperativeDURING A MAINTENANCE VISIT, THE EXTERIOR LIGHT AT DOOR 4R WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY CHARGER. SYSTEM OPERATION WAS NORMAL AFTER THE BATTERY CHARGER WAS REPLACED.SDR DALA1122477001Power Supply · inoperativeDURING A MAINTENANCE VISIT, THE EMERGENCY LIGHTS AT SEATS FORWARD MOST SECTION OF TOURIST CLASS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED POWER SUPPLY M33404. SYSTEM OPERATION WAS NORMAL AFTER THE POWER SUPPLY WAS REPLACED.SDR DALA1112657008Battery Pack · dischargedDURING A MAINTENANCE VISIT, THE EMERGENCY CABIN LIGHTS FROM BATTERY PACK M33400 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED THE CHARGER AND BATTERY PACKS M33400 AND M33405 AND INSTALLED CHARGER AND BATTERY SERIAL NUMBER 25185AT M33400 AND SERIAL NUMBER SDR DALA1106807005Slat Track · looseDURING INSPECTION OF SLAT DOWNSTOPS IAW EA 11-469704-03 AD, ME 01 AND ME 02 FOUND NR 4 SLAT OTBD TRACK ALSO NR 5, SLAT OTBD TRACK AND NR 9 SLAT OTBD TRACK BOLT LOOSE. REPLACED FASTENERS IAW EA 11-469704-03, AD, ME 09 AND ME 10.SDR DALA1052787004Power Supply · inoperativeDURING EMERGENCY LIGHT TEST FOUND LIGHTS INOPERATIVE, ROW 10 THROUGH 13. REPLACED POWER SUPPLY ABOVE DOOR 2R AND TESTS OK.SDR DALA1052887001Light · brokenDURING EMERGENCY LIGHT TEST FOUND DOOR 1R EXIT LIGHT BROKEN, REPLACED LIGHT AND CHECKS OK.SDR DALA1034137001Structure · damagedLOWER AFT CORNER OF L4 DOOR DAMAGED REPAIRED IAW ERA 486782-14, REV ORG.SDR DALA1013040867Unknown · odorENROUTE F/A REPORTED ELECTRICAL ODOR IN AFT GALLEY. IT WAS UNKNOWN IF ANY PRECAUTIONARY ACTION WAS TAKEN. FLIGHT CONTINUED ON TO PVG WHERE MX DEFERRED THE OVEN AND WILL REPLACE IT AT A LATER TIME. (DL777101496)SDR DALA1012890867Oven · odorRTB FOR BURNING SMELL IN AFT CABIN T/S FOUND SMELL FROM CTR OVEN. PULL COLLAR C/B. FWD TO NEF PROGRAM 253.30. PLACARD INSTALLED. (DL777101468)SDR DL777100501Fan · failedODOR IN AFT CABIN FOUND RT LWR RECIRCULATION FAN FAILED. ETOPS CATEGORY 'E': PROBLEMS WITH SYS CRITICAL TO ETOPS.SDR DL777100464Fan · overheatedF/A REPORTED BURNING RUBBER ODOR IN AFT GALLEY AREA. SHUTOFF OVENS, LIGHTS, IFE, RECIRC FANS. ODOR DISSAPATED. TURNED LIGHTS BACK ON AND STILL NO SMELL. T/S SYS. CHECKED LIGHTS OVENS IFE AND RECIRC FANS. FOUND LATCHED MSG FOR LOWER RT RECIRC FAN OVERHEATEDSDR DL777100187Battery Pack · dischargedBATTERY PACK FAILS CAPACITY TEST. REPLACED 3 BATTERY PACKS FOR SEAT ROWS 10-41 OPS NOW CK NML.SDR DL777100143Connector · brokenEMERGENCY LIGHT AT SEAT31F INOP. REPAIRED BROKEN CONNECTOR OP CK GOOD.SDR DL777100056Chiller · inoperativeIR - MIDGALLEY AFT CHILLER INOPERATIVE. OVERHEAT LT ON WITH ELECTRICAL ODOR. C/BS PULLED AND COLLARED.SDR DL777100046Engine · making metalINBD WRITEUP OF RT ENG VIB MONITOR MESSAGE. PEFORMAMCE PAGE SHOW HIGH N2 VIBS THEN N2 VIBS DECREASED AND N1 VIBS INCREASED WITH OIL QTY DROP. FOUND METAL ON MCD AND IGB CHIP DETECTOR PORT. NR 2 ENG CHANGE IN PROGRESS. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRSDR DL777092022Antenna · failedIRREG WEATHER RADAR FAILED. R & R WX ANTENNA DRIVE UNIT IAW MM. ALL TEST OK LRU REPLACEMENT TEST OK IAW MM. OK FOR SERVICE. BORROWED PART, MFG P/N 622-5136-202. ETOPS CATEGORY 'B': DIVERSION OR TURNBACK.
Back to Boeing 777-232