SDR CALA2023071902278Oven · inoperativeSMOKE FROM OVEN 410. OVEN TURNED OFF CB PULLE D. OVEN SMOKE DUE TO SPILLED FOOD . PLACED ON MEL. COMP. WITH MEL OVEN INOPED. NOC DESK: 777 NAME: DOUG DATE: 17-JUL-23- MID GALLEY OVEN 410 - NEF 2520AV PLEASE DO NOT USE TILL OVEN IS REPLACED. RTBL FOR SMOLE ISDR CALA2023071202226Battery · failedSUPPORT TASK-DR L1 M33093 EMER LIGHT BATTERY CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1933493. DR L1 M33093 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023071202225Charger · failedB777-33-3-7019 R4 DOOR M33401 EMER BATT CHARGER FAIL. TRANSFER REFER NON-ROUTINE WO.1924221 DR R4 M33401 EMER LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023071202224Battery · failedB777-33-3-7019 DR R2 M33098 EMER LIGHT BATTERY TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1926108. DR R2 M33098 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023071202223Battery · failedB777-33-3-7019 DR L4 M33406 EMER LIGHT BATTERY TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1926110. DR L4 M33406 EMER LIGHT REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2023070702182Skin · damagedRAMP REPORTED DAMAGE (GAUGE) ABOUT 5" FWD FOR THE FWD CARGO AT THE LAP SEEM. CORRECTION, DAMAGE IS 5 FEET FORWORD OF THE FORWARD CARGO DOOR. DAMAGE IS 66.5" FWD OF FWD CARGO DOOR CUTOUT BETWEEN STATIONS REMOVED FASTENERS ON SKIN LAP AND STRINGER JUST BELOW. CUSDR CALA2023060701769Battery · unknownOFAR BACKUP LIGHT POWER SUPPLY TEST FOUND THE BATTERY PACK(M3314 3) CAN NOT BE CHARGED REF TO HAECO NON-ROUTINE NO.9459962, ORIGI NATED BY EMP V907748, SPEC NO.B777-33-3-7005. PERFORMED BY EMP V907748 AND IDY BY EMP V903172 - REPLACED THE B ATTERY PACK M33143 SDR CALA2023053101728Frame · crackedLH PYLON INBD NUMBER 3 FRAME (FROM FWD) LOWER AREA CRACKED. REPAIRED IAW ECRA 5452-01606 REF UARI-54-0009 REV 1. ECRA AUTHORIZES REPAIR OF DAMAGED FRAME PER SB 777-54-0044 ORIGIONAL REVISION WORK PACKAGE 2 AND AUTHORIZATION TO OMIT INSPECTION OF COUNTERSINKS.SDR CALA2023053101715Battery · failedB777-33-3-7019 OFAR R/H M33142 EMER LIGHT BATTERY CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1821498 AND ORIGINATOR V898181. OFAR R/H M33142 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTEDSDR CALA2023053101714Battery · failedB777-33-3-7019 DR R5 M33408 EMER LIGHT BATTERY TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1821513 AND ORIGINATOR V898181. DR R5 M33408 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958SDR CALA2023053101713Battery · failedB777-33-3-7019 DR R5 M33409 EMER LIGHT BATTERY TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1821512 AND ORIGINATOR V898181. DR R5 M33409 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958SDR CALA2023053101712Battery · failedB777-33-3-7019 DR L4 M33405 EMER LIGHT BATTERY TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1821510 AND ORIGINATOR V898181. DR L4 M33405 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958SDR CALA2023053101711Battery · failedB777-33-3-7019 DR R1 EMER LIGHT BATTERY M33094 TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1821526 AND ORIGINATOR V898181. DR R1 EMER LIGHT BATTERY M33094 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958SDR CALA2023053101710Battery · failedB777-33-3-7019 DR L1 M33093 EMER LIGHT BATTERY TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1821528 AND ORIGINATOR V898181. DR L1 M33093 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958SDR CALA2023053101701Battery · failedB777-33-3-7019 - DR R3 M33306 EMER LIGHT BATTERY CAPACITY CHECK FAIL - TRANSFER REFER NON-ROUTINE WO.1821503 AND ORIGINATED BY EMP V898181 DR R3 M33306 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 - WORK ACCOMPLISHED BY MECH V898181 AND INSPECSDR CALA2023053101700Battery · failedB777-33-3-7019 - DR L3 M33302 EMER LIGHT BATTERY TEST FAIL TRANSFER REFER NON-ROUTINE WO.1821511 AND ORIGINATED BY EMP V898181 DR L3 M33302 EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V89SDR CALA2023052401615Battery · failedDR 4L EMERGENCY POWER SUPPLY BATTERY (M33400) FAIL TEST. P/N: D7 17-01-100, S/N: 428800 DR 4L EMERGENCY POWER SUPPLY (M33400) REPLACED AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06-906-802, FOUND WORKING SATI SFACTORY. P/N ON: D717-01-100, S/N ON: 2778SDR CALA2023052401614Battery · failedDR 4L EMERGENCY POWER SUPPLY BATTERY (M33405) FAIL TEST. P/N: D7 17-01-100, S/N: 429216 DR 4L EMERGENCY POWER SUPPLY (M33405) REPLACED AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06-906-802, FOUND WORKING SATI SFACTORY. P/N ON: D717-01-100, S/N ON: 2731SDR CALA2023052401613Battery · failedDR 4R EMERGENCY POWER SUPPLY BATTERY (M33401) FAIL TEST. P/N: D7 17-01-100, S/N: 429711 DR 4R EMERGENCY POWER SUPPLY BATTERY (M33401) REPLACED AND INSTA LLATION TEST CARRIED OUT AS PER AMM 33-51-06-906-802, FOUND WORK ING SATISFACTORY. P/N ON: D717-01-100, S/NSDR CALA2023052401612Battery · failedDR 5R EMERGENCY POWER SUPPLY BATTERY (M33408) FAIL TEST. P/N: D7 17-01-100, S/N: 432745 DR 5R EMERGENCY POWER SUPPLY BATTERY (M33408) REPLACED AND INSTA LLATION TEST CARRIED OUT AS PER AMM 33-51-06-906-802, FOUND WORK ING SATISFACTORY. P/N ON: D717-01-100, S/NSDR CALA2023052401616Battery · failedOFAR EMERGENCY POWER SUPPLY BATTERY (M33143)(MIRROR) FAIL TEST. P/N: D717-01-100, S/N: 432102 OFAR EMERGENCY POWER SUPPLY (M33143) REPLACED AND INSTALLATION T EST CARRIED OUT AS PER AMM 33-51-06-906-802, FOUND SATISFACTORY. P/N ON: D717-01-100, S/N ON: 315620 SDR 2023FA0000271Stringer · crackedRH WING RIB 12, 6EA STRINGERS (STRINGER 26, 28, 29, 30, 31, 32) CRACKED. REFER ATTACHED AMAC OCCURRENCE REPORT NO. 760 REV. A AND BOEING SERVICE REQUEST NO. 4-5828495000.SDR 2023FA0000255Battery · dischargedEMERGENCY LIGHTS INOP AT 2L DOOR AND MID GALLEYSDR CALA2023050901444Light · inoperativeDURING PERFORM EMERGENCY LIGHT OPERATIONAL TEST FOUND PAX SEAT 53G FLOOR PROXIMITY LIGHT INOP REF HAECO NON-ROUTINE NO.9456320 - ORIGINATED BY EMP V903179 SPEC NO.B777-33-3-7031. PERFORMED BY EMP V903179, THE PAX SEAT 53G FLOOR PROXIMITY LIGHT ASSY REPLACED ANSDR CALA2023050901424Battery Pack · no testB777-33-3-7019:NO LIGHT AT OFAR ENTRANCE AND LEFT SIDE BUNK EMER GENCY LIGHT DURING OPERATION TEST.FOUND EMERGENCY LIGHT BATTERY (M33143) INOPERATIVE.PN OFF:D717-01-100, SN OFF:433673. EMERGENCY LIGHT BATTERY PACK REPLACED AS PER AMM 33-51-00. INSTA LLATION TESDR CALA2023050901433Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 4 RIGHT (M33401) EMERGENCY LIGHT BAT TERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 155992 REPLACED DOOR 4 RIGHT EMERGENCY LIGHT BATTERY PACK M33401 AND IN WORK ACCOMPLISHED BY V943538 STALLATION TEST PASSED ASSDR CALA2023050901432Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 4 LEFT (CENTER M33406) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 434082 REPLACED DOOR 4 LEFT EMERGENCY LIGHT BATTERY PACK M33406 AND WORK ACCOMPLISHED BY V943538 INSTALLATION TEST PASSEDSDR CALA2023050901431Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 4 LEFT (AFT M33405) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 434096 REPLACED DOOR 4 LEFT EMERGENCY LIGHT BATTERY PACK M33405 AND INS WORK ACCOMPLISHED BY V943538 TALLATION TEST PASSED ASDR CALA2023050801403Battery Pack · no testB777-33-3-7019 B2 INT: DR 5 RIGHT (AFT M33409) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 433005 REPLACED DOOR 5 RIGHT EMERGENCY LIGHT BATTERY PACK M33409 AND INSTALLATION TEST PASSED AS PER AMM 33-51-06. P/N ON: D7SDR CALA2023050801402Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 5 RIGHT (FWD M33408) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 432865 REPLACED DOOR 5 RIGHT EMERGENCY LIGHT BATTERY PACK M33408 AND INSTALLATION TEST PASSED AS PER AMM 33-51-06. P/N ON: SDR CALA2023050801401Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 2 RIGHT FWD (M33097) EMERGENCY LIGHT BTTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 176485 REPLACED DOOR 2 RIGHT EMERGENCY LIGHT BATTERY PACK M33097 AND INSTALLATION TEST PASSED AS PER AMM 33-51-06. P/N ON: DSDR CALA2023050501362Oxygen Bottle · unserviceableDURING LAVATORY CDS OXYGEN SYSTEM INSPECTION FOUND LAV ''A'' CDS O XYGEN CYLINDER DISCHARGE INDICATOR DAMAGED. TO REPLACE CDS OXYGEN CYLINDER TEST AS PER AMM TASK 35-21-00-710-801. TEST PASSED. P/N ON:4441806-022 S/N ON:41806-022-05983 FOUND THE LANYARD ASSY DSDR CALA2023042601260Battery Pack · no testOFAR RH EMERGENCY LIGHT BATTERY PACK (M33142) FAIL TEST. PN:D717 -01-100 AND SN:427403 OFAR RH EMERGENCY LIGHT BATTERY PACK (M33142) REPLACED AND OPERA TIONAL TEST CARRIED OUT. FOUND SATISFACTORY. (P/N ON:D717-01-100 AND S/N ON:297960)SDR CALA2023042601252Support Beam · damagedLH WING #3 FLAP SUPPORT TENSION BEAM DAMAGE TO THE LH WING #3 FLAP SUPPORT TENSION BEAM ASSY., P/N 113W1360- OF EC/RA 2751-01871 ON OR BEFORE 13 APRIL 2025 OR BEFORE REACHIN 601 S/N 9000, CENTER BEAM, P/N 113W1361-9 PER THE LATEST REV. G 5000 TOTAL FLIGHT CYCLSDR CALA2023042601251Skin · dentedAFT DOOR 5L HAS EXTERIOR SKIN DENT REWORK AT AFT LOWER CORNER. REWORKED REMOVED SKIN MEASURES ABOUT 1.5 IN L X.5 IN D WITH SLIGHT BENT INWARD TO SKIN. DOOR 5L LOWER AFT CORNER DOOR SEAL RETAINER NOT DAMAGED REF SRM REPAIR 8 52-10-01-2R-8. DOOR 5L PASSENGER ENSDR CALA2023042101200Battery · inoperativeDOOR 3L EPAS BATTERY FAIL TEST.(P/N:BPAS10-5 AND S/N:3637) TO RE PLACE BATTERY. EPAS BATTERY ROBBED FROM AIRCRAFT REGISTRATION N2143U AND INSTAL PART NUMBER INSTALLED:BPAS10-5 LED AS SERVICEABLE AT DOOR 3L. INSTALLATION TEST CARRIED OUT AS SERIAL NUMBER INSTALSDR CALA2023041901176Battery · failedSUPPORT TASK - DR R4 EMER LIGHT BATTERY M33401 TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1725504 AND ORIGINATOR V898181. DR R4 EMER LIGHT BATTERY M33401 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958 ISDR CALA2023041901175Battery · failedB777-33-3-7005 OFAR BACKUP EMERGENCY LIGHT BATTERY M33143 CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1658082 AND ORIGINATOR V897758. OFAR EMER LIGHT BATTERY M33143 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSDR CALA2023041901174Battery · dischargedSUPPORT TASK-DR L2 EMER LIGHT BATTERY M33099 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1668353 AND ORIGINATOR V898181. DR L2 EMER LIGHT BATTERY M33099 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958 SDR CALA2023041701146Battery · unknownFOUND DOOR 5 OFAR EMERGENCY LIGHT BATTERY PACK (M33143) LOW CAPA CITY (LESS THAN 15 MINUTES) REF TO HAECO NON-ROUTINE NO.9451994, ORIGINATED BY EMP V905400, SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905393 AND IDT BY EMP V907748 - REPLACED THE B ATTERY PACK M3SDR CALA2023041701145Battery · unknownFOUND DOOR R3 EMERGENCY LIGHT BATTERY PACK (M33306) LOW CAPACITY (LESS THAN 15 MINUTES) REF HAECO NON-ROUTINE NO.9451992,ORIGINAT ED BY EMP V905400, SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905393, IDT BY EMP V907748,REPLACED THE BATTER Y PACK M33306 & PERFORSDR CALA2023041701144Battery · unknownFOUND DOOR L5 EMERGENCY LIGHT BATTERY PACK (M33407) LOW CAPACITY (LESS THAN 15 MINUTES) REF TO HAECO NON-ROUTINE NO.9451990, ORI GINATED BY EMP V905400, SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905393 AND IDT BY EMP V907748 - REPLACED THE B ATTERY PACK M33407SDR CALA2023041701143Battery · unknownFOUND DOOR L2 EMERGENCY LIGHT BATTERY PACK(M33099)LOW CAPACTIRY (LESS THAN 15 MINUTES)REF HAECO NON-ROUTINE NO.9452602,ORIGINATE D BY EMP V905400, SPEC NO.B777-33-3-7019 PERFORMED BY EMP V905393, IDT BY EMP V907748, REPLACED THE BATTE RY PACK M33099 & PERFORMESDR CALA2023041701142Battery · unknownFOUND DOOR L2 EMERGENCY LIGHT BATTERY PACK (M33096) LOW CAPACITY (LESS THAN 15 MINUTES) REF HAECO NON-ROUTINE NO.9452600, ORIGINA TED BY EMP V905400, SPEC NO.B777-33-3-7019 PERFORMED BY EMP V905393, IDT BY EMP V907748,REPLACED THE BATTER Y PACK M33096 & PERFORSDR CALA2023041701141Battery · unknownFOUND DOOR R1 EMERGENCY LIGHT BATTERY PACK (M33094)LOW CAPACITY (LESS THAN 15 MINUTES) REF HAECO NON-ROUTINE NO.9451993,ORIGINAT ED BY EMP V905400, SPEC NO. B777-33-3-7019. PERFORMED BY EMP V905393,IDT BY EMP V907748, REPLACED THE BATTER Y PACK M33094 & PERFORSDR CALA2023041401110Battery · failedOFAR EMERGENCY LIGHT BATTERY PACK M33143(LH) FAIL TEST. P/N:D717 -01-100 AND S/N:426922 OFAR EMERGENCY LIGHT BATTERY PACK M33143(LH) REPLACED AND OPERAT ION TEST CARRIED OUT FOUND SATISFACTORY AMM 33-51-06. TASK ACCOM PLISHED BY V943525.SDR CALA2023032000802Battery · failedB777-33-3-7019 CABIN EMER LT DEEP CYCLE CAPACITY TEST FOUND R2 DR (M33097) BATTERY FAIL. TRANSFER REF NON - ROUTINE WO.1578450 AND ORIG BY V897794 R2 DR BATTERY (M33097) REPLACED AND TEST NORMAL AS PER AMM23-51-06 WORK ACCOMP BY MECH V920572 AND INSP BY V92699SDR CALA2023032000801Battery · failedB777-33-3-7019 CABIN EMER LT DEEP CYCLE CAPACITY TEST FOUND L5 DR (M33407) BATTERY FAIL TRANSFER REF NON - ROUTINE WO.1578459 AND ORIG BY V897794 L5 DR BATTERY (M33407) REPLACED AND TEST NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V920572 AND INSP BY V926996SDR CALA2023031300723Battery Pack · no testEMERGENCY LIGHT BATTERY PACK AT DOOR 4R FAILED OPERATIONAL CHECK REF SIAEC N/R ELE0068 POWER SUPPLY BATTERY PACK AT DOOR 4R (M33401) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0068SDR CALA2023031300730Battery Pack · no testEMERGENCY LIGHT POWER SUPPLY BATTERY PACK AT DOOR 4L FAILED OPER ATIONAL TEST. REF SIAEC N/R ELE0070 POWER SUPPLY BATTERY PACK AT DOOR 4L (M33400) REPLACED AND TESTE D STIAFACTORY AS PER AMM 33-51-06. WPB L3035, REF SIAEC N/R ELE0070
Back to Boeing 777-300ER