Boeing 777-300ER
Service difficulty reports · 456
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023031300729Battery Pack · no testEMERGENCY LIGHT POWER SUPPLY BATTERY PACK AT DOOR 4R FAILED OPER ATIONAL CHECK. REF SIAEC N/R ELE0069 POWER SUPPLY BATTERY PACK AT DOOR 4R (M33404) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0069SDR CALA2023031300728Battery Pack · no testEMERGENCY LIGHT BATTERY PAK AT DOOR 3L FAILED OPERATIONAL CHECK. REF SIAEC N/R ELE0067 POWER SUPPLY BATTERY PACK AT DOOR 3L (M33303) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0068SDR CALA2023030900651Bulkhead · noneDURING HMV MAINTENANCE CHECK AT SIAEC DENT WITH GOUGE WAS FOUND AT STA 2150 AFT PRESSURE BULKHEAD AFT WEB ADJACENT TO S-6R. TO C ARRY OUT REPAIR PER RI N0:UARI-53-0001 PLACING ON DIP PER PART 1 OF ECRA TO ACCOMPLISH INSPECTION REQUI S-6R AS PER PART 2 OF LATESSDR CALA2023030100589Battery · failedB777-33-3-7019 DR R2 EMER LIGHT BATTERY M33098 CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1462757 AND ORIGINATOR V898181. DR R2 EMER LIGHT BATTERY M33098 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK SDR CALA2023030100587Battery · failedB777-33-3-7019 DR L2 EMER BATTERY M33096 CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1462768 AND ORIGINATOR V898181. DR L2 EMER LIGHT BATTERY M33096 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK ACCOMPSDR CALA2023030100586Battery · failedB777-33-3-7019 AFT CREW REST L/H EMER LIGHT BATTERY M33143 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462794 AND ORIGINATOR V898181. AFT CREW REST EMER LIGHT BATTERY M33143 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPSDR CALA2023030100584Battery · failedB777-33-3-7019 DR L4 EMER LIGHT BATTERY M33405 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462800 AND ORIGINATOR V934240. DR L4 EMER LIGHT BATTERY M33405 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK ACCOMPLSDR CALA2023030100583Battery · failedB777-33-3-7019 DR R3 EMER LIGHT BATTERY M33305 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462812 AND ORIGINATOR V898181. DR R3 EMER LIGHT BATTERY M33305 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V89695SDR CALA2023030100582Charger · failedB777-33-3-7019 DR R4 EMER LT CHARGER M33401 TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1462818 AND ORIGINATOR V898181 DR R4 EMER LT BATTERY CHARGER M33401 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958 SDR CALA2023030100581Battery · failedB777-33-3-7019 DR R4 EMER LIGHT BATTERY M33401 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462826 AND ORIGINATOR V898181. DR R4 EMER LIGHT BATTERY M33401 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED WORK ACCOMPLISDR CALA2023013000247Battery · weakSUPPORT TASK DR L4 M33405 POWER SUPPLY FOUND BATTERY WEAK. DR L4 M33405 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2023013000246Battery · weakDR L5 M33407 POWER SUPPLY FOUND BATTERY WEAK. DR L5 M33407 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023012700219Battery · weakDR R2 M33097 POWER SUPPLY FOUND BATTARY WEAK. DR D2 M33097 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023010200007Charger · failedDR 3 RH M33304 EMER LT BATTERY PACK CAPACITY TEST FAIL. EMER LT BATTERY PACK AND CHARGER REPLACED AND TE STED NORMAL AS PER AMM 33-51-06.SDR CALA2023010200006Battery · failedDR 3 RH M33306 EMER LT BATTERY PACK CAPACITY TEST FAIL. EMER LT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2022123003517Fitting · not reportedPDA 1 FITTING FRO EXT PC AIR DOOR FOR THE HOLD OPEN ROD HE 149W2119-2: DEPARTED THE AIRCRAFT ACCOMPLISHED INTERIM REPAIR IAW ECRA 5394-01002.SDR CALA2022122103451Battery Pack · no testEMER LIGHT BATTERY M33143 CAPACITY CHECK FAIL. . EMERG LT BATTERY M33143 REPLACED & TEST CARRIED OUT RESULT NORMAL.SDR CALA2022122103450Battery Pack · no testDR R4 EMER LIGHT BATTERY M33404 CAPACITY CHECK FAIL. DR R4 EMER LIGHT BATTERY M33404 BATTERY PACK REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2022122103449Battery Pack · no testDR L5 EMER LIGHT BATTERY M33407 CAPACITY CHECK FAIL WORK. EMERG LT BATTERY M33407 REPLACED & TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2022122103448Battery Pack · no testSUPPORT TASK DR R5 EMER LT BATTERY M33409 CAPACITY CHECK FAIL. DR R5 EMER LT BATTERY M33409 BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2022122103447Battery Pack · no testDR R3 EMER LIGHT BATTERY M33306 CAPACITY CHECK FAIL.. EMERG LT BATTERY M33306 REPLACED & TEST RESULT NORMAL.SDR CALA2022122103446Battery Pack · no testDR L4 EMER LIGHT BATTERY M33400 CAPACITY CHECK FAIL. DR L4 EMER LT BATT PACK REPLACED AND OP TEST NORMAL I.A.W AMM 33-51-06.SDR CALA2022122103445Battery Pack · no testDR L4 EMER LIGHT BATTERY M33405 CAPACITY CHECK FAIL . . DR L4 EMER LT BATT PACK REPLACED AND OP TEST NORMAL I.A.W. AMM 33-51-06.SDR CALA2022122103444Battery Pack · no testSUPPORT TASK DR L3 EMER LIGHT BATTERY M33302 CAPACITY CHECK FAIL. DR L3 EMER LIGHT BATTERY M33302 BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 .SDR CALA2022122103443Battery Pack · no testSUPPORT TASK DR L1 EMER LT BATTERY M33093 CAPACITY CHECK FAIL WORK TRANSFER REF NON ROUTINE WO.1334711 AND ORIGINATOR BY V898181. DR L1 EMER LT BATTERY M33093 BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2022122103442Battery Pack · no testSUPPORT TASK DR R4 EMER LIGHT BATTERY M33401 CAPACITY CHECK FAIL WORK TRANSFER REF NON ROUTINE WO.1334689 AND ORIGINATOR BY V898181. DR R4 EMER LIGHT BATTERY M33401 BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V898SDR CALA2022121903433Skin · damagedFUSELAGE SKIN DAMAGE AT STA 2108 AT STR 24L . REF LOG PAGE 6945293 FOR INSPECTION OF DAMGE AND WORK ACCOMPLISHED. REPAIR ON OR BEFOR 500 CALANDER DAYS OF PART 3 OF EC/RA 5330-06860 REFE ECRA 5330-06860, REPEAT INSPECTION EVERY 100 FLIGHT CYCLES TOMC-APPROVAL FSDR CALA2022121403376Charger · inoperativeB777-33-3-7019 DR R3 EMER LIGHT CHARGER M33306 TEST FAIL TRANSFER REF NON ROUTINE WO.1262159 AND ORIGINATOR BY V896958 DR R3 EMER LIGHT BATTERY CHARGER M33306 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958SDR CALA2022112503211None · noneCREW HEARD A LOUD BANG ON CLIMBOUT THROUGH 8000 FT NOISE NOTICED FWD OF DOOR 1LEFT . DISCOVERED BIRD STRIKE BELOW AND AFT OF L3 COCKPIT WINDOW. PERFORMED BIRD STRIKE INSP PER AMM 05-15-18-210-801. NO DAMAGE OR EVIDENCE OF ADDITIONAL BIRD STRIKES FOUND ON AIRCRSDR CALA2023112203446Skin · dentedDENT FOUND IN FUSELAGE FWD DOOR 2L AFTER FURTHER INSPECTION FOUND AREA CONTAINS MULTIPLE DENTS. TOTAL DENTED AREA MEASURES 15" IN LENGTH 4" IN WIDTH AND .072" IN DEPTH. DENTS ARE LOCATED BETWEEN STA 655 AND STA 676 AND BETWEEN STRINGERS S24L AND S25L. FLT CYCLSDR CALA2022071501768Strainer · broken#2 ENGINE MAIN FUEL PUMP INTERSTAGE STRAINER FOUND BROKEN AND DEFORMED . REFERENCE TASK 73-11-04-200-801-H00. FOUND ABNORMAL DISCREPANCY (BROKEN MAIN FUEL PUMP INTERSTAGE LP#9057853 LOCATION IS # 1 ENGINE DISCREPANCY. FILTER) AT#1 ENGINE. RECOMMEND SDR TO BSDR CALA2022062201556Mount Bracket · crackedEMERGENCY FLASHLIGHTS OPERATIONAL CHECK {B777-25-3-7022} - FIRST OFFICER SIDE, EMERGENCY FLASH LIGHT MOUNT BRACKET BROKEN AND SECRUITY PLACARD BAND TORN. ORDERED FLASHLIGHT WITH HOLDER ME 78-2500-3-0454 REPLACED FIRST OFFICER BROKEN EMERGENCY FLASHLIGHT MOUNT SDR CALA2022061701523Transceiver · failedBOTH WEATHER RADARS FAILED IN FLIGHT REPLACED WXR ANT DRIVE UNIT & R-WXR TRANSCEIVER PER FIM 34-43 TA SK 822, GND TEST PASS AND NO FAULT MSG FOUND.SDR CALA2022060601447Smoke Detector · fault messageCSCP/CACP "SMOKE DETECTED" INDICATION FAULT MESSAGE SH OWS 5L RESET PANEL PER AMM TASK 23-39-16. OPS CHECK NORMALSDR CALA2022052301327Circuit Breaker · inoperativeCSCP/CACP & QUOT;SMOKE DETECTED & QUOT; INDICATION FAULT MESSAGE SH OWS G5 GALLEY HALF CARRIER BOX 503F SMOKE DETECTED MSG ON FLIGHT ATTENDANT DISPLAY PANEL CSCP CBS RESET CHECKED ALL NORMALSDR CALA2022051601266Solenoid · damagedCREW REPORT ON ARRIVAL PRIOR TO DEPARTURE FROM SFO AIRCRAFT LEFT ENGINE CAME INTO CONTACT WITH STAND DURING REFUELING. PILOT SHARED PHOTO AND SAID HE RECIEVED VERBAL ASSURANCE. SUBSEQUENT L ENG ANTI ICE STATUS MESSAGE. 332W1360-123 QTY 1, TUBE 332W1360-72 QTY SDR CALA2022051301218Mask · unserviceableSEAT 33DEFG & 46DEF O2 MASKS DID NOT DEPLOY DURING INADVERTENTLY DEPLOYMENT OF ALL MASKS. NEED TO CREATE A SDR. SEE LP''S 8563975, 8564803, AND 8564813. CORRECTION ACTION: REPACKED MASKS AND ACCOMPLISH AN DEPLOYMENT OPERATIONAL CHECK. DEPLOYED NORMALLY AND SOLSDR CALA2022042901107Smoke Detector · warning messageSMOKE DETECTED MSG DISPLAYED LEFT HAND CACP DR 5L RESET ACFT POWER MSG CLEARED.SDR CALA2022042701078Skin · dentedFOUND DENT WITH GOUGE BETWEEN STA 825 AND 825+21 AT STRINGER 27-L. GOUGE NEEDS TO BE BLENDED PER SRM. REMOVED DAMAGE PER SRM 53-30-01-1A-1 AND SRM 51-10-02.NEED QC TO PERFORMED THICKNESS MEASUREMENT REF. NDT 51-00-10 PROCEDURE 1 DENT MEASURES 1.4"X1.8"X0.064".SDR 2022F00074Fan · blockedSMOKE IN CABIN AND ELECTRICAL SMELLSDR CALA2021122702446Smoke Detector · activatedCREW REPORTED TO HMC: LAV 2R SMOKE ALARM ACTIVATED DURING FLIGHT; FLIGHT ATTENDANT FOUND CUSTOMER FROM SEAT 8L ATTEMPTING TO EXTINGUISH SMOKING CELL PHONE IN THE LAV TOILET; CUSTOMER ATTEMPTED TO EXTINGUISH SMOKE CONDITION BY PLACING CELL PHONE IN THE LAV SINKSDR CALA2021121702393None · noneON TAKE OFF ROLL ON RWY 9R ORD A/C STATE ON TAXI WAY. ELEC TEST. TEST OK. VERIFIED RUNWAY 9R WAS SELECTABLE PER TOMC REQUEST VERIFIED THE FOLLOWING INFORMATION: CORRECT NAV FOR EGPWC DB SOFTWEAR UPDATE TO 624. EGPWC DATA BASE U772112.001 INSTALLED. GPS COORDISDR 2021F00311None · noneBATTERY PACK AT DOOR 1R DOES NOT OPERATE CORRECTLY. REPLACED BATTERY PACK IAW AMM 33-51-06SDR 2021F00373None · noneBATTERY PACK AT DOOR 1R DOES NOT OPERATE CORRECTLY. BATTERY PACK AT DOOR 1R REPLACED IAW AMM 33-51-06. SEE AML MIC 9613325SDR CALA2021110802058Light · inoperativeSUPPORT TASK - SEAT 12D FLOOR PROXIMITY EMERG LIGHT FOUND INOP TRANSFER REF. NON - ROUTINE LP9130379 AND ORIGINATED BY EMP V897810 12D FLOOR PROXIMITY EMER LT ASSY REPLACED AND TEST NORMAL REF AMM33-51-05 WORK ACCOMPLISHED BY MECHANIC V897794 INSPECTED BY V907SDR CALA2021110102012Flashlight · inoperativeAFT FA SEAT EMERGENCY FLASHLIGHT AT DOOR L1 INOP REMOVED AND REPLACED DR-1 AFT F/A SEAT EMERGENCY FLASHLIGHT BATTERY PACK PER AMM 25-64-01. OPS CHECK NORMAL.SDR CALA2021102501971Indication Sys · failedDECLARED EMERGENCY CENT HYD QUANT WENT TO ZERO VERIFIED CENTER SYSTEM HYDRAULIC QUANTITY RESERVOIR LEVEL PLACARDS APPLIED. NORMAL. HYDRAULIC SYSTEM PRESSURES OK. REQUEST MEL. . REVERSED MEL. ON RESERVE ISOLATION VLV AND NOSE GEAR, GEAR HANDLE, ALSO NO DEFSDR CALA2021082301424Skin · puncturedFX - STA2174 - 2195.75 STR30R - 31R FOUND PUNCH TRANSFER REF. REPAIR ACCOMPLISHED PER SRM 53-00-01-2R-4 REPAIR 4 FIG 202 AND CRITICAL ROW FASTENERS ZERO TIMED. REQUIRED INSPECTION PER SRM 53-10-01-2R-4 REPAIR PARAGRAPH 6 FOR ZONE B REF TABLE 204 CATEGORY B RSDR CALA2021082001386Slat · damagedPDA 1 6"BY 9" PIECE SECTION MISSING FROM #5 SLAT. FOUND ON ARRIVAL. FOLLOWING GMM 02-30-95SDR CALA2021062300942Smoke Detector · false activationOVERHEAD PILOT REST AREA SMOKE DETECTOR ON AND CHIME WHEN EXT PWR PULLD RESET PILOT CREW REST SMOKE DERECTOR FROM CACP PERFORM SYS TEST OPS CK. NORMAL.
Back to Boeing 777-300ER