Boeing DHC-8-102
Service difficulty reports · 9,272
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA131008004Actuator · cracked(CAN) DURING TRANSIT CHECK, HYDRAULIC LEAK FOUND DRIPPING FROM LT WING INBD AND OTBD CANOE FAIRINGS. LEAK WAS TRACED TO THE RT OTBD SPOILER ACTUATOR FROM THE PISTON SEAL. ACTUATOR WAS REPLACED AND SYSTEM BLED IAW AMM 27-14-05 AND 27-14-00. LEAK CHECKS WERE CSDR HNAA2013100400525Bulb · failedCEILING EMERGENCY LIGHT SIGN IS DIM AT ROW 4. R & R BULBS IN CEILING EMERGENCY LIGHT PANEL AT ROW 4 IAW MM 33-51-00. OPS CHECKED GOOD.SDR HNAA2013100400524Bulb · failedCEILING EMERGENCY LIGHT SIGN IS DIM AT ROW 1. R & R BULBS IN CEILING EMERGENCY LIGHT SIGN IAW MM 33-51-00. OPS CHECKED GOOD.SDR CA131004005Check Valve · fractured(CAN) SHORTLY AFTER TAKEOFF, FLIGHT CREW RECEIVED A NR 2 HYD ISO VALVE CAUTION MESSAGE AND NOTICED THAT THE HYDRAULIC NR 2 SYSTEM FLUID LEVEL HAD DEPLETED TO 0.5. INBOUND OF THE DESTINATION AIRPORT AN EMERGENCY WAS DECLARED AND AN ALTERNATE LANDING GEAR EXTENSSDR CA131002002Actuator · fractured(CAN) TAXING FOR TAKEOFF AND WHILE PERFORMING FLIGHT CONTROL CHECKS, FLIGHT CREW NOTICED THAT THEY HAD LOST THE NR 1 HYD SYS. ACFT TAXIED BACK TO THE GATE WHERE A HYDRAULIC LEAK WAS NOTICED UNDER THE RT WING. A MAINTENANCE TEAM TRAVELED TO THE OUTSTATION ANDSDR CA131001004Line · chafed(CAN) DURING ROUTINE MAINTENANCE A FUEL LEAK WAS NOTED AT THE NACELLE DRAIN LINE. INVESTIGATION FOUND THE FUEL LINE AND MOTIVE FLOW LINE CHAFFING AT THE SPLIT WASHERS WITHIN THE SHROUD IN THE DRY BAY. THE 2 FUEL LINES AND ASSOCIATED HARDWARE WERE REPLACED. FSDR CA130927007Fitting · corroded(CAN) WHILE PERFORMING MAINTENANCE RELATED TO SB8-54-41, MODERATE CORROSION WAS WITNESSED IN THE BORE OF THE OTBD NACELLE TO REAR SPAR FITTING BETWEEN THE 2 HAT BUSHINGS. THE FITTING WAS REPLACED IAW THE APPROVED AMM/SRM REFERENCES. AC CYCLES: 63590, AC HOURSSDR HNAA2013092700519Warning Light · false activationBOTH ENGINES MANUAL CAUTION LIGHTS ILLUMINATED IN FLIGHT. NO ENGINE ROLL BACK MODE SWITCH LIGHTS REMAINED ON. INSPECTED ENGINE CONDITION PANEL. NO DEFECTS NOTED. CYCLED BETA LOCKOUT CIRCUIT BREAKER IN DC CONTACTOR BOX. CREW GROUND RAN ACFT. TESTING BOTH ECU'SDR HNAA2013092700518Relay · malfunctionedREJECTED TAKEOFF DUE TO AUTO FEATHER FAILURE TO ARM. GROUND RAN ACFT, COULD NOT DUPLICATE. R & R ARM CONTROL RELAY 6121-K5 FOR POSITIVE MX ACTION. OPS CHECKED GOOD AT THIS TIME.SDR CA130927002Actuator · fractured(CAN) THE FLIGHT CREW REJECTED TAKEOFF AT 30 KNOTS WHEN THEY LOST NR 1 HYDRAULIC SYSTEM PRESSURE, THE RUD ISO CAUTION LIGHT ALSO ILLUMINATED. THE NR 1 HYDRAULIC RESERVOIR QTY WAS NEAR ZERO. MAINTENANCE INVESTIGATION FOUND THE RT INBD ROLL SPOILER ACTUATOR HOSDR CA130923004Fitting · corroded(CAN) NR 1 NACELLE TO REAR SPAR, OTBD ATTACHMENT FITTING REMOVED DUE TO LEVEL 3 CORROSION. REPLACED WITH SERVICEABLE PART IAW APPROVED REF.SDR CA130923002Strut · corroded(CAN) NR 2 ENGINE, OTBD LOWER ENGINE SUPPORT STRUT HAS CORROSION AND PITTING IN THE BORE AT THE LOWER ATTACHMENT POINT. STRUT REPLACED IAW AMM.SDR HNAA2013092300510Bulb · failedSIDEWALL EMERGENCY LIGHT IS DIM AT ROW 4DF. R & R BULB AT SIDEWALL EMERGENCY LIGHT IN ROW 4DF. OPS CHECKED GOOD.SDR HNAA2013092300509Bulb · inoperativeRED FLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 6DF. R & R BULB AT ROW 6DF FLOOR PATH EMERGENCY LIGHT. OPS CHECKED GOOD.SDR HNAA2013092300508Bulb · failedFWD FUSELAGE RT EMERGENCY LIGHT IS DIM. R & R BULB AT RT FWD EMERGENCY LIGHT FUSELAGE. OPS CHECKED GOOD.SDR HNAA2013092300506Bulb · inoperativeNORMAL GREEN LIGHT ON EMERGENCY LIGHT BUTTON FOR F/A PANEL IS INOPERATIVE. R & R EMERGENCY LIGHT BULB ON F/A PANEL IAW AMM 33-51-02. OPS CHECKED GOOD.SDR CA130923013Bracket · cracked(CAN) FLIGHT CREW REPORTED THAT THE MLG ALTERNATE EXTENSION HANDLE DID NOT RETRACT AFTER BEING PULLED. MAINTENANCE TROUBLESHOOTING REVEALED THAT THE LT ALTERNATE EXTENSION CABLE NACELLE TOP BRACKET ASSY WAS CRACKED AND THE CABLE OFFS THE PULLEY. FURTHER TROUBSDR CA130923010Pulley · seized(CAN) FLIGHT CREW REPORTED THAT THE MLG ALTERNATE EXTENSION HANDLE WAS VERY HARD TO OPERATE AT THE SECOND DETENT. MAINTENANCE TROUBLESHOOTING REVEALED THAT THE INBD FWD NACELLE PULLEY WAS SEIZED, REFER TO ATTACHED ILLUSTRATED PARTS CATALOG FIGURES FOR DETAILSSDR CA130920005Actuator · leaking(CAN) AN ACFT HAD A HYDRAULIC FLUID LOSS WHILE TAXIING OUT FROM AIRPORT. THE CREW REPORTED IT WAS THROUGH LT OTBD SPOILER ACTUATOR. ACFT RTS- SPOILER ACTUATOR REPLACED.SDR CA130920003Battery · overheated(CAN) THE AUX BATTERY HOT WARNING LIGHT CAME ON IN FLIGHT. IAW THE QRH THE CREW SELECTED THE BATTERY OFF. THE BATTERY TEMPERATURE CONTINUED TO RISE SO THE FLIGHT DIVERTED TO THE NEAREST SUITABLE AIRPORT. THE AUX BATTERY WAS REPLACED AND THE ACFT RETURNED TOSDR HNAA2013092000505Bulb · dimCABIN, EMERGENCY EXIT SIGN ON CENTER AISLE AT ROW 1 IS DIM. R & R EMERGENCY LIGHT THAT WERE DIM AT CENTER AISLE AT ROW 1. OPS CHECKED GOOD REINSTALLED COVER.SDR HNAA2013092000504Wire · damaged-ESCAPE PATH EMERGENCY LIGHT BULB IS INOPERATIVE AT ROW 8 . R & R LIGHT, AISLE MARKER DUE TO BAD WIRE CONNECTION.SDR HNAA2013092000503Bulb · dimCABIN, CEILING EXIT SIGN AT CENTER ISLE OF ROW 1 IS DIM, R & R DIM LIGHTS OF CEILING EXIT SIGN AT CENTER ISLE OF ROW 1 OPS CHECKED GOOD, REINSTALLED CEILING COVER.SDR CA130917002Relay · malfunctioned(CAN) DURING CLIMBOUT, WITH LANDING GEAR LEVER SELECTED "UP", THE GEAR DOORS OPENED AND GEARS RETRACTED, BUT ALL GEAR DOORS REMAINED OPEN AND THE "LDG GEAR INOPERATIVE" CAUTION ILLUMINATED. THE 3 AMBER "DOOR" ANNUNCIATORS ON THE LANDING GEAR SELECTOR PANEL ALSDR HNAA2013091700496Battery · inoperativeEMERGENCY LIGHT OUT. R & R EMERGENCY LIGHTS BATTERY AT 3352-PS 2 ROW 1DF IAW AMM 33-51-00.SDR HNAA2013091700497Brake Assy · smokeNR 2 BRAKE SMOKED DURING TAXI IN. R & R NR 2 BRAKE ASSY IAW W/C 32-10-03I AND 32-41-11X.SDR HNAA2013091700499Indicator · inaccurateFLAP POSITION INDICATOR READS 2.5 DEG W/ FLAP SELECTED TO ZERO. R & R FLAP POSITION INDICATOR IAW -8MM, 27-53-05. OPS CK GOOD.SDR HNAA2013091700498Bulb · inoperativeSIDEWALL EMERGENCY EXIT SIGN DIM AT 4AC & BY PAX DOOR. R & R BURNED BULBS IN SIDEWALL EMERGENCY EXIT SIGNS AT 4AC & BY PAX DOOR.SDR HNAA2013091200495Bulb · failedEMERGENCY SIDEWALL LIGHT IS INOPERATIVE AT ROW 4DF. R & R BULB AT ROW 4DF. OPS CHECKED GOOD.SDR HNAA2013091200494Bulb · failedEMERGENCY LIGHT AT ROW 1 IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.SDR HNAA2013091200493Starter Gen · failedNR 1 DC GENERATOR FAILED ON TAKEOFF. REMOVED NR 1 DC START GENERATOR IAW WC 24-30-02R AND R & R NR 1 DC GCU IAW MM 24-31-03. OPS AND LEAKED CHECKED GOOD.SDR CA130911008Pulley · seized(CAN) PULLEY IN THE RT AILERON CABLE FOUND SEIZED DURING INSPECTION. PULLEY REPLACED IAW THE AMM.SDR HNAA2013091000492Selector Panel · malfunctionedAT APPROX. 300 FT. ALL GEAR SHOWED RED UNSAFE, WARNING HORN SOUNDED AND CREW FELT NLG CLUNKING FOR APPROX 1 MINUTE. R & R LANDING GEAR SELECTOR PANEL IAW AMM 32-30-05. R & R LANDING GEAR SELECTOR VALVE IAW WC 32-30-41R. OPS AND LEAKED CHECKED GOOD AT THIS TSDR HNAA2013091000491Ground Wire · brokenAFTER TAKEOFF, ON GEAR RETRACTION, ALL GEAR REMAINED DOWN. ALL THREE GREEN, RED AND HANDLE LIGHTS REMAINED ILLUMINATED IAW CHECKLIST, SELECTED GEAR DOWN THEN HAD 3 GREEN AND 3 AMBER, GEAR DOORS INDICATED CLOSED 5 MINUTES LATER. JACKED ACFT, CYCLED GEAR SEVERSDR HNAA2013091000490Warning Light · malfunctionedWHEN GEAR SELECTED UP, THE THREE GREEN LIGHTS STAYED ON AND THE THREE RED UNSAFE LIGHTS ILLUMINATED. AFTER APPROX 90 SECONDS, GEAR RETRACTED AND LIGHTS WENT OUT. OPS NORMAL AFTER THAT. SWUNG GEAR, OPS CHECKED GOOD IAW MM 32-30-05. NO DEFECTS NOTED. R & R GSDR CA130906002Cable · frayed(CAN) CREW REPORTED A SNAP WHILE APPLYING PARK BRAKE. LT BRAKE PEDAL HAS 4-5" OF PLAY. MAINTENANCE DISCOVERED A BROKEN BRAKE CABLE AND BENT BRAKE CONTROL ROD. CAPT`S LT BRAKE CABLE, PN 83200501-001. REPLACED AS WELL AS CAPT`S LT BRAKE CONTROL ROD, PN 8271002SDR HNAA2013090300487Sensor · out of adjustFLAP DRIVE CAUTION LIGHT FLICKERED ON AND OFF IN FLIGHT AND ON GROUND. R & R FLAP DRIVE TORQUE SENSOR IAW MM 27-52-51. ADJUSTED SENSOR IAW WC 27-50-11Q. INSPECTED FLAP DRIVE TORQUE TUBES, NO DEFECTS NOTED. OPS CHECKED GOOD.SDR CA130903004Actuator · fractured(CAN) DURING MAINTENANCE, IT WAS NOTICED THAT THE LT OTBD ROLL SPOILER ACTUATOR WAS BADLY LEAKING. FURTHER INVESTIGATION REVEALED THE ACTUATOR CASING WAS FRACTURED. THE ACTUATOR WAS REPLACED, TESTED AND THE ACFT RELEASED FOR SERVICE.SDR CA130911015Pump · leaking(CAN) THE PILOT REPORTED THAT THE NR 2 ENGINE LOW OIL PRESSURE CAUTION LIGHT COMES ON PASSING 600 FT RIGHT AFTER TAKEOFF. THE OIL PRESSURE WAS FLUCTUATED IN BETWEEN 20-25 PSI, THE ENGINE WAS MANUALLY SHUTDOWN. THE AIRCRAFT CONTINUED TO FLY ABOUT 30 MIN. AND SDR CA130903008Valve · fractured(CAN) AFTER LANDING, THE PILOT REPORTED BOTH HYDRAULIC SYSTEMS NEEDED TOP UP. MAINTENANCE INVESTIGATION FOUND A HYDRAULIC LEAK IN THE LT NACELLE. THE LEAK WAS TRACED TO THE FORWARD HYDRAULIC QTY LIMITING VALVE, HYDRAULIC FUSE, WHICH WAS FOUND WITH THE END CAPSDR HNAA2013083000484Transmitter · damagedON TAKEOFF ROLL, RT SPOILER INDICATED DEPLOYED AND AGAIN IN TAXI MODE. INSPECTED RT INBD ROLL SPOILER, FOUND SYNCRO TRANSMITTER ARM OVER CENTER. REPOSITIONED TO CORRECT POSITION. GROUND RAN ACFT, OPS CHECKED SPOILERS. OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR HNAA2013083000482Bulb · malfunctionedLT FUSELAGE AFT EXTERIOR EMERGENCY LIGHT IS DIM. R & R BULB. OPS CHECKED GOOD.SDR HNAA2013082800481Duct · dirtyLIGHT ODOR NOTICED WITH ENGINE BLEEDS SELECTED ON. REMOVED ALL DUCTS FROM HEAT EXCHANGER, ACM AND CONDENSOR MIXER, CLEANED DUCTS. REINSTALLED ALL DUCTS AND SAFTIED WIGGENS FITTING. NO ODOR NOTED.SDR HNAA2013082800480Bulb · failedEMERGENCY LIGHT IS INOPERATIVE AT ROW 7. R & R BULB. OPS CHECKED GOOD.SDR HNAA2013082800479Bulb · failedCEILING ESCAPE PATH EMERGENCY LIGHT IS INOPERATIVE AT ROW 5DF. R & R BULB IAW AMM 33-51-00. OPS CHECKED GOOD.SDR HNAA2013082600476Acm · odorDURING PUSH BACK, HEARD GRINDING NOISE ASSOCIATED WITH ODOR. SELECTED APU BLEED OFF, WHICH ELIMINATED NOISE AND ODOR. INSPECTED AND FOUND ACM SEIZED. R & R ACM IAW WC 21-50-03, STEPS 13 AND 25. OPS CHECKED GOOD. NO NOISE OR ODOR NOTICED.SDR HNAA2013082600475Unknown · odorELECTRICAL BURNING ODOR APPEARS TO BE COMING FROM OVERHEAD LIGHTS AT ROW 7DF. R & R LAMP HOLDER, BULB AND BALLAST. OPS CHECKED GOOD.SDR CA130826009Sequence Valve · failed(CAN) AFTER TAKEOFF, THE NR 2 HYDRAULIC SYSTEM QUANTITY DROPPED TO 2 QUARTS AND THEY RECEIVED A RUDDER ISO CAUTION LIGHT. THE ACFT RETURNED TO THE DEPARTURE AIRPORT WITHOUT INCIDENT. MAINTENANCE INVESTIGATION FOUND THE RT MLG DOOR SEQUENCE VALVE FAILED WHICHSDR CA130918002Oil System · low pressure(CAN) AIRCRAFT REPORTED AN IFSD ON THE NR 2 ENGINE ON THE 21ST AUGUST DUE TO LOW OIL PRESSURE IAW THE REPORT FROM THE CREW. THE ACFT WAS ENROUTE BUT HAD TO RETURN TO BASE AFTER THE ENGINE SHUTDOWN. POST MAINTENANCE INSPECTIONS AND CHECKS ON THE ENGINE FOUND SDR HNAA2013082200471Socket · overheatedHOT ELECTRICAL ODOR OVER ROW 4. INSPECTED AND FOUND OVERHEAD LIGHT 3DF OVERHEATING AT SOCKET AND BASE. REMOVED BULB, PULLED AND COLLARED CIRCUIT BREAKERS S1, S2 AND R2. CABIN INTERIOR NORMAL LIGHTING SYS, R & R SOCKET AT LAMP ASSY ON ROW 3DF. OPS CHECKED G
Back to Boeing DHC-8-102