Service difficulty report · Fire Detector · Doug MD11F

Difficulty date
January 5, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N606FE
Make and model
Doug MD11F
Aircraft serial
48602
Part
Fire Detector
Condition
Malfunctioned
Location
Cargo Compt
Stage of operation
DE
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APPROACHING NRT, CARGO FIRE LOWER AFT ALERT DISPLAYED, AGENT DISCHARGED IAW PROCEDURE. AFTER LANDING NO INDICATION OF FIRE OBSERVED. ALERT OCCURRED AT 3,000 FEET, CARGO TEMPERTURE NORMAL. FOUND NO FAULTS ON CURRENT AND FAULT REVIEW IN MSC AND DEU 1, 2, 3. CHECKED ALL SMOKE DETECTOR AND OVERHEAT DETECTOR, FOUND NORMAL. REMOVED AND REPLACED NR 1 CARGO FIRE CONTAINER PER MM 26-22-01. PRECAUTIONARY REMOVED AND REPLACED MSC PER M/M 31-42-01, RTS PASSED. REMOVED AND REPLACED NR 3 AFT CARGO SMOKE DETECTOR PER MM 26-14-01, FUNCTION TEST GOOD.