SDR HNAA2009010300367Light · intermittentEMERGENCY LIGHT FLICKER ON INTERMITENTLY ON GROUND. RAN ACFT OPERATED EMERGENCY LIGHTS ON/OFF WITH LIGHTS ARMED. DID NOT FLICKER, CANNOT DUPLICATE. NO HISTORY.SDR HNAA2009010300369Light · inoperativeAFT OVER HEAD EMERGENCY LIGHT INOPERATIVE. REMOVED CEILING PANEL BEFORE REMOVING BULB, REINSTALL NEW BULB AND CEILING PANEL. OPS CHECK GOODSDR CA090116008Engine · making metal(CAN) DURING CLIMB, THE CREW NOTED A RAPID INCREASE IN FUEL FLOW, FOLLOWED BY A RAPID RISE IN TEMPERATURE AND TORQUE ON THE LT ENGINE. THE ENGINE DID NOT RESPOND TO POWER LEVER MOVEMENTS AND AN UNCOMMANDED IFSD OCCURRED. A SINGLE ENGINE LANDING WAS MADE AT THSDR CA081231001Engine · overtorqued(CAN) DURING CLIMB THE CREW OBSERVED AN OVERTORQUE ON THE NR 1 ENGINE, THE POWER LEVER WAS REDUCED AND THE ENGINE STABILIZED AROUND 93 PERCENT OF TORQUE BEFORE RAISING AGAIN. DECISION WAS MADE TO PERFORM AN INFLIGHT SHUTDOWN. THE CREW DECLARED AN EMERGENCY,SDR HNAA2009010300368Light · inoperativeEMERGENCY FLOOR PATH LIGHT INOPERATIVE AT ROW 4 AFT. R&R EMERGENCY FLOOR PATH LIGHT AT ROW 4 AFT.SDR HNAA2009010300365Hydraulic Line · leakingAFTER ROTATION, SELECTED GEAR UP, NOSE GEAR CAME UP, NOSE DOORS STAYED OPEN, MAIN GEAR STAYED UNSAFE, GEAR CAME UP NORMALLY WITH 3 GREENS AFTER APPOX 10 SECONDS AND GRINDING SOUND QUIT. INSPECTED AND FOUND NOSE GEAR DOWN LINE LEAKING AT STA X107.00. REMOVED ANSDR HNAA2009010300364Light · inoperativeEMERGENCY LIGHT OFF CENTER LIGHT INOPERATIVE. DID NOT TEST. RELAMPED BULBS. OPS CHECK GOOD.SDR HNAA2008122700363Windscreen · crackedFIRST OFFICES FRONT WINDSCREEN CRACKED, ARCHING AT THE INNER HEATER ELEMENT. REMOVED AND REPLACED FIRST OFFICERS WINDSHIELD REF MM 56-10-11, OPS CHECK GOOD.SDR HNAA2008122300361Selector Valve · failedNOSE GEAR FAILED TO EXTEND BY NORMAL PROCEDURE, REQUIRED ALTERNATE EXTENSION. REMOVED AND REPLACED GEAR SELECTOR VALVE IN REFERENCE MAINTENANCE MANUAL 32-30-41. REMOVED AND REPLACED GEAR HANDLE SELECTOR VALVE IN ACCORDANCE WITH MAINTENANCE MANUAL 32-30-41. SDR HNAA2008122000352Gcu · odorELECTRICAL SMELL ABOUT CABIN CIRCUIT BRAKER PANEL. INSPECT CABIN CIRCUIT BRAKER PANEL NO DEFECT FOUND. FOUND NUMBER 1 GENERATOR CONTROL UNIT BURNED SMELL. REMOVED AND REPLACE GENERATOR CONTROL UNIT AND STARTER GENERATOR REFERENCE HA 300 SEQUENCE 5. REMOVED SDR HNAA2008121900353Switch · dirtyWHEN ADVANCING POWER LEVER FOR TAKEOFF AT APPROXIMATELY 30 PERCENT TORQUE NUMBER 2 PROPELLER FEATHERED. INSPECT ENGINE CONTROL PANEL NO FLAG NOTED. CLEANED POWER LEVER SWITCHES 6126-S6 THRU S 13. COMPLY WITH WORK CARD 61-20-03Q AND 61-20-04Q.SDR CA081222009Generator · malfunctioned(CAN) SHORTLY AFTER TAKE OFF, THE FLIGHT CREW RECEIVED "NR 1 AC GEN" AND "NR 2 AC GEN" CAUTION LIGHTS. SYSTEMS WERE RESET AND NR 2 AC GENERATOR RETURNED ON LINE. DECISION WAS MADE TO RETURN AND THE AIRCRAFT LANDED WITHOUT FURTHER INCIDENT. THE NR 1 AC GENERSDR HNAA200082300360Control Box · faultyFLOOR EMERGENCY LIGHT INITIALLY ILLUMINATED WHILE ENGINES ARE RUNNING. GROUND RAN AIRCRAFT, CANNOT DUPLICATE, REMOVED AND REPLACED EMERGENCY LIGHT CONTROL BOX, OPS CHECK GOOD IAW 33-52-00.SDR HNAA2008122200358Regulator · failedRUDDER PRESSURE AND RUDDER FULL PRESSURE CAUTION LIGHT'S ILLUMINATED AFTER TAKEOFF. QUANTITY’S AND PRESSURE WERE NORMAL. RUDDER PRESSURE WENT OUT BELOW 140 KNOTS, RUDDER FULL PRESSURE WENT OUT AT 120 KNOTS. REMOVED AND REPLACED RUDDER DUAL PRESSURE REGULATOSDR HNAA2008122200356Brake · smokeLEFT MAIN BRAKE ASSEMBLY WET, SMOKES AFTER LANDING. REMOVED AND REPLACED NUMBER ONE BRAKE ASSY IN ACCORDANCE WITH 32-42-11, LEAK AND OPS GOOD.SDR CA081219005Latch · out of position(CAN) ROLL SPOILERS INBD AND OTBD UNSERVICEABLE IN FLIGHT. TROUBLESHOOTING FOUND ROLL SPOILER DISCONNECT SENSOR LATCHED. ROLL SPOILERS DISCONNECT SENSOR ASSEMBLY UNLATCHED. OPS TEST OF THE ROLL SPOILER CONTROL SYSTEM SERVICEABLE IAW AMM 27-14-00 PG. 204-205SDR HNAA2008122200359Receiver · failedNUMBER ONE NAVIGATION RADIO FAILED IN FLIGHT, CONTROL HEAD DISPLAY WENT BLANK AND NAVIGATION FLAG SHOWING. REMOVED AND REPLACED NUMBER 1 NAVIGATION RECEIVER, CHECKED WITH TIC BOX, OPS CK'D GOOD IN ACCORDANCE WITH 34-55-00.SDR HNAA2008122200355Control Unit · malfunctionedNR 2 ELECTRONIC CONTROL UNIT FAILED IN FLIGHT. RESET NR 2 ELECTRONIC CONTROL UNIT & BETA LOCKOUT CIRCUIT BREAKERS GROUND RUN AIRCRAFT, OPS CHECK GOOD OK FOR SERVICE.SDR HNAA2008122200354Coffeemaker · smokeHOT ODOR COMING FROM NUMBER ONE HOT JUG AREA. PERFORMED HIDDEN DAMAGE INSPECTION ON NUMBER ONE HOT JUG SOCKET (IN ACCORDANCE WITH SPECIAL PROCEDURE 33.1) NO DAMAGE NOTED. PULLED AND COLLARED NUMBER ONE HOT JUG CIRCUIT BREAKER. ITEM ON MEL 25-7, SEE SEQUENCE SDR HNAA2008121000345Battery Pack · dischargedLEFT AFT EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT ROW 3AC LOCATION IN ACCORDANCE WITH 33-51-00.SDR HNAA2008121000348Psu · smokePSU AT ROW 4 DF SMOKED. PERFORM HIDDEN DAMAGE INSPECTION, DEACTIVATED UNIT PER SP 23.3SDR HNAA2008121000349Smoke Detector · malfunctionedLAV SMOKE DETECTOR ALARM SOUNDS WITH NO EVIDENCE. TURNED APU BLEED ON, RAN ENGINE WITH BLEED SELECTED ON, LAV SMOKE DETECTOR DOES NOT SOUND, NO EVIDENCE OF SMOKE AND FUMES.SDR HNAA2008121000347Light · inoperativeTHE 2ND CEILING EMERGENCY LIGHT INOP. RELAMP 2ND CEILING EMERGENCY LIGHT BULB.SDR HNAA2008121000346Light · inoperativeFIRST FLOOR EMERGENCY LIGHT INOP. RELAMPED 1ST EMERGENCY LIGHT BULB.SDR HNAA2008121000350Generator · malfunctionedNR 2 DC GENERATOR WOULDN'T COME ON LINE, NR 2 DC GENERATOR HOT CAUTION LIGHT ILLUMINATED AND SMOKE AND SPARKS CAME FROM NR 2 ENGINE. REMOVED AND REPLACED RELAY 3421K2, REMOVED AND REPLACED NR 2 DC GCU AND STARTER GENERATOR IAW 24-30-02R, OPS GOOD PERFORMED HISDR HNAA2008121000344Torque Sensor · contaminatedON TAKEOFF NR 1 ENGINE TORQUE DROP TP 40 PERCENT IN FLUX THE INCREASED OVER 108 PERCENT FOR 15 SECOND PROPELLER RPM DROP TO 350. REMOVED TORQUE SENSOR CONTROL UNIT NR 1 ENGINE. FOUND MOISTURE IN CONNECTOR. REPLACED TORQUE SENSOR CONTROL UNIT.SDR HNAA2008121000343Light · defectiveDURING ROM MAINTENANCE, THE LEFT FORWARD EMERGENCY EGRESS LIGHT WAS FOUND TO BE DIM. THE BULB WAS REPLACED AND LIGHTING, OPS CHECKED GOOD.SDR HNAA2008121000342Light · defectiveDURING RON MAINTENANCE, THE LEFT FORWARD EMERGENCY EGRESS LIGHT WAS FOUND TO BE DIM. THE BULB WAS REPLACED AND LIGHTING, OPS CHECKED GOOD.SDR CA081209001Cable · broken(CAN) ON RAMP DURING CLOSURE OF THE MAIN CABIN DOOR (MCD), THE FLIGHT ATTENDANT HEARD AN ABNORMAL NOISE INSIDE THE FORWARD CABIN WARDROBE AND THE DOOR FELL HEAVILY OPEN AND SUSTAINED SOME DAMAGES. DURING TROUBLESHOOTING BY LINE MAINTENANCE CREW, THE MCD BALANSDR HNAA2002120800351Unknown · odorDURING OPERATIONS, AN OIL ODOR WAS NOTICED IN THE COCKPIT WITH BLEEDS SELECTED ON. OIL LEVELS IN BOTH ENGINES AND THE ACM UNIT WERE CHECKED AND FOUND TO BE GOOD. BOTH ENGINE NACELLES WERE INSPECTED FOR EVIDENCE OF OIL LEAKS, WITH NONE BEING FOUND. ENGINES WSDR HNAA2008120800341Hydraulic System · contaminatedJUST AFTER TAKEOFF, THE 'RUDDER PRESSURE' AND 'RUDDER FULL PRESSURE' CAUTION LIGHTS ILLUMINATED. THE CREW ELECTED TO RETURN TO THE ORIGINATING AIRFIELD. AFTER THE LANDING GEAR AND FLAPS WERE EXTENDED, THE CAUTION LIGHTS EXTINGUISHED. BOTH HYDRAULIC SYSTEMS SDR HNAA2008120700340Regulator · failedJUST AFTER TAKEOFF, THE 'RUDDER FULL PRESSURE', 'RUDDER PRESSURE', AND 'NR 2 RUDDER HYDRAULIC' CAUTION LIGHTS CAME ON. HYDRAULIC QUANTITIES WERE NORMAL. THE AIRCRAFT WAS RETURNED TO THE FIELD. MAINTENANCE REPLACED THE DUAL PRESSURE REGULATOR. LEAK AND OPS SDR HNAA2008120600339Smoke Detector · malfunctionedDURING OPERATIONS, THE LAVATORY SMOKE DETECTOR BEGAN SOUNDING CONTINUOUSLY. THE TEST SWITCH WAS CYCLED AND THE UNIT OPERATED NORMALLY. THE AIRCRAFT WAS NOT TAKEN OUT OF SERVICE.SDR CA081211004Bracket · cracked(CAN) DURING THE ACCOMPLISHMENT OF TASK 5310/06C, WINDSHIELD AND SIDE WINDOW LOWER SILL JOINT TO SIDE POST, THE BRACKET CONNECTED TO UNDERSIDE OF THE LOWER SILL TO THE SIDE POST (RIGHT SIDE) WAS FOUND TO HAVE A 2 1/2 INCH CRACK IN IT.SDR HNAA2008120200338Acm · contaminatedWHEN THE APU BLEED AIR WAS SELECTED 'ON', THE CABIN FOGGED UP AND SMELLED LIKE OIL. MAINTENANCE REMOVED AND REPLACED THE AIR CYCLE MACHINE. THE APU WAS RUN UP AND THE SYSTEM CHECKED GOOD. NO ODORS OR FUMES NOTED AT THAT TIME AND THE AIRCRAFT WAS THEN RELEASSDR HNAA2008120200328Windshield · arcedBURNING SMELL DETECTED ON FLIGHT DECK IN FLIGHT. INSP AND FOUND WIRE ON TERMINAL L1 FOR CAPTS WINDSHIELD HEAT LOOSE AND WIRE TERMINAL END DAMAGED. REPAIRED WIRE AS REQUIRED AND RESECURED WIRE TO TERMINAL L1 AND REMOVED AND REPLACED CAPTS WINDSHIELD HEAT CONTSDR HNAA2008113000333Apu · odorUPON APU FAILURE, SMOKE ODOR FILLED THE CABIN AND COCKPIT. MAINTENANCE INSPECTED THE APU BAY AND FOUND NO LEAKS. APU WAS RUN FOR 10 MINUTES WITH AND WITHOUT BLEEDS ON. NO DEFECTS WERE NOTED AND NO ODORS WERE DETECTED. AIRCRAFT WAS THEN RELEASED FOR SERVICESDR HNAA2008113000332Display · defectiveDURING GROUND HANDLING WITH APU AND ENGINES RUNNING, THE CREW NOTICED AN ELECTRICAL SMELL IN THE CABIN AND COCKPIT. MAINTENANCE DISCOVERED THE PILOTS ADVISORY DISPLAY PANEL TO BE THE SOURCE OF THE ODORS. THE DISPLAY PANEL WAS PLACED ON THE MEL LIST AND THE ASDR CA081204011Pressure Switch · malfunctioned(CAN) NR 2 EDP AMBER LIGHT CAME ON AT 30 KTS. DURING TAKE-OFF ROLL. ABORTED TAKE-OFF. PRESS WAS NORMAL ON THE INDICATOR, BUT THE NR 2 EDP AMBER CAUTION LIGHT IS ON. TR128. CONNECTOR ON PRESSURE SWITCH CLEANED. NR 2 SYSTEM HYD PRESSURE SWITCH REPLACED.SDR CA081203002Engine · malfunctioned(CAN) ON TAKEOFF ROLL WITH PASSENGERS ON BOARD POWER WAS ADVANCED THROUGH 70 PERCENT TORQUE. A THUD AND GRINDING NOISE WAS HEARD FROM THE RT SIDE. TAKEOFF WAS ABORTED AND AC RETURNED TO THE GATE. ENG TO BE REMOVED AND SENT FOR INVESTIGATION. MFG WILL CONTINUSDR HNAA2008120200326Light · malfunctionedEMERGENCY EXIT SIGN AT SEAT 4A REMAINS ILLUMINATED CONSTANTLY. INSPECTED AND FOUND LIGHT NOT TO BE ILLUMINATED.SDR HNAA2008120200329Battery Pack · dischargedUPON ARRIVAL TO A/C, F/A FOUND EMERGENCY LIGHT TO HAVE BEEN LEFT ON. EMERGENCY LIGHTS DO NOT ILLUMINATE. REMOVED AND REPLACED CABIN EMERGENCY LIGHT BATTERIES, CABIN NUMBER S 3, 4, 5 AND 6 IAW 33-50-05R, OPS CHECK GOOD IAW 33-50-03Q BATTERY S/N SBY-75 , SBY-1SDR HNAA2008112100337Smoke Detector · defectiveTHE LAVATORY SMOKE DETECTOR SOUNDED OFF ABOUT 10 TIMES WITHOUT EVIDENCE OF SMOKE OR FUMES. THE SMOKE DETECTOR WAS DE-ACTIVATED IAW SPECIAL PROCEDURES. MAINTENANCE REPLACED THE DEFECTIVE UNIT, RE-ACTIVATED THE SYSTEM AND OPS CHECKED THE UNIT. OPS CHECKS WERESDR HNAA2008112300324Smoke Detector · malfunctionedLAV SMOKE DETECTOR SOUNDED ABOUT 10 TIMES AND STOPPED, NO EVIDENCE OF SMOKE OR FUMES. LAV SMOKE DETECTOR DEACTIVATED IAW SP 26.2 REFERENCE LP 279923 ITEM 2. REMOVED AND REPLACED LAV SMOKE DETECTOR IAW 26-12-05 AND REACTIVATED SYSTEM OPS CHECK GOOD. P/N ON/OSDR HNAA2008111800331Beta Switch · brokenDURING TAKEOFF AND AFTER GEAR RETRACTION, THE NR 2 ENGINE STARTED TO SURGE BETWEEN 60 TO 100 PERCENT TORQUE. AFTER TURNING BACK TO FIELD, THE CONDITION CLEARED. MAINTENANCE CLEANED AND RESEATED THE ECU CONNECTOR, GROUND RAN AIRCRAFT AND NOTED NO DEFECTS. AISDR HNAA2008111400334Panel · defectiveAFTER PUSHBACK FROM THE GATE, STARTED THE NR 2 ENGINE, TAXIED FROM THE GATE, NOTICED THE APU FAILURE LIGHT WAS ILLUM. THE FLT ATTENDANT WAS NOTIFIED OF THE PROBLEM AS THE AFCT WAS TAXIED BACK TO THE GATE. THE CAPTAIN THEN ELECTED TO ACTIVATE THE APU FIRE BOTSDR HNAA2008111300336Fixture · brokenDURING DESCENT FROM 24000 FEET, THE FLIGHT ATTENDANTS NOTICED A BURNING ODOR IN THE CABIN BUT NO VISIBLE SMOKE. UPON LANDING, MAINTENANCE DEACTIVATED THE CABIN INTERIOR NORMAL LIGHTING SYSTEM, REMOVED THE BULB AND PLACED THE SYSTEM ON THE MEL LIST FOR THIS AISDR CA081114009Structure · damaged(CAN) FLT ENCOUNTERED MULTIPLE BIRD STRIKES AT 4000 FT, DURING AN APPROACH FOR LANDING INTO AIRPORT. CREW CONTINUED ON DESCENT PATH AND LANDING UNEVENTFUL. MX REQUESTED. SUBSTANTIAL DAMAGE TO THE RT SIDE OF RADOME AND STRUCTURE IMMEDIATELY BEHIND RADOME FROM ISDR CA081110007Structure · damaged(CAN) BIRD STRIKE JUST UNDER NOSE AREA. FOUND NR 2 LOWER COWL WITH INTERNAL CONE DAMAGE, LOWER COWL REMOVED. ENGINE BOROSCOPED WITH MINIMAL DEBRIS FOUND INSIDE ENGINE. NO DAMAGE NOTED NO DEBRIS FOUND ON LP COMPRESSOR. AIRFRAME INSPECTION STILL TO BE CARRISDR HNAA2008120200325Filter Element · slowNR 1 OIL PRESSURE LIGHT ILLUMINATED ON TAKEOFF ROLL WITH FLUCTUATION ON PRESSURE GAUGE. REJECTED TAKEOFF, LIGHT EXTINGUISHED REMAINED NORMAL. CONTRACT MAINTENANCE REPORTS SAFETY ON TRANSMITTER BROKEN AND CONNECTOR OIL SOAKED. CLEANED AND SERVICED ENGINE WIT
Back to Boeing DHC-8-102