Boeing DHC-8-102
Service difficulty reports · 9,272
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2008110300319Brake · smokeTHE NR 1 BRAKE ASSEMBLY APPEARED TO BE SMOKING DURING TAXI. MAINTENANCE JACKED THE AIRCRAFT AND INSPECTED THE BRAKE ASSEMBLY. THE BRAKE WAS COLD TO THE TOUCH AND WEAR PINS INDICATED A NEWER BRAKE ASSEMBLY. THE BRAKE ASSEMBLY WAS CHANGED AS A PRECAUTION. LESDR CA081110001Battery · incorrect(CAN) WRONG BATTERY INSTALLED IN UNIT. CORRECT BATTERY INSTALLED INTO ULB. REF WO NR 214939SDR HNAA20080300318Indicator · defectiveTAKEOFF WAS ABORTED WHEN THE TAKEOFF WARNING HORN SOUNDED. MAINTENANCE CYCLED THE CONDITION LEVER AND SYSTEM OPERATED NORMALLY. THE FLAP POSITION INDICATOR WAS CHANGED OUT AND SYSTEM CHECK WAS PERFORMED. NO DEFECTS WERE NOTED AT THAT TIME AND AIRCRAFT WAS TSDR HNA2008F00057Doubler · crackedUPON GEAR EXTENSION DURING FINAL APPROACH TO RUNWAY 35, THE NOSE GEAR RED UNSAFE LIGHT INDICATION ILLUMINATED. BOTH MAIN GEARS LOCKED AND ILLUMINATED GREEN INDICATIONS. THE CREW DISCONTINUED THE APPROACH AND PERFORMED THE ALTERNATE GEAR EXTENSION PROCEDURE. SDR HNAA2008102900320Doubler · crackedUPON GEAR EXTENSION DURING FINAL APPROACH TO RUNWAY 35, NOSE GEAR RED UNSAFE LIGHT INDICATION ILLUMINATED. BOTH MAIN GEARS LOCKED AND ILLUMINATED GREEN INDICATIONS. CREW DISCONTINUED APPROACH AND PERFORMED ALTERNATE GEAR EXTENSION PROCEDURED. GEAR WAS NOT CYSDR HNAA0800309Connector · shortedDURING DESCENT A BURNING ODOR WAS DETECTED IN THE COCKPIT. UPON INVESTIGATION, THE L1 CONNECTOR ON THE CO-PILOTS WINDSHIELD WAS FOUND TO BE BURNT. THE WINDSHIELD WAS REMOVED AND REPLACED AND OPS CHECKED GOOD. AIRCRAFT WAS THEN RELEASED FOR SERVICE.SDR CA081023001Bearing · seized(CAN) DURING FLAP INSP, AN ENGINEER FOUND AN AILERON PULLEY INSIDE THE WING BOX SEIZED. FURTHER INVESTIGATION REVEALED THE ADJACENT PULLEY WAS ALSO CORRODED. BOTH PULLEYS WERE REPLACED AND THE ACFT RETURNED TO SERVICE. 1915 HRS WERE REMAINING BEFORE COMPLETISDR HNAA0800310Bleed Air Sys · contaminatedAN ODOR WAS DETECTED WHEN THE BLEED SYSTEM DUCT TEMP EXCEEDS 20C. THE APU AND ENGINE BLEEDS WERE RUN ON THE GROUND AND ODOR DISSIPATED. SUSPECT RESIDUAL DE-ICE FLUID CONTAMINATION OF APU DURING MORNING DE-ICEING OF AIRCRAFT. AIRCRAFT WAS RELEASED FOR SERVICSDR HNAA0800311Indicator · malfunctionedDURING TAKEOFF ROLL, POWERED FLIGHT CONTROL SYSTEM INDICATOR SHOWED THE LEFT WING SPOILERS NOT RETRACTED. TAKEOFF WAS ABORTED BELOW 30 KTS. MAINTENANCE CHANGED THE PFCS INDICATOR. OPS CHECKS WERE GOOD AND AIRCRAFT WAS THEN RELEASED BACK INTO SERVICE.SDR HNAA0800312Indicator · failedDURING THE TAKEOFF ROLL, THE NR 2 HYDRAULIC SYSTEM INDICATOR WENT TO ZERO. CAUTION LIGHT DID NOT ILLUMINATE AND QUANTITY REMAINED STEADY. TAKEOFF WAS ABORTED AT 75 KNOTS IAS. MAINTENANCE REPLACED THE HYDRAULIC PRESSURE INDICATOR. OPS CHECKS WERE GOOD AND TSDR HNAA2008102000316Module · brokenTHE 5TH FROM FWD-AFT FLOOR AISLE EMERGENCY LIGHT INOP. REMOVED AND REPLACED FLOOR AISLE EMERGENCY LIGHT MODULE. OPS CHECK GOOD.SDR HNAA2008102900321Actuator · bypassingFLIGHT 4165 LGA TO ROA. THE GEAR WAS SELECTED DOWN ON APPROACH. THE MAIN GEAR INDICATION WAS NORMAL AND THE NOSE GEAR INDICATION WAS RED. THE ALTERNATE INDICATION WAS NOT INDICATING AND THE APPROACH WAS MISSED. THE GEAR WAS THEN CYCLED FOR A SECOND TIME ANSDR HNAA20081016Skin · damagedRT INBOARD END CAP MISSING PART OF BOTTOM SKIN. FERRY FLIGHT 9310 FROM FLO TO SBY. REMOVED RT INBOARD END CAP AND TWO ASSOCIATED RIBS. INSTALLED TWO NEW RIBS AND NEW END CAP PANEL IAW DRAWING 85520002.SDR HNAA2008110800317Doubler · corrodedDURING C-CHECK, THE LAVATORY SERVICE DOOR CUTOUT ON THE RIGHT SIDE OF THE FUSELAGE BELOW AND FORWARD OF THE RIGHT SIDE EMERGENCY EXIT WAS FOUND TO HAVE CORROSION ON THE SKIN DOUBLER. THE CORROSION WAS LOCATED ON THE AFT CORNER, BOTTOM EDGE OF THE LAVATORY SERSDR HNAA2008101700314B-Nut · looseAIRCRAFT EN ROUTE FROM LGA TO ROA, THEN DIVERTED INTO LYH DUE TO WEATHER. IN LYH CREW FOUND FLUID DRIPPING FROM NR 2 NACELLE. MAINT CLEANED SUSPECTED AREA, GROUND RAN AIRCRAFT OPERATED FLAPS, SPOILERS, AND BRAKES. NO LEAKS NOTED AT THIS TIME. 10/10/2008 AISDR CA081008007Panel · misaligned(CAN) FLEX IN LAV WALL IS CAUSING SIGNIFICANT IN-SERVICE MISALIGNMENT OF PONS INSTALLED IN LATCH HOUSING USING TTF-SB-03T002-001. REFER TO PROTECTED "A" AD CF-2008-26R1 AND STC SA03-70, SB TTF-SB-03T002-001 REV "D".SDR HNAA2008101600312Pseu · faultedUPON TAKEOFF LANDING GEAR WARNING HORN SOUNDED FOLLOWED BY THREE RED LANDING GEAR UNSAFE LIGHTS. ABORTED TAKEOFF, PERFORMED PSEU BITE TEST, PSEU MEMORY RECALL CODES 45 AND 54 WERE RETRIVED.(45 "NOSE WHEEL STEERING" AND 54 "PSEU DRIVER CARD 1A"). REMOVED AND SDR HNAA2008101600309Collar · debondedMINOR PROP VIBRATION NR 1 PROP FELT ON TAXI OUT. CLT MAINT INSPECTED FOUND A BLADE COLLAR DISBONDED. REMOVED BLADE COLLAR HALF PER HAM STAND 61-10-00 DNAA ITEM PLACED ON 10 FLIGHT HOUR DMT FOR BLADE REMOVAL AND REPLACEMENT. ROA MAINT REMOVED AND REPLACED NRSDR CA081006003Control Rod · broken(CAN) ON CLIMB OUT, THE CREW NOTED A VIBRATION AND BANGING NOISE FROM THE NOSE OF THE ACFT. THE ACFT RETURNED AND THE GROUND CREW NOTED THAT THE RT NLG DOOR WAS OPEN AND THAT THE DOOR CONTROL ROD AND TENSION SPRING (PN 83232010-105) FOR THE RT DOOR WAS BROKENSDR HNAA2009010900384Seat Track · corrodedDURING C-CHECK, SEVERAL AREAS OF CORROSION WERE FOUND ON THE LT OTBD SEAT RAIL. THE SEAT RAIL WAS R&R.SDR HNAA0800287Wire · brokenEMERGENCY LIGHT AT ROW 1F IS INOP. REPAIRED BROKEN WIRES AT RT FWD EMERGENCY DOOR LIGHT. OPS CHECK GOOD. OK FOR SERVICE.SDR HNAA0800290Switch · brokenNR 2 BLEED HOT CAUTION LIGHT ILLUMINATED IN FLIGHT. R&R NR 2 ENGINE HIGH PRESSURE BLEED SWITCH. REFERENCE MM 21-11-21. GROUND RUN OPS CHECK GOOD.SDR HNAA0800289Pressure Switch · stuckNR2 ENGINE BLEED HOT CAUTION LIGHT ILLUMINATED DURING FLIGHT. LIGHT GOES OUT WHEN SWITCH SELECTED OFF, FERRYING TO SBY. R&R D BLEED OVERTEMP SWITCH IAW AMM 21-11-26 NO FIX. R&R D NR2 ENGINE HP BLEED VALVE. INSTALLING NEW USING RETAINED HARDWARE, AND REMOVESDR HNAA2009021200050Panel · corrodedDURING 'C' CHECK INSPECTIONS, THE LT WING STRESS PANEL, 522AT, WAS FOUND TO HAVE CORROSION IN SOME OF THE SCREW COUNTER SINKS THAT WAS BEYOND ACCEPTABLE LIMITS. THE PANEL WAS REPLACED. THIS IS AN AMENDMENT TO HNAA2009010900383 TO CORRECT ITEM 1C, REGISTRATIOSDR HNAA2009020100041Access Panel · corrodedRT WING ACCESS PANEL 622 AT (STRESS PANEL) HAS 2 HOLES CORRODED. CORROSION FOUND TO BE IN LIMIT PER RD8-57-1715. REPAIR HOLES IAW RD8-57-1715.SDR HNAA2009010900383Panel · corrodedDURING C-CHECK INSP, THE LT WING STRESS PANEL, 522AT, WAS FOUND TO HAVE CORROSION IN SOME OF THE SCREW COUNTER SINKS THAT WAS BEYOND ACCEPTABLE LIMITS. THE PANEL WAS REPLACED.SDR HNAA2009010900382Door Frame · corrodedDURING C-CHECK INSP, THE LAVATORY SERVICE DOOR FRAME WAS FOUND TO HAVE CORROSION ON IT. THE DOOR FRAME WAS REPLACED IAW SRM PROCEDURES. ADDITIONALLY, THE PAX DOOR THRESHOLD WAS FOUND TO BE CORRODED. THAT ITEM, P/N 85320686-101, WAS ALSO REPLACED.SDR HNAA2009012500022Seat Track · corrodedFORWARD LT INBD SEAT TRACK HAVE SURFACE CORROSION FROM STA X182 TO STA X424.124. FROM STA 182 TO STA 260 FOUND TO BE PREVIOUSLY BLENDED, R&R SEAT TRACK IAW RD8-53-1932. REMOVED CORROSION FROM STA 260 TO STA 424 IAW RD8-53-1339.SDR HNAA2009012500019Panel · corrodedSTRESS PANEL 623 AT, 522AT, 521AT, 523AT CORROSION FOUND COUNTER SINK HOLES. STRESS PANEL 623AT, 523AT CORROSION REMOVED AND RETREATED 622AT,522 AT OUT OFF LIMITS. R&R PANEL. 512 AT NEED BUSHING INSTALLATION.SDR HNAA2008101700315Repair · corrodedUNRECORDED AND CORRODED REPAIR FOUND ON LT FLOORBEAM AT STATIONS 270.5 AND 240.5. REMOVED UNRECORDED REPAIR AND REPLACED WITH A REPAIR APPROVED BY EO8-53-08-3278. BRACKETS FABRICATED IN HOUSE IAW DRAWING NUMBER 85320044 AND INSTALLED IAW SRM 51-40-00.SDR HNAA2009020100040Skin Panel · dentedPROTRUDING DENT ON LT FUSELAGE AT STATION X195 BETWEEN STRINGER 23P AND 24P. REPAIRED DAMAGED IAW RD8-53-2181.SDR HNAA0800281Windscreen · arcedEN ROUTE TO DESTINATION AT 16000 FEET THE FLIGHT CREW NOTED A PUFF OF SMOKE COMING FROM UNDERNEATH THE MASTER CAUTION PANEL. THE SMOKE DISSIPATED WITH NO OTHER SIGNS OF DIFFICULTY. THE CAPTAIN DECLARED AN EMERGENCY AND NOTIFIED THE PASSENGERS OF AN AVIONICS SDR HNAA0800280Warning System · malfunctionedDURING TAKEOFF ROLL THE NR 1 ENGINE MANUAL LIGHT ILLUMINATED. ACFT WAS RETURNED TO THE FIELD. MX CYCLED THE BETA LOGIC CIRCUIT BREAKER AND GROUND RAN THE ACFT. NO DEFECTS WERE NOTED AT THAT TIME. THE ENGINE CONDITION PANEL WAS ALSO CHECKED AND NO FLAGS WERSDR HNAA0800288Hydraulic Line · leakingNR2 HYDRAULIC SYSTEM DROPPED TO 1 QUART AFTER TAKE-OFF. RUDDER ISO KICKED IN, WITH NO LOSS OF PRESSURE. FOUND NLG UP LOCK HYDRAULIC LINE LEAKING. INSTALLED TEMP FLEX LINE, BLED AND SERVICED HYDRAULIC SYSTEM. LEAK CHECK GOOD ON GROUND. REMOVED FLEX LINE ANSDR HNAA0800286Stud · looseAT APPROX 16,000`, BURNING SMELL AND VISIBLE SMOKE COMING FROM RT SIDE OF MASTER CAUTION PANEL. CONTRACT MX FOUND WIRE AT L1 POSITION ON F/O`S WINDSCREEN BURNT. FOUND TERMINAL STUD LOOSE. DEACTIVATED W/S HEAT AND ISSUED MEL. ROA R&R F/O`S WINDSHIELD IAW WOSDR HNA2008F00056Beltframe · corrodedFWD EMERGENCY DOOR AREA, BELTFRAME AT STA X254 FOUND CORRODED AND SURFACE CORROSION ON DOOR SILL. AT STA X259 BLENDED BELTFRAME IAW SRM 53-00-16. CLEAT, THRESHOLD, STRAP AND BRACKET LOCALLY FABRICATED IAW DRAWINGS 8532075, 85320594, 85321705, 853206070.SDR HNA2008F00055Bracket · corrodedFWD EMERGENCY DOOR AREA, BELTFRAME AT STA X254 FOUND CORRODED AND SURFACE CORROSION ON DOOR SILL. AT STA X259 BLENDED BELTFRAME IAW SRM 53-00-16. CLEAT, THRESHOLD, STRAP AND BRACKET LOCALLY FABRICATED IAW DRAWINGS 8532075, 85320594, 85321705, 853206070.SDR HNA2008F00054Strap · corrodedFWD EMERGENCY DOOR AREA, BELTFRAME AT STA X254 FOUND CORRODED AND SURFACE CORROSION ON DOOR SILL. AT STA X259 BLENDED BELTFRAME IAW SRM 53-00-16. CLEAT, THRESHOLD, STRAP AND BRACKET LOCALLY FABRICATED IAW DRAWINGS 8532075, 85320594, 85321705, 853206070.SDR HNA2008F00053Threshold · corrodedFWD EMERGENCY DOOR AREA, BELTFRAME AT STA X254 FOUND CORRODED AND SURFACE CORROSION ON DOOR SILL. AT STA X259 BLENDED BELTFRAME IAW SRM 53-00-16. CLEAT, THRESHOLD, STRAP AND BRACKET LOCALLY FABRICATED IAW DRAWINGS 8532075, 85320594, 85321705, 853206070.SDR HNAA0800307Fitting · corrodedFWD EMERGENCY DOOR AREA, BELTFRAME AT STA X254 FOUND CORRODED AND SURFACE CORROSION ON DOOR SILL. AT STA X259 BLENDED BELTFRAME IAW SRM 53-00-16. CLEAT, THRESHOLD, STRAP AND BRACKET LOCALLY FABRICATED IAW DRAWINGS 8532075, 85320594, 85321705, 853206070.SDR HNAA0800306Skin · corrodedCORROSION FOUND ON BOTTOM SKIN OF COCKPIT STA X123, LT STRINGER 31. REPAIRED CORROSION ON BOTTOM SKIN IAW SRM 53-20-21.SDR HNAA2009012700031Floorbeam · corrodedDURING 'C' CHECK INSPECTIONS, AN UNRECORDED REPAIR AND CORROSION WAS DISCOVERED ON THE LT SIDE OF THE FLOOR BEAM LOCATED AT X270.5 AND Y9.25 UNDER THE SEAT RAIL. THE CORRODED FLOOR BEAM SECTION WAS REMOVED, REPAIR ANGLES AND A PACKER FABRICATED AND INSTALLED SDR CA080908004Actuator · bypassing(CAN) FLT CREW REPORTED RUDDER TRIM INDICATOR SHOWS 40% RT DEFLECTION TO CENTRE BALL ON HSI. MX REPLACED THE RUDDER TRIM ACTUATOR AND CHECKED SYSTEM SERVICEABLE. ON THE NEXT FLIGHT THE CREW REPORTED NO APPRECIABLE CHANGE AND THAT IT APPEARED THEY WERE CROSS COSDR HNA2008F00049Bulb · inoperativeMOST REAR OVERHEAD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK GOOD. (S)SDR HNA2008F00048Lamp · burned outEMERGENCY BUTTON ON FAS CONTROL PANEL NOT BACKLIT. REPORTED TO MAINTENANCE. RELAMPED FAS EMERGENCY BUTTON ON CONTROL PANEL. OK FOR SERVICE. (S)SDR HNA2008F00045Engine · malfunctionedFLIGHT 4376 - LYH - DURING CRUISE FLIGHT, WHILE REDUCING PROPELLER SPEED TOWARD 900 RPM, NR2 CONDITION LEVER WENT BELOW MIN POSITION RESULTING IN A LOSS OF POWER. WHEN TORQUE RETURNED TO 0, A SUCCESFUL AIR START WAS ACCOMPLISHED. REMOVED FOR AND SENT TO ROA SDR HNAA2009012500026Bracket · corrodedUPPER AFT ANGLE OF INSIDE AIRSTAIR DOOR FOUND CORRODED. R&R PAX DOOR AFT ANGLE AND SHIMS IAW 52-10-00.SDR CA080815002Battery · overheated(CAN) DURING CLIMB OUT FROM YWK, THE CREW RECEIVED A "MAIN BAT HOT" RED WARNING MSG ASSOCIATED WITH A HIGH TEMPERATURE ON THE BATTERY TEMPERATURE MONITOR. THE ACFT RETURNED AND LANDED WITHOUT FURTHER INCIDENT. MX CONFIRMED THE BATTERY SUFFERED FROM A THERMAL RSDR HNAA2009020100038Skin Panel · dentedPROTRUDING DENT FOUND AT STATION 183.350 BETWEEN 24P-25P. REPAIRED DAMAGE IAW RD8-53-2181.SDR HNAA2009012500021Seat Track · corrodedSEVERAL SPOT OF MINOR CORROSION FOUND ON RT INBD SEAT TRACK FROM STA X259 TO 597. R&R SEAT TRACK IAW STRUCTURAL REPAIR MANUAL 51-40-00.
Back to Boeing DHC-8-102