Boeing DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0080577Light · inoperativePHX - DURING SCHEDULED 30K CHECK, THE L1 DOOR PORTABLE EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. REPLACED PORTABLE LIGHT AND LIGHT OPERATED NORMALLY. (M)SDR ASAA0080578Battery · dischargedPHX - DURING SCHEDULED 30K CHECK, THE OVERHEAD EMERGENCY LIGHTS AT ROWS 1-10 WERE FOUND TO BE INOPERATIVE. REPLACED THE BATTERIES AND THE LIGHTS OPERATED NORMALLY. (M)SDR ASAA0080580Battery · dischargedPHX - DURING SCHEDULED 30K CHECK, THE AFT SERVICE DOOR SLIDE AMP MEASUREMENT WAS FOUND TO BE OUT OF TOLERANCE. REPLACED SLIDE. (M)SDR AALA006137Battery Pack · inoperativeLAX-CCI - SEAT MOUNTED EMERGENCY LIGHTS FROM SEAT 28D THROUGH 31D INOPERATIVE. REPLACED EMERGENCY LIGHTS BATTERY PACK. OPS CHECKS NORMAL. (M)SDR AALA20001525Seat Track · corrodedTUL - FOUND CORROSION ON SEAT TRACK NR 1 STATION 796. REMOVED DAMAGED SECTION, SPLICED IN NEW SECTION PER SRM 53-05 PART 1. (M)SDR TWAA0016111Structure · crackedDURING CHECK-C MAINT, THE LT MLG WHEEL WELL DOOR WAS CRACKED AFT EDGE. STOP DRILLED CRACK. INSTALLED DOUBLER REPAIR PER ILLUSTRATION IN SRM 52-05, FIG 28, SHEET 6.SDR ASAA0080522Power Supply · dischargedSEA - DURING MAINTENANCE CHECK, BOTH EXTERIOR OVERWING EXIT LIGHTS FAILED TO EXTINGUISH. REPLACED THE POWER SUPPLY AND BOTH LIGHTS OPERATED NORMALLY. (M)SDR AALA20001529Longeron · crackedTUL - FOUND NR 4 LONGERON CRACKED AT ATTACH POINT AT FRAME NR 160 LEFT SIDE. REMOVED AND REPLACED LONGERON NR 4 AND SPLICED PER SRM 53-02. (M)SDR AALA20001528Longeron · crackedTUL - FOUND LONGERON NR 3 LEFT CRACKED AT FRAME NR 160 LEFT AT HUCK FASTENER IN LONGERON. INSTALLED LONGERON REPAIR, AS PER SRM 53-02. (M)SDR AALA20001527Web · corrodedTUL - FOUND CORROSION ON CUSP MEMBRANE STATION 1307 LEFT BETWEEN NR 1 AND NR 2 SEAT TRACKS. CUT OUT CORROSION 1 INCH BY 1.5 INCHES AND INSTALLED REPAIR DOBLER PER AARD 53-00-00-2. (M)SDR AALA20001526Web · corrodedTUL - FOUND CORROSION ON CUSP MEMBRANE STATION 801 RIGHT. TRIMMED OUT CORROSION AND INSTALLED REPAIR DOUBLER PER AARD 53-00-00-2 SRM 53-01 FIG 4. (M)SDR AALA20001537Skin · gougedTUL - FOUND 2 DEEP GOUGES IN FIXED L/E AFT OF NR 2 SLAT INBOARD OF NR 7 SLAT TRACK. REPAIRED AFT DAMAGED AREA PER AARD 57-30-00-8. (M)SDR ASAA0080521Wire · disconnectedANC - DURING MAINTENANCE CHECK, SEVERAL EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING/LIGHTS AND ALL LIGHTS OPERATED NORMALLY. (M)SDR COMA0060954Wire · disconnectedANC - DURING MAINTENANCE CHECK, SEVERAL EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING/LIGHTS AND ALL LIGHTS OPERATED NORMALLY. (M)SDR AALA20001522Cargo Track · corrodedTUL - FOUND RIGHT CARGO TIE DOWN TRACK CORRODED IN CENTER OF TRACK STATION 1079 TO STATION 1155, ALSO CORRODED ON OUTBOARD FLANGE STATION 1155. REMOVED TIE DOWN TRACK AND INSTALLED NEW TRACK SRM 51-01. (M)SDR AALA20001523Seat Track · corrodedTUL - FOUND SEAT TRACK NR 2 HAS CORROSION AT STATION 1202. ACCOMPLISHED SEAT TRACK PLUG REPAIR PER AARD 53-20-00-10. (M)SDR TWAA0013402Battery · dischargedTHE EMERGENCY LIGHTS WERE INOPERATIVE AT THE L1, R1, AND R2 SERVICE DOORS, AND COCKPIT OVERHEAD, AND THE LT AND RT AUX EXIT IDENTIFIERS. REPLACED THE EMERGENCY LIGHT BATTERIES IN THE BATTERY PACKS AT B5-23, B5-101, AND B5-107. CHECK-C 8-5-00 JFK.SDR AALA20001429Slide · deployedBNA - AT GATE, TAILCONE SLIDE WAS INADVERTENTLY DEPLOYED. INITIALLY INFLATED THEN DEFLATED AFTER TOUCHING GROUND. REPLACED SLIDE. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR TWAA0013305Lavatory · fireSMOKE CAME FROM THE RT LAVATORY WASTE AREA. CREW EXTINGUISHED FIRE IN WASTE BASKET USING WATER FROM THE LAVATORY. SUSPECT CAUSED BY A CIGARETTE. THE FIRE DETECTION AND EXTINGUISHING SYSTEMS HAD NOT YET ACTIVATED BUT WERE OPERATIONALLY CHECKED NORMAL. CHECKSDR TWAA0013301Light · inoperativeTHE PORTABLE HANDHELD EMERGENCY LIGHT WAS INOPERATIVE AT THE LT SIDE MOST FORWARD CABIN DOOR. REPLACED THE LIGHT ASSEMBLY. CHECK-C 6-3-00 STL.SDR AALA006135Wire · brokenRNO - EMPENNAGE O/H WALKWAY EMERGENCY LIGHT INOPERATIVE. REPAIRED BROKEN WIRE AND RELAMPED. OPS CHECK GOOD. (M)SDR TWAA0013302Light · inoperativeTHE HAND HELD PORTABLE EMERGENCY LIGHT AT THE LEFT SIDE MOST FORWARD CABIN DOOR WAS INOPERATIVE. REPLACED THE LIGHT ASSEMBLY. CHECK-C 5-6-00 STL.SDR ASAA0080516Latch · out of adjSEA - PRIOR TO F608, THE L1 DOOR WAS DIFFICULT TO OPEN. ADJUSTED DOOR AND DOOR OPERATED NORMALLY. (M)SDR ASAA0080515Latch · lack of lubeMLAX-THE L1 DOOR HANDLE WAS FOUND TO BE STIFF DURING CLOSING.LUBRICATED DOOR AND DOOR OPERATED NORMALLY.SDR AALA006136Wire · brokenSJC-CCI - EMERGENCY LIGHT ON SEAT ROW 12 INOPERATIVE. FOUND WIRE BROKEN, RECONNECT WIRES, OPS CHECKS GOOD. (M)SDR AALA006134Battery Pack · dischargedRNO-CCI - ROW 29-32 EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK, OPS CHECK GOOD. (M)SDR AALA20001384Seat Track · corrodedTUL - FOUND CORROSION ON SEAT TRACK NR 6. REMOVED AND REPLACED SECTION OF SEAT TRACK BETWEEN FACTORY SPLICES AND INSTALLED NEW SPLICES SRM 53-05 FIG 4. (M)SDR AALA20001369Cargo Track · corrodedTUL - FOUND CARGO TIE DOWN TRACK CORRODED TOP SIDE STATION 1211 TO STATION 1287. REPAIRED CARGO TIE DOWN TRACK WITH NEW TIE DOWN TRACK STATION 1212-1338 PER 51-01. (M)SDR TWAA0013306Computer · failedON DEPARTURE, NUMBER 1 AND 2 COMPASSES DIFFERED BY AT LEAST 45 DEGRESS. MAG COMPASS DIFFERED BY AT LEAST 40 DEGREES FROM KNOWN HEADING. MADE UNSCHEDULED LANDING AT JFK. REPLACED THE NUMBER 1 AHRS COMPUTER (P/N 460800-03-06M0D4), AND THE MAGNETIC COMPASS (P/SDR TWAA0013101Light · arcedTHE OVERHEAD LIGHT CABIN ROW 27 RT SIDE WAS ARCING AND HAD AN ODOR. CREW REMOVED THE BULB. MAINTENANCE REMOVED THE CONNECTOR FROM THE LIGHT BALLAST AND DEFERRED CORRECTIONS PER MEL. NO CHECK-C. *S/D* FOUND LAMPHOLDERS HAD BURNED CONTACTS CAUSED BY LAMP NOSDR ASAA0080511Bottle · dischargedSEA - PRIOR TO FLIGHT 752, THE L2 DOOR EMERGENCY EVACUATION SLIDE PRESSURE WAS FOUND TO BE LOW. REPLACED THE L2 DOOR SLIDE AND ROUTED TO SEA FOR INSPECTION AND/OR REPAIR. THE SLIDE WAS INSPECTED AND THE BOTTLE WAS REPLACED. THE BOTTLE WAS ROUTED TO AIR CRUISSDR TWAA0013002Light · inoperativeTHE FLIGHT DECK AND FWD GALLEY EMERGENCY LIGHTS, EGRESS LIGHT AT ROW 28D, AND THE OVERHEAD EMERGENCY LIGHTS IN THE AFT GALLEY WERE INOPERATIVE. THE RED LENS FOR EGRESS LIGHTS IN THE AFT CABIN WAS MISSING. REPLACED THE BATTERIES IN THE BATTERY PACK FOR THE FWSDR ASAA0080510Wire · disconnectedSEA - PRIOR TO FLIGHT 660, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED/ADJUSTED WIRING AND THE LIGHTS OPERATED NORMALLY. (M)SDR AALA20001358Connector · looseDFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT AT SIDE OF FORWARD GALLEY INOPERATIVE. RECONNECTED CONNECTOR. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20001357Wire · brokenORD - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT SEAT 5E INOPERATIVE. REPAIRED WIRE AT SEAT 5E. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR TWAA0012902Light · inoperativeTHE EMERGENCY LIGHT IN THE FIRST CLASS AND FWD GALLEY WERE INOPERATIVE. REPLACED THE WIRE JUMPER BETWEEN ROWS 2 AND 3. CHECK-C 10-2-99 STL.SDR AALA20001386Web · corrodedTUL - FOUND RIGHT CUSP STATION 1161-1166, HAS CORROSION AT RIVET TAILS NR 6 SEAT TRACK OUTBOARD FLANGE. REPAIRED PER AARD 53-00-00-02. INSTALLED DOUBLER. (M)SDR ASAA0080508Battery · dischargedSEA - PRIOR TO FLIGHT 445 - THE FLIGHT STATION EMERGENCY EXIT LIGHTS WERE FOUND TO BE INOPERATIVE. REPLACED BATTERY AND LIGHTS OPERATE NORMALLY. (M)SDR ASAA0080509Latch · stuckSEA-PRIOR TO FLIGHT 608 THE L-1 DOOR HOLD OPEN LATCH WAS FOUND TO BE STUCK. REPLACED HOOK RELEASE CRANK AND DOOR OPERATED NORMALLY.SDR AALA20001370Seat Track · corrodedTUL - FOUND CORROSION ON NR 3 SEAT TRACK. REPAIRED SEAT TRACK WITH PLUG REPAIR AARD 53-20-10. (M)SDR AALA20001381Web · corrodedTUL - FOUND RIGHT CUSP STATION 1184-1187 CORROSION AT RIVET UNDER NR 6 SEAT TRACK OUTBOARD FLANGE. RIGHT CUSP STATION 1193 CORROSION WHERE SEAT TRACK ATTACHES TO FLOOR. REPLACED PER SRM 53-01 FIG 4. REMOVED DAMAGED AREA INSTALLED NEW PIECE. (M)SDR AALA20001380Seat Track · corrodedTUL - FOUND CORROSION ON NR 3 SEAT TRACK. REPAIRED SEAT TRACK WITH PLUG REPAIR AARD 53-20-00-10. (M)SDR ASAA0080507Wire · disconnectedSEA - PRIOR TO FLIGHT 199, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE IN THE FIRST CLASS CABIN. RECONNECTED WIRING AND SECURED TRACK, LIGHTS OPERATED NORMALLY. (M)SDR AALA20001379Seat Track · corrodedTUL - FOUND CORROSION AND DAMAGE (GOUGE) ON NR 2 SEAT TRACK. REMOVED AND REPLACED SEAT TRACK FROM PROD BREAK TO END SRM 51-60. (M)SDR TWAA0012604Power Supply · inoperativeTHE LT AND RT FWD OVERWING EMERGENCY EXIT LIGHTS, AND THE EGRESS LIGHT AT ROW 7, WERE INOPERATIVE. REPLACED THE POWER SUPPLY (P/N 60-0304-51LB) FOR THE EXIT LIGHTS, AND THE LIGHT SOCKET (P/N 0105606-003) FOR THE EGRESS MALFUNCTION. CHECK-C 9-19-99 STL.SDR AALA20001377Seat Track · corrodedTUL - FOUND CORROSION AND WEAR ON NR 6 SEAT TRACK. CUT OUT DAMAGE AND CORROSION AND INSTALLED PLUG REPAIR PER AARD 53-20-00-10. (M)SDR AALA20001375Seat Track · corrodedTUL - FOUND CORROSION AND WEAR ON NR 6 SEAT TRACK. REMOVED CORROSION AND WEAR AND INSTALLED PLUG REPAIR PER AARD 53-20-00-10. (M)SDR AALA20001374Web · corrodedTUL - FOUND HOLE IN CUSP RIGHT SIDE UNDER NR 6 SEAT TRACK. CUT OUT CORROSION, FOUND AFTER CLEANING DAMAGE AND INSTALLED 7075 T6.040 DOUBLER PER AARD 53-00-00-02 AND SRM 53-01 FIG 4. (M)SDR TWAA0012603A/C Pack · malfunctionedSMOKE APPEARED IN THE COCKPIT AND CABIN. MADE AN UNSCHEDULED LANDING AT BNA. REPLACED THE WATER COALESCER FILTERS AND ACCOMPLISHED A PACK BURN OUT TO REMOVE TRACES OF THE SMOKE. DETERMINED THE PROBLEM TO BE IN THE RT AIR CONDITIONING SYSTEM. CORRECTION TO SDR ASAA0080503Harness · disconnectedSEA - PRIOR TO FLIGHT 660, THE FORWARD 7 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING HARNESS AT ROW 3 AND THE EMERGENCY EXIT LIGHTS OPERATED NORMALLY. (M)
Back to Boeing DC-9-83