Boeing DHC-8-102
Service difficulty reports · 9,272
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA050128009Disk · seized(CAN) AFTER STARTED AIRCRAFT, RELEASED PARK BRAKE AND TAXIED NORMALLY , BRAKING AS REQUIRED, DUE TO LONG LINE UP AWAITING TAKEOFF PARK BRAKE WAS APPLIED. WHEN PART BRAKE WAS RELEASED AIRCRAFT UNABLE TO TAXI. MAINTENANCE INSPECTION FOUND BRAKE PISTONS WERE RELSDR CA050125000Pressure Valve · faulty(CAN) THE CREW REPORTED , AFTER GEAR UP SELECTION , LOST NR 2 MAIN AND STANDBY PRESSURE (SPU ON). AFTER APPROXIMATELY 3 MINUTES THEY RECEIVED NR 2 STANDBY PUMP HOT LIGHT. ON SHORT FINAL NR 2 MAIN PRESSURE RETURNED BUT NR 2 STANDBY HOT LIGHT REMAINED ON EVEN TSDR QXEA200500104Brush Block · malfunctionedSEA - FLIGHT 2180 RETURNED TO FIELD NR 1 PROP HUB SPARKING. MAINTENANCE REPLACED THE BRUSH BLOCK. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR HNAA0500003Pump · failedWHILE EN ROUTE FROM CLT TO LYH THE CAPT CALLED MAINTENANCE CONTROL WITH A HYD PUMP CAUTION LIGHT. AFTER TROUBLESHOOTING IT WAS FELT BEST TO DIVERT TO ROA. CREW DID NOT DECLARE AN EMERGENCY. ALSO FOUND HYD SOV FAILED IN CLOSED POSITION. P/N AND S/N OFF AV16SDR CA050121009Ecu · corroded(CAN) NR1 ENGINE, ENGINE CONTROL UNIT WOULD NOT INDICATE (ON). MAINTENANCE FOUND CORROSION INSIDE AND OUTSIDE CONNECTOR J1. ECU REPLACED. (NOTE: TIMES ARE AIRCRAFT TOTAL TIME NOT ACTUAL PART TIME)SDR HNAA0500002Radar · inoperativeWEATHER RADAR SPIKING ON CLIMOUT, TURNS AND ON DESCENT. THE SCREEN GOES BLANK OCCASIONALLY. REMOVED AND REPLACED WEATHER RADAR RT, OPS CHECK GOOD.SDR CA050201003Bearing · failed(CAN) GENERATOR CAUTION LIGHT ILLUMINATED AND ELECTRICAL LOAD WENT TO (0) SUSPECT STARTER BEARING FAILURE DUE TO HEAVY VIBRATION IN THROTTLE HANDLE. STARTER GEN INSPECTED IN SHOP, WO NR182352, BEARING FAILURE NOTED ON DRIVE END (03-6009-23).SDR QXEA200500094Seat Track · gougedPDX - LEFT HAND CENTER SEAT TRACK NR 4 HAS GOUGE AT FRAME 282 TO FRAME 299. REPAIRED IAW SRM 51-40-11.SDR QXEA200500089Seat Track · gougedPDX - RIGHT HAND CENTER SEAT TRACK NR 7 HAS PITTING AND GOUGES FROM FRAME 262.50 TO FRAME 214.400. REPAIRED IAW SRM 51-40-11.SDR QXEA200500092Seat Track · gougedPDX - RIGHT HAND CENTER SEAT TRACK NR 7 HAS GOUGES AT FRAME 397 TO 412. REPAIRED IAW SRM 51-40-11.SDR QXEA200500091Seat Track · gougedPDX - RIGHT HAND CENTER SEAT TRACK NR 7 HAS GOUGES IN TRACK FROM STATION FRAME 350.00 TO FRAME 374. REPAIRED IAW SRM 51-40-11.SDR QXEA200500093Seat Track · corrodedPDX - LEFT HAND CENTER SEAT TRACK NR 4 HAS CORROSION ON FLANGE AT STATION 234.500. REPAIRED IAW SRM 51-40-11.SDR QXEA200500090Seat Track · corrodedPDX - RIGHT HAND CENTER TRACK NR 7 HAS LITE CORROSION AT X210.100 TO FRAME 234.500. REPAIRED IAW SRM 51-40-11.SDR QXEA200500098Seat Track · gougedPDX - LEFT HAND CENTER SEAT TRACK NR 4 HAS GOUGES AT FRAME 405 TO 417. REPAIRED IAW SRM 51-40-11.SDR QXEA200500097Seat Track · corrodedPDX - LEFT HAND CENTER SEAT TRACK NR 4 HAS GOUGES AND CORROSION AT FRAME 378 TO 330 TO 395. REPAIRED IAW SRM 51-40-11.SDR QXEA200500096Seat Track · gougedPDX - LEFT HAND CENTER SEAT TRACK NR 4 HAS GOUGES AT FRAME 350 TO 364. REPAIRED IAW SRM 51-40-11.SDR QXEA200500095Seat Track · gougedPDX - LEFT HAND CENTER SEAT TRACK NR 4 HAS GOUGES AT FRAME 313 AND 330. REPAIRED IAW SRM 51-40-11.SDR QXEA200500088Seat Track · gougedPDX - RIGHT HAND SEAT TRACK NR 7 HAS GOUGES AT STATION 312.350 FRAME TO 333.300 FRAME. REPAIRED IAW SRM 521-40-11.SDR CA050107005Rccb · arced(CAN) WHILE INSPECTING NR 2 AC CONTACTOR BOX IN THE RT NACELLE DURING A HEAVY MX CHECK, DISCOVERED THAT HARDWARE THAT HOLDS WIRES ONTO THE REMOTE CONTROL CIRCUIT BREAKER (RCCB) HAD COME OFF AT 3 OF 6 ATTACH STUDS. RCCB IS FOR NR 1 ENG STANDBY HYD PUMP. HARDWASDR HNAA0500001Wire Harness · misroutedAFTER TAKEOFF NOSE GEAR WOULD NOT RETRACT AND LT & RT GEAR DOORS REMAINED OPEN, NOSE GEAR RED TRANSIT LIGHT STAYED ILLUMINATED. LT AND RT MAINS RETRACTED NORMALLY. REROUTED ELECTRICAL HARNESS AND SEATED CONNECTORS, OPS CHECK GOOD.SDR HNAA0400176Connector · not seatedAFTER TAKEOFF NOSE GEAR WOULD NOT RETRACT AND LT/RT GEAR DOORS REMAINED OPEN, NOSE GEAR RED TRANSIT LIGHT STAYED ILLUMINATED. LT AND RT MAINS RETRACTED NORMALLY. REROUTED ELECTRICAL HARNESS AND SEATED CONNECTOR OPS CHECK GOOD.SDR HNAA0400175Windscreen · crackedFO'S WINDSCREEN SPIDERWEBBED. REMOVED AND REPLACED FO'S WINDSCREEN OPS CHECK GOOD.SDR HNAA0400174Pump · shearedNR 2 MAIN HYD PRESSURE WENT TO ZERO, WITH STANDBY PUMP PRESSURE. REMOVED AND REPLACED NR 2 HYD ENGINE DRIVEN PUMP AND CASE FILTER. OPS AND LEAK CHECK GOOD. FOUND HYD PUMP SHAFT SHEARED.SDR HNAA0400173Terminal Block · inoperativeEMERGENCY LIGHTS FLICKERED ON AND OFF SEVERAL TIMES IN FLIGHT. REMOVED AND REPLACED 9811-TB14 MODULES 4 AND 7.SDR CA050211008Computer · malfunctioned(CAN) ON CLIMB OUT WITH CABIN PRESSURIZATION SET TO AUTO IN BOTH NORMAL AND CAB SET MODE THE RATE OF PRESSURIZATION WAS UNCONTROLLABLE UP TO MAX DIFF.A/C RETURNED TO DEPT AIRPORT. SYSTEM OPERATED SERV IN MANUAL MODE. COMPUTER REPLACED AND FUNCTION CHECKS CARRISDR CA050107007Shaft · sheared(CAN) NR 1 ENG HYD PUMP CAUTION LIGHT ILLUMINATED WITH FLAP RETRACTION ON TAKEOFF. NR 1 SPU TURNED OFF, MAIN PRESSURE DEPLETED TO 0 PSI. FLUID QTY REMAINED STEADY. A/C RETURNED TO YYZ. INPUT SHAFT SHEARED FROM AN INTERNAL FAILURE. PUMP DISMANTLED. INTERNSDR HNAA0400170Diode · shortedON APPROACH TO DCA, ALL THREE LANDING GEAR DOORS OPENED AND CLOSED THEN OPENED AGAIN. FERRIED A/C TO SBY FOUND 2 BAD DIODES 3261-CR1 AND 3261-CR2 REMOVED AND REPLACED DIODES, OPS CHECK GOOD.SDR HNAA0400166Stringer · corrodedMAJOR REPAIR, DURING C CHECK, FOUND CORROSION ON STR 31S. LOCALLY BLENDED OUT CORROSION. INSTALLED TRIMMED REPAIR ANGLES.SDR HNAA0400168Skin Panel · corrodedDURING C CHECK, CORROSION WAS FOUND ON SKIN PANEL 85320106-155. TRIMMED OUT DAMAGED SKIN AND HFEC , BOND CHECK SKIN. FABRICATED PACKER AND REPAIR DOUBLER, INSTALLED REPAIR PARTS.SDR HNAA0400167Stringer · corrodedDURING C CHECK, FOUND WIDESPREAD CORROSION ON STR 31 STARBOARD. CUT STR 31 STARBOARD AND HFEC BOND CHECK STR 31. INSTALLED NEW STR 31 STARBOARD.SDR HNAA0400165Stringer · damagedMAJOR REPAIR DURING C CHECK WHILE WORKING REPAIRS FOR LIGHTNING STRIKE DAMAGE ELONGATED HOLES DRILLED IN STR 30P NECESSITATING REPAIR BY SPLICING REPLACEMENT SECTION. CUT STR30P, HFEC, FABRICATED REPLACEMENT SECTION, TRIMMED REPAIR ANGLES, INSTALLED PARTSSDR HNAA0400164Skin Panel · lightning strikeTHIS EO PERFORMS REPAIR FOR FUSELAGE SKIN DAMAGED BY LIGHTNING STRIKE BY TRIMMING OUT DAMAGED SKIN ONLY AND INSTALLING EXTERNAL REPAIR DOUBLER. TRIMMED OUT DAMAGE SKIN AND WAFFLE. HFEC AND BOND TESTED. FABRICATED REPAIR DOUBLER AND PACKER. INSTALLED PARTSSDR HNAA0400163Skin Panel · lightning strikeTHIS EO PERFORMS REPAIR FOR FUSELAGE SKIN DAMAGED BY LIGHTNING STRIKE BY TRIMMING OUT DAMAGED SKIN ONLY AND INSTALLING EXTERNAL REPAIR DOUBLER. DMT FOR MANUFACTURERS DT REVIEW ALSO CREATED. REV A. ADDRESSES CHANGE DUE TO DAMAGE INCURRED DURING REPAIR ACCOMPLISSDR QXEA200400812Seat Track · corrodedPDX - NR 2 SEAT TRACK HAS LIGHT SURFACE CORROSION ON TOP OF RAILS AT X451-X453, X486 AND IN BOTTOM OF CHANNEL AT X439 AND X452. REPAIRED IAW RD 8-53-8209, PAGE 4, FIGURE 4.SDR QXEA200400809Seat Track · corrodedPDX - FORWARD RIGHT HAND INBOARD SEAT TRACK TOP SURFACE HAS CORROSION AT APPROXIMATELY STATION X215.500. REPAIRED IAW RD 8-53-1102.SDR QXEA200400807Seat Track · corrodedPDX - NR 4 SEAT TRACK OUTBOARD FLANGE HAS CORROSION ON TOP SURFACE FROM X201 TO X228. REPAIRED IAW DHC-8-200 SRM 51-40-11.SDR QXEA200400813Seat Track · corrodedPDX - NR 1 SEAT TRACK HAS LIGHT SURFACE CORROSION ON TOP OF RAILS AT STATIONS X295-297, X330-X332, X363-X366, X376-X379, X393, X406-X409 AMD X425. REPAIRED IAW RD 8-53-1342, SRM 51-40-00 AND SRM 51-40-11.SDR QXEA200400811Seat Track · corrodedPDX - NR 1 SEAT TRACK HAS CORROSION IN BOTTOM OF TRACK AT X309 AND X424. REPAIRED IAW RD 8-53-1342 AND SRM 51-40-00.SDR QXEA200400810Seat Track · corrodedPDX - RIGHT HAND OUTBOARD SEAT TRACK HAS CORROSION AT CENTER CHANNEL AND CHANNEL RADIUS AT APPROXIMATELY STATION X451.000. REPAIRED IAW DHCC8-200 SRM 51-40-00 AND SRM 51-40-11.SDR QXEA200400808Frame · crackedPDX - VERTICAL STABILIZER FRAME 4 IS CRACKED AT STRINGER RT 4 IN AFT FUSELAGE SECTION. REPAIRED IAW RD 8-55-199.SDR HNAA0400131Buss Bar · faultyFLIGHT 3798 BWI TO LGA HAD TO DIVERT TO PHL DUE TO THE NR 1 DC GEN FAILING AND THEN THE NR 2 DC GEN FAILING. AIRCRAFT BRIEFLY ON BATTERY POWER. NAVS, PRESSURIZATION, AND ANTI-ICE SYSTEMS WERE LOST. AN EMERGENCY WAS DECLARED AND THE FLIGHT DIVERTED TO PHL. SDR HNAA0400130Hydraulic System · contaminatedNR 2 HYD CAUTION LIGHT ILLUMINATING DURING GEAR RETRACTION. FLIGHT RETURNED. MAINTENANCE JACKED AIRCRAFT AND SWUNG THE LANDING GEAR SEVERAL TIMES. BLED THE NR 2 HYDRAULIC SYSTEM AND SERVICED AS NEEDED. ALL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR CA041103008Indicator · reads low(CAN) DURING CRUISE NR 1 OIL PRESSURE DROPPED, PRECAUTIONARY SHUTDOWN OF & FEATHER OF NR 1 ENGINE , AIRCRAFT RETURNED TO ORIGINATING AIRPORT. MAINTENANCE INSPECTION FOUND OIL PRESSURE, TEMP INDICATOR AT FAULT . INDICATOR REPLACED.SDR HNAA0400159Pump · failedNR 1 EDP HYD PUMP FAILED AFTER T/O 20 MILES NORTH OF SBY, EXPERIENCED NR 1 HYD SYSTEM QUANTITY AND PRESS LOSS. REMOVED AND REPLACED R HYD PUMP AND HYDRAULIC LINE P/N 82970010-477.SDR HNAA0400129Acm · odorFLIGHT NR 3802 REPORTED A STRONG ODOR EMIITING FROM THE ACM. MAINTENANCE REMOVED AND REPLACED THE ACM. OPERATIONAL CHECKS GOOD. SYSTEM RETURNED TO SERVICE.SDR CA041029010Smoke Detector · malfunctioned(CAN) DURING DESCENT , INTERMITTANT BAGGAGE SMOKE WARNING. CREW ELECTED TO DON OXYGEN MASKS AND ADVISE AIRPORT EMERGENCY RESPONSE. UPON ARRIVAL NO EVIDENCE OF SMOKE OR FIRE FOUND. BAGGAGE SMOKE DETECTOR REPLACED. REMOVED UNIT TESTED AS NO FAULT FOUND. AIRCRAFTSDR CA041026006Tube · cracked(CAN) BOTH WELDED TUBE ASSEMBLIES P/N 1B1107-1FOUND CRACKED IN ROLLER RADIUS AT THE BASE OF THE CAPTAIN'S SEAT ASSY . DEFECTS WERE NOTED DURING ROUTINE INSPECTION PROCESS IN THE SEAT SHOP , WHEN THIS SEAT WAS REMOVED OFF THE AIRCRAFT DURING AHEAVY MAINTENANCSDR CA041025003Skin · corroded(CAN) DURING A ROUTINE HEAVY MAINTENANCE INSPECTION WIDESPREAD LEVEL ONE CORROSION WASFOUND ON THE UPPER WING SKIN AT THE MATIN SURFACES OF THE FORWARD AND REAR SPARS. INITIALLY LEVEL ONE CORROSION WAS FOUND JUST AHEAD OF THE REAR SPAR AND JUST AFT OF THE FORWSDR HNAA0400156Door · out of adjustAFTER GEAR RETRACTION LEFT MAIN GEAR DOOR LT CAME ON AND VISUALLY CONFIRMED DOOR OPEN. DUE TO THE AIRSPEED RESTRICTION, A/C RETURNED TO PHL. A/C WILL FERRY TO SBY FOR REPAIRS. ADJUSTED LEFT FWD GEAR DOOR. GEAR SWINGS, OP'S CHECK GOOD.SDR HNAA0400128Adiru · failedFLIGHT NR 3933 REPORTED HAVING A STRONG ELECTRICAL BURNING SMELL IN THE COCKPIT SHORTLY AFTER CAPTAIN'S ADI FAILED. MAINTENANCE COULD NOT DUPLICATE. ADI OPERATED NORMALLY. AIRCRAFT RETURNED TO SERVICE.
Back to Boeing DHC-8-102