SDR ASMF200606012Annunciator · malfunctionedAIRCRAFT RETURNED TO PLATFORM, FMA FAILURE WITH RT SPD FLAGS AND FD IN RT ADI WERE SHOWED. THE FLT GUIDE SYSTEM WAS RESEATED AND AUTO LAND IN BOTH SYSTEM WERE PERFORMED IAW MM 22-13-00, ALL CORRECT.SDR AALA20060396Landing Gear · malfunctionedORD - INFLIGHT NOSE GEAR FAILED TO EXTEND. LANDED AT ORD WITH NOSE GEAR UP. AIRCRAFT OUT OF SERVICE FOR EVALUATION AND REPAIRS. ACCOMPLISHED PRE FERRY BILL OF WORK AND INSPECTION. FERRIED ORD TO TUL PER AUTHORIZATION SM6090 FOR REPAIRS.SDR AALA20060392Deflector · brokenORD - RED GEAR LIGHT ON IN FLIGHT WITH GEAR HANDLE UP. UNABLE TO RETRACT GEAR. RETURNED TO ORD AND LANDED WITHOUT INCIDENT. AIRCRAFT OUT OF SERVICE FOR EVALUATION. FOUND BROKEN SPRAY DEFLECTOR. REPLACED SPRAY DEFLECTOR ASSEMBLY. SYSTEM GROUND CHECKED NORSDR ASAA0680716Cusp Web · corrodedCUSP WEB IS CORRODED. REPLACED CUSP WEB PER SRM 51-10-4 AND 51-30-5.SDR ASAA0680715Cusp Web · corrodedCUSP WEB CORRODED. REPLACED CUSP WEB PER SRM 51-10-4 AND 51-30-5.SDR ASAA0680714Floor Panel · puncturedCABIN FLOOR PANEL PUNCTURED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680713Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680712Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED WITH CORRODED INSERTS. REPLACED PANEL.SDR ASAA0680711Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED WITH CORRODED INSERTS. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680710Seat Track · corrodedCABIN FLOOR SEAT TRACK CORRODED. REPLACED TRACK.SDR ASMF200606009Control Cable · brokenAIRCRAFT RETURNED TO PLATFORM, LOSS OF STEERING CONTROL. DURING MAINTENANCE REVISION, THE STEERING CONTROL CABLE WAS DETECTED BROKEN. STEERING CABLE P/N 124D WAS REPLACED IAW MM 32-21-01, ADJUSTMENT AND TEST WERE PERFORMED IAW MM 32-51-00 AND 32-52-06, ALL CORSDR ANCF200600024Engine · malfunctionedPILOT REPORT: DURING CRUISE AT FLIGHT LEVEL OF 300, LEFT OIL TEMPERATURE START TO RAISE ABOVE NORMAL RANGE (BETWEEN 135C TO 162C) WAS NECESSARY TO INCREASE POWER IN LT ENGINE TO MAINTAIN OIL TEMPERATURE BELOW 165C, CHECK LIST WAS ACCOMPLISHED UNSUCCESFULLY, FUSDR AALA20060387Light · inoperativeDFW - SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTING AT SEAT 13D INOPERATIVE AND MISSING LENS COVER. REPLACED LAMPS AND LENS COVER FOR SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTING AT SEAT 13D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0680699Skin · dentedFUSELAGE SKIN DENTED. COLD FORMED SKIN TO ORIGINAL CONTOUR. INSTALLED INTERNAL REPAIR DOUBLER PER SRM 53-04.SDR ASAA0680698Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680697Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680696Floor Panel · crackedCABIN FLOOR PANEL CRACKED. REPLACED FLOOR PANEL PER SRM 53-05 AND DRAWING S4932106.SDR ASAA0680695Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED AND HAS CORRODED INSERTS. REPLACED FLOOR PANEL PER SRM 53-05.SDR AALA20060384Oil System · leakingDFW - AFTER TAKEOFF NOTICED ODOR AND SMOKE IN CABIN. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. FOUND LARGE OIL LEAK ON APU COMPARTMENT AND BLEED DUCT WITH OIL CONTAMINATION. REMOVED APU ASSEMBLY AND CLEANED APU COMPARTMENT. REPLACED WATER SEPARATOR BAGSSDR ASAA0680692Floor Panel · delaminatedCABIN FLOOR PANEL IS DELAMINATED AND HAS CORRODED INSERTS. REPLACED PANEL PER SRM 53-05 AND DWG S4932106.SDR AALA20060383Battery · dirtySFO - EMERGENCY EXIT SIGN LIGHT ABOVE ROW 21A TO 21E INOPERATIVE. CLEANED EMERGENCY BATTERY FOR INOPERATIVE EMERGENCY EXIT SIGN LIGHT ABOVE ROW 21A TO 21E. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060380Control Unit · malfunctionedRDU - SEVERAL CIRCUIT BREAKERS POPPED AFTER TAKEOFF. LANDED RDU WITHOUT INCIDENT. SECURED SEVERAL LOOSE WIRES ON RELAY. REPLACED BUS CONTROL UNIT AND TWO A PHASE RIGHT BUS CIRCUIT BREAKERS AND ONE A PHASE GROUND SERVICE BUS POWER CIRCUIT BREAKER. SYSTEM GRSDR AALA20060371Battery Pack · dischargedLAX - EMERGENCY LIGHTS FROM FLIGHT ATTENDANTS PANEL INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS FROM FLIGHT ATTENDANTS PANEL. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ANCF200600022Line · brokenPILOT REPORT: AFTER TAKEOFF, DURING INITIAL CLIMB THE TAIL COMPARTMENT TEMPERATURE HIGH ANNUNCIATION CAME ON WITH RESPECTIVE CHECK LIST PERFORMED, NO HELP ON THE LT SIDE PROCEDURE, AFTER THAT, BOTH THROTTLES REDUCED FOR DESCENT THEN LIGHT WENT OFF. IAW AMM 2SDR AALA20060368Oxygen Bottle · leakingINFLIGHT - CREW OXYGEN PRESSURE LOW. LANDED MSY WITHOUT INCIDENT. FOUND LEAK AT CAPTAIN SIDE OXYGEN EMERGENCY SUPPLY. REPLACED CREW OXYGEN BOTTLE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060370Valve · stuckPVR - INFLIGHT, LEFT ENGINE OIL TEMPERATURE 175 DEGREES WITH FUEL HEAT ON. RETURNED TO PVR AND LANDED WITHOUT INCIDENT. FOUND FUEL HEAT VALVE STUCK OPEN. ACCOMPLISHED ENGINEERING PRE FERRY BILL OF WORK. REPLACED LEFT ENGINE AT DFW. SYSTEM GROUND CHECKED NSDR AALA20060363Battery Pack · dischargedSFO - EMERGENCY LIGHTS AT RIGHT HAND FORWARD LOWER OVERWING EXIT INOPERATIVE. REPLACED BATTERY PACK IN CENTER AFT FOR EMERGENCY LIGHTS AT RIGHT HAND FORWARD LOWER OVERWING EXIT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060362Battery Pack · dischargedSFO - OVERHEAD EMERGENCY LIGHTS AT ROWS 23 TO 27 ARE INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY LIGHTS AT ROWS 23 TO 27. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0680665Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680677Seat Track · corrodedCABIN FLOOR TRACK CORRODED. REPLACED DAMAGED SECTION OF TRACK PER SRM 51-10-4, 51-10-3 AND 51-30-1.SDR ASAA0680676Seat Track · corrodedCABIN FLOOR TRACK CORRODED. REPLACED DAMAGED SECTION OF TRACK PER SRM 51-10-4 , 51-10-3 AND 51-30-1.SDR ASAA0680675Seat Track · corrodedCABIN SEAT TRACK CORRODED. REPLACED DAMAGED SECTION OF TRACK WITH INSTALLATION OF TWO REPAIR CHANNELS AND TWO REPAIR PLUGS PER SRM 53-05.SDR ASAA0680674Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680673Floor Panel · delaminatedCOCKPIT FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680672Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680671Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED AND HAS MISSING INSERTS. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680670Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED AND HAS DAMAGED INSERTS. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680669Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED. REPLACED PANEL PER SRM 53-05.SDR ASAA0680668Floor Panel · crackedCABIN FLOOR PANEL CRACKED. REPLACED FLOOR PANEL.SDR ASAA0680667Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED AND PUNCTURED. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680666Floor Panel · delaminatedCABIN FLOOR PANEL DELAMINATED AND MISSING INSERTS. REPLACED FLOOR PANEL PER SRM 53-05.SDR ASAA0680680Structure · chippedLEFTHAND AILERON T/E COMPOSITE CHIPPED. BOND REPAIRED PER SRM 51-90-0.SDR ASAA0680679Wedge · gougedFLAP T/E WEDGE IS GOUGED. REPAIRED PER SRM 51-90-0.SDR ASAA0680678Skin · gougedRIGHTHAND ELEVATOR CONTROL TAB GOUGED. REPLACED DAMAGED SECTION OF TAB SKIN PER SRM 51-70-2.SDR AALA20060348Battery Pack · not seatedLGA - EMERGENCY CEILING LIGHT FROM ROWS 21 TO AFT OF CABIN DOOR INOPERATIVE. RESEATED BATTERY PACK AT ROW 21 FOR EMERGENCY CEILING LIGHT FROM ROWS 21 TO AFT OF CABIN DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20060333Line · leakingDFW - RIGHT ENGINE SHUT DOWN DUE TO LOSS OF OIL QUANTITY. ENGINE OIL QUANTITY WAS ZERO BUT PRESSURE INDICATION WAS STILL 36 PSI BUT DROPPING WHEN SHUTDOWN. OIL TEMPERATURE WAS ABOVE 100 DEGREES CELSIUS. ENGINE WINDMILLED FOR APPROXIMATELY 22 MINUTES WITH 12SDR ASAA0680643Floor Panel · delaminatedFOUND CABIN FLOOR PANEL DELAMINATED AT INSERTS. REPLACED FLOOR PANEL PER SRM 53 05.SDR ASAA0680642Floor Panel · delaminatedFOUND CABIN FLOOR PANEL DELAMINATED AT INSERTS. REPLACED FLOOR PANEL PER SRM 53 05.SDR ASAA0680640Floor Panel · delaminatedFOUND CABIN FLOOR PANEL IS DELAMINATED AND HAS PULLED INSERTS. REPLACED PANEL PER SRM 53 05.SDR ASAA0680636Floor Panel · delaminatedFOUND CABIN FLOOR PANEL HAS WATER DAMAGE AND BROKEN INSERTS. REPLACED PANEL PER SRM 53 05.
Back to Boeing DC-9-83