Boeing DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA02803345Bracket · crackedOKC - FOUND DURING 30K CHECK, FORWARD CARGO BAY DOOR AFT SIDE STOP, 2ND FROM TOP, BRACKET CRACKED. REPLACED BRACKET PER SRM 51-10-4, 51-30-1, AND 51-30-5. (M)SDR ASAA02803346Bracket · crackedOKC - DURING 30K-CHECK, FOUND AFT CARGO BAY DOOR FORWARD SIDE UPPER STOP BRACKET CRACKED. REPLACED BRACKET PER SRM 51-10-4, 51-30-1, AND 51-30-5. (M)SDR GTIA021225Longeron · corrodedFTW - E/E COMPARTMENT LONGERON 30 STATION 120 TO 133 HAS CORROSION FOUND ON REMOVAL OF BATTERY TRAY TO FOM. DRILLED NEW STRINGER 30. INSTALLED L30. (M)SDR AALA20021388Battery Pack · dischargedBOS - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE PATH LIGHTING SEATS 23, 24 AND 26 INOPERATIVE. REPLACED EMERGENCY ESCAPE PATH LIGHTING BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA021095Longeron · corrodedFTW - E/E COMPARTMENT LONGERON 30 STATION 120 TO 133 HAS CORROSION FOUND ON REMOVAL OF BATTERY TRAY TO FOM. DRILLED NEW STRINGER 30, INSTALLED L30. (M)SDR GTIA021228Structure · crackedFTW - FOUND AFT FUSELAGE STATION 1497 RT AFT PLATFORM IS CRACKED AT RT FRAME. STOP DRILLED CRACK. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)SDR GTIA021121Floor Panel · crackedFLIGHT COMPT, STA 120 TO STA 140.8 FLOOR PANEL HAS CRACK/ CORROSION. FABRICATED NEW FLOOR PANELS. INSTALLED NEW FLOOR PANELS.SDR GTIA021032Intercostal · crackedMAIN CABIN FLOOR STA 1287-1039 BL 0, INTERCOASTAL IS CRACKED FROM AFT EDGE FORWARD INTO LIGHTENING HOLE. REMOVED DAMAGED INTERCOSTAL. FABRICATED A NEW INTERCOSTAL. INSTALLED INTERCOSTAL.SDR GTIA021093Floor Panel · corrodedFTW - FLIGHT COMPARTMENT, FLOOR PANEL STATION 120 TO STATION 160 CENTER SOFT/MUSHY CORROSION. FABRICATED NEW FLOORBOARD. INSTALLED NEW FLOORBOARD. (M)SDR GTIA021092Fitting · corrodedFTW - FOUND PASSENGER CABIN, RIGHT STATION 120 TO 200 HAS TWO FITTINGS CORRODED. LOCATED AND DRILLED NEW FITTINGS. INSTALLED NEW FITTINGS. (M)SDR GTIA021091Floorboard · corrodedFTW - FOUND FLOORBOARD RIGHT OUTBOARD STATION 196 TO 256 SOFT/MUSHY CORROSION. FABRICATED FLOORBOARD. INSTALLED FLOORBOARD. (M)SDR GTIA021090Floorboard · damagedFTW - FOUND FLOORBOARD LEFT INBOARD STATION 160 TO 196 CRACKED/DAMAGED AND CORRODED. FABRICATED NEW FLOORBOARD. INSTALLED FLOORBOARD. (M)SDR GTIA021089Floorboard · damagedFTW - FOUND FLOORBOARD LEFT INBOARD STATION 160 TO STATION 196 SOFT/MUSHY CORRODED. FABRICATED FLOOR PANEL. INSTALLED FLOOR PANEL. (M)SDR GTIA021088Floorboard · damagedFTW - FOUND FLOORBOARD RIGHT INBOARD STATION 160 TO STATION 180 SOFT/DAMAGED. FABRICATED FLOORBOARD PANEL. INSTALLED FLOORBOARD PANEL. (M)SDR GTIA021087Floorboard · crackedFTW - FOUND FLOORBOARD RT INBOARD STATION 180-200 CRACKED/DAMAGED/CORRODED. FABRICATED FLOOR BOARD. INSTALLED FLOORBOARD. (M)SDR GTIA021086Floor Panel · crackedFTW - FLIGHT COMPARTMENT, COPILOT SIDE STATION 148, FLOOR PANEL IS CRACKED/DAMAGED AT CORNERS, 2 EACH PLATE ATTACH PANEL IS CORRODED. FABRICATED NEW PANEL. INSTALLED NEW PANEL. (M)SDR GTIA021129Intercostal · corrodedAFT FUSELAGE, LEFT STA 1380 TO STA 1401, CORRODED AT INTERCOSTAL. REMOVED INTERCOSTAL, FABRICATED NEW INTERCOSTAL, INSTALLED NEW INTERCOSTAL.SDR GTIA021128Support Bracket · damagedAFT FUSELAGE STA 1380 LOWER ANGLE CAP SUPPORT AFT CANTED BULKHEAD. REMOVED LOWER (T) ANGLE, LOCATED AND DRILLED NEW LOWER (T) ANGLE. INSTALLED NEW (T) ANGLE.SDR GTIA021120Floorboard · delaminatedLT AFT LAV ASSY, SEVERAL AREA OF DELAMINATED AND DAMAGED FLOORBOARD SUPPORT LAV ASSY. FABBED NEW LAV FLOOR BOARD, INSTALLED NEW LAV FLOORBOARD.SDR GTIA021046Floorboard · crackedFLOORBOARDS, STA 160 TO STA 190 RIGHT CENTER PANEL IS CRACKED AND DELAMINATED, CORRODED. FABRICATED NEW FLOORBOARD, INSTALLED NEW FLOORBOARD.SDR ZW0A0210202Odor · detectedA VERY STRONG FUEL ODOR WAS REPORTED IN COCKPIT AND SLIGHTLY IN C ABIN. FLIGHT RETURNED TO STL. UNABLE TO FIND ANY FUEL LEAK. CHANGED THE WATER SEPERATORS AND ACCOMPLISHED A PACK BURN OUT TO ELIMINATE THE ODOR.SDR GTIA021113Doubler · corrodedFTW - FOUND VENTRAL STAIRWAY JAMB CORRODED AT LT SIDE STATION 1418-1485. AFTER CLEANING FOUND EXFOLIATED DOUBLER. REMOVED EXFOLIATED DOUBLER. FABRICATED ANGLE. INSTALLED ANGLE. (M)SDR GTIA021127Attach Angle · corrodedAFT FUSELAGE STA 1437 TO STA 1418 CORRODED AT AFT ANGLE ATTACH TO FLANGE APU GROUND CONTROL AND FIRE DOOR. REMOVED CORRODED ANGLE, FORMED NEW ANGLE, INSTALLED NEW ANGLE.SDR ASAA0280334Frame · corrodedOKC - 30K CHECK, AFT CARGO FRAME CORRODED BEYOND LIMITS AT STATION 1174. REPLACED FRAME AT STATION 1174 LONGERON 28R-27L PER SRM 51-30-5 AND 51-30-2. (M)SDR GTIA021227Floorboard · damagedFTW - FORWARD LAVATORY EQUIPMENT DAMAGED AT FLOORBOARD SUPPORT. REMOVED DAMAGED FLOORBOARD FORWARD LAVATORY. FABRICATED NEW FLOORBOARD FORWARD LAVATORY. INSTALLED NEW FLOORBOARD FORWARD LAVATORY. (M)SDR GTIA021161Floor Support · corrodedFTW - FOUND FORWARD CARGO STRINGER 29R FLOOR SUPPORT CORRODED FS 351-427. REMOVED FLOOR SUPPORT. INSTALLED SUPPORT FLOOR. (M)SDR GTIA021112Skin · corrodedFTW - FOUND MID CARGO PIT FS 520-693 SKIN CORRODED BETWEEN LONGERONS 27L-27R. FABRICATED DOUBLER. INSTALLED DOUBLER. (M)SDR GTIA020999Odor · detectedMCO - FLT 1865 - STRONG OIL/BURN SMELL AFTER ROTATION AT LGA-HEAVY RAIN, APU ON, RIGHT CABIN TEMP HOT. STOPPED AFTER APU SHUTDOWN AND RIGHT TEMP TO AUTO. NO FURTHER PROBLEM OR SMELL DURING FLIGHT. INSPECT APU AND ACM'S OIL LEVELS NORMAL AND CLEAN. RAN BOTHSDR GTIA021068Longeron · corrodedAFT CARGO COMPARTMENT, STA 1297, LONGERON 23R HAS CORROSION THROUGH THE METAL. REMOVED CORRODED LONGERON, CUT NEW LONGERON. FABRICATED SPLICES, INSTALLED LONGERON SECTION AND SPLICES.SDR GTIA021144Stringer · corrodedFTW - FOUND FORWARD CARGO PIT STRINGER 30 CORRODED FROM FS 389-446, FORWARD CARGO FS 389-408 STRINGER 30 CORRODED. FOUND FORWARD CARGO FS 427-446 STRINGER 30 CORRODED, FORWARD CARGO FS 408-427 STRINGER 30 CORRODED. (M)SDR GTIA021169Stringer · corrodedFTW - FOUND MID CARGO PIT STRINGER 29R CORRODED AT FS 712-750, FS 788-817. MID CARGO FS 712-731 STRINGER 29R CORRODED. MID CARGO FS 731-750 STRINGER 29R CORRODED. MID CARGO STRINGER 29R CORRODED FS 807-817. MID CARGO FS 807-788 STRINGER 29R CORRODED. REMOSDR GTIA021166Stringer · corrodedFTW - FOUND FORWARD CARGO PIT STRINGER 29L CORRODED AT FS 376-446. FORWARD CARGO FS 427-446 STRINGER 29L CORRODED. FORWARD CARGO FS 408-427 STRINGER 29L CORRODED. FORWARD CARGO STRINGER 29L CORRODED FS 370-389. FORWARD CARGO FS 389-408 STRINGER 29L CORRODESDR GTIA021085Floorboard · damagedFTW - FOUND PASSENGER CABIN, FLOOR PANEL STATION 200-256, SOFT/MUSHY DAMAGED. FABRICATED PASSENGER CABIN FLOOR PANEL. INSTALLED FLOOR PANEL. (M)SDR GTIA021084Floorboard · damagedFTW - PASSENGER CABIN FLOOR PANEL STATION 160 TO STATION 190 GOUGES, SOFT DAMAGE. FABRICATED FLOORBOARD. INSTALLED FLOORBOARD. (M)SDR ASAA0280331Module · disconnectedYVR - DURING PRE-FLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 26. RECONNECTED LIGHT MODULE. LIGHTS THEN OPERATED PROPERLY. (M)SDR ASAA0280330Module · missingSAN - DURING PREFLIGHT CHECK, FOUND ALL BUT ONE EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE THROUGHOUT 1 ST CLASS CABIN. REPLACED MISSING LIGHT MODULE. LIGHTS THEN OPERATED PROPERLY. (M)SDR GTIA021140Longeron · corrodedFTW - AFT PIT CORROSION FS 1250-1287 LONGERON 29R AND LWR SIDE CORRODED AT SPLICE. REMOVED DAMAGED SECTION. FABRICATED LONGERON SECTION. INSTALLED THE LONGERON SECTION. FABRICATED LONGERON SPLICE. INSTALLED SPLICE REPAIR. (M)SDR GTIA021111Floor Support · corrodedFTW - FOUND FLOORBOARD SUPPORT CORRODED RBL 1 STATION 180. FORMED NEW FLOOR SUPPORT. INSTALLED NEW FLOOR SUPPORT. (M)SDR GTIA021110Floor Support · corrodedFTW - FOUND FLOORBOARD SUPPORT CORRODED LBL 51 STATION 160-185. REMOVED SUPPORT ANGLE. FABRICATED SUPPORT ANGLE. INSTALLED FLOOR SUPPORT ANGLE. (M)SDR GTIA021109Floor Support · corrodedFTW - FOUND FLOORBOARD SUPPORT CORRODED LBL 60 STATION 195. FORMED NEW ANGLE FLOOR SUPPORT. INSTALLED FLOOR SUPPORT ANGLE. (M)SDR GTIA021108Web · corrodedFTW - FOUND WEBBING AT FORWARD LAVATORY LBL 41 STATION 233 CORRODED. CUT OUT THE DAMAGED AREA. FABRICATED DOUBLERS REPAIR AND FILLER. INSTALLED DOUBLERS REPAIR AND FILLER. (M)SDR GTIA021107Floor Support · corrodedFTW - FOUND FLOORBOARD SUPPORT LBL 8 STATION 200-256 CORRODED. REMOVED FLOOR SUPPORT. FABRICATED FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)SDR GTIA021052Floor Support · corrodedFLOORBOARD SUPPORT CORRODED, RBL16, STA 200. REMOVED FLOOR SUPPORT, FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT.SDR GTIA021051Floor Support · corrodedFLOORBOARD SUPPORT CORRODED, LBL45, STA200. REMOVED FLOOR SUPPORT, FABRICATED NEW FLOOR SUPPORT, INSTALLED FLOOR SUPPORT.SDR GTIA021050Floor Support · corrodedFLOOR SUPPORT CORRODED LBL63 STA 160-200. REMOVED FLOOR SUPPORT, FABBED NEW FLOOR SUPPORT, INSTALLED FLOOR SUPPORT.SDR GTIA021049Floor Support · corrodedFLOORBOARD SUPPORT STA 218 LBL4, CORRODED. C/A: FABRICATED NEW EXTRUSION FLOORBOARD SUPPORT. INSTALLED FLOORBOARD SUPPORT.SDR CALA0200476Frame · crackedINSPECTION FOUND A 1.25" CRACK IN TAIL COMPARTMENT R/H SIDE CANTED FRAME AT STA 1463, L17R. A REPAIR DOUBLER WAS INSTALLED IAW SRM 53-01, FIGURE 2.SDR GTIA021145Stringer · corrodedFTW - FOUND MID CARGO STRINGER 28L CORRODED FS 576-579. REMOVED DAMAGED AREA. FABRICATED SPLICE ON LONGERON SECTION. INSTALLED SPLICE AND LONGERON. (M)SDR GTIA021165Keelbeam · corrodedFTW - FOUND RIGHT KEEL BEAM INTERIOR STRUCTURE HAS SEVERAL AREAS OF CORROSION STATION 826-843. REMOVED SUPPORT FITTING. REMOVED BATHTUB FITTING. REMOVED CORROSION FROM RIGHT KEEL BEAM HORIZONTAL FLANGE FOUND TO BE OUT OF LIMITS. FABRICATED NEW FITTING AT SSDR GTIA021106Stiffener · crackedFTW - FOUND AFT CABIN STATION 1338 CRACK AT STIFFENER SUPPORT AFT LEFT LOWER DOOR JAMB. REMOVED CRACKED STIFFENER. FABRICATED REPLACEMENT SUPPORT. INSTALLED REPLACEMENT SUPPORT. (M)
Back to Boeing DC-9-83