Boeing DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0580260Splice · corrodedOKC - DURING C-CHECK, FOUND STATION 1155 FRAME SPLICE STRAP IS CORRODED. REMOVED AND REPLACED STRAP. (M)SDR ASAA0580259Skin · gougedOKC - DURING C-CHECK, RIGHT WING INBOARD FLAP GOUGED OUTBOARD OF BUTT JOINT BOTTOM SURFACE. REMOVED DAMAGE, AND INSTALLED DOUBLER IN FLAP SKIN. (M)SDR ASAA0580258Seat Track · corrodedOKC - DURING C-CHECK, FOUND CABIN SEAT TRACK BL 44 STATION 218-237 IS CORRODED. REMOVED AND REPLACED DAMAGED SECTION OF TRACK. (M)SDR ASAA0580257Bear Strap · corrodedOKC - DURING C-CHECK, AFT CARGO COMPARTMENT DOOR CUTOUT BEAR STRAP IS CORRODED AT STATION 1210. REMOVED DAMAGE AND INSTALLED REPAIR INTERNAL FILLER, EXTERNAL DOUBLERS. AFT CARGO DOOR P/N 5936667-51, BEAR STRAP P/N 59364335. (M)SDR ASAA0580256Structure · corrodedOKC - DURING C-CHECK, AFT CARGO COMPARTMENT LONGERON IS CORRODED ON BETWEEN 27R AND 27L. REMOVED AND REPLACED DAMAGED FRAME SEGMENT AND REPAIR ANGLES. (M)SDR ASAA0580255Longeron · corrodedOKC - DURING C-CHECK, FOUND LONGERON 30 IS CORRODED ON FLANGES AT STATION 1237-1241. REMOVED AND REPLACED DAMAGED LONGERON. (M)SDR ASAA0580254Frame · corrodedOKC - DURING C-CHECK, FOUND FRAME AT STATION 1155 CORRODED. REMOVED AND REPLACED DAMAGED FRAME. (M)SDR GTIA050154Push-Pull Rod · disconnectedAFTER INITIAL LEVEL OFF, THE NR 1 ENGINE AT NEAR CLIMB POWER STOPPED RESPONDING TO AUTO-THROTTLE POWER REDUCTION, THROTTLES BECAME SPLIT AND A/T DISCONNECTED. FULL THROTTLE GAVE NO INCREASE IN POWER AND FULL IDLE WOULD DROP NO LOWER THAN 1.64 EPR, ENGINE WAS SDR P9RA20050080Control Valve · frozenDURING TAXI CREW NOTED ELECTRICAL ODOR IN CABIN. RETURNED TO SFB GATE. FOUND WATER DRIPPING FROM RT PACK ONTO HOT DUCTING CAUSING STEAM. INSPECTED ELECTRICAL WIRING IN THE TAIL INTERIOR WITH NO DEFECTS NOTED. ASSIGNED MEL 21-01-01 TO RT PACK. MAINTENANCE SDR CALA0500148Seat Track · corrodedINSPECTION FOUND LEFT O/B SEAT TRACK CORRODED AT STA 1183-1227, LBL 35. THE SEAT TRACK WAS REMOVED AND REPLACED IAW SRM 53-05-00.SDR CALA0500146Seat Track · corrodedINSPECTION FOUND LEFT I/B SEAT TRACK CORRODED AT STA 1085, LBL 22. THE SEAT TRACK WAS REMOVED AND REPLACED IAW SRM 53-05 FIGURE 4F.SDR AALA20050320Module · inoperativeBOS - DURING CHECK FOUND EMERGENCY LIGHTS FROM FIRST CLASS BACK TO ROW 24 INOPERATIVE. REPLACED FIRST CLASS CHARGER AND THREE BATTERY PACKS FOR EMERGENCY LIGHTS FROM FIRST CLASS BACK TO ROW 24. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0580236Cusp Web · corrodedOKC - DURING C-CHECK, FOUND CABIN FLOOR CUSP WEB IS CORRODED. REMOVED DAMAGE AND INSTALLED DOUBLER. (M)SDR ASAA0580253Wire · looseANC LINE CHECK, FOUND AFT EXIT CATWALK SIDE PANEL EMERGENCY LIGHT INOPERATIVE. RESECURED LOOSE WIRE CONNECTOR. LIGHT THEN OPERATED PROPERLY. (M)SDR ASAA0580252Floorboard · delaminatedOKC - DURING C-CHECK, FOUND FLOORBOARD STATION 160 IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)SDR ASAA0580251Frame · corrodedOKC - FOUND DURING C-CHECK, FRAME CORRODED AT STATION 1212. REMOVED DAMAGE AND INSTALLED A REPAIR ANGLE. (M)SDR ASAA0580250Floorboard · delaminatedOKC - DURING C-CHECK, FOUND OVERWING FLOORBOARD AT STATION 827 IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)SDR ASAA0580249Floorboard · delaminatedOKC - DURING C-CHECK, FOUND RIGHT OVERWING FLOORBOARD AT STATION 807 IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)SDR ASAA0580247Skin · dentedOKC - DURING C-CHECK, FOUND FUSELAGE SKIN HAD DENT AT STATION 1220 LEFT 6 INCHES ABOVE CUSP LINE. COLD WORKED DENT AND INSTALLED SKIN AND DOUBLER. (M)SDR ASAA0580246Skin · lightning strikeOKC - DURING C-CHECK, FOUND FUSELAGE SKIN HAS LIGHTNING STRIKE AT STATION 275 BETWEEN L1 AND L2. REMOVED DAMAGE INSTALLED SKIN AND DOUBLER. (M)SDR ASAA0580245Skin · dentedOKC - FOUND DURING C-CHECK, FUSELAGE HAS TWO DENTS AT STATION 233 LONGERON 17 AND 18L. REMOVED DAMAGE, INSTALLED SKIN AND DOUBLER. (M)SDR ASAA0580243Door Frame · crackedOKC - FOUND DURING C-CHECK, FORWARD ENTRY DOOR LEFT DOOR FRAME LOWER FINGER CRACKED. REMOVED DAMAGE INSTALLED FILLER AND DOUBLER. (M)SDR ASAA0580242Cusp Web · corrodedOKC - FOUND DURING C-CHECK, CUSP WEB CORRODED AT STATION 399. REMOVED CORROSION AND INSTALLED SEGMENT AND DOUBLER. (M)SDR ASAA0580241Cusp Web · corrodedOKC - FOUND DURING C-CHECK, CUSP WEB CORRODED AT STATION 1158 TO 1166. REMOVED CORROSION AND INSTALLED SEGMENT AND DOUBLER. (M)SDR ASAA0580240Cusp Web · corrodedOKC - FOUND DURING C-CHECK, CUSP WEB CORRODED AT STATION 416 TO 419. REMOVED CORROSION AND INSTALLED DOUBLER. (M)SDR ASAA0580239Floorboard · delaminatedOKC - DURING C-CHECK, FOUND CABIN FLOORBOARD DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)SDR ASAA0580238Channel · crackedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAT CHANNEL IS CRACKED. REMOVED AND REPLACED DAMAGED HAT CHANNEL. (M)SDR ASAA0580237Channel · gougedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAT CHANNEL IS GOUGED. REMOVED AND REPLACED DAMAGED HAT CHANNEL. (M)SDR ASAA0580235Floorboard · puncturedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAS TWO PUNCTURES AND IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)SDR ASAA0580234Channel · crackedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAT CHANNEL IS CRACKED. REPLACED HAT CHANNEL. (M)SDR ASAA0580233Floor Panel · damagedOKC - FOUND DURING C-CHECK, FLOORBOARD HAS INSERTS PULLED OUT. REPLACED FLOOR PANEL. (M)SDR ASAA0580232Floor Panel · delaminatedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)SDR ASAA0580231Floor Panel · puncturedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS PUNCTURED. REPLACED FLOOR PANEL. (M)SDR ASAA0580230Floorboard · damagedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAS UPPER FACE FIBER DAMAGE. REPLACED FLOOR PANEL. (M)SDR ASAA0580229Floor Panel · delaminatedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)SDR ASAA0580228Floor Panel · delaminatedOKC - FOUND DURING C-CHECK, FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)SDR ASAA0580227Floorboard · tornOKC - FOUND DURING C-CHECK, FLOORBOARD HAD TORN OUT INSERTS. REPLACED FLOOR PANEL. (M)SDR ASAA0580226Floor Panel · crackedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS CRACKED. REPLACED FLOOR PANEL. (M)SDR ASAA0580225Floor Panel · delaminatedOKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)SDR ASAA0580244Floor Panel · corrodedOKC - FOUND DURING C-CHECK, FLOORBOARD HAS THREE CORRODED INSERTS. REPLACED FLOOR PANEL. (M)SDR ASAA0580223Floor Panel · damagedOKC - FOUND DURING C-CHECK, FORWARD ENTRY FLOOR PANEL CORE DAMAGED. REPLACED FLOOR PANEL. (M)SDR ASAA0580222Floor Panel · delaminatedOKC - FOUND DURING C-CHECK, CABIN FLOOR PANEL DELAMINATING. REPLACED FLOOR PANEL. (M)SDR ASAA0580221Floor Panel · delaminatedOKC - FOUND DURING C-CHECK, CABIN FLOOR PANEL EDGES SEPARATING, DELAMINATING. REPLACED FLOOR PANEL. (M)SDR ASAA0580248Skin · dentedOKC - FOUND DURING C-CHECK, FUSELAGE SKIN HAS DENT AT STATION 211 BELOW 14R. RECONDITIONED SKIN AND INSTALLED DOUBLER. (M)SDR CALA0500145Seat Track · corrodedINSPECTION FOUND RT O/B SEAT TRACK CORRODED AT STA 200-256, RBL 40. THE SEAT TRACK WAS REMOVED AND REPLACED IAW SRM 53-05.SDR CALA0500141Web · crackedINSPECTION FOUND A 2 INCH CRACK IN WEB AT AFT SIDE OF MAIN CABIN DOOR JAMB AT STA 210, LONGERON 15L. THE CRACKED AREA OF WEB WAS REMOVED AND A REPAIR WAS INSTALLED IAW ECRA 5314-01010.SDR CALA0500140Web · crackedINSPECTION FOUND A 2 INCH CRACK IN WEB AFT OF MAIN CABIN DOOR AT STA 210, LONGERON 11L. THE CRACKED AREA OF WEB WAS REMOVED AND A REPAIR WAS INSTALLED IAW ECRA 5314-01010.SDR ASAA0580473Floor Support · corrodedOKC - DUIRNG C-CHECK, PASSENGER CABIN FLOOR TRACK CORRODED. REPLACED DAMAGED TRACK. (M)SDR ASAA0580472Floor Support · corrodedOKC - FOUND C-CHECK, PAX CABIN FLOOR TRACK CORRODED. REPLACED DAMAGED TRACK. (M)SDR ASMF200505007Connector · failedAIRCRAFT ARRIVED WITH CAPTAIN REPORT OF VOR NR 2 WITH OSCILLATIONS OF 30 RADIALS AND RIGHT EHSI WITH OFF FLAG IN LEFT RMI. AIRCRAFT WAS SENT TO THE HANGAR AND RMI INDICATOR WIRING WAS CHECKED DETECTING THE LEFT RMI CONNECTOR FAILED, LINES 36, 37 AND 45. CONN
Back to Boeing DC-9-83