Boeing 777-300ER
Service difficulty reports · 456
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025122112279Light · malfunctionedFA REPORTED CABIN EMERGENCY LIGHT ON FOR FEW MINS THEN OFF WITHOUT MOVING SWITCH. PERFORMED EMERGENCY LIGHTS OPS TEST BY TEST SWITCH IAW TASK 33-51-00-710-802, REV NO. ALL LIGHTS NORMAL TURNED ON AND OFF AUTOMATICALLY.SDR CALA2025121812215Fmc · failedSHORTLY AFTER T/O L FMC FAILURE. ACCOMPLISHED NON-NORMAL. NO HEL P FMC AND DISPLAY UNIT ORDERED TO B29. NO FMC FAULTS AT CURRENT TIME OR IN RECENT HISTORY. ACOMPLISHED FMC OPERATIONAL TEST AND SYSTEM TEST REF AMMS 34-61-00-710-801 AND 34-61-00-730-801. INCLUDISDR CALA2025121212079Valve · faultedNR 1 ENGINE IS EXPERIENCING AN INCREASE IN OIL CONSUMPTION. PE RFORM A VISUAL INSPECTION THE SUBJECT ENGINES EDUCTOR VALVE. BE SURE TO CHECK THE AIR LINE THAT RUNS ALONG THE VALVE TO SEE IF THERE ARE ANY INDICATIONS. IAW AMM 79-21-17/401 FOR LOCATION OF THE EDSDR CALA2025121012016Battery Pack · no testPOWER SUPPLY BATTERY PACK CAPACITY CHECK PROCEDURE, DURING EMERGENCY LIGHT FUNCTION CHK, FOUND BATTERY PACK FUNCTION LESS THAN 15 MIN AT DOOR 5R M33409. REPLACED A NEW BATTERY PACK IN M33409 POSITION AND CHK FUNCTION NORMAL IAW AMM 33-51-06.SDR CALA2025120911930Packing · leakingENGINE HAS EXPERIENCED AN INCREASE IN OIL CONSUMPTION. ACCOMPLISHED A SNIFF CHECK OF OIL FOR FUEL ODOR IN THE OIL SYS, IAW AMM 12-13-01-130-803-002, STEP F.(1). ACCOMPLISH FIM 71-05/805 TO TROUBLESHOOT FOR HOC. PERFORM TEST NR 6. POWER LEAK CHECK WITH ALL DSDR CALA2025120211702Light · inoperativeEMER FLOOR PROXIMITY LIGHT INOP AT SEAT 31D, 49G, 53G, 54D, AND 54G. R/R LIGHT ASSY AND OPERATIONAL TEST GOOD REF WITH TO AMM 33-51-05-960-802.PARTS USED: 99-3350-3-0008, QTY :4SDR CALA2025112811560Battery · no testOFCR EMERGENCY POWER SUPPLY BATTERY PACK 1 (M33118) FAIL TEST. BATTERY PACK REPLACED. INSTALLATION TEST CARRIED OUT FOR BATTERY PACK (M33118) IAW AMM33-51-00, FOUND WORKING SATISFACTORY.SDR CALA2025112811558Battery · no testOFCR EMERGENCY POWER SUPPLY BATTERY PACK 2 (M33145) FAIL TEST. BATTERY PACK REPLACED. INSTALLATION TEST CARRIED OUT FOR BATTERY PACK (M33145) IAW AMM 33-51-00,FOUND WORKING SATISFACTORY.SDR CALA2025112811556Battery · no testOFCR EMERGENCY POWER SUPPLY BATTERY PACK RH (M33142) FAIL TEST. BATTERY PACK REPLACED. INSTALLATION TEST CARRIED OUT FOR BATTERY PACK (M33142) AS PER AMM33-51-00, FOUND WORKING SATISFACTORY.SDR CALA2025112811552Battery · inoperativeDOOR 4L EMERGENCY POWER SUPPLY BATTERY FAILED TEST. BATTERY REPLACED IAW AMM 33-51-00. INSTALLATION TEST CARRIED OUT FO DOOR 4L EMERGENCY POWER SUPPLY BATTERY (M33406) AS PER AMM33-51-00, FOUND WORKING SATISFACTORY.SDR CALA2025112111383Unknown · odorON ACCOUNT OF A INDISTINGUISHABLE ODOR IN CABIN, INSPECTED DUCTS FOR EVIDENCE OF OIL IAW AMM 36-12-04-200-801. OPENED DUCT IN A/C BAY JUST BEFORE OZONE CONVERTER, NO EVIDENCE OF ANY CONTAMINATION. SHOULD READ OPENED BOTH LT AND RT SIDE DUCTS. PRIOR TO THE OSDR CALA2025112411403Unknown · odorSTRONG ELECTRICAL ODOR NOTICED IN THE AREA OF THE MOST AFT GALLEY COMPLEX. ODOR BEGINS PAST THE MED 4L, AFT; (AIRCRAFT HAD BEEN STATIC WITH NO SYSTEMS "ON" FOR APPX 8HRS). NEED TO INVESTIGATE ALL AREAS, INCLUDING ABOVE CEILINGS AND AFT BULK PIT AREA. NOTICED NSDR CALA2025112111388Filter · dirtyPERFORM CONDITIONAL INSPECTION FOR SMOKE/ODOR IN CABIN 05-51-58-800-801-C3. ACCOMPLISHED CONDITIONAL INSPECTION, INITIAL INSPECTION, UP TO STEP F. NO FINDINGS, NO DEFECTS NOTED. INSPECTED AND PERFORMED ALL TEST ON ALL CABIN, GALLEY, LAV, CREW REST LIGHTING. SDR CALA2025111111107Battery · inoperativeDOOR 4R EPAS BATTERY GREEN TEST LIGHT NOT ILLUMINATED/BLINKING. REMOVED DOOR 4R EPAS BATTERY PACK REF AMM 52-12-20-000-803-002. REPLACED DOOR 4R BATTERY PACK MODULE REF AMM 52-12-20-400-802-002. EPAS BATTERY OPS TEST GOOD, GREEN TEST LIGHT ILLUMINATED/BLINKINGSDR CALA2025110710982None · noneL5 DOOR SAFETY PINS INSTALLED ONE FOR INFLATION AND GIRT PER MM TASK 52-12-20-700-802-002. REMOVED SAFETY PINS FROM GIRT AND CYLINDER INFLATION POSITIONS RESTOWED IN STOWAGE COMPARTMENT. ACP'D INSPECTION VERIFIED PINS REMOVED AND STOWED.SDR CALA2025110510913Guard · unsecureEMERGENCY LIGHT SWITCH GUARD IS LOOSE SECURED EMERGENCY LIGHT SWITCH GUARD .SDR CALA2025110710994Fire Warning · false activationAFT CARGO FIRE INDICATED. REMOVED LOWER CARGO FIRE EXTINGUISHING BOTTLES 1A AND 1B AS PER AMM 26-23-01.SDR CALA2025102710561Unknown · vaporVAPER SMOKE ODOR IN 4R LAV,. SMOKE LAV LIGHT CAME ON FOR A FEW SECONDS. REF TASK 26-13-00-730-801. PERFORMED SMOKE DETECTOR TEST ALL PARAMETERS PASSED CSAP SHOWED NO FAULTS, NO EICAS MSGS. POSSIBLE VAPER IN LAV. OPS CHKD GOOD.SDR CALA2025102310443Battery Pack · no testEMERGENCY EXIT LIGHTS TURNED ON IN THE AIR. FLASHING INTERMITTANTLY. REPLACED FWD EMERGENCY BATTERY M33093 ABOVE DOOR L1. REPLACED AFT EMERGENCY BATTERY M33098 ABOVE DOOR R2 ALL EMERGENCY LIGHTS GROUND TEST PASSED.SDR CALA2025102010254Oven · smokeOVEN SMOKING OR SPARKING G9B GALLEY HALF CARRIER BOX 938R OVEN 606 SMOKING WHEN ON. OVEN 606 HAS STRONG SMELL OF BURNED FOOD. OVEN NEEDS DEEP CLEAN OR REPLACEMENT. DEFERRED OVEN 606 AS PER NEF 2520AV. M PROC C/W. REMOVED AND REPLACED 606 OVEN PER AMM 25-32-SDR CALA2025102010251Interphone · faultedINTERPHONE BETWEEN FLIGHT DECK AND CABIN INOPERATIVE PERFORMED OPS CHECK ON CABIN INTERPHONE SYSTEM IAW AMM REF. 23-42-00-710-801. COMMUNICATION BETWEEN FLIGHT DECK AND CABIN FUNCTIONS NORMALLY. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME. UPON THE SDR CALA2025101710231Control Panel · inoperativeOBSERVER ACP INOPERATIVE. CANT CHANGE SELECTED TRANSMIT SWITCH. ACP FROZEN UNABLE TO SELECT ANY MIC ON OBSERVERS AUDIO CONTROL PANEL. REMOVED AND REPLACED OBSERVER ACP PER AMM 23-51-01. OPS CHECK GOOD. NO DEFECTS NOTED. ACFT OKAY TO CONTINUE.SDR CALA2025101610188Controller · faultedBLEED FAMV R EICAS STATUS RIGHT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN O R CLOSED, OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. CMC MSG 3610325, AIR SUPPLY & CABIN PRES SURE CONTROLLER (R) PRESENT LEG FAULTS AND EXISTING FAULTS. SDR CALA2025101410045Slide · no discrepancySAFETY PIN INSTALLED ON THE INFLATION BOTTLE FOR DOOR 3L - OVERWING ESCAPE SYS REF AMM TASK 25-65-00-040-801. REMOVED AND STOWED SAFTEY PINS FROM LH INFLATION BOTTLE REF AMM 25-65-00 ACCOMPLISHED RII INSPECTION FOR REMOVAL OF 3L OVERWING ESCAPE BOTTLE SAFETY PSDR CALA2025100809781Pin · installedREF ETASK CARD 23-5212-1-2001. INSTALLED 2 EA. L2 PED SLIDE SAFETY PINS. RMV'D & STOWED 2 EA. SAFTEY PINS FOR PED L2 REF ETASK CARD 23-5212-1-2001. INSPECTED VERIFIED SLIDE PIN STOWED AND OPCH OK.SDR KCSA202510071177Battery · inoperativeFOUND EMERGENCY EXIT SIGN FOR L1 DOOR INOPSDR KCSA202510071176Light · inoperativeFOUND EMERGENCY LIGHT INOP ON PANEL ABOVE THE L1 DOOR.SDR CALA2025100209558Slide · no discrepancyOFF-WING ESCAPE SLIDE PACK - INSTALLATION OFF-WING ESCAPE SLIDE PACK INSTALLATION, LT OVERWING SLIDE ETASK CARD BLOCK 8 TO BLOCK 12 ARE RII ITEMS. INSPECTION BUYBACK REQUIRED. UPGRADED TO RII. ALL STEPS ACP'D. INSPECTION WITNESSED INSTALLATION ON LH OVERWING SDR CALA2025100109514Battery Pack · dischargedR5 (M33408) EMERGENCY POWER SUPPLY BATTERY FOUND LOW CAPACITY. REPLACED R5 (M33408) EMERGENCY POWER SUPPLY BATTERY PACK AND INSTALLATION TEST C/O RESULT FOUND NORMA L REF AMM 33-51-06-960-802 REV104.SDR CALA2025100109502Battery Pack · dischargedOFCR BACKUP POWER SUPPLY BATTERY, FOUND TO HAVE LOW CAPACITY. REPLACED OFCR BACKUP POWER SUPPLY BATTERY PACK AND TESTED NORMAL IAW AMM 33-29-10-960-810, REV 104.SDR CALA2025100109500Battery Pack · dischargedL2 FWD EMERGENCY POWER SUPPLY BATTERY FOUND TO HAVE LOW CAPACITY. REPLACED THE BATTERY, TESTED NORMAL IAW AMM 33-51-06-960-802, REV 104.SDR CALA2025093009444Battery Pack · dischargedR3 MID (M33305) EMERGENCY POWER SUPPLY BATTERY FOUND LOW CAPACITY. REPLACED R3 MID (M33305) EMERGENCY POWER SUPPLY BATTERY PACK AND TEST,C/O RESULT FOUND NORMAL REF AMM 33-51-06-960-802 REV104.SDR CALA2025093009443Battery Pack · dischargedL2 AFT (M33099) EMERGENCY POWER SUPPLY BATTERY FOUND LOW CAPACITY. REPLACED L2 AFT (M33099) EMERGENCY POWE R SUPPLY BATTERY PACK AND TEST C/O RESULT FOUND NORMAL REF AMM 3 3-51-06-960-802 REV104.SDR CALA2025093009442Battery Pack · dischargedL4 (M33405) EMERGENCY POWER SUPPLY BATTERY FOUND LOW CAPACITY. REPLACED L4 (M33405) EMERGENCY POWER SUPPLY BATTERY AND TEST C/O RESULT FOUND NORMAL REF AMM 33-51-06-960-802 REV104.SDR CALA2025093009441Battery Pack · dischargedR1 (M33094) EMERGENCY POWER SUPPLY BATTERY FOUND LOW CAPACITY, REPLACED R1 (M33094) EMERGENCY POWER SUPPLY BATTERY AND INSTALLATION TEST,C/O FOUND NORMAL REF AMM 33-51-06-960-802 REV104.SDR CALA2025093009440Battery Pack · dischargedOFCR (M33145) BACKUP POWER SUPPLY BATTERY FOUND LOW CAPACITY. REPLACED OFCR (M33145) BACKUP POWER SUPPLY BATTERY PACK AND TEST C/O RESULT FOUND NORMAL REF AMM 33- 29-10-960-810 REV104.SDR CALA2025093009434Battery Pack · dischargedOFAR (M33142) BACKUP POWER SUPPLY BATTERY FOUND LOW CAPACITY. REPLACED OFAR (M33142) BACKUP POWER SUPPLY BATTERY PACK AND INSTALLATION TEST,CO RESULT FOUND NORMA L REF AMM 33-29-12-960-809 REV104.SDR CALA2025092909350Light · brokenSEAT 39D, 52D EMERGENCY LIGHT BROKEN. REPLACE LIGHT MODULE AND WORK NORMAL.PARTS USED: 99-3350-3-0008, QTY :2 CHK OKSDR CALA2025092309162Bracket · damagedFWD CARGO DOOR SENSOR (S52001) BRACKET DAMAGED. INSTALLED BRACKET FOR PROXIMITY SWITCH WITHIN LIMITS IAW AMM 52-34-20-201 PERFORMED INDICATION PROXIMITY SENSOR TEST 52-71-02-730-801 OK FOR SERVICE. INSTALLED STRIKER PLATE TARGET FROM AIRCRAFT 2139 PER IPC 5SDR CALA2025092309151Slide · no discrepancyINSTALLED SAFETY PIN ON DOOR 3R OFFWING ESCAPE SLIDE INFLATION CYLINDER REGULATOR AND DEACTIVATED LATCH ACTUATOR FOR ESCAPE SLIDE COMPARTMENT DOOR REF AMM 25-65-00-040-802 REMOVED SAFETY PIN AND STOWED. REACTIVATED LATCH ACTUATOR FOR ESCAPE SLIDE COMPARTMENT DSDR CALA2025092209078Battery Pack · inoperativeEMERGENCY POWER ASSIST SYSTEM (EPAS) BATTERY PACK - REMOVAL (PED 3) PREPARE FOR THE REMOVAL - REMOVED PANEL 198NAR FOR LATCH ACTUATOR DEACTIVATION REF AMM 25-65-00-040-802 REINSTALLED PANEL 198NARSDR CALA2025091809023Light · inoperativeFOUND 43D, 48G EMERGENCY LIGHT ARE INOP. REPLACED NEW EMERGENCY LIGHT ASSEMBLY IN SEAT, CHK FUNCTION NORMALSDR CALA2025091208830Fuse · failedCHECK CABIN EMERGENCY LIGHT FOUND A GROUP OF EMEGENCY LIGHTS INOP FOR POWER PACK M33409. IAW AMM 33-51-06-960-802 TO REPLACE BATTERY. BUT PERFORMED OPS TEST FOUND 14EA FLOOR PROXIMITY LIGHTS INOPERATIVE FROM SEAT 52 TO SEAT 59. IAW AMM 33-51-06-960-801 & 33-51SDR CALA2025091108776Light · brokenGALLEY M2 RIGHT SIDE EMER FLOOR PROXIMITY LIGHT HOUSING BROKEN AND LENS MISSING. R & R GALLEY M-2 RIGHT SIDE EMERGENCY PROXIMITY LIGHT ASSY AND TEST CHK OK.SDR CALA2025091008722Warning Message · false activationCABIN CONTROL PANELS 1L 2L 3L SHOW SMOKE DET MESSAGE NO SMOKE PRESENT IAW FIM 26-14 TASK 811. RESET CSCP MESSAGE CLEARED. NO EVIDENCE OF SMOKE OR ODOR THROUGHOUT CABIN, NO SMOKE RELATED MESSAGES FOUND IN HISTORY.SDR CALA2025090408480Probe · faultedDURING CLIMBOUT HAD INDICATION OF POSS FUEL LEAK SHOWED 8K LOSS REQUEST TO MEL. INSPECTED AIRCRAFT UPON ARRIVAL. NO FUEL LEAKS NOTED. RIGHT FUEL QTY INDICATION INOP PROBE #24 AT FAULT PLACARD INSTALLED. REPLACED PROBE #24 REF AMM 28-41-02-400-801 CHECKED SAFESDR CALA2025090208376Light · inoperativeEMERGENCY LIGHTS, OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE, SEAT 55D & 56D AISLE MOUNT EMERGENCY LIGHT INOP. R&R SEAT 55D 56D AISLE MOUNT EMERGENCY LIGHT ASSY AND CHK OK.SDR CALA2025082708167Light · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - DURING THIS TASK, FOUND DOOR4 LEFT SIDE EMERGENCY LIGHT INOP. RPLED PER AMM 33-51-04/401, AND FUNCTION CHK NML. RPLED PER AMM 33-51-04/401, AND FUNCTION CHK NML.SDR CALA2025082508093Light · looseEMERGENCY EXIT LIGHTS LOOSE AT 47D RESECURED EMERGENCY LIGHT AT SEAT 47D REF AMM 33-51-01.SDR CALA2025082007965Bulb · no testWING ILLUMINATION LIGHTS - OPERATIONAL TEST PROCEDURE - LEFT LANDING LIGHT BULB DOES NOT PROVIDE ILLUMINATION UPON REMOVAL OF BULB NOTICED TERMINALS TO BE SINGED AND EMITTING AN ODOR. INSPECTED LEFT WING LANDING LIGHT (L33115) WIRES. FOUND ON WIRE W5164-0056-1
Back to Boeing 777-300ER