Boeing DC-9-83

Service difficulty reports · 16,530

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC983'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20030106Battery · dischargedDFW - DURING OVERNIGHT MAINTENANCE, SEAT MOUNTED EMERGENCY EXIT LIGHTS AT ROWS 1-19 DIM. REPLACED FORWARD AND MID EMERGENCY EXIT LIGHT BATTERIES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jan 24, 2003 · N562AA · Doug DC983 · Emergency LightingSDR ASAA0380099Battery Pack · dischargedPDX - OVERHEAD EMERGENCY SPOT LIGHT FOUND INOPERATIVE AT ROW 8-12. REPLACED ASSOCIATED POWER SUPPLY, BATTERY PACK, B5-101. LIGHT THEN OPERATED PROPERLY. (M)Jan 23, 2003 · N977AS · Doug DC983 · Emergency LightingSDR ASAA0380102Cargo Track · corrodedOAK - FOUND DURING C-CHECK, TIEDOWN TRACK FLOR MOUNT HOLES ARE CORRODED IN AFT CARGO BAY. REPLACED TIEDOWN TRACK PER SRM 51-30-2 AND 51-10-4. (M)Jan 23, 2003 · N962AS · Doug DC983 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0380101Frame · corrodedOAK - FOUND DURING C-CHECK, FRAME IS CORRODED IN AFT CARGO BAY AT FS 1271. CUT OUT CORRODED SECTION. INSTALLED NEW SECTION AND SPLICE PER SRM 51-10-3, 53-01, 51-30-2 AND 53-03. (M)Jan 23, 2003 · N962AS · Doug DC983 · Fuselage Main, FrameSDR AALA20030103Skin · crackedTUL - FOUND FUSELAGE SKIN IS CRACKED THROUGH RIVET STATION 1380 RIGHT SIDE JUST ABOVE PYLON. DOUBLER INSTALLED PER SRM 53-01, FIG 2 SHEET 3 AND AARD 53-30-00-00 REV DATED 8-30-02. (M)Jan 23, 2003 · N593AA · Doug DC983 · Fuselage Main, Plate/SkinSDR ZW0A0301102Battery · dischargedSEVERAL SEGMENTS OF EGRESS LIGHTING WERE INOP. REPLACED BATTERIES IN POWER SUPPLY AT ROW 21 AND RECONNECTED FEED CABLE AT ROW 29. OPS CHECK GOOD.Jan 23, 2003 · N973TW · Doug DC983 · Emergency LightingSDR ZW0A0301101Light · inoperativeEGRESS LIGHTS INOP IN ROW 16 THROUGH 25. REPLACED SEVERAL LAMPS IN EGRESS LIGHT SYSTEM AND OPS CHECK NORMAL PER MM. LAST CHECK-C STL 5-20-02. --CLOSED--Jan 23, 2003 · N963TW · Doug DC983 · Emergency LightingSDR ASAA0380098Skin · corrodedOAK - DURING C-CHECK, RIGHT WING TO BODY AFT FILLET PANEL LOWER RUB STRIP HAS LIGHT SURFACE CORROSION AROUND FASTENER AND RUBSTRIP. CUT OUT CORRODED SECTION AND INSTLALED DOUBLER AND TRIPLER PER SRM 53-04. (M)Jan 22, 2003 · N962AS · Doug DC983 · Fuselage Main, Plate/SkinSDR ASAA0380100Heat Exchanger · cloggedOAK - HOT INSULATION ODOR AND BLUE HAZE IN CABIN WITH APU ON AND AIR CON PACKS ON. REPLACED BOTH PRIMARY AND SECONDARY (P/N 18406032, S/N 46-5085) HEAT EXCHANGERS, BOTH HAD INGESTED INSULATION BLANKET MATERIAL. OPS CHECK OK. (M)Jan 22, 2003 · N965AS · Doug DC983 · Cabin Cooling SystemSDR ASAA0380097Web · corrodedOAK - DURING C-CHECK, FOUND CABIN FLOOR MEMBRANE (WEB) CORRODED ON UNDERSIDE AT FS 1136-1174. CUT OUT CORRODED SECTION AND INSTALLED DOUBLER PER SRM 53-01, 51-30-2, AND 51-10-33. (M)Jan 22, 2003 · N962AS · Doug DC983 · Fuselage Miscellaneous StructureSDR ASAA0380094Frame · corrodedOKC - FOUND DURING C-CHECK, AFT LOWER FLANGE FRAME CORRODED AT FS 1231. REPLACED DAMAGED SECTION OF FRAME PER SRM 53-03. (M)Jan 21, 2003 · N965AS · Doug DC983 · Fuselage Main, FrameSDR AALA20030086Battery · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT OVERHEAD LIGHTS IN AFT GALLEY AREA INOPERATIVE. RESEATED EMERGENCY EXIT LIGHT BATTERY FOR AFT GALLEY AREA. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jan 21, 2003 · N76200 · Doug DC983 · Emergency LightingSDR AALA20030088Wire · damagedDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT SIDEWALL LIGHTS INOPERATIVE. REPAIRED WIRE ON EMERGENCY EXIT SIDEWALL LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jan 21, 2003 · N565AA · Doug DC983 · Light System WiringSDR ZW0A0301001Battery · dischargedDEPLETED BATTERIES IN EMERGENCY LIGHTING. REPLACED BATTERIES AND CHECKS MADE PER MM33-59-00.Jan 21, 2003 · N9403W · Doug DC983 · Emergency LightingSDR ASAA0380096Nut · loosePDX - DURING PREFLIGHT CHECK, THE FIRST OFFICERS SLIDING CLEARVIEW WINDOW WAS FOUND TO BE DIFFICULT TO OPEN. AFT TRACK BLOCK SECURING NUT HAD BECOME LOOSE. RESECURED AFT TRACK BLOCK. WINDOW THEN OPERATED PROPERLY. (M)Jan 20, 2003 · N964AS · Doug DC983 · Flight Compartment WindowsSDR AALA20030101Structure · crackedTUL - FOUND FS 1418 CRACKED AT 2R. INSTALLED DOUBLER PER 53-01-00 AND AARD 53-10-00-15. (M)Jan 20, 2003 · N598AA · Doug DC983 · Fuselage Miscellaneous StructureSDR AALA20030100Skin · corrodedTUL - FOUND CORROSION AROUND ANTENNA CUTOUT 1 INCH HOLE STATION 380. REMOVED LIGHT CORROSION BY BLENDING PER SRM 51-10-03. (M)Jan 20, 2003 · N598AA · Doug DC983 · Fuselage Main, Plate/SkinSDR AALA20030099Attach Angle · crackedTUL - FOUND LEFT AFT END OF VERTICAL STAB JOINT IS CRACKED BETWEEN FASTENERS .5 INCH. INSTALLED SKATE ANGLE REPAIR DOUBLER PER AARD 53-10-00-2. (M)Jan 20, 2003 · N598AA · Doug DC983 · Fuselage, Stabilizer Attach FittingsSDR GTIA030049Tab · deterioratedFTW - RUDDER CONTROL TAB FLAME SPRAY DETERIORATED IN SEVERAL AREAS, FIXED TAB DELAMINATED AND 4 BONDING STRAPS DETERIORATED AND CORRODED. REPAIRED DELAMINATED FIXED TAB. (M)Jan 19, 2003 · N825NK · Doug DC983 · Rudder StructureSDR ZW0A0300901BatteryEMERGENCY LIGHTING SYSTEM BATTERIES IN ROW 9 WERE INOPERATIVE. REPLACED FWD BATTERY PACK PER MM33-53-11. OPS CHECKED NORMAL PER MM33-59-00. CHECK-C 11-19-02-STL. --CLOSED--Jan 19, 2003 · N982TW · Doug DC983 · Emergency LightingSDR ZW0A0300902BulbIN ARM EGRESS FLOOR LIGHT OUT AT ROW 5 DUE TO WEAR OF DESIGN DEFICIENCY. RESEATED BULB IN ROW 5 EGRESS FLOOR LIGHT SOCKET. EMERGENCY EGRESS LIGHT SYSTEM OPS CHECK PER MM33-59-00. CKECK-C 11-19-02 STL. --CLOSED--Jan 19, 2003 · N982TW · Doug DC983 · Emergency LightingSDR WX0400003Filter · cloggedON DEPARTURE FROM STL, AT APPROXIMATELY 80 KNOTS DURING TAKEOFF, THE LEFT ENGINE OIL STRAINER CLOGGING ANNUNCIATOR ILLUMINATED. THE TAKEOFF WAS ABORTED AND THE AIRCRAFT TAXIED BACK TO THE GATE. MAINTENANCE REMOVED AND REPLACED THE MAIN OIL STRAINER. THE SYSJan 18, 2003 · N862GA · Doug DC983 · Engine Oil System (Airframe Furnished)SDR ASAA0380095Module · inoperativeSEA - DURING PREFLIGHT CHECK, EMERGENCY TRACK LIGHTING WAS FOUND INOPERATIVE IN 1ST CLASS CABIN. REPAIRED, RECONNECTED LIGHT MODULE. LIGHTS THEN OPERATED PROPERLY. (M)Jan 18, 2003 · N968AS · Doug DC983 · Emergency LightingSDR ASAA0380093Angle · crackedOKC - FOUND DURING C-CHECK, VERTICAL ANGLE IN RIGHT WHEEL WELL IS CRACKED AT FORWARD INBOARD LOWER CORNER. REPLACED ANGLE PER SRM 51-30-5. (M)Jan 17, 2003 · N965AS · Doug DC983 · Fuselage Miscellaneous StructureSDR ASAA0380091Cargo Track · corrodedOKC - FOUND DURING C-CHECK, AFT CARGO BAY TIEDOWN BRACKET IS CORRODED. REPLACED BRACKET PER SRM 51-30-5. (M)Jan 17, 2003 · N965AS · Doug DC983 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0380090Spacer · corrodedOKC - FOUND DURING C-CHECK, AFT CARGO BAY DOOR LOWER BEAM SPACER IS CORRODED. REPLACED EXISTING DOUBLER PER SRM 51-30-5 AND 53-05. (M)Jan 17, 2003 · N965AS · Doug DC983 · Fuselage Main, StructureSDR ASAA0380092Cargo Track · corrodedOKC - FOUND DURING C-CHECK, AFT CARGO BAY FLOOR TRACK CORRODED AT FASTENER HOLES. REPLACED FLOOR TRACK PER SRM 53-05 AND 51-10-3. (M)Jan 17, 2003 · N965AS · Doug DC983 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0380089Switch · inoperativeSEA - DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHTING WAS DETERMINED TO BE INTERMITTENTLY INOPERATIVE. REPLACED OVERHEAD EMERGENCY LIGHT SWITCH IN COCKPIT. LIGHTS THEN OPERATED PROPERLY. (M)Jan 17, 2003 · N974AS · Doug DC983 · Emergency LightingSDR GTIA030034Angle · corrodedFTW - FOUND MID PIT HAS CORROSION ON 2 ANGLE (FWD) STATION 655-598. REMOVED Z-ANGLE STATION 598-655. FORMED NEW ANGLE. INSTALLED NEW Z-ANGLE IN MID PIT FS 655-598. (M)Jan 17, 2003 · N825NK · Doug DC983 · Fuselage Miscellaneous StructureSDR ZW0A0301106Skin · crackedDURING CHECK-C 4 EACH CRACKS AROUND BOLT HEAD LE HORIZONTAL STABILIZER 1-8 INCH APPROXIMATELY 19 INCHES FROM LE LEFT HAND HORIZONTAL STABILIZER. REPAIR COMPLETED PER SRM 51-70-4.Jan 17, 2003 · N9629H · Doug DC983 · Horizontal Stabilizer, Plate/SkinSDR ZW0A0301105Door Frame · crackedDURING CHECK-C CRACK AT LEFT HAND MAIN GEAR DOOR CUTOUT FORWARD 11B CORNER FORWARD OF DOOR ACTUATOR ASSEMBLY RUNNING OUTBOARD FROM CORNER TURNING UPWARD. ROUTED OUT DAMAGED AREA AND INSTALLED DOUBLER IAW SRM 51-20-5.Jan 17, 2003 · N9629H · Doug DC983 · Fuselage Main, StructureSDR GTIA030029Floorboard · delaminatedFTW - FOUND FLOORBOARD UNDER FORWRAD LAVATORY IS DELAMINATED AROND LAVATORY CONNECTION HOLES, AND FASTENERS ARE CORRODED. REMOVED FLOORBOARD UNDER FORWARD LAVATORY STATION 218-275. REPAIRED FLOORBOARD UNDER FORWARD LAVATORY. INSTALLED FLOORBOARD. (M)Jan 16, 2003 · N825NK · Doug DC983 · Fuselage Floor PanelSDR GTIA030022Isolation Mount · out of adjustDTW - FOUND FORWARD LOWER ISOLATION MOUNT ALIGNMENT MARKS MISMATCHED. REMOVED AND REPLACED FORWARD LOWER ISOLATER MOUNT IAW MD80 MM 71-20-02. (M)Jan 16, 2003 · N824NK · Doug DC983 · Engine Mount SectionSDR AALA20030083Coupling · disconnectedFSD - FLT 1887 - EN ROUTE ORD-SEA, CENTER TANK AT 12,500 LBS, LT MAIN TANK AT 9,400 LBS AND BOOST PUMPS ON, CROSSFEED CLOSED. THE RT MAIN FUEL QUANTITY WAS DECREASING FROM 9,400 LBS. RT MAIN QUANTITY DECREASED 3,000 LBS IN 30 MIN. AILERON TRIM WAS INCREASINJan 16, 2003 · N566AA · Doug DC983 · Fuel Transfer ValveSDR AALA20030064Battery · not seatedDFW - DURING OVERNIGHT MAINTENANCE, TAIL CONE EMERGENCY EXIT LIGHTS INOPERATIVE. RESEATED TAIL CONE EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Jan 15, 2003 · N569AA · Doug DC983 · Emergency LightingSDR ASAA0380078Light · inoperativeSEA - DURING LINE CHECK, EMERGENCY TRACK LIGHTING AT ROW 2 WAS FOUND 'PULLED INOP'. REPAIRED LIGHT MODULE. LIGHTS THEN OPERATED PROPERLY. (M)Jan 15, 2003 · N950AS · Doug DC983 · Emergency LightingSDR GTIA030030Doubler · crackedFTW - FOUND RIGHT ELEVATOR STATION 1417 DOUBLER BENT CRACKED. REMOVED DOUBLER. FABRICATED NEW DOUBLER. INSTLALED NEW DOUBLER. (M)Jan 15, 2003 · N825NK · Doug DC983 · Horizontal Stabilizer StructureSDR ASAA0380087Skin · crackedOKC - FOUND C-CHECK, AFT CARGO BAY BARRIER DOOR INTERNAL SKIN IS CRACKED 1.25 INCH. INSTALLED FILLER AND DOUBLER PER SRM 51-70-2. (M)Jan 14, 2003 · N965AS · Doug DC983 · Fixed Inner DoorsSDR ASAA0380086Cargo Track · corrodedOKC - FOUND DURING C-CHECK, AFT CARGO BAY TIEDOWN TRACK IS CORRODED AROUND FASTENER HOLES. REPLACED TRACK PER SRM 51-10-4 AND 51-30-1. (M)Jan 14, 2003 · N965AS · Doug DC983 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0380085Skin · crackedOKC - FOUND DURING C-CHECK, FORWARD CARGO BAY BARRIER DOOR SKIN CRACKED. INSTALLED FILLER AND DOUBLER PER SRM 51-70-2. (M)Jan 14, 2003 · N965AS · Doug DC983 · Fixed Inner DoorsSDR ASAA0380084Clip · crackedOKC - FOUND DURING C-CHECK, AFT CARGO BAY BRACKET ANGLE CLIP CRACKED. REPLACED CLIP PER SRM 51-30-1. (M)Jan 14, 2003 · N965AS · Doug DC983 · Fuselage Miscellaneous StructureSDR ZW0A0300701BatteryBOTH COCKPIT EMERGENCY LIGHTS FAILED TO ILLUMINATE. REPLACED THE BATTERIES IN THE BATTERY PACK. CHECK-C 11-19-02 STL. --CLOSED--Jan 14, 2003 · N982TW · Doug DC983 · Emergency LightingSDR ASAA0380082Torque Box · corrodedOKC - FOUND DURING C-CHECK, TORQUE BOX WEB UPPER SURFACE CORRODED AT FS 1212. REPLACED WEB SECTION PER SRM 51-70-4. (M)Jan 13, 2003 · N965AS · Doug DC983 · Fuselage Main, StructureSDR ASAA0380081Angle · corrodedOKC - FOUND DURING C-CHECK, AFT CARGO BAY AFT BULKHEAD PANEL MOUNTING STRAP ATTACH ANGLE CORRODED. REPLACED ANGLE PER SRM 51-10-2 AND 51-30-5. (M)Jan 13, 2003 · N965AS · Doug DC983 · Fuselage Miscellaneous StructureSDR ASAA0380079Cargo Track · corrodedOKC - FOUND DURING C-CHECK, AFT CARGO BAY LEFT TRACK IS CORRODED AT FS 1079-1222. REPLACED TRACK PER SRM 53-05. (M)Jan 13, 2003 · N965AS · Doug DC983 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA0380080Hinge · crackedOKC - FOUND DURING 30K CHECK, FORWARD CARGO BAY BARRIER DOOR HINGE IS CRACKED. REPLACED HINGE PER SRM 51-30-1. (M)Jan 13, 2003 · N965AS · Doug DC983 · Fixed Inner DoorsSDR ASAA0380083Floorboard · puncturedOKC - FOUND DURING C-CHECK, FORWARD CARGO BAY NR 4 FLOORBOARD PUNCTURED AND CORRODED. REPLACED FLOOR PANEL PER SRM 51-10-4. (M)Jan 13, 2003 · N965AS · Doug DC983 · Fuselage Floor PanelSDR ASAA0380077Access Panel · crackedOKC - FOUND DURING C-CHECK, ACCESS PANEL BENEATH SEAT IN COCKPIT IS BENT AND TORN. INSTALLED DOUBLER PER SRM 53-01. (M)Jan 13, 2003 · N965AS · Doug DC983 · Fuselage Main, StructureSDR ASAA0380076Hinge · crackedOKC - FOUND DURING C-CHECK, MID CARGO BAY BARRIER DOOR HINGE IS CRACKED. REPLACED HINGE PER SRM 51-10-3, 51-10-4, AND 51-30-1. (M)Jan 13, 2003 · N965AS · Doug DC983 · Fuselage Main, StructureSDR ASAA0380075Plate · crackedOKC - FOUND DURING C-CHECK, MID CARGO BAY DOOR LOWER SCUFF PLATE IS CRACKED. CUT OUT AND REPLACED DAMAGED AREA PER SRM 53-01. (M)Jan 13, 2003 · N965AS · Doug DC983 · Cargo/Baggage Doors
Back to Boeing DC-9-83