Boeing 777-300ER
Service difficulty reports · 456
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025081807863Unknown · odorFLT ATTDNT CREW REST HAS SULFUR ODOR NEAR ENTRY DOOR. CONDITION AIR SUPPLIED WITH COOLING PACK IAW AMM 21-00-00-800-803 REV.104, INSPECTION PERFORMED AT AFT CABIN AREA AROUND FLT ATTEND CREW REST, NO SULFUR OR ELECTRIC ODOR AFTER HALF AN HOUR OF PACK OPS. FOSDR CALA2025080507336Smoke Detector · false activationUPPER CREW REST SMOKE DETECTOR ACTIVATED AFTER SHIP POWER TRANSFER. SMOKE ALARM TRIGGERED BY POWER TRANSFER, COMMON ON 777. ACCOMPLISHED CABIN SYSTEM ALL TEST, ALARM EXTINGUISHED AND NO FAULTS. INSPECTED CREW REST AND ALLOWED APRX. 2 HOURS WITH NO SMOKE OR ODSDR CALA2025080507300Bracket · brokenFOUND CAPTAIN SIDE EMERGENCY FLASHLIGHT BRACKET BROKEN REPLACED BRACKET AND CHECKED OKAY. CHECKED OK.SDR CALA2025071506580Light · brokenSEAT 48G AISLE EMERGENCY LIGHT BROKEN REPLACED LIGHT ASSEMBLY AND OPERATION CHK OK. REPLACED LIGHT ASSEMBLY AND OPERATION CHK NORMAL.SDR CALA2025071606622Seal · faultedNR 1 ENGINE HAS EXPERIENCED AN INCREASE IN OIL CONSUMPTION. ACCOMPLISH A SNIFF CHECK OF OIL FOR FUEL ODOR, IAW AMM 12-13-01-130-803-002, STEP F.(1). ACCOMPLISH FIM 71-05 TASK 805, STEPS D.(1) TO D.(4) TO TROUBLESHOOT FOR HOC. PERFORMED TEST NR 6, PART POWER SDR CALA2025070306176Battery Pack · dischargedDOOR 4L EMER LIGHT EXIT SIGN DOESN'T WORK IAW AMM 33-51-06. REPLACED EMER LIGHT BATTERY PACK, FUNCTION CHK ALL EMER LIGHTS WORK.SDR CALA2025062305797Unknown · odorACRID SMELL IN PILOT CREW REST. SMOKE DETECTOR WENT OFF. PERFORMED SMOKE/ODOR IN THE FLIGHT DECK/CABIN CONDITIONAL INSPECTION IAW AMM 05-51-58-800-801-C3 REV. 104. / NIL FINDINGS. NO SOURCE OF SMOKE/ODOR OR FIRE DETECTED.SDR CALA2025062305803Fuse · openEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - FOUND DOOR 4 FWD ZONE EMERGENCY LIGHT INOP. REPLACED BATTERY PACK, FUSE AND SEAT 50D EMERGENCY LIGHT MODULE, AND EMERGENCY LIGHT OPERATION CHECK NORMAL.SDR CALA2025062005729Slide · low pressureWHILE PERFORMING #2 SVC CHECK FOUND L4 DOOR SLIDE PRESSURE OUT OF LIMITS REF AMM 25-66-01-200-801. L4 DOOR SLIDE NIS IN EWR, REF IPC 25-66-01-04A ITEM (50) P/N 63604-339 (M/E 23-2566-9-0002) REMOVED AND REPLACED L4 EMERGENCY ESCAPE SLIDE AS PER MM TASK 25-SDR CALA2025061705605Bottle · low pressureDOOR 4L SLIDE PRESSURE REPORTED BY CREW TO BE IN RED, BAND. ACCOMPLISHED DOOR 4L SLIDE PRESSURE INDICATION REF. TASK 25-66-01-200-801 ,NEDDLE TOUCHING GREEN AREA.SDR CALA2025061605567Proximity Sensor · failedDOOR WING SLIDE L EICAS STATUS LEFT DOOR WING SLIDE PROXIMITY SENSOR FAILURE. INTERMITTENT DOOR WING SLIDE L ADV DURING CRUISE NO STATUS MSSG PRESENT AND NO CORELATED MSSG AND NO HISTORY FOUND. ADD EMP: U416150SDR CALA2025060505284Toilet · odorTOILET BOWL SMELLS BAD DR-2L AFT LAV NOTIFIED CLEANERS OF SMELLY LAV, DR2 AFT. RAN VINEGAR THROUGH ALL LAVS ON LH SIDE OF AIRCRADT AS PRECAUTIONARY, OK FOR SVC AT THIS TIME. REF AMM 38-32-00SDR CALA2025060305208Warning Message · illuminatedSTATUS MSG. DOOR WING SLIDE LK L SHOWING ON EICAS DISARMED 3L O/W ESCAPE SYSTEM. REF. AMM 25-65-00-040-801. OPENED 3L O/W SLIDE COMPARTMENT DOOR. REF. AMM 25-65-10-010. CLOSED O/W COMP. DOOR. REF. AMM 25-65-10-400-801. EICAS MESSAGE CLEARED. ARMED 3L O/W SLIDESDR CALA2025050604491Battery Pack · expiredEMER FLASH LT 15 EA SERVICE LIFE DATE LESS THAN 135 DAYS THE FLASH LT BATTERY AT FLIGHT DECK CA SIDE, DR 1L AFT, DR 1R, DR 2R FWD&AFT, DR 2L FWD&AFT, DR 3R, DR 4L, DR 4R, DR 5L, DR 5R*2, OFCR, OFAR SERVICE LIFE LESS THAN 135 DAYS, RPL BATTERY AND OPT CHK NML. SDR CALA2025050704526Safety Wire · incorrectRIGHT NLG WHEEL RIM TIE BOLTS SAFETY WIRED INCORRECTLY. TIRE SHOP SAFETIED FUSE PLUGS INCORRECTLY. SEE PICTURES. UPDATED PICS REPLACED SAFETY WIRE ON RIGHT NLG RIM TIE BOLTS . REF AMM SUBTASK 32-45-03-210-001. AS REQUSTED BY THE FAA, SUBMITTING SDR FOR FINDINGSDR CALA2025043004335Battery · dischargedDR R3 EMER LT BATTERY PACK M33303 CAPACITY LOW. L3 DOR EMERGENCY LIGHT POWER PACK M33303 FOUND CAPACITY LOW DR L3 EMER LT BATT PACK M33303 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2025043004334Battery · dischargedDR R5 EMER LT BATTERY PACK M33408 CAPACITY LOW. DR R5 EMER LT BATT PACK M33408 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2025043004333Battery · dischargedDR R1 EMER LT BATTERY PACK M33094 CAPACITY LOW . DR R1 EMER LT BATT PACK M33094 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2025043004332Battery · dischargedDR R5 EMER LT BATTERY PACK M33409 CAPACITY LOW. R5 DOOR EMERGENCY LIGHT POWER PACK M33409 FOUND CAPACITY LOW DR R5 EMER LT BATT PACK 1U33409 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2025043004331Battery · dischargedDR R3 EMER LT BATTERY PACK M33306 CAPACITY LOW. R3 DOOR EMERGENCY LIGHT POWER PACK M33306 FOUND CAPACITY LOW DR R3 EMER LT BATT PACK M33306 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2025043004330Battery · dischargedDR L1 EMER LT BATTERY PACK M33093 CAPACITY LOW. DR L1 EMER LT BATT PACK M33093 REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06 .SDR CALA2025042504229Packing · damagedLOW OIL QTY LEFT ENG. 1 QT REMAINING INFO - CAP REPORTED " SHUT THE ENG DOWN ABOUT 1 HOUR 20 MINUTES PRIOR TO LANDING. THAT'S HOW LONG THE WINDMILLING WAS, SHUT IT D OWN AT 10 PSI. OIL PRESSURE AFTER SHUT DOWN WAS 4 PSI ". WRENCH CHECK CARRIED OUT TO FROM OIL SDR CALA2025042804255Battery Pack · dischargedEMERGENCY FLASHLIGHT BATTERY DATE CHECK - VISUAL CHECK (ADDED BY EC0300-01598) PROCEDURE - REPLACE ALL EMERGENCY FLASHLIGHT BATTERIES EXCEPT POSITION 4L, 5L, AND 3L BECAUSE MANUFACTURE EXPIRATION DATE LESS THAN SLM LIMITE. REPLACE THESE EMERGENCY FLASHLIGHT BASDR CALA2025042404194Battery · dischargedDR R2 M33098 EMER LT BATTERY PACK CAPACITY CHECK FAILED. DR R2 M33098 EMER LT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM33-26-00.SDR CALA2025042404191Battery · dischargedSUPPORT TASK - OFAR M33143 EMER LT BATTERY PACK CAPACITY CHECK FAILED. EMER LT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2025042404190Battery · dischargedSUPPORT TASK - DR R3 M33305 EMER LT BATT PACK CAPACITY CHECK FAILED. REPLACED EMER LIGHT BATTERY AT DR R3 M33305 AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2025042204127Battery Pack · dischargedDR L3 EMER PWR BATTERY PACK M33302 CAPACITY LOW. DR L3 EMER PWR BATTERY PACK M33302 REPLACED AND CARRIED OUT INSTALLATION TEST WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4545065).SDR CALA2025042204126Battery Pack · dischargedDR 1 RH EMER PWR BATTERY PACK M33094 CAPACITY LOW. DR 1 RH EMER PWR BATTERY PACK M33094 REPLACED AND INSTALLATION TEST HAS BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4545015).SDR CALA2025042204125Battery Pack · dischargedDR 2 LH EMER PWR BATTERY PACK M33096 CAPACITY LOW. DR 2 LH EMER PWR BATTERY PACK M33096 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544821).SDR CALA2025042204124Battery Pack · dischargedDR 5 OVERHEAD CREW REST EMER PWR BATTERY PACK M33142 CAPACITY LOW. DR 5 OVERHEAD CREW REST EMER PWR BATTERY PACK M33142 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544747).SDR CALA2025042204121Battery Pack · dischargedDR R5 EMER PWR BATTERY PACK M33408 CAPACITY LOW. DR R5 EMER PWR BATTERY PACK M33408 REPLACED AND INSTALLATION TEST HAS BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4545121).SDR CALA2025042204120Battery Pack · dischargedDR R4 EMER PWR BATTERY PACK M33401 CAPACITY LOW. DR R4 EMER PWR BATTERY PACK M33401 REPLACED AND INSTALLATION TEST HAD BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4543695).SDR CALA2025042204119Battery Pack · dischargedDR R4 EMER PWR BATTERY PACK M33404 CAPACITY LOW. DR R4 EMER PWR BATTERY PACK M33404 REPLACED AND INSTALLATION TEST HAS BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544848).SDR CALA2025042204118Battery Pack · dischargedDR L4 EMER PWR BATTERY PACK M33400 CAPACITY LOW . DR L4 EMER PWR BATTERY PACK M33400 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544899).SDR CALA2025042204116Battery Pack · dischargedDR R3 EMER PWR BATTERY PACK M33304 CAPACITY LOW. DR R3 EMER PWR BATTERY PACK M33304 REPLACED AND CARRIED OUT INSTALLATION TEST WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544964)SDR CALA2025041403789Slide · no testEMERGENCY ESCAPE SLIDE - INSPECTION PROCEDURE - FOUND DR-1R MFG S/N: M10389 ESCAPE SLIDE LIFE LESS THAN 405 DAYS REMAIN ON OVERHAUL DUE DATE. DOOR 1R EMERGENCY ESCAPE SLIDE OVERHAUL DATE IS 28AUG2025 LESS THAN 405 DAYS LIMIT REQUIRE, REQUEST DIP 1R ESCAPE SLIDSDR CALA2025040903654Warning Message · false activationDOOR BULK CARGO EICAS ADVISORY BULK CARGO DOOR NOT FULLY CLOSED, LATCHED AND LOCKED. PRESSURIZATION NORMAL NO "DOOR BULK CARGO" ADVISORY MESSAGE PRESENT. ALSO, NO CORRELATED FAULTS IN FAULT HISTORY OR EXISTING FAULT. BULK CARGO DOOR LATCH PROBE AND CLOSED SWISDR CALA2025032803296Sensor · faultedREF LOG. PGS. 4283873 AND 4283765. FOUND FAULT 36-10325. FOUND SHOP FAULTS: FAULT NUMBER 43, SHOP DATA "GH" AND MANIFOLD PRESS WAS "M005" PSI. T-S REF AMM LEFT (RIGHT) FAMV FAILED CLOSED - FAULT ISOLATION, REF: 36-11 TASK 809. ACP'D STEPS G-1-A TO L. ACP'D HEASDR CALA2025032603207Smoke Detector · false activationSMOKE DETECTED & INDICATION FAULT MESSAGE SHOWS ZONE B SMOKE DETECTED SHOWS ON ALL FA DISPLAY PANEL NO FAIL INDICATED IN CPT PEFORMED FIM TASK 811 AND EXAMINED ALL LAVS AND CREW REST AREA, NO FAULTS FOUND. SMOKE DETECT DETECTION FAULT DOES NOT SHOW ON.SDR CALA2025032003000Battery Pack · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - FOUND BATTERY PACK M33406 INOP. RELATED EMERGENCY LT INOP OVER DOOR AREA, MAIN AISLE, MED 4L EXIT SIGN & MASTER CALL EXIT SIGN MED L& R. REF SSM 33-51-15-103. REPLACED WITH A NEW BATTERY PASDR CALA2025032002993Battery Pack · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - FOUND LH #3 DOOR OVERWING SLIDE LT INOP. REPLACED PWR PACK ON M33301 EMER PWR SUPPLY AND FUNCTION CHKD ON. PARTS USED: 99-3351-3-0015, QTY :1SDR CALA2025031402811Engine · oil consumptionE2 ESN 901206 HAS EXPERIENCED AN INCREASE IN OIL CONSUMPTION. A CCOMPLISH A SNIFF CHECK OF THE OIL FOR FUEL SMELL IN THE OIL SYS TEM, REF. AMM 12-13-01-130-803-002 STEP F.(1). ACCOMPLISH FIM 71 -05 TASK 805 STEPS D.(1) TO D.(4) TO TROUBLESHOOT FOR HOC. ALSO PSDR CALA2025031102694Fuse · failedLH #4 DOOR SLIDE EMERGENCY LT INOP. REPLACED FUSE ON EMER PWR SUPPLY(M33405) AND CHKD OK.SDR CALA2025031100484Battery · dischargedSUPPORT TASK - DR1 LH EMER PWR PACK (M33093) CAPACITY LOW. DR1 LH EMER PWR PACK (M33093) REPLACED AND TEST NORMAL AS PER AM M 33-51-06.SDR CALA2025031102698Lamp · inoperativeLH #3 DOOR OVERWING SLIDE EMERGENCY LIGHT (L33239) INOP. RELAMPED AND CHKD OK. PER AMM 33-52-04-960-801.SDR CALA2025031102697Battery Pack · faultedDOOR 2R 3L 4R AND DOOR 5 AFT GALLY JUMP SEAT EMERGENCY FLASHLIGHT BATTERY LIFE LESS THAN 135 DAYS REPLACE BATTERY, PACK, LED LIGHT AND CHK FUNCTION NML. REPLACE BATTERY, PACK, LED LIGHT AND CHK FUNCTION NMLSDR CALA2025022702499Battery Pack · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - FOUND THE DOOR 4L 3EA EMER AREA LT MAIN AISLE NOT WORKING. R/R THE NEW BATTERY PACK AND OPCK NML PER A.M.M 33-51-06-960-802. REPLACED THE BATTERY & OPS CKD OK.SDR CALA2025022402462Battery Pack · no testSEAT ROW 52 TO 57 EMERGENCY LIGHT POWER PACKS CHECK LESS THAN MINIUM 15 MINUTES. PERFORM TROUBLESHOOTING AND PER AMM 33-51-06-960-802 REPLACED THE POWER PACK AT 5R DOOR , AND PER AMM 33-51-06-200-801 POWER PACK OPERATIONAL CHECK NORMAL. PERFORM TROUBLESHOOTINSDR CALA2025022402419Battery Pack · no testCCA CHK FOUND FO SIDE EMERGENCY FLASHLIGHT NO TEST. REPLACED BATTERY AND TESTED FOUND GREEN LIGHT.PARTS USED: 78-2525-3-0058, QTY :1SDR CALA2025022402434Skin · damagedSKIN WAVINESS - EXAMINATION (AT THE STATIC PORTS) SKIN WAVINESS EXAMINATION - L/H FUSELAGE FOUND DENT BETWEEN LEFT AND RIGHT STATIC PORTS.MEASURED DENT JUST FWD OF AIRCRAFT LEFT- AFT STATIC PORT AT STATION BS 764 AND WL139. DENT MEASURED 1.625 " X 1.50" ; DEPT
Back to Boeing 777-300ER