Service difficulty report · Line · Doug DC983

Difficulty date
June 7, 2006
Submitted
June 12, 2006
Operation
Air carrier
Aircraft
N593AN
Make and model
Doug DC983
Aircraft serial
53093
Aircraft time
33,286 hours, 36,691 cycles
Part
Line
Condition
Broken
Location
Flow Control
Component
Flow Control · Garrettltd
Component part number
39613011
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PILOT REPORT: AFTER TAKEOFF, DURING INITIAL CLIMB THE TAIL COMPARTMENT TEMPERATURE HIGH ANNUNCIATION CAME ON WITH RESPECTIVE CHECK LIST PERFORMED, NO HELP ON THE LT SIDE PROCEDURE, AFTER THAT, BOTH THROTTLES REDUCED FOR DESCENT THEN LIGHT WENT OFF. IAW AMM 21-10-00 /201 BOTH AIR CONDITION WERE INSPECTION CHECK, WAS FOUND LEAK FOR THERMOSTAT PENEUMATIC LT PACK AND LINE BROKEN IN FLOW CONTROL VALVE RT+, WERE REPLACED THERMOSTAT AND FLOW CONTROL VALVE, TEST WITH GROUND PENEUMATIC , SATISFACTORY.

More about the Doug DC-9-83