Boeing MD-11F
Service difficulty reports · 31,322
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WRLA97005Engine · overtempDURING CRUISE, CREW RECEIVED NR 1 ENGINE OVERSPEED AND OVERTEMP INDICATION ON ENG ALERT DISPLAY. CREW RETARDED THROTTLE TO FLT IDLE. ENG PARAMETER RETURNED TO NORMAL. CREW SLOWLY ACCELERATED ENGINE TO NORMAL POWER SETTING WITH NO FAULT INDICATION AND ENGAGESDR 97FDEA00064Fire Detector · malfunctionedPASSING 11,000 GOT NR 1 ENG FIRE WARNING, AURAL AND BELL. DID NOT HAVE LIGHT IN HANDLE OR ANY OTHER INDICATION OF FIRE, EGT NORMAL. NO RISE IN EGT, SHUTDOWN AND RETURN TO MEMPHIS. REMOVED AND REPLACED LWR TURBINE DETECTOR ASSY.SDR 97FDEA00048Bracket · failedOUTBD PULLEY SUPPORT BRACKET HAS 3 MISSING MOUNT BOLTS CAUSING AN INCH GAP TO WEB AT FWD SIDE AND SEVERAL SHEARED RIVETS AT LOWER AND UPPER ROWS. LOCATED AT OUTBD WEB OF NR 1 SLAT CENTER TRACK, STA NR X1S204 RT WING. *S/D* FABRICATED SUPPORT BRACKET PER DW-SDR 97FDEA00045Trunnion Pin · corrodedDURING REMOVAL OF LT MLG FORWARD TRUNNION PIN, DURING SCHEDULED MAINTENANCE, FOUND PIN SEVERELY CORRODED WITH ASSOCIATED PLATING LOSS ALONG ENTIRE CIRCUMFERENCE, AT BUSHING CONTACT POINTS. ALSO, THERE IS PLATING LOSS ALONG LIMITED OTHER POINTS ALONG PIN SURFASDR 97FDEA00036Oil Temp Ind · malfunctionedNR 3 ENG SHUTDOWN IN CRUISE DUE TO HIGH OIL TEMP AND FALLING OIL QTY, OIL TEMP REACHED 185 DEGREES AFTER SHUTDOWN, OIL THEN BECAME ERRATIC AND FLUCTUATED FROM HIGH TO LOW. WHEN A/C ARRIVED IT HAD 14 QTS OF OIL SERV OIL SYS WITH 3 QUARTS AND READ FULL. CKD ALSDR 97FDEA00035Pseu · malfunctionedAFTER TAKEOFF, RT MLG UNSAFE LIGHT ON BOTH PRIMARY AND SECONDARY GEAR INDICATION. CHECKED DOOR CYLINDER PISTON LENGTH IS WITHIN M/M LIMITS. REMOVED AND REPLACED PROX SWITCH ELECTRONICS UNIT. REMOVED AND REPLACED BOTH PRIMARY AND SECONDARY GEAR UP AND LATCHESDR 97FDEA00026Switch · out of adjustAFTER T/O, RECEIVED A TAIL FUEL FORWARD FOLLOWED SHORTLY BY A CROSSFEED DISAGREE. CYCLED FSC AND TRIED TO MANAGE FUEL IN MANUAL, COULD NOT TRANSFER FUEL INTO THE MAINS. IT APPEARS IF FUEL WAS IN FACT BEING TRANSFERRED EVEN THOUGH THERE WAS NO INDICATION ON TSDR 97FDEA00018Fire Detector · malfunctionedAPPROACHING NRT, CARGO FIRE LOWER AFT ALERT DISPLAYED, AGENT DISCHARGED IAW PROCEDURE. AFTER LANDING NO INDICATION OF FIRE OBSERVED. ALERT OCCURRED AT 3,000 FEET, CARGO TEMPERTURE NORMAL. FOUND NO FAULTS ON CURRENT AND FAULT REVIEW IN MSC AND DEU 1, 2, 3. SDR 96FDEA01712Drain Line · brokenHYDRAULIC SYSTEM NR 3 OFF ALERT, HYDRAULIC PRESSURE WENT TO ZERO, SYSTEM QUANTITY WAS AT 3.2 GALLONS AND OTHER WARNINGS WERE PRESENT BECAUSE OF HYDRAULIC LOSS. FABRICATED NEW LINE PER EA 1-2910-31452, INSTALLED AND LEAK CHECKED, OPS CHECKED GOOD. NEW LINE TOSDR 96FDEA01709Bulkhead Fitting · crackedTHE CENTER LANDING GEAR WHEEL WELL AREA HAS A CRACK AT THE RT BULKHEAD AND DRAG LINK VERTICAL SUPPORT FITTING AT STA 1453 AT X = - 31.50 CRACK MEASURES 13 AT LOWER END OF FITTING. ADDITIONALLY, VERTICAL STIFFENERS AND DIAGONAL STIFFENER HAVE DEEP GOUGES AT STSDR 96FDEA01702Tube · brokenDURING CRUISE, NR 3 HYDRAULIC SYSTEM FAILED (LOSS OF FLUID). PUMPS WERE TURNED OFF WITH 2.4 GALLONS REMAINING. REPLACED RT PUMP. CASE DRAIN REPLACED. P/N 224-9409-521. LEAK CHECKS GOOD, OK FOR SERVICE.SDR WRLA96053Control Cable · bindingDURING TAXI-OUT, FLIGHT CREW RECEIVED A NR 3 ENGINE FADEC MAINTENANCE ALERT. FLIGHT CREW ELECTED TO RETURN TO DEPARTURE GATE FOR CORRECTIVE ACTION. AIRCRAFT RETURNED TO GATE WITHOUT INCIDENT. MAINTENANCE PERSONNEL FOUND TURBINE CASE COOLING (TCC) CONTROL VASDR 96FDEA01695Trim Cylinder · malfunctionedAFTER TAKEOFF, GEAR HANDLE WOULD NOT RAISE TO RETRACT THE GEAR. REMOVED AND REPLACED THE BOGIE TRIM CYCLINDER, OPS CHECK GOOD.SDR WRLA96047Fan Blade · bird strikeDURING TAKEOFF, FLT CREW NOTICED FLOCK OF BIRDS IN AREA OF FLIGHT PATH, SHORTLY AFTER CREW NOTICED NR 1 ENGINE HAVING EXCESIVE VIBRATION. BIRD INGESTED INTO NR 1 ENGINE. FLIGHT CREW ELECTED TO RETURN TO POINT OF DEPARTURE FOR REPAIRS. AIRCRAFT LANDED WITHOUSDR 96FDEA01659Hydraulic Tube · leakingHYD SYS NR 3 FAIL ALERT DISPLAYED. REMOVED AND REPLACED LEAKING PRESSURE LINE AT NR 3 HYD MANIFOLD. REMOVED AND REPLACED HYD FILTERS AND BOTH ENGINE DRIVEN PUMPS.SDR 96FDEA01572Fan Air Valve · malfunctionedNR 2 ENG BLEED AIR HIGH TEMP, POWER REDUCED, ALERT WENT OUT. REMOVED AND REPLACED NR 2 ENG FAN AIR VALVE SYS OPS CHECK GOOD WITH ENG RUN.SDR 96FDEA01560Engine · crackedENGINE FAILED INSP PER EA 1-7220-31514, INSP OF FIRST STAGE BOOSTER VANES. FOUND NUMEROUS LOOSE AND MISSING FASTENERS BOOSTER CASE CRACKED IN SEVERAL PLACES. REMOVED AND REPLACED NR 2 ENGINE. RII COMPLETED, ENG RUN, LEAK AND OPS CHECK GOOD.SDR 96FDEA01555Power Relay · failedSFS - APPROXIMATELY 25 MINUTES INTO FLIGHT, THE FIRST OFFICER LOST ALL DISPLAYED INSTRUMENTATION. AIR TURNBACK TO SFS, CURRENTLY BEING T/S. REMOVED AND REPLACED THE NR 3 AUXILIARY POWER RELAY. RAN ENGINE, POWER TRANSFER OK.SDR 96FDEA01541Engine · failedENGINE FAILED INSPECTION PER EA 1-7220-31511 INSP OF FIRST STAGE BOOSTER VANES.SDR 96FDEA01540Engine · failedENGINE FAILED INSPECTION PER EA 7-7220-31529 INSP OF FIRST STAGE BOOSTER VANES.SDR 96FDEA01533Stator Case · crackedINSP OF THE FIRST STAGE BOOSTER VANES, EA 1-7220-31513, EA COMPLETED ON NR 1 ENG, FOUND 22 MISSING FASTENERS AND SEVERAL CRACKS IN STATOR CASE. REMOVED AND REPLACED NR 1 ENG PER WORK CARD 29T0301, 54T0201, 71T0101, 71T0701 AND FEC -M-3238, OPS CK AND LEAK SDR 96FDEA01460Idg · failedTHIS A/C HAD THE NR 2 IDG DEFERRED. IN FLIGHT THE NR 3 IDG WENT INOP, THE CREW DID AN AIR TURNBACK INTO NADI. PER THE MEL YOU CANNOT DEFER TWO IDG AT THE SAME TIME. REMOVED AND REPLACED THE NR 3 IDG.SDR 96FDEA01388Door · crackedSNRM 7045 AND 7046, LT MAIN LANDING GEAR DOOR CRACKED FWD AND AFT OF CENTER HINGE INTER SKIN. *S/D* STOP DRILLED CRACK PER SRM 51-00-01 AND FABRICATED DOUBLERS AND SKIN FOR REPAIR PER SRM 52-10-00.SDR 96FDEA01387Web · crackedHORIZONTAL WEB CRACKED 0.500 JUST AFT OF PRESSURE BULKHEAD STA 2007, APPROX RBL 20 TO 30 AND ABOVE TAG HORIZONTAL BOX SECTION. *S/D* REMOVED NECESSARY FASTENERS. NDT VERIFIED END OF CRACK. FABRICATED AND INSTALLED REPAIR PER EA 1-5310-28046.SDR WRLA96033Temp Sensor · failedDURING TAXI OUT, FLIGHT CREW NOTED NR 9 BRAKE TEMPERATURE INDICATOR OVERHEAT ALERT. FLIGHT CREW ELECTED TO RETURN TO GATE. AIRCRAFT RETURNED TO GATE WITHOUT FURTHER INCIDENT. REPLACED TEMP SENSOR, GROUND CHECKS OK. AIRCRAFT RETURNED TO SERVICE. (M)SDR 96FDEA01358Casting · crackedNR 5002, LT WING O/B FLAP I/B HINGE TENSION TIE SUPPORT STRAP CRACKED AT LOWER ATTACH BOLT HOLE AS SEEN FROM LWR EXTERNAL SURFACE STA XORS562, VERIFIED BY HFEC.SDR WRLA96030Hyd Controller · failedDURING TAXI, FLIGHT CREW RECEIVED 'HYDRAULIC SYSTEM CONTROLLER AUTO INOP' WARNING. FLIGHT CREW RETURNED TO GATE WITHOUT FURTHER INCIDENT. MAINTENANCE PERSONNEL CONFIRMED HYDRAULIC SYSTEM CONTROLLER FAILED. REMOVED AND REPLACED HYDRAULIC SYSTEM CONTROLLER. SDR WRLA96029Hyd Pump · failedON CLIMB-OUT, CREW RECEIVED 'HYD PUMP 3 OFF' ANNUNCIATION. HYD CONTROLLER OPERATED NORMALLY, NR 3 STANDBY PUMP CAME INTO OPERATION. FLT CREW CONTINUED WITH FLT. AFTER 1HR 45 MINS AT CRUISE, FLT CREW RECEIVED 'HYD SYSTEM 3' FAILED ANNUNCIATION. AT THAT TIMESDR 96FDEA01297Casting · brokenSNRM 5020 THE L/H WING, O/B FLAP, I/B HINGE FITTING SUPPORT CASTING IS BROKEN OUT AT THE WING REAR SPAR, LOWER TANG, WING STA XORS 560 APPROX. ******S/D ******* REPLACED L/FLAP TENSION STRAP SUPPORT WITH NEW ONE, PER MDC SB 57-0-10 CONDITION II DSDR 96FDEA01351Strap · crackedRIGHT WING OUTBOARD FLAP, INBOARD HINGE TENSION STRAP SUPPORT CRACKED AT LOWER ATTACH BOLT HOLE, LOWER SURFACE (EXTERNAL) STA X ODRSX562390. REPLACED RIGHT FLAP TENSION STRAP SUPPORT WITH NEW PART PER MDC SB 57-0-10 CONDITION II AND C/W EA 1-5710-29039.SDR WRLA96027Eec Data Plug · misinstalledDURING TAKEOFF ROLL, FLIGHT CREW NOTED NR 1 ENGINE WOULDNOT PRODUCE REQUESTED POWER (62,000 LB). ALL OTHER ENGINE PARAMETERS WERENORMAL. FLIGHT CREW CONTINUED TAKEOFF. HOWEVER, AT PIC'S OPTION, AIRCRAFTRETURNED TO POINT OF DEPARTURE (AIR TURN-BACK). AIRCRASDR 96FDEA01107Hyd Line · failedEN ROUTE AT 12.40Z NR 3 HYD SYS LOSS/FAILURE OCCURED ALL FLUID LOST. ALL ABNORMAL CHECKLIST AND PROCEDURES COMPLETED. REPLACED PRESS LINE THAT GOES FROM THE ENG DRIVEN PUMP TO THE FILTER MODULE. THIS WAS DONE ON EA 1-2910-23270. FINAL FIX WAS DONE IN EWR 6-SDR 96FDEA00999Structure · damagedHARD LANDING WITH TAIL STRIKE. STRUCTURAL DAMAGE BEING EVALUATED IN ANC BY ENGINEERING AND DAC RAMS TEAM. *S/D* DURING MAINTENANCE C-CHECK, A HARD LANDING INSPECTION WAS ACCOMPLISHED. ALSO, DURING THE C-CHECK THE STRUCTURAL DAMAGE CAUSED AS A RESULT OF HARSDR WRLA96018Hyd Pump · failedDURING CLIMB-OUT, FLT CREW NOTED NR 2 L HYD PUMP OFF' ALERT. HYD SYS CONTROLLER SHUTDOWN NR 3 LT TO ACTIVATED NR 3 RT HYD PUMP. CREW NOTED SLOW LOSS OF NR 3 HYD SYS FLUID QTY. WHEN SYS REACHED 5.5 GAL, FLT CREW UTILIZED ABNORMAL PROCEDURES AND SHUTDOWN NR 3SDR 96FDEA00798Rib · crackedRT WING L/E RIB HAS A VISUAL CRACK INDICATION AT THE LOWER RADIUS APPROX 1.5 INCH LONG ON XORSS562.SDR 96FDEA00797Skin · bulgeLT MLG GEAR WELL DOOR EXTERNAL SKIN BULGED ADJACENT TO CENTER HINGE SEGMENT, 52 INCHES FROM L/E OF DOOR.SDR 96FDEA00796Frame · crackedLT MLG GEAR WELL DOOR UPPER FRAME CRACKED. LOCATED 12 INCHES FWD OF GEAR WELL DOOR ACTUATOR I/B STRUT FAIRING. STOP DRILLED CRACK PER SRM 52-10-00, FABRICATED REPAIR DOUBLER PARTS REF SRM 52-10-00 AND INSTALLED REPAIR DOUBLERS REF SRM 52-10-00 PAGE 46.SDR 96FDEA00795Frame · crackedLT MLG GEAR WELL DOOR UPPER FRAME CRACKED. LOCATED 16 AFT OF GEAR WELL DOOR ACTUATOR I/B STRUT FAIRING. CRACK GOES TO EXISTING HOLE AS PER SRM 52-10-11 FIG 13 SHEET 2. FABRICATED DOUBLERS REF SRM 52-10-00 FIG 13 SHEET 2 AND INSTALLED DOUBLERS REF SRM 52-10-SDR 96FDEA00731Retract Mech · malfunctionedAFTER TAKEOFF, THE LANDING GEAR HANDLE WOULD NOT MOVE TO THE UP POSITION. ACCOMPLISHED CHECKLIST AND LANDED. WE HAD NOSE WHEEL STEERING AVAILIABLE IN FLT AND THE AUTOPILOT AND THE FCP WORKED NORMALLY. RESET AND SAFTIED MLG TRIM CYLINDER INTERLOCK CYL FUSE PSDR 96FDEA00469Engine · failedDURING CLIMB OUT, NR 1 ENGINE COMPRESSOR STALLS. THROTTLE WAS RETARDED, ENGINE CONTINUED TO STALL, FLIGHT CREW SHUT DOWN NR 1 ENGINE. THE AIRCRAFT RETURNED TO MEMPHIS. POWER PLANT LINE FOUND METAL IN THE TAIL PIPE. C/A FOUND METAL IN TAILPIPE. BOPED HPT CSDR 96FDEA00241Cylinder · failedDURING OPS CK OF NOSE WHEEL STEERING, THE RT STEERING CYLINDER BLEW APART (LITERALLY). ** (S/D) ** REMOVED AND REPLACED RT NOSE WHEEL STEERING CYLINDER PER MM 32-52-30. S/N OFF AP214, S/N ON FEC101.SDR 96FDEA00073Stringer · crackedFOUND STRINGER 34L SEVERED FWD OF PREVIOUS SKIN CRACK STATION FS 545. FABRICATED STRINGER 34L PER SAMPLE AND INSTALLED PER SRM 51-00-01.SDR 96FDEA00071Stringer · crackedFORWARD END OF STRINGER 35L CRACKED FROM RIVET HOLE TO FWD END LENGTH. APPROXIMATELY .1250 INCH FS 545 CONFIRMED BY HFEC. FABRICATED STRINGER 35L PER SAMPLE AND INSTALLED STRINGER PER SRM 51-00-01.SDR 96FDEA00054Frame · crackedCENTERLINE LANDING GEAR DOOR, RT FWD DOOR IS CRACKED AT LOWER FWD CORNER AT RADIUS. REMOVED CRACKED FRAME AND INSTALLED NEW FRAME PER SRM 51-00-01.SDR 96FDEA00053Door · crackedCENTERLINE LANDING GEAR DOOR, LT FWD DOOR IS CRACKED AT LOWER FWD CORNER AT RADIUS. REMOVED LOWER CORNER SECTION LOCATED NEW FRAME, INSTALLED NEW FRAME PER SRM 51-00-01.SDR 96FDEA00052Door · crackedLT MLG DOOR HAS 2 INCH CRACK AT UPPER MID HINGE AREA, LWR SKIN.SDR WRLA96001Act Arm Bolt · missingWHILE TAXIING, FLIGHT CREW WAS PERFORMING FLIGHT CONTROL CHECK. LEFT INBOARD SPOILER WOULD NOT INDICATE 'FULL-UP' ON TEST. FLIGHT CREW ELECTED TO RETURN TO GATE FOR CORRECTIVE ACTION. AIRCRAFT RETURN TO GATE WITHOUT FURTHER INCIDENT. MAINTENACNE TROUBLE SHSDR 95DEA001893Nose Cowl · separatedEN ROUTE FROM VANCOUVER TO MEMPHIS, THE TOP OF THE NR 2 ENGINE INTAKE COWLING SEPARTED FROM THE AIRCRAFT, RESULTING IN DAMAGE TO NOSE COWL AND THE LEADING EDGE OF THE VERTICAL STABILIZER. NOSE COWL REMOVED AND REPLACED. BULKHEAD BLANKETS REPLACED AND REPAIRESDR 95FDEA01893Intake Cowl · separatedEN ROUTE FROM VANCOUVER TO MEM, THE TOP OF THE NR 2 ENGINE INTAKE COWLING SEPARATED FROM THE A/C RESULTING IN DAMAGE TO THE NOSE COWL AND THE LEADING EDGE OF THE VERTICAL STABILIZER.SDR 95FDEA01838Actuator · malfunctionedUPON FLAP/SLAT RETRACTION FOLLOWING T/O, AILERON DEFLECT DISAGREE LEVEL 2 LIGHT ILLUMINATED. PERFORMED ABNORMAL CHECKLIST IN RED BOOK PAGE 2-5-13 AND IAW CHECKLIST DUMPED FUEL AND RETURNED FOR LANDING. FOUND RT O/B AILERON FULLY DEFLECTED AND LT O/B AILERON
Back to Boeing MD-11F