Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777FZB' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777FZB' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR P5CA2023033100007Battery · unknownR1 ENTRY DOOR EPAS BATTERY DEAD(<P><SPAN>REMOVED AND REPLACED R/H MAIN ENTRY DOOR EPAS BATT, OPS CHECK OK PER AMM 52-11-20. DMI CLEARED PLACARD REMOVED.</SPAN></P>)SDR P5CA2023011730003Switch · faultedEMERGENCY LIGHTS SWITCH DOES NOT STAY IN ARMED POSITION, WHEN GUARD IS CLOSED RATHER IT MOVES TO THE OFF POSITION. COCKPIT EMERGENCY LIGHT SWITCH GUARD REPLACED AND CHECK OK IAW IPC 33-51-01A ITEM 10 REV JAN 2023 AND LIGHT CHECK OK.SDR P5CA2023011000001Selector · looseCAPT OXYGEN MASK EMERGENCY TEST SELECTOR IS LOOSE(<P>PERFORMED MASK AND DEMAND REGULATOR INSPECTION IAW AMM 35-11-18-210-801. OPS CHK NORMAL</P>)SDR P5CA2022112200206Flashlight · inoperativeL1 DOOR EMERGENCY FLASHLIGHT INOP ( FLASHLIGHT HOLDER ASSEMBLIES (INCLUDING FLASHLIGHT) - ( MAY BE INOPERATIVE OR MISSING PROVIDED CREWMEMBER HAS A FLASHLIGHT OF EQUIVALENT CHARACTERISTICS READILY AVAILABLE). )(<P>R/R FLASHLIGHT AT L1 DOOR IAW B777 AMM 25-64-0SDR P5CA2022111000203Battery Pack · inoperativeRH EXTERIOR EMERGENCY LIGHT FOR R1 DOOR. R & R RH BATTERY PACK IAW AMM 33-51-06. OPS CHECK GOOD. PN D717-02-001.SDR P5CA2022092100173Light · noneAREA EMERGENCY LT AT SUPERNUMERARY COMPARTMENT INOP(<P><SPAN>RELAMPED AREA EMERGENCY LT ABOVE 2ND SUPERNUMERARY SEAT IAW AMM 33-51-03, CKD OK.</SPAN></P>)SDR P5CA2022090800171None · nonePILOT MEDICAL COMPANION KIT WARRANTY OVER EXPIRE.(<P>REMOVED AND REPLACED PILOT MEDICAL COMPANION KIT AND CHECK OK PER AMM 25-64-50/601.</P>)SDR P5CA2022081500166Elt · intermittentELT ON ADVISORY MSG INTERMITTENT IN FLT(<P>NO ACTIVE MSG, ELT CHKS OK PER AMM 25-63-01.</P>)SDR P5CA2022071100146Switch · out of positionEMERGENCY LIGHTS SWITCH MUST BE SLIGHTLY FORWARD TO OFF IN ORDER TO DISARM LIGHTS(PERFORMED OPS TEST IAW AMM 33-51-00-710-803, TEST PASSED)SDR P5CA2022062500145Drive Unit · inoperativeWX RADAR INOP(REMOVED& AND REPLACED WXR ANTENNA DRIVE UNIT PER AMM 34-43-03 / 401. THEN WEATHER RADAR SYSTEM OPERATIONAL. TEST OK PER AMM 34-43-00-710-804-002. NO EXISTING FAULT FOUND, A/C OK FOR SVC.)SDR P5CA2022062200142Seal · tornFO SLIDE WINDOWS HAD LOUD NOISE FROM LOWER LEFT PORTION OF WINDOW, HAPPENED IN CLIMB THROUGH 24,000FT CONTINUED TO 30,000FT. STOPPED DESCENDING THROUGH 23,000FT STEP CLIMB BACK TO 30,000FT WITH NOISE RETURNING BUT QUIETER THAN PREVIOUS EVENT. NO EICAS INDICATOSDR P5CA2022061600141Steering Sys · warning messageCONFIG MASTER WARNING MAIN GEAR STEERING ECIAS MSG(TRANSFER TO MDDR #167143 CAT "C" DUE DATE 26 JUN 22 IAW MEL 32-53-01)SDR UIEA2022061400607Bulb · inoperative2X O/H EMERG LTS INOP IN GALLEY AREA PER LBA RAMP INSP. RELAMPED O/H GALLEY EMERG LTS IN CTR & LH POS IAW AMM 33-51-03, OPS CHECK GOOD</P>)SDR UIEA2022061300580Bulb · inoperative2 X O/H EMRG LTS INOP IN GALLEY AREA PER LRA RAMP INSP.(RELAMPED O/H GALLEY EMERG LTS IN CTR & L/H POS IAW AMM 33-51-03, NOW OPS SATIS.</P>)SDR UIEA2022060700572Light · illuminatedAFTER SECURE CHECKLIST EMERGENCY LIGHTS REMAINED ILLUMINATED WITH SWITCH OFF. PERF EMERG LT OPS TEST EXCERCISED SW ASSY ALL OPS FND SATIS AMM 33-51-00SDR UIEA2022031100196Lamp · inoperativeEMERGENCY LIGHT NOT ON (L1 DOOR LWR FWD)(<P>REMOVED AND REPLACED WITH NEW LAMP AND THEN OPERATION CHECKED NORMAL IAW AMM 35-51-00.</P>)SDR UIEA2022030900194Flashlight Assy · failed inspFO SIDE FLASHLIGHT DOES NOT TEST(<P>TRANSFERRED TO MDDR 162327 IAW MEL 25-64-02, CAT C.</P> / <P>LP 1598900- REMOVED AND REPLACED FIRST OFFICER FLASHLIGHT IAW AMM 25-64-01. OPS CHECK GOOD. THIS CLEARS MDDR 162327. PLACARDS REMOVED.</P>)SDR UIEA2022021900147Bulb · none2 EACH AREA EMERGENCY LIGHTS INOP.(<P>RELAMPED BULBS IAW AMM 33-51-03. OPS CHECK GOOD </P>)SDR UIEA2022011700035Ring · noneFX - LAVATORY SERVICE PAN BTN STA 755.5 AND STA 772 STR 42R AND STA 44R FOUND CORROSION(<P>FX - LAVATORY SERVICE PEN BTN SKIN DOUBLER RING REPLACED AS PER SRM 51-10-02 AND NEW DOUBLER RING INSTALLED AS PER SRM 51-40-02</P>)SDR UIEA2022011700036None · noneCUSTOMER REQUEST - PLEASE CARRY OUT MDDR 126200 DENT MARK ACCESSMENT AT FX SKIN FWD OF BS 228 BTN S-34R TO S-36R(<P>FX - RH SKIN DENT 1 LOCATED AFT OF BS 220.5 AND DENT 2 LOCATED AFT OF BS 228.5, BOTH DENTS BTN S-34R TO S-36R INTERIM REPAIRED AS PER RI NO. RI-SDR UIEA2022011700037None · noneCUSTOMER REQUEST - PLEASE CARRY OUT MDDR 126201 DNET MARK ACCESSMENT AT FX SKIN FWD OF STA 220 BTN S-34R TO S-36R(<P>FX - RH SKIN DENT 1 LOCATED AFT OF BS 220.5 AND DENT 2 LOCATED AFT OF BS 228.5, BOTH DENTS BTN S-34R TO S-36R INTERIM REPAIRED AS PER RI NO.RI-SDR UIEA2022011700038None · noneM/D - STA 1035 RBL 6.5 FLOOR FITTING FOUND CORROSION(<P>M/D - STA 1035 RBL 6.5 FLOOR FITTING CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700039None · noneM/D STA 1035 LBL 6.5 FLOOR FITTING FOUND CORRODED(<P>M/D STA 1035 LBL 6.5 FLOOR FITTING CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700040None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1310(<P>M/D - RBL 6.5 FLOOR FITTING STA 1310 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700041None · noneM/D - LBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1392(<P>M/D - LBL 6.5 FLOOR FITTING STA 1392 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700042None · noneM/D - LBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1350(<P>M/D - LBL 6.5 FLOOR FITTING STA 1350 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700043None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1413(<P>M/D - RBL 6.5 FLOOR FITTING STA 1413 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700044None · noneM/D - LBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1270(<P>M/D - LBL 6.5 FLOOR FITTING STA 1270 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700045None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1434(<P>M/D - RBL 6.5 FLOOR FITTING STA 1434 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700046None · noneM/D - LBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1335(<P>M/D - LBL 6.5 FLOOR FITTING STA 1335 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700047None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1350(<P>M/D - RBL 6.5 FLOOR FITTING STA 1350 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700048None · noneM/D - LBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1292(<P>M/D - LBL 6.5 FLOOR FITTING STA 1292 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700049None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1392(<P>M/D - RBL 6.5 FLOOR FITTING STA 1392 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700050None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1292(<P>M/D - RBL 6.5 FLOOR FITTING STA 1292 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</P>)SDR UIEA2022011700051None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1335(<P><SPAN>M/D - RBL 6.5 FLOOR FITTING STA 1335 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</SPAN></P>)SDR UIEA2022011700052None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1270(<P><SPAN>M/D - RBL 6.5 FLOOR FITTING STA 1270 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</SPAN></P>)SDR UIEA2022011700053None · noneM/D - RBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1371(<P><SPAN>M/D - RBL 6.5 FLOOR FITTING STA 1371 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</SPAN></P>)SDR UIEA2022011700054None · noneM/D - LBL 6.5 FLOOR FITTING FOUND CORROSION AT STA 1434(<P><SPAN>M/D - LBL 6.5 FLOOR FITTING STA 1434 CORROSION AREA BLENDED OUT AND REPROTECTED AS PER SRM 53-00-52-1A-3</SPAN></P>)SDR UIEA2022011900067None · noneRHW O/B T/E FLAP TE LWR SKIN MID AREA FOUND DELAMINATION(<P>PERFORMED COMPOSITE REPAIR AT <SPAN>RHW O/B T/E FLAP TE LWR SKIN DELAMINATION AREA AS PER SRM 51-70-04 REPAIR 1</SPAN></P>)SDR UIEA2022011900068None · noneLHW O/B T/E FLAP TE LWR SKIN MID AREA FOUND DELAMINATION(<P>PERFORMED COMPOSITE REPAIR AT LHW O/B T/E FLAP TE LWR SKIN DELAMINATION AREA AS PER SRM 51-70-04 REPAIR 1</P>)SDR UIEA2021122102475Seal · noneR1 FLASHLIGHT SEAL BROKEN(<P>TRANSFER TO MDDR # 158722, MEL 25-64-02, CAT: C, DUE: 30DEC21. MCC TODD DISP: JM 165Z.</P> / <P>LP 145964 ITEM 3 CVG - REMOVED AND REPLACED TAMPER SEAL PER 777 LOPA MANUAL. THIS CLEARS MDDR 158722. PLACARDS REMOVED, 2142 Z AL,TDC<SDR Q2SA20210826454Line · leakingWHILE EN-ROUTE (ANC-JFK) RECEIVED CAUTION "RESERVE BRAKES/STRG" + "HYD QTY LOW C" FOLLOWEED BY "HYD PRESS SYS CÏ¿½. PERFORMED CHECKLIST AND SHUTDOWN ELECT C2 PUMP, THEN AIR C1, THEN AIR C2 HYDRAULIC PUMPS. DIVERTED TO CVG. FOUND LH MLG STEERING ACTUATOR PRESSUSDR P5CA2022071800148Guard · out of positionEMERGENCY LIGHT GUARD KEEPS TURNING SWITCH OFF(FIXED EMER LIGHTS GUARD PER AMM 33-51-00. CONDITION OK)SDR Q2SA20201129442Smoke Warning · false activationAIRCRAFT GROUNDED. DURING APPROACH, LAV SMOKE ALARM SOUNDED. NEGATIVE FIRE FOUND, RESET ALARM. ICN MX RESET THE SELF TEST SWITCH AND THEN OPERATIONS CHECKED NORMAL, AS PER AMM 26-13-00/501.SDR Q2SA20200914435Outflow Valve · inoperativeAIRCRAFT GROUNDED, UNABLE TO CONTROL CABIN ALTITUDE PRESSURIZATION. CABIN PRESSURE OUTFLOW VALVE ASSEMBLY REPLACED, IAW AMM 21-31-03-000-812-002/21-31-03-400-811-002. TEST PASSED AND STATUS CLEARED.SDR Q2SA20200706433Tire · separatedAIRCRAFT GROUNDED. DURING T/O ROLL EXPERIENCED NOSE GEAR SHIMMY. DEPARTURE CONTROL ADVISED THAT TIRE DEBRI WAS REPORTED ON RUNWAY. AFTER LANDING INSPECTION OF NOSE GEAR SHOWS RIGHT RIGHT NOSE TIRE TREAD SHED. BOTH NOSE TIRES REMOVED AND REPLACED IAW AMM 32SDR Q2SA202005150431Slide · unwanted deployAIRCRAFT GROUNDED. R1 DOOR SLIDE DEPLOYED DURING ARMING PROCEEDURES. R-1 DOOR SLIDE REMOVED AS PER AMMM 25-66-01-00-801. R1 DOOR SLIDE DEFERRED PER DDG 52-11-01-02 DMI 128173- CAT C DUE 20 MAY 20SDR Q2SA20200506430Line · leakingAIRCRAFT GROUNDED. AFTER T/O "HYD SYS C QUANTITY LOW". CREW DECLARED EMERGENCY. DETERMINED RIGHT MAIN GEAR STEERING LINE LEAKING , INSTALLED TEMP LINE IAW AMM 32-53-03 LEAK CHECK OK . SERVICED C HYD RES IAW AMM 12-12-01 . 25 GALLONS ADDED.SDR Q2SA2020033129429Elt · inoperativeAIRCRAFT GROUNDED. PORTABLE ELT REPLACED IAW AMM 25-63-01SDR Q2SA20200303428Battery Pack · failedAIRCAFT GROUNDED. W/O 63155 - EMERGENCY LIGHT BATTERY PACK M33093 REPLACED IAW MM 33-51-06-960-802. TEST SATIS.
Back to Boeing 777FZB